40 Industrial Way East, Eatontown , NJ 07724 [USA]
Phone: (732) 460-0212, Fax: (732) 460-0214
www.aeroflex.com/acc, email: acc-sales@aeroflex.com
Parameter Specification Units
Frequency Range (min) 0.10 – 3000 MHz
Peak Input Power (max) 1.0 kW
CW Input Power (max) 60.0 W
Flat Leakage (CW Power) (max) 13.0 dBm
Insertion Loss (max) 0.40 dB
VSWR (max) 1.25:1 ratio
Specifications:
Features
• Low Insertion Loss
• Low Leakage Power Circuit Protection
• High CW Power Handling
• Assorted Package Styles
Revision Date: 2/23/2011
ACLM-4896
Coaxial High Power Limiter
Notes:
Test conditions: Full rated power for 30 seconds.
Insertion loss is slightly higher for the high power
versions.
Most models are broadband and will operate
beyond the frequency ranges shown.
Typical leakage is 3dB below the maximum shown.
Power handling is linearly derated from full power at
+25°C to zero power at +150°C.
All models require external DC blocks for proper
operation.
Environmental Specifications:
Designed to meet:
MIL-E-5400, MIL-STD-202, MIL-E-16400
Operating Temp: -55°C to +125°C
Storage Temp: -65°C to +150°C
Humidity: MIL-STD-202F, M103, Cond B
Shock: MIL-STD-202F, M213, Cond B
Altitude: MIL-STD-202F, M105, Cond B
Vibration: MIL-STD-202F, M204, Cond B
Thermal Shock: MIL-STD-202F, M107, Cond A
Temperature Cycle: MIL-STD-202F, M105C, Cond D
SCREENING:
Internal Visual per MIL-STD-883, Method 2017
Temperature Cycle: -65°C to +100°C, 10 cycles
OPTIONAL HIGH-REL SCREENING
(Ref MIL-PRF-38534):
Stabilization Bake per MIL-STD-883, Method 1008
Temperature Cycle per MIL-STD-883, Method 1010
Constant Acceleration per MIL-STD-883, Method
2001
Burn-in per MIL-STD-883, Method 1015
Leak Test per MIL-STD-883, Method 1014
External Visual per MIL-STD-883, Method 2009