A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components www.standexmeder.com Series Datasheet - SHV Reed Relays SHV Series Reed Relays Features: Small Size High Voltage Relay, High Dielectric Strength up to 4 kVDC, Internal Magnetic Shield Applications: Portable Test and Medical Equipment, Defibrillators, Cable and In-Circuit Tester & Others Markets: Test and Measurement, Medical & Others SHV 00-1A85-78X0K Part Description: Nominal Voltage Contact QTY Contact Form Switch Model Pin Out Option Breakdown Voltage 05, 12 1 A 85 78 D, L 2K, 3K, 4K Customer Options Contact Data Switch Model Rated Power (max.) 100 W 1,000 V 1.0 A 2.5 A 150 mOhm 2/3/4 kVDC 1.1 ms 0.1 ms 1010 Ohm 0.5 pF 85 Any DC combination of V&A not to exceed their individual max.'s Switching Voltage (max.) DC or peak AC Switching Current (max.) DC or peak AC Carry Current (max.) DC or peak AC Contact Resistance (max.) @ 0.5V & 50mA Breakdown Voltage (min.) According to EN60255-5 Operating Time (max.) Incl. Bounce; Measured with w/ Nominal Voltage Release Time (max.) Measured with no Coil Excitation Insulation Resistance (typ.) Rh<45%, 100V Test Voltage Capacitance (typ.) @ 10kHz across open Switch USA: Europe: Asia: +1.866.782.6339 +49.7731.8399.0 +86.21.37820625 salesusa@standexmeder.com info@standexmeder.com salesasia@standexmeder.com Modifications in the sense of technical progress are reserved. Unit Version 01 21.09.2015 D. Stastny A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components www.standexmeder.com Series Datasheet - SHV Reed Relays Coil Data Contact Form Switch Model Coil Voltage (nom.) Coil Resistance (typ.) Pull-In Voltage (max.) Drop-Out Voltage (min.) Nominal Coil Power (typ.) VDC Ohm VDC VDC mW 05 180 3.75 0.5 139 12 500 8.4 1.8 288 05 140 3.75 0.5 179 12 500 8.4 1.8 288 Unit 85 (3kV) 1A 85 (4kV) The Pull-In / Drop-Out Voltage and Coil Resistance will change at rate of 0.4% per C. Relay Data SHV Reed Relay Unit Dielectric Strength Coil/Contact (min.) 4 kVDC 1012 Ohm 1.2 pF 30 g 20 g Operating Temperature -40 to 100 C Storage Temperature Soldering Temperature (max.) -40 to 125 C 260 C according to EN60255-5 Insulation Resistance Coil/Contact (typ.) Rh<45%, 200V Test Voltage Capacitance Coil/Contact (typ.) @ 10 kHz Shock Resistance (max.) 1/2 sine wave duration 11ms Vibration Resistance (max.) 5 sec. max. Washability Fully Sealed Life Test Data *Load increase reduces life expectancy of Reed Switches Handling & Assembly Instructions Switching inductive and/or capacitive loads creates voltage and/or current peaks, which may damage the relay. Protective circuits need to be used. External magnetic fields need to be taken into consideration, including a too high assembly density. This may influence the relays' electrical characteristics. Mechanical shock impacts, e.g. dropping the relays, may cause immediate or post-installation failure. Glossary Contact Form Form A NO = Normally Open Contacts SPST = Single Pole Single Throw Form B NC = Normally Closed Contacts SPST = Single Pole Single Throw Form C Changeover SPDT = Single Pole Double Throw USA: Europe: Asia: +1.866.782.6339 +49.7731.8399.0 +86.21.37820625 salesusa@standexmeder.com info@standexmeder.com salesasia@standexmeder.com Modifications in the sense of technical progress are reserved. Version 01 27.01.2015 D. Stastny A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components www.standexmeder.com Series Datasheet - SHV Reed Relays Pin Out 2.54mm [0.10"] pitch grid USA: Europe: Asia: +1.866.782.6339 +49.7731.8399.0 +86.21.37820625 salesusa@standexmeder.com info@standexmeder.com salesasia@standexmeder.com Modifications in the sense of technical progress are reserved. Version 01 27.01.2015 D. Stastny