Specifications: Features: * High Peak Current Design -- High Insertion Loss for Switching Power Supply Emissions * Low-Leakage Current * Compact Case Sizes in 6 and 10Amp Models * Available with Integral IEC Connector in 3 and 6Amp Models F1400 Simplified Schematic G N N Nominal Current Rating LOAD L L LINE SINGLE PHASE FILTERS High Performance F1400 RFI Filters Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1.5A 6A 4A 10A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 at 100VDC Ambient Temperature: 40C Max. at rated current Humidity Range: 0% to 95% R.H. Termination: A: QC - Quick Connect B: Wire C: IEC Receptacle Maximum Leakage Current: Each Line to Ground F1400 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: MINIMUM INSERTION LOSS - dB (50 ohm Circuit) Part Number Termination Line/Load MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 3A F1400AA03 F1400BB03 F1400CA03 QC/QC Wire/Wire IEC/QC Common Differential 58 40 65 60 65 65 65 65 60 65 44 60 6A F1400AA06 F1400BB06 F1400CA06 QC/QC Wire/Wire IEC/QC Common Differential 58 36 65 55 65 60 65 60 60 55 54 50 10A F1400AA10 F1400BB10 QC/QC Wire/Wire Common Differential 56 40 65 50 65 60 65 65 60 65 54 60 NOTE: Other combinations of terminals may be specified on special order. 16 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. F1400AA (3, 6 and 10Amp) Dimensions A .188 Dia. (4,77) 2 Holes D L O A D F B E F C .250 QC (6,4) Amps A B C D E F 3A 3.310 (84,1) 2.000 (50,8) 1.500 (38,2) 2.940 (74,7) 2.500 (63,5) .550 (14,0) 6A 3.310 (84,1) 2.000 (50,8) 1.500 (38,2) 2.940 (74,7) 2.500 (63,5) .550 (14,0) 10A 4.70 (119,4) 2.250 (57,1) 1.750 (44,4) 4.250 (107,9) 3.750 (95,3) .550 (14,0) A Amps A B C D E 3A 3.310 (84,1) 2.000 (50,8) 1.500 (38,1) 2.940 (74,7) 2.500 (63,5) 6A 3.310 (84,1) 2.000 (50,8) 1.500 (38,1) 2.940 (74,7) 2.500 (63,5) 10A 4.70 (119,4) 2.250 (57,1) 1.750 (44,4) 4.250 (107,9) 3.750 (95,3) D L I N E L O A D B 4.00 E .250.062 (6,35) Typ. (101,6) Min. C SINGLE PHASE FILTERS F1400BB (3, 6 and 10Amp) Dimensions High Performance L I N E No. 18 Gauge Wire F1400CA (3 and 6Amp) Dimensions (1) 5mm x 20mm Fuse (not included) E L I N E 6-32 Tap 2-Places L O A D A C Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. B Refer to Page 40 for Standard Mounting Cutouts D .250 QC (6,4) Amps A B C D E 3A 2.880 (73,1) 2.120 (53,8) 1.500 (38,1) .550 (14,0) .565 (14,3) 6A 2.880 (73,1) 2.120 (53,8) 1.500 (38,1) .550 (14,0) .565 (14,3) Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 17 Standard Mounting Cutouts F1200CA, F1300CA, F1400CA, F1500CA, F1600CA, F1700CA F1500FA, F1600FA, 1.20 (30.5) .187 (4,75) .638 (16,21) .140 Dia. (3,55) 2 Holes .09 R (2,29) 1.275 (32,39) .90 (22,9) .140 Dia. (3,55) 2 Holes 1.575 (40,0) .234 (5,94) 1.145 (29,08) .450 (11,43) for mounting from back side 1.417 (36,0) SINGLE PHASE FILTERS How to Order The Curtis part numbering system is made up of four elements. Each element denotes a specific requirement (mechanical or electrical) which, when properly sequenced, fully identifies the required catalog filter. As shown, the first five alpha/numeric characters denote the series type; the sixth character (alpha) denotes the type of line termination; the seventh character (alpha) denotes the type of load termination; the last two characters (numeric) denote the current rating. Compose your part number as follows: Select the series required, add two alpha character for the line and load termination, followed by two numeric characters for the required current rating. For example, F1100AB06 completely identifies an F1100 series filter with quick connects on line side and wire leads on load side, with a 6-amp rating. F1100 X X SERIES PE = Power Entry PM = Medical Power Entry LINE TERMINATION A = Quick Connects B = Wire Leads C = IEC Connector D = Screw Terminals (20 & 30 amp only) F = Fused IEC P = Printed Circuit Pins W= Dual Fused IEC J = Switched IEC 40 www.curtisind.com LOAD TERMINATION A = Quick Connects B = Wire Leads D = Screw Terminals (20 & 30 amp only) P = Printed Circuit Pins S = Solder Tab X CURRENT RATING 01 = 1 Amp 03 = 3 Amps 06 = 6 Amps 10 = 10 Amps 15 = 15 Amps 20 = 20 Amps 30 = 30 Amps F1300CP, F1600CP 1.500 (38,1) .600 (15,2) N .700 (17,8) 1.400 (35,6) .062 Hole Dia. (1,57) 5 Holes L F5500/5600/5700 SERIES 1.575 (40,01) .90 (22,8) .140 Dia. (3,55) 2 Holes .234 R. (5,94) (Typ.) Curtis Industries A Division of Powers Holdings, Inc. 1.20 (30,48) Specifications subject to change. Dimensions are shown for reference purposes only.