J-8
CT Series
DAQMaster(integrated device management program)
Upgraded functions
DIN W48×H48mm, W72×H36mm, W72×H72mm counter/timer
● DAQMaster is a integrated device management program for convenient
management of parameters and multiple device data monitoring.
● Visit our website (www.autonics.com) to download user manual and
integrated device management program.
Item
Digit
Size
Output
Power supply
Communication 출출 출출출
Ordering information
CT 2P6 M 4 T-
No mark None
T RS 485
4 100-240VAC 50/60
2 24VAC 50/60 / 24-48VDC
4 9999(4digit)
6 999999(6digit)
CT Counter/Timer
2P Dual preset
1P Single preset
I Indicator
S DIN W48×H48mm
Y DIN W72×H36mm
M DIN W72×H72mm
A shaded ( ) part is upgraded or added function.
< DAQMaster screen >
4digit type does not exist
in the indicator type.
Upgrade
Available to set 6 digits(0.00001 to 999999) prescale value
(4digit : 0.001 to 9999)
● Built-in Modbus communication function(Communication model)
Available to set the One-Shot output time in 10ms.
(0.01sec. to 99.99sec.)
● Increase contact capacity to 5A(CTS, CTM Series)
Available to set Count Start Point.(Initial value)
● Improved to select memory protection function in the indicator
Added BATCH counter function(CTM Series)
Added Counter Up-1 / Up-2 / Down-1 / Down-2 input modes
Added Counter TOTAL / HOLD operation modes in the indicator
Added Timer TOTAL / HOLD / On Time Display operation
modes in the indicator
Added Timer INT2 / NFD / NFD.1 / INTG output modes
Added Timer range 999.999s / 9999m59 / 99999.9h
Please read “Caution for your safety” in operation
manual before using.
Item Minimum requirements
System IBM PC compatible computer with Intel Pentium
or above
Operating system
Microsoft Windows 98/NT/XP/Vista/7
Memory 256MB or more
Hard disk More than 1GB of free hard disk space
VGA 1024×768 or higher resolution display
Others RS-232 serial port(9-pin), USB port
J-9
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
Communication specification
Specications
Series CTS CTY CTM
Digit 4 6 6 6
Model
Dual Preset CT4S-2P CT6S-2P CT6Y-2P CT6M-2P
Single Preset CT4S-1P CT6S-1P CT6Y-1P CT6M-1P
Single Preset
-
CT6S-1 CT6Y-1 CT6M-1
Digit
Size
Single Preset 11mm 10mm 10mm 13mm
Single Preset 8mm 7mm 7mm 9mm
Power
Supply
Single Preset 100-240VAC 50/60Hz
Single Preset 24VAC 50/60Hz / 24-48VDC
Allowable voltage range
90 to 110% of rated voltage(AC Power type)
Power
consumption
Single Preset Max. 12VA
Single Preset AC: Max. 10VA / DC: Max. 8W
INA/INB Max. counting speed Selectable 1cps / 30cps / 1kcps / 5kcps / 10kcps
Min. input
signal width
Counter Reset signal : Selectable 1ms, 20ms
Timer INA, INB RESET : Selectable 1ms, 20ms
INA, INH, RESET, INHIBIT, BATCH
RESET : Selectable 1ms, 20ms
Input Selectable voltage input or No-voltage input
[Voltage input] Input impedance is 5.4kΩ, 'H' level : 5-30VDC, 'L' level : 0-2VDC
[No-voltage input] Short-circuit impedance : Max. 1kΩ, Residual voltage : Max. 2VDC
One-shot output Count, timer : Selectable 0.01s to 99.99s
Control
output
With-
out
com.
Contact
output Dual preset : SPST(1a) 2EA
Single preset : SPDT(1c) 1EA Dual preset : SPST(1a) 1EA, SPDT(1c) 1EA
Single preset : SPDT(1c) 1EA
Solid state
output Dual preset : 1NPN open collector
Single preset : 1NPN open collector
Dual preset:3NPN open collector
Single preset:2NPN open collector
With-
out
com.
Contact
output Dual preset : SPST(1a)2EA
Single preset : SPDT(1c)1EA
Dual preset: SPST(1a), SPDT(1c)
Single preset: SPDT(1c)
Solid state
output
-
Dual preset: -
Single preset:1NPN open collector
Dual preset:2NPN open collector
Single preset:2NPN open collector
With-
out
com.
Contact
output 250VAC 5A resistive load 250VAC 3A resistive load 250VAC 5A resistive load
Solid state
output 30VDC Max. 100mA Max.
External sensor power 12VDC ±10%, 100mA Max.
Memory retention 10years(When using non-volatile semiconductor memory type)
Timer
Repeat error
Power ON Start : Max. ±0.01% ±0.05 sec
Signal Start : Max. ±0.01% ±0.03 sec
SET error
Voltage error
Temperature error
Insulation resistance Min. 100MΩ(500VDC Megger)
Dielectric strength 2,000VAC 50/60Hz for 1minute
Noise strength (AC Power) ±2kV the square wave noise(pulse width:1) by the noise simulator
Vibration Mechanical 0.75mm amplitude at frequency of 10 to 55(for 1 min.)Hz in each of X, Y, Z directions for 1 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 minutes
Shock Mechanical 300m/s²(approx. 30G) in each of X, Y, Z directions for 3 times
Malfunction 100m/s²(approx. 10G) in each of X, Y, Z directions for 3 times
Relay
Life cycle
Mechanical Min. 10,000,000 operations
Electrical Min. 100,000 operations
Protection IP65(Front panel only)
Environment
Ambient
temperature -10 to 55, storage : -25 to 65
Ambient
humidity 35 to 85%RH, storage : 35 to 85%RH
Approval
Unit weight Approx. 159g Approx. 149g Approx. 253g
Environment resistance is rated at no freezing or condensation.
Protocol Modbus RTU(16bit CRC)
Connection method
RS485
Application standard
Compliance with EIA RS485
Number of connections
31, it is available to set address 1 to 127
Communication method
Half Duplex
Synchronous method
Asynchronous
Communication distance
within max. 800meter
Communication speed
2,400/4,800/9,600/19,200/38,400bps(Factory default : 9,600bps)
Response waiting time
5 to 99ms(Factory default : 20ms)
Start bit 1bit(Fixed)
Data bit 8bits(Fixed)
Parity bit None, Even, Odd(Factory default : None)
Stop bit 1, 2bit(Factory default : 2bit)
J-10
CT Series
Connections
CT S-2P
CT S-1P
CT6S-I
CT6Y-2P
CT6Y-1P
Be careful that connections are different
between communication model and
non-communication model when wiring.
RS485
RS485
OUT
RS485
RS485
RS485
A(+)
A(+)
A(+)
A(+)
A(+)
B(-)
B(-)
B(-)
B(-)
B(-)
12VDC 100mA
INB / INH
INA
INA
INB / INH
12VDC 100mA
INA
INB / INH
12VDC 100mA
INA
INB / INH
12VDC 100mA
INA
INB / INH
12VDC 100mA
12VDC 100mA
INB / INH
INA
12VDC 100mA
INB / INH
INA
12VDC 100mA
INB / INH
INA
12VDC 100mA
INB / INH
INA
12VDC 100mA
INB / INH
INA
250VAC 5A
RESISTIVE
250VAC 5A
RESISTIVE
250VAC 5A
RESISTIVE
250VAC 5A
RESISTIVE LOAD
250VAC 3A
RESISTIVE LOAD
250VAC 3A
RESISTIVE LOAD
250VAC 3A
RESISTIVE LOAD
250VAC 3A
RESISTIVE
250VAC 3A
RESISTIVE
250VAC 3A
RESISTIVE LOAD
SOLID
STATE OUT
30VDC
100mA
SOLID
STATE OUT
30VDC
100mA
SOLID
STATE OUT
30VDC
100mA
250VAC 5A
RESISTIVE LOAD
NO
NC
NCNC
NOCOM
COM
COMCOM
OUT
OUT
OUT
OUT2 OUT1 OUT2
OUT OUT
COMNC
NO
NONO
NC
250VAC 5A
RESISTIVE
OUT2
30VDC
100mA
OUT
30VDC
100mA
OUT
OUT2
OUT2
OUT2
OUT1
OUT1
OUT1
RESET
0VDC
RESET
0VDC
RESET
0VDC
0VDC RESET
0VDC RESET0VDC RESET
0VDC RESET
RESET
0VDC
RESET
0VDC
RESET
0VDC
11
11
1
11
11
1
CT S-2P T
CT S-1P T
CT6S-I T
CT6Y-2P T
CT6Y-1P T
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
J-11
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
CT6Y-I
CT6M-2P
CT6M-1P
CT6M-I
CT6Y-I T
CT6M-2P T
CT6M-1P T
CT6M-I T
12VDC 100mA
INB
INA
12VDC 100mA
INB
INA
12VDC 100mA
INB
INA
12VDC 100mA
INB
INA
INA
INB / INH
12VDC 100mA
INA
INB / INH
12VDC 100mA
OUT2
OUT1
OUT2
OUT
OUT
0VDC RESET 0VDC RESET
1
2
2
22
1
1
1
1
1
RS485
RS485
RS485
RS485
250VAC 5A
RESISTIVE
LOAD
250VAC 5A
RESISTIVE
LOAD
250VAC 5A
RESISTIVE
LOAD
30VDC
100mA
30VDC
100mA
INHIBIT
RESET
INHIBIT
RESET
INHIBIT
RESET
INHIBIT
RESET
BATCH
BATCH
0VDC
0VDC
0VDC 0VDC
BATCH RESET
BATCH RESET
SOLID STATE OUT
SOLID STATE OUT
NCCOM
COM
COM
NO
NO
NO
NO
B(-)
B(-)
B(-)
B(-)
A(+)
A(+)
A(+)
A(+)
1: Source
- AC Power: 100-240VAC 50/60Hz
- AC/DC Power: 24-48VDC, 24VAC 50/60Hz
2: INHIBIT Signal
- Counter operation: If INHIBIT signal is applied,
count input will be prohibited.
- Timer operation: If INHIBIT signal is applied, time
progressing will stop.(HOLD)
12VDC 100mA
INB
INA
OUT
OUT
2
1
250VAC 5A
RESISTIVE
LOAD
30VDC
100mA
INHIBIT
RESET
OUTPUT
COMMON BATCH
0VDC
BATCH RESET
SOLID STATE OUT
COM
NO NO
12VDC 100mA
INB
INA
OUT2
OUT1
OUT1 OUT2
1
2
250VAC 5A
RESISTIVE
LOAD
250VAC 5A
RESISTIVE
LOAD
30VDC
100mA
INHIBIT
RESET
OUTPUT
COMMON BATCH
0VDC
BATCH RESET
SOLID STATE OUT
NCCOM COM
NO NO
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
J-12
CT Series
CTS Series
CTS Series CTY Series CTM Series
CTY Series
CTM Series
48
85
72 77
85
86
1
1
7
4
5
3
6 2
8
9
6
13
1
12
10
10
10
11
2
5
4
3
7
8
9
2
5
4
6
3
7
8
9
72 10
Min. 91
Min. 55
Min. 62
6
9010
Min. 40
30 45
60
67
36
Min. 91
Min. 91
68+0.7
0
68+0.7
0
68 +0.7
0
45.5 +0.5
0
45.5 +0.5
0
31.5
+0.6
0
Dimensions
Parts description
● Panel cut-out
● Panel cut-out
● Panel cut-out
● Bracket
1. Count indicator(Red LED)
- Run mode
: Count mode-Indicates count value.
Timer mode-Indicates time progressing.
- Function setting mode
: Indicates function setting mode.
2. Preset value indicator (Yellow-Green LED)
- Run mode: Indicates preset value.
- Function setting mode: Indicates setting value1.
3. Key Lock : Lights when setting key lock.
4. The operation of counter indicator
5. The operation of timer indicator
TMR LED flashes when the timer is operating.
TMR LED lights when the operating time stops.
6. Check preset value and display change of it
PS1 LED lights when checking or changing the setting value1
.
PS2 LED lights when checking or changing the setting value2.
7. Output(OUT1, OUT2) indicator
OUT1 lights when output1 is on.
OUT2 lights when output2 is on.
8. Reset key
By pressing RST key in Run mode, the count value is initialized and
output is returned.
By pressing
RST
key in BATCH counter mode,BATCH count valu
e
resets.
9. Mode key
-
By pressing
MD
key for 3sec (parameter setting)/ 5sec (communication)
in RUN mode, it moves to function setting mode.
- By pressing
MD
key in function setting mode, select function setting
mode. By pressing MD key over 3 sec., it moves to Run mode.
- By pressing
MD
key over 1 sec. in function setting checking mode,
it
moves to Run mode.
10. Set key
:
To enter into setting value(PS1, PS2) change status and shift digit
of setting value(PS1, PS2).
:
To decrease setting value in setting value change mode, change
setting value in function setting mode, move down checked
value in function setting check mode.
:
To increase setting value in setting value change mode, change
setting value in function setting mode, move up checked value in
function setting check mode. By pressing MD key over 1 sec.
in Run mode, enters into function setting check mode.
11. BATCH key
By pressing BA key in run mode to enter into BATCH counter
indication mode.
12. BATCH output indicator(red LED)
13. BATCH setting value checking and changing indicator
(yellow-green LED)
Lights when checking and changing BATCH setting value.
(unit:mm)
Model Changed Notice
CT6Y-1P
PS2→PS
OUT2→OUT
There are no
PS1, OUT1
LEDs.
CT6S-1P
CT4S-1P
CT6M-1P
CT6Y-I
PS2→PS
There are no
PS1, OUT1
OUT2 LEDs.
CT6S-I
CT6M-I
The indicator type does not exist
in CT4S model.
J-13
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
3. Select input logic by using input logic switch(SW1)
inside Counter/Timer.
1. The power must be cut off.
2. Detach the case from the body.
(CTS, CTY Series)
Input connections
Input logic Selection[No-voltage input(NPN)/Voltage input(PNP)]
No-voltage input(NPN)
Voltage input(PNP)
● Solid-state input(Standard sensor : NPN output type sensor) ● Contact input
● Solid-state input(Standard sensor : PNP output type sensor) ● Contact input
1: INA, INB/INH, RESET, INHIBIT, BATCH RESET input part
2: Counting speed: 1 or 30cps setting(Counter)
1: INA, INB/INH, RESET, INHIBIT, BATCH RESET input part
2: Counting speed: 1 or 30cps setting(Counter)
* Case detachment
Squeeze toward and pull toward as shown
in picture.
Please check if the power is cut off.
5.4Ω
5.4
5.4Ω
5.45.4Ω
5.4Ω
+12V
+12V
+12V
+12V +12V
+12V
0V 0V
0V 0V 0V
0V
Inner circuit
of input part
Inner circuit
of input part
Inner circuit
of input part
Inner circuit
of input part
Inner circuit
of input part
Inner circuit
of input part
Sensor
Sensor
(NPN output)
(PNP output)
(NPN open collector output)
(PNP open collector output)
Sensor
Sensor
Brown
Brown
Brown
Brown
Black
Black
Black
Black
1
1
1
1
2
2
Blue
Blue
Blue
Blue
Counter/Timer
CT Series
Counter/Timer
CT Series
Counter/Timer
CT Series
Counter/Timer
CT Series
Counter/Timer
CT Series
Counter/Timer
CT Series
● Select No-voltage
input(NPN)
● Select voltage
input(PNP)
PNPPNP
<CTS Series> <CTY Series> <CTM Series>
NPN
(Factory default)
NPN
4. Push a case in the opposite direction of 2-.
5. Then apply the power to Counter/Timer.
J-14
CT Series
Output connections
Factory default
Error display
Contact output Solid-state output
Use proper load not to exceed the capacity.
Use proper load and power for load not to excess ON/OFF
capacity(30VDC Max. 100mA max.) of solid state output.
Be sure not to apply reverse polarity of power.
1: When use inductive load(Relay etc), surge absorber
(Diode, varistor etc) must be connected between both
sides of the load.
1
Counter/Timer
CT Series
Counter/Timer
CT Series
Load
Load
(+)
(
-
)
Power
for load
(DC)
(Power of load)
Error display Errors Output status How to return
Failed in data loading
for exsiting setting
values
OFF Power on again
Parameter Factory default
Input mode (ㅑIN)UP/Down-C (UD-C)
Output mode (OUtM) F (F)
CPS (CPS)30cps (30)
Indication mode (indicator type)(DSpM) TOTAL (TOTAL)
OUT2 output time (OUt2)Hold (HOLD)
OUT1 output time (OUt1)100ms (0)10)
Decimal point (DP)------
Min. reset time (RST)20ms (20)
Input logic (SIG)NPN (NPN)
Prescale decimal point (ScDP)6digit type : -.-----, 4digit type : -.---
Prescale value (SCL)6digit type : 1.000004digit type : 1.000
Start Point setting (STRT)000000
Counting memory (DATA)Clear (SLR)
Lock key (LOCK)Lock off (lOFF)
Preset value 1 (PS1) 1000 (1000)
Preset value 2 (PS2) 5000 (5000)
Time range (HOUR/MIN/SEC)6Digit type: 0.001s-999.999s, 4Digit type: 0.001s-9.999s
Up/Down mode (U-D)UP (UP)
Indication mode(Indicator type)(DSpM) TOTAL (TOTAL)
Memory protection(Indicator type)
(DATA)CLEAR (SLR)
Output mode (OUtM)OND (OND)
OUT2 output time (OUT2)Hold (HOLD)
OUT1 output time (OUT1)100ms (0)10)
Input logic (SIG)NPN (NPN)
Input signal time (ImT)20ms (20)
Lock key (LOCK)Lock off (lOFF)
Preset value 1 (PS1) 1000 (1000)
Preset value 2 (PS2) 5000 (5000)
Communication address (ADDR)01 (001)
Communication speed (BPS)9600bps (96)
Communication parity (PRTY)NONE (NONE)
Communication stop bit (STP)2 (2)
Response waiting time (RSWT)20ms (20)
Communication writing (COmY)Enable (ENA)
CounterTimer
Communication
PS1
PS2
EEP
FAIL
J-15
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
Change of BATCH
setting value.
Change of
preset
Function setting
check mode
Operations and functions
Change of preset(Counter/Timer)
Function setting check mode
Change of BATCH setting value
Switching display function in preset indicator
Reset
Even if changing the preset value, input operation and output control will continue. In addition, the preset value could
be set to 0 and 0 preset value turns ON. According to output mode, preset value could not be set to 0. (When setting to 0,
preset value "0" will flash 3 times.)
● Setting value of function setting mode can be confirmed using the and keys.
Setting value 1(PS1) and setting value 2(PS2) are displayed each time pressing key in dual preset model.
(In timer, it is available for output mode.)
In BATCH counter indication mode, 'BATCH counter value' is displayed in count indicator and 'BATCH counter
setting value' is displayed in preset indicator.
If pressing key in Run mode, it will enter into BATCH counter indication mode.
● In Run mode or function setting mode, if key or applying the signal to the RESET terminal on the back side,
present value will be initialized and output will maintain off status. When selecting voltage input(PNP), short no. 10
and no. 12 terminals, or when selecting no-voltage input(NPN), short no. 11 and no. 12 terminals to reset.
1. If no key is touched for 60 sec., the counter will
return to RUN mode without being restored.
BATCH counter is
available for
CT6M-1P/2P only.
In Run mode, it enters into the
preset value setting mode
using key. 'PS1' LED lights
and first digit of preset value
flashes.
It enters into
settingvalue change
mode using key.
(BA.S lights, first digit
of setting value flashes.)
BATCH value is set to '200'
using , and keys,
then press key to complete
BATCH setting value and
move to BATCH counter
indication mode.
The preset value is set to ' '
using , and keys, then
press key to enter into the
PS2 setting mode.
The preset value is set to '200'
using , and keys, then
press key to complete PS2
setting and return to Run mode.
Press key to save set value after changing the setting value. Then, it moves to next parameter or returns
to RUN mode. However, if no key is touched for 60 sec., it will return to RUN mode without being saved.
BATCH RESET
RESET
BATCH counter
indication mode
3sec.: Enters into parameter 1 group
5sec.: Enters into parameter 2 group
Function
setting mode
3sec.
3sec. 5sec.
1
1
1.
1. 2.
2. 3.
1sec.
1sec.
RUN
mode
BATCH Counter(For CT6M-1P /CT6M-2P model only)
J-16
CT Series
BATCH counter operation
BATCH counting operation
BATCH output
BATCH reset input
Application of BATCH counter function
● BATCH counting value is increasing until BATCH reset signal applied. BATCH counting value will be circulated when it is
over 999999.
1) BATCH counting operation in Counter : Counts the number of reaching setting value of CT6M-1P or reaching dual
setting value of CT6M-2P
2) BATCH counting operation in Timer: Counts the number of reaching setting time.
(In case of "FLK" output mode, count the number of reaching T.off setting time
and T.on setting time.)
● If input signal is applied while changing BATCH setting value, counting operation and output control will be performed.
If BATCH count value equals to BATCH setting value, BATCH output will be ON and maintain ON status
until BATCH reset
signal is applied.
When the power is cut off then resupplied in status of BATCH output is ON, BATCH output maintains ON
status until
BATCH reset signal is applied.
● If pressing reset button or applying the signal to BATCH reset terminal on the back side panel, BATCH counting value will
be reset. When selecting voltage input(PNP), short no. 10 and no. 14 terminals, or when selecting no-voltage input(NPN),
short no. 11 and no. 14 terminals to reset.
● When BATCH reset is applied, BATCH counting value maintains at 0 and BATCH output maintains in the OFF status.
ON
OFF
ON
OFF
ON
OFF
Preset output
Batch Reset
999999
Batch setting value
0
Power
BA.O LED
Batch
output
● Counter
In case, put 5 products in a box then pack the boxes when
they reaches to 200.
- Counter preset setting value="5", BATCH setting
value="200"
- When the count value of counter reaches to the preset
value "5", the control output(OUT) will be on, and at
this time the count value of the BATCH counter will be
increased by "1". The control box which is received the
control output (OUT) repeatedly controls conveyor to
move the full box and to place the next empty box for
standby. When the BATCH count value reaches to "200",
BATCH output will be ON. Then the control box stops
conveyor and provides a control signal for packing.
● Timer
Fills milk into the bottle for 3sec.(setting time) When 500
bottles are filled, BATCH counting finish lamp is turned on.
(Setting time : 3sec., BATCH setting value : 500)
BATCH output
Operation valve
(Open valve
for 3sec.)
Control
output
Control the
operation valve
Bottle sensing
sensor
CT6M-
1P4
Control
box
Count input BATCH output
Control
output
(OUT)
CT6M-1P4
Preset value = 5
Control box
Current BATCH count value = 3
Third
box
Second
box
First
box
Control signal
for conveyor
Control signal
for packing
BATCH output
lamp
BATCH counting
nish lamp
Productivity :
500bottels
Lamp on when
it is completed.
J-17
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
3sec. 3sec. 5sec. 3sec.
Memorize
counting value
(DATA)
Communication
OUT2 output time
(OUT2)
OUT1 output time
(OUT1)
Decimal point
(DP)
Start Point value
(STRT)
Run mode
Parameter group2
(GRp2)
Min. reset time
(RST)
Prescale value
(RST)
Input logic
(SIG)
Prescale decimal
point
(ScDP)
Memorize counting value
(DATA)
Lock key
(LOCK)
Output mode
(OUtM)
OUT2 output time
(OUT2)
OUT1 output time
(OUT1)
Input logic
(SIG)
Input signal time
(InT)
Lock key
(LOCK)
Parameter group1
(GRp1)
Input mode
(IN)
Output mode
(ㅑㅑㅑOUtM)
Indication mode
(DSpM)
Max. counting speed
(CPS)
Counter/Timer
(C-T)
Counter
(COUN)Timer
(T1ME)
,
1
33
3
3
2
3
1
3
3
3
3
3
3
2
3
3
3
3
3
Up/Down mode
(U-D)
Time range
(HOUR/MIN/SEC)
Indication mode
(DSpM)
Com. address
(ADDR)
Com. speed
(BPS)
Com. parity
(PRTY)
Com. stop bit
(STP)
Response
waiting time
(RSwT)
Com. writing
(COmW)
Function setting mode
Flow chart for function setting mode
If changing setting value of parameter group1, display value and output will be initialize.
Press key over 3sec./5sec. in RUN mode to enter into parameter 1 group/ parameter 2 group.
Press key over 3 sec. in function setting mode to return RUN mode.
Input operation and output control can be set in function setting mode.
If changing set value of 3 marked parameters in function setting mode, OUT1 and OUT2 output will be turned OFF and
then the current value is reset.
Parameter 2 group is not available to non-communication models.
1: Indicator
2: Output type
3: If changing the setting
value of function, OUT1,
OUT2 will turn OFF and
return to Run mode, then
present value resets.
Counter
- Single preset model has no "OUT1 output setting time" setting function
mode and OUtT is displayed in "OUT2 output time" setting function mode.
- In case of DN, DN-1, DN-2 input mode, there is no "Start Point value" setting
function mode.
- In case of
F
or
N
output mode, there is no "OUT2 output time" setting function
mode.(Fixed to HOLD)
- In case of S, T or D output mode, there is no "OUT2 output time" setting
function mode.
Timer
- In case of
FLk1
,
FLk2
or
INtG
output mode and
OND
,
OND1
,
OND2
output
mode of single preset model,
OUtT
is displayed in "OUT2 output time" function
setting mode and there is no "OUT1 output time" function setting mode.
- The output modes except for
OND
,
ONd1
,
ONd2
and INt2
output mode there is no
"OUT1 output time" function setting mode.
J-18
CT Series
Parameter setting(Counter)
1. Explanation of decimal point and prescale decimal point setting
- Decimal point setting : Set decimal point of the display value on front indicator.
- Prescale decimal point setting : Set prescale decimal point of counting regardless of decimal point of display value
on front indicator.
( key: To select setting mode, or key: To change setting value)
Setting mode How to set
Counter/Timer
ㅑㅑC-T COUN TIME
Input mode
IN
UD-C UP UP-1 UP-2 DN DN-1 DN-2 UD-A UD-B
Output mode
OUtM
Indication mode
DSpM
Max. counting speed
CPS 30 1K SY 10K 1
OUT2 output time
OUT2
OUT1 output time
OUT1
※1
Decimal point
DP
Min. reset time
RST 1 20
Input logic
SIG
※1
Prescale
decimal point
ScDP
● 6digit type
● 4digit type
Prescale value
SCL
Start Point Value
STRT
Memory protection
DATA CLR REC
Lock key
LOCK
LOFF LOc1
LOc3 LOc2
Set OUT1 one-shot setting time
Time range: 0.01 to 99.99 sec., Hold
HOLD is displayed by pressing key 4 times.
Set OUT2 one-shot output time.
Setting range: 0.01 to 99.99 sec.
It does not appear if F, N output mode is selected.
In case of the indicator, indicate mode selection (DSpM)is displayed.
It is added that the function which can set the preset value when selecting
HOLD.(Refer to J-22 page 'Counter operation of the indicator'.)
CONE: COUNTER
TIME: TIMER
If output mode is set to D when max. counting
speed is set to 5Kcps, 10Kcps, max. counting
speed is automatically set to 30cps. (Factory
default setting)
Counting speed is that of one by one(1:1) duty ratio of INA or INB input signal,
and it is applied in INA and INB at thesame time.
In case of setting D in output mode, you can choose 1cps, 30cps, 1Kcps.
: To shift the ashing digit.
: To change the prescale value.
: To shift the ashing digit.
: To change the Start Point value.
Setting range of prescale value
6digit type: 0.00001 to 99999.9
4digit type: 0.001 to 999.9
Refer to the J-20 page ' Prescale function'.
Setting range of Start Point value (Connected with decimal point setting)
6digit type: 0.00000 to 999999
4digit type: 0.000 to 9999
Refer to the J-20 page ' Start Point function'.
CLR: Initializes count value when power is off.
REC : Memorizes count value at the moment of power off.
LOFF:Cancellation of the lock mode.
LOc1: Locks key.
LOc2: Locks , , keys.
LOc3: Locks , , , keys.
Setting the decimal point is applied same to counting
value and setting value.
Set the min. external RESET signal width.
Check input logic value(PNP, NPN).
NPN: No-Voltage input
PNP: Voltage input
Prescale decimal point position is not set below the decimal
point setting digits (DP).
unit: ms
: To shift ashing digit position of OUT2
output time value.
: To change OUT2 output time value.
: To shift ashing digit position of OUT1
output time value.
: To change OUT1 output time value.
UP, UP-1, UP-2 or DN, DN-1, DN-2 input mode
F N C R K P Q A
UD-A, UD-B, UD-C input mode
F N C R K P Q A S T D
● In case of the indicator
HOLD TOTAL
● 6digit type
------ -----.- ----.-- ---.--- --.---- -.-----
● 4digit type
---- ---.- --.-- -.---
In case that output mode is F, N there is no "OUT2 output time" setting mode. (Fixed to HOLD)
J-19
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
No
counting
No counting
No counting
No counting
No counting
No counting
No counting
0
0
0
n-1
n-1
n-1
n
n
n
n-2
n-2
n-2
n-3
n-3
n-3
n-4
n-4
n-4
n-5
n-5
n-5
n-6 n-7
0
0
0
0
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
INA
INA
INA
INA
INA
INA
INB
INB
INB
INB
INB
INB
Count
value
Count
value
Count
value
Count
value
Count
value
Count
value
Count
value
012
34
32123
4
0
1
1
3
3
4
4
5
2
2
Input operation mode(Counter)
Input mode Count chart Operation
UP
(UP)
If INA is counting input, INB is
inhibition input.
If INB is counting input, INA is
inhibition input.
UP-1
(Up-1)
Counts when INA input signal is up.
()
INA: Counting input
INB: Inhibition input
UP-2
(Up-2)
Counts when INA input signal is
down. ( )
INA: Counting input
INB: Inhibition input
DN
(Down)
If INA is counting input, INB is
inhibition input.
If INB is counting input, INA is
inhibition input.
DN-1
(Down-1)
Count when INA input signal is up.
()
INA: Counting input
INB: Inhibition input
DN-2
(Down-2)
Counts when INA input signal is
down. ( )
INA: Counting input
INB: Inhibition input
UD-A
(Up/Down-A)
INA: Counting input
INB: Counting command input
When INB is L, counting Up.
When INB is H, counting Down.
0
0
H
L
H
L
INA
INB
1
3
67
45
2
J-20
CT Series
Input mode Count chart Operation
ㅑㅑUD-B
(Up/Down-B)
INA: Up counting input
INB: Down counting input
When both INA and INB are applied
to L->H, it will remain previous
counting value.
UD-C
(Up/Down-C)
When use A,B phase of encoder
with connecting to INA, INB, please
set counter input mode(
IN
) as
phase different input(
UD-C
).
0
0
00
1
2
3
2
1
2
3
H
L
H
L
H
L
H
L
B B B B
INA
INA
INB
INB
Count
value
Count
value
1
3323
4
4
22
Input operation mode(Counter)
Prescale function(Counter)
Start point function(Counter)
※ⓐ signal width should be over min. signal width and signal width should be over a half min. signal width.
If not, ±1 will occur.
This function is to set and indicate calculated unit for actual length, liquid measure, position etc. It is called "Prescale value"
for measured length, measured liquid, measured position, etc per 1 pulse.
For example, P is the number of pulses per 1 revolution of a rotary encoder and L is the desired length to be measured.
Prescale value is [the desired length (L)]/[the number of pulses (P) per 1 revolution of the rotary encoder.].
It is the length per 1 pulse of a rotary encoder.
This function is that start point value works as initial value when on counting mode.
● In case of
DN
,
DN-1
or
DN-2
in timer input mode, it is not available.
● When reset is applied, the present value is initialized to start point.
After count up in
C
,
R
,
P
,
Q
After count up in
To control conveyor position in 0.1mm, set the decimal point to tenth place(-----.-) in decimal point setting mode(DP) and
set the prescale decimal point to thousandth place(---.---) in prescale decimal point setting mode(ScDP)Then set prescale
value "0.069" in prescale setting mode (
SCL
).
Ex) Control length by the counter and the rotary encoder
The meaning of "H" and "L" Min. signal width by counting speed
High
Low
Ton, Toff : Min. signal width
INA
(INB) ON
Ton
T
Toff
ONOFF OFF
Rotary encoder
Cutter
Counter
Motor
Motor controlling
system
Roller
[In case of 22mm diameter(D) of roller connected
with the encoder of 1,000 pulse]
● Prescale value = π × Diameter of the roller(D)
The number of pulses per
1 revolution of the encoder
= 3.1416 × 22
1000
= 0.069mm/pulse
Voltage input (NPN)
No-Voltage input (PNP)
H 5-30VDC Short circuit
L 0-2VDC Open
Counting
speed
Min. signal
width
1cps 500
30cps 16.7
1kcps 0.5
5kcps 0.1
10kcps 0.05
J-21
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
RESET
999999
PRESET
2
1
0
PRESET
OUT1
OUT2
(OUT)
RESET
999999
PRESET
2
1
0
PRESET
OUT1
OUT2
(OUT)
RESET
999999
PRESET
2
1
0
PRESET
OUT1
OUT2
(OUT)
RESET
999999
PRESET
2
1
0
PRESET
OUT1
OUT2
(OUT)
RESET
999999
PRESET
2
1
0
PRESET
OUT1
OUT2
(OUT)
RESET
999999
PRESET
2
1
0
PRESET
OUT1
OUT2
(OUT)
RESET
999999
PRESET
2
1
0
PRESET
OUT1
OUT2
(OUT)
RESET
999999
PRESET
2
1
0
PRESET
OUT1
OUT2
(OUT)
Output operation mode(Counter)
The single preset type output(OUT) is operated as OUT2 of dual preset type.
OUT1 output could be set to 0 in all modes and 0 value output turns ON.
OUT2 output could not set to 0 in C(C). R(R), P(P) or Q(Q) output mode.
Output
mode
Input mode Operation
Up, Up-1, 2 Down, Down-1, 2 Up/Down A, B, C
F
(F)
After count-up, counting display
value increases or decreases until
reset signal is applied and retained
output is maintained.
N
(N)
After count- up, counting display
value and retained output are main-
tained until reset signal is applied.
C
(C)
When count-up, counting display value
will be reset and count simultaneously.
OUT1 retained output will be off after
OUT2 one- shot time.
The one-shot output time of OUT1
one-shot output time is operated
gardless of OUT2 output.
R
(R)
After OUT2 one-shot time,
counting
display value will be reset
and count
simultaneously.
OUT1 retained output will be off after
OUT2 one-shot time.
OUT1 one-shot output time is operated
regardless of OUT2 output.
K
(K)
After count-up, counting display
value increases or decreases until
RESET input is applied.
OUT1 retained output is off after
OUT2 one-shot time.
OUT1 one-shot output time is
operated
regardless of OUT2 output
.
P
(P)
After count-up, counting display value
is
maintained while OUT2 output is on.
Counting value is internally reset and
counts simultaneously.
When OUT2 output is off, displays
counting value while OUT2 is ON,
and it increases or decreases.
OUT1 retained output is off after
OUT2 one-shot time.
OUT1 one-shot output time is
oper-
ated regardless of OUT2 output.
Q
(Q)
After count-up, counting display
value increases or decreases during
OUT2 one-shot time.
OUT1 retained output is off after
OUT2 one-shot time.
OUT1 one-shot output time is operated
regardless of OUT2
output.
A
(A)
After count-up, counting display value
and OUT1 retained output are main-
tained until RESET input is applied.
OUT1 one-shot output time is oper-
ated regardless of OUT2 output.
One-shot output(0.01 to 99.99 sec.) One-shot output Retained output
Retained output
J-22
CT Series
Indicate
mode
(DSpM)
Count chart
Operation
In case of input mode is Up
(Up, Up-1, Up-2)
In case of input mode is Down
(Down, Down-1, Down-2)
TOTAL
(TOTAL)
Count value increases or decreases
until RESET input is applied.
When reaching max. count value or
min. count value, it will be reset and
count simultaneously.
HOLD
(HOLD)
Count value increases or decreases
until RESET input is applied, count
value indicator ashes when reaching
preset value(Up count) or 0(Down
count).
RESET RESET
PRESET
RESET
999999 999999
999999
999999
PRESET
0
0
0
-99999
0
The single preset type output(OUT) is operated as OUT2 of dual preset type.
The dual preset model OUT1 output is operated as one-shot or retained output.(except S, T, D mode)
OUT1 output could be set to 0 in all modes and 0 value output turns ON.
OUT2 output could not set to 0 in C(C), R(R), P(P) or Q(Q) output mode.
In case of UP/DOWN (UD-A, UD-B, UD-C) input mode, in-
dication mode (DSpM) of the conguration is not displayed.
Output mode Up/Down - A, B, C Operation
S
(S)
OUT1 and OUT2 keeps ON status in
following condition:
Counting display value PRESET1
Counting display value PRESET2
T
(T)
OUT1 output is off:
Counting display value PRESET1
OUT2 keeps ON status in following
condition:
Counting display value PRESET2
D
(D)
When counting display value is equal
to setting value(PRESET1, PRESET2)
only, OUT1 or OUT2 output keeps ON
status.
When setting 1kcps for counting
speed, solid state contact output
should be used.
RESET
RESET
RESET
RESET
999999
-99999
0
999999
999999
999999
-99999
-99999
-99999
0
0
0
PRESET2
PRESET2
PRESET2
PRESET1
PRESET1
PRESET1
OUT1
OUT1
OUT1
OUT2
(OUT)
OUT2
(OUT)
OUT2
(OUT)
Output operation mode(Counter)
Counter operation of the indicator(CT6S-I, CT6Y-I, CT6M-I)
Retained output Coincidence
output
● In case of the input mode is Command input (UD-A), Individual input(UD-B), Phase difference input(UD-C).
J-23
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
Parameter setting(Timer) ( key: To select setting mode or key: To change setting value)
Setting mode How to set
Counter/Timer
C-T COUN TIME
Timer range
HOUR/MIN/SEC
UP/DOWN mode
U-D UP DN
Indication mode
DSpM
TOTAL HOLD ONtD
Memory protection
DATA CLR REC
Output mode
OUtM
OND ONd1 ONd2 FLK FLk1 FLk2 INT
INTG NFd1 NFD OFD INt2 INt1
OUT2 output time
OUT2
key: To shift ashing digit position of OUT2 output time value.
key: To change OUT2 output time value.
Set OUT2 one-shot output time.
Setting range: 0.01 to 99.99sec.
HOLD is displayed by pressing key 4 times.
OUT1 output time
OUT1
key: To shift ashing digit position of OUT1 output time value.
key: To change OUT1 output time value.
Set OUT1 one-shot output time.
Setting range: 0.01 to 99.99sec., Hold
HOLD is displayed by pressing key 4 times.
Input logic
S1G
Input signal time
InT 1 20
Lock key
LOCK
LOFF LOc1
LOc3 LOc2
Used for the indicator only.
It is added that the feature which set the setting time when
selecting
HOLD or ONtD (Refer to J-28 page ' Timer
operation for the indicator').
COUN: COUNTER
TIME: TIMER
0.001s to
999.999s
0.1h to
99999.9h
0.001s to
9.999s
0.01s to
99.99s
1h to
9999h
0.1s to
999.9s
1m to
99h59m
1s to
9999s
1m to
9999s
1s to
99m59s
0.1m to
999.9m
0.01s to
9999.99s
1m to
9999h59m
0.1s to
99999.9s
1s to
99h59m59s
1s to
999999s
1m to
999999m
0.01s to
99m59.99s
0.1m to
99999.9m
0.1s to
999m59.9s
1s to
9999m59s
6digit type
4digit type
SEC
99(999
SEC
999(99
M S
995(99
SEC
9999(9
SEC
999999
HOUR
9999(9
H M
999959
H M 5
995959
MIN
999999
MIN
9999(9
M 5
999959
M S
9995(9
SEC
9959
SEC
(999
MIN
99(9
MIN
9999
H M
9959
HOUR
9999
SEC
9(99
SEC
99(9
SEC
9999
Used for the indicator only.
ㅑCLR : Initializes time value when power is off.
REC : Memorizes time value at the moment of power off.
UP: Time proceeds from 0 to the setting value.
DN: Time proceeds from the setting value to 0.
NPN: No-Voltage input
PNP: Voltage input
CTS/CTY: Set min. external INA, INH, RESET signal width.
CTM: Set min. external INA, RESET, INHIBIT,
BATCH RESET signal width.
LOFF: Cancellation of the lock mode
LOc1: Locks key.
LOc2: Locks , , keys.
LOc3 : Locks , , , keys.
Check input logic value(PNP, NPN).
[unit: ms]
J-24
CT Series
Output operation mode(Timer)
One-shot output
One-shot output Retained output
Retained output
Output mode Input mode Operation
OND
(OND)
Signal On Delay(Power Reset)
1) Time starts when INA signal turns on.
2) When INA signal turns off, time resets.
3) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
4) Control output operates as retained
or one-shot output.
ONd1
(OND.1)
Signal On Delay 1(Power Reset)
1) Time starts when INA signal turns on,
if INA signal is applied repeatedly,
only initial signal is recognized.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) Control output operates as retained
or one-shot output.
4) Only rst INA input signal is valid in
case INA input signal is repeatedly
applied.
ONd2
(OND.2)
Power On Delay(Power Hold) 1) Time starts when power turns on.
(There is no INA function.)
2) Time resets when reset turns on.
Time starts when reset turns off.
3) Control output operates as retained
or one-shot output.
4) It memorizes display value at the
moment of power off.
FLK
(FLK)
Flicker(Power Reset) 1)
Time starts when INA signal turns on.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) Control output operates as retained
output, output turns off for the T.off
time and turns off for the T.off time
and turns on for the T.on time repeat-
edly.
Ta+Tb = T.off setting time
4) The T.on time and T.off time must be
set individually.
5) In case of using the contact output, min.
setting time must be set over 100ms.
RESET
Setting time2
Setting time2
Setting time1
POWER
INA(START)
INH(INHIBIT)
Setting time1
0
0
UP
Display
Down
UP
Display
Down
UP
Display
Down
UP
Display
Down
OUT1
OUT2
RESET
Setting time2
Setting time2
Setting time1
POWER
INA(START)
INH(INHIBIT)
Setting time1
0
0
OUT1
OUT2
RESET
Setting time2
Setting time2
Setting time1
POWER
INA(START)
INH(INHIBIT)
Setting time1
0
0
OUT1
OUT2
RESET
POWER
INA(START)
INH(INHIBIT)
setting time
setting time
setting time
setting time
T.on
T.on
T.off
T.off
t a t-a
T.off T.offT.offT.on
T.on T.onT.on
Ta Tb
T.off
0
0
OUT2(OUT)
T1: Setting time1
T2: Setting time2
INA
T1
T2
OUT1
OUT2
(OUT)
T1: Setting time1
T2: Setting time2
INA
T1
T2
OUT1
OUT2
(OUT)
T.off T.offT.on
POWER
INA
OUT2
(OUT)
T1: Setting time1
T2: Setting time2
T1
T2
OUT1
POWER
HOLD
OUT2
(OUT)
Power Reset: There is no memory protection.(Initializes the display value when power is off)
Power Hold: There is memory protection.(Memorizes the display value at the moment of power off, indicates the memorized
display value when power is resupplied.)
J-25
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
Output mode Input mode Operation
FLk1
(FLK.1)
Flicker 1(Power Reset)
1) Time starts when INA signal turns on.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) Control output operates as retained
output.
4) In case of using the contact output, min.
setting time must be set over 00ms.
1) Time starts when INA signal turns on.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) Control output operates as one-shot
output.
4)
In case of using the contact output,
min. setting time must be set over
100ms.
FLk2
(FLK.2)
Flicker 2(Power Hold)
1) Time starts when INA signal turns ON and
the display value at the moment when
power is off is memorized.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) Control output operates as retained output.
4) Control output will be reversed when it
reaches to setting time.(At the initial
start, OUT2 control output is OFF).
5) In case of using the contact output, min.
setting time must be set over 100ms.
1) Time starts when INA signal turns ON and
the display value at the moment when
power is off is memorized.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) Control output operates as one-shot
output.
4) In case of using the contact output, min.
setting time must be set over 100ms.
Output operation mode(Timer)
RESET
RESET
RESET
RESET
Setting time
Setting time
Setting time
Setting time
Setting time
Setting time
Setting time
Setting time
POWER
POWER
POWER
POWER
Hold output
Hold output
One-Shot output
One-Shot output
INA(START)
INA(START)
INA(START)
INA(START)
INH(INHIBIT)
INH(INHIBIT)
INH(INHIBIT)
INH(INHIBIT)
0
0
0
0
0
0
0
0
Up
Display
Down
Up
Display
Down
Up
Display
Down
Up
Display
Down
OUT2(OUT)
OUT2(OUT)
OUT2(OUT)
OUT2(OUT)
t t t ta t-a
t t t
Power Reset: There is no memory protection.(Initializes the display value when power is off)
Power Hold: There is memory protection.(Memorizes the display value at the moment of power off, indicates the memorized
display value when power is resupplied.)
Retained output
Retained outputOne-shot output One-shot output
T:Setting time
POWER
T
Hold
T-c c T
INA
OUT2
(OUT)
T:Setting time
POWER
T
Hold
T-c c T
INA
OUT2
(OUT)
T:Setting time
POWER
T T T
INA
OUT2
(OUT)
T:Setting time
POWER
T T T
INA
OUT2
(OUT)
J-26
CT Series
Output mode Input mode
Operation
ㅑㅑINT
(INT)
Interval (Power Reset)
1) Control output turns ON and time starts
when INA signal turns ON.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) When it reaches setting time, indication
value and control output are reset
automatically.
4) Control output is ON when time is
progressing.
INt1
(INT.1)
Interval 1(Power Reset)
1) Control output turns ON and time starts
when INA signal turns ON.
2) When INA signal is on:
Power ON Time Start is operated
Power OFF Time Start is operated
3) When it reaches setting time, indication
value and control output are reset
automatically.
4) Control output is ON when time is
progressing.
5) INA input is ignored while time is
progressing.
INt2
(INT.2)
Interval 2(Power Reset)
1) Time starts when INA input is ON and
resets when INA input is OFF.
2) INA input is ON, OUT1 output is ON during
T1 or t1.
3) When it reaches setting time1, display
value resets and OUT2 output is ON
during T2 or t2 output time.
Output turns OFF when reaching the
setting time even if one-shot time
is longer than setting time.
Output operation mode(Timer)
RESET
RESET
RESET
Setting time
Setting time
Setting time1
Setting time1
Setting time2
Setting time2
Setting time
Setting time
POWER
POWER
POWER
INA(START)
INA(START)
INA(START)
INH(INHIBIT)
INH(INHIBIT)
INH(INHIBIT)
0
0
0
0
0
0
Up
Display
Down
Up
Display
Down
Up
Display
Down
OUT2(OUT)
OUT2(OUT)
OUT2
OUT1
Power Reset: There is no memory protection.(Initializes the display value when power is off)
Power Hold: There is memory protection.(Memorizes the display value at the moment of power off, indicates the memorized
display value when power is resupplied.)
Retained output
Retained outputOne-shot output One-shot output
T:Setting time
POWER
T T
INA
OUT2
(OUT)
T:Setting time
POWER
T
INA
OUT2
(OUT)
T1
t1
t2
T2
INA
OUT1
OUT2
T1: Setting time1
T2: Setting time2
t1: One-shot1
t2: One-shot2
(Single preset model has no INT.2 mode)
J-27
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
Output mode Input mode Operation
OFD
(OFD)
Signal Off Delay1(Power Reset)
1) If INA is ON, control output remains
ON. (except when power is off and
reset is on)
2) When INA signal is OFF, time pro-
cesses.
3) When it reaches setting time, indi-
cation value and control output are
reset automatically.
NFD
(NFD)
On-Off Delay (Power Reset) 1) When INA input is ON, output is
ON and time is progressing, then
output is OFF after On_Delay time.
2) When INA input is OFF, output is
ON and time is progressing, then
output is OFF after Off_Delay time.
3) If INA input is OFF within On_Delay
time, step 2 starts again.
4) If INA input is ON within Off_Delay
time, step 1 starts again.
NFd1
(NFD.1)
On-Off Delay1 (Power Hold) 1) When INA input turns ON, time
progresses and output turns ON
after On_Delay time.
2) When INA input turns OFF, time
progresses and output turns OFF
after Off_Delay time.
3) If INA input turns OFF within On_
Delay time, output will turn ON and
step2 operate.
4) If INA input turns ON within Off_
Delay time, output will turn OFF
and step1 operate.
INTG
(INTG)
Integration Time(Power Reset)
1) Time is progressing while INA input
is ON.
2) Time progress stops while INA input is
OFF.
3) When it reaches the setting time,
output is ON.
Power Reset: There is no memory protection.(Initializes the display value and the output status when re-supplying the power.)
Power Hold: There is memory protection.(It memorizes the status of power off. When re-supplying the power, it returns
the memorized display value and the output status.)
RESET
RESET
RESET
RESET
Setting time
Setting time
Setting time
On_Delay
On_Delay
On_Delay
On_Delay
Off_Delay
Off_Delay
Off_Delay
Off_Delay
Setting time
POWER
POWER
POWER
POWER
INA(START)
INA(START)
INA(START)
INA(START)
INH(INHIBIT)
INH(INHIBIT)
INH(INHIBIT)
INH(INHIBIT)
0
0
0
0
0
0
0
0
Up
Display
Down
Up
Display
Down
Up
Display
Down
Up
Display
Down
Up
Display
Down
OUT2(OUT)
OUT2(OUT)
OUT2(OUT)
OUT2(OUT)
Output operation mode(Timer)
POWER
INA
OUT2
(OUT) T: Setting time
T
INA
OUT2
(OUT) T1: On_Delay
T2: Off_Delay
T1 T2
INA
OUT2
(OUT) T1: On_Delay
T2: Off_Delay
T1 T2
Retained output
Retained outputOne-shot output One-shot output
J-28
CT Series
TOTAL
(TOTAL)
1) Time starts when INA input is ON.
2) Setting value is initialized when Reset input
is ON.
3) Time progress stops when INHIBIT input is
ON.
4) Resets when power is OFF.
1) Time starts when INA input is ON.
2) Setting value is initialized when Reset input
is ON.
3) Time progress stops while INHIBIT input
is ON.
4) Display value at the moment of power OFF
is memorized.
HOLD
(HOLD)
1) Time progresses when INA input is ON.
2) Time progress stops while INA input is OFF.
3) When time reaches setting time, display
value will stop and ash.
4) When reset input is applied, display value
is initialized.
5) Resets when power is OFF.
1) Time progresses when INA input is ON.
2) Time progress stops while INA input is OFF.
3) When time reaches setting time, display
value will stop and ash.
4) When reset input is applied, display value
is initialized.
5) Display value the moment when power is
OFF is memorized.
ONtD
(On Time
Display)
ON time indicate mode of INA input
1) Time reset start operates when INA input
turns ON.
2) Time progress stops while INA input is OFF.
3) When time progress stops and power is
off, the display value is initialized.
4) If progress time is greater than setting
time when INA input turns off, display
value ashes and operation stops until
reset signal is applied.
ON time indicate mode of INA input
1) Time reset start operates when INA input
turns ON.
2) Time progress stops while INA input is OFF.
3) When time progress stops and power is
off, the display value is memorized.
4) If progress time is greater than setting
time when INA input turns off, display
value ashes and operation stops until
reset signal is applied.
When memory protection setting is OFF
When memory protection setting is OFF
When memory protection setting is OFF
When memory protection setting is ON
When memory protection setting is ON
When memory protection setting is ON
RESET
Max.
time range
Max.
time range
POWER
INA(START)
INH(INHIBIT)
0
0
Up
Display
Down
RESET
RESET
RESET
RESET
Setting time
Setting time
Setting time
Setting time
Setting time
Setting time
Setting time
Setting time
POWER
POWER
POWER
POWER
INA(START)
INA(START)
INA(START)
INA(START)
INH(INHIBIT)
INH(INHIBIT)
INH(INHIBIT)
INH(INHIBIT)
0
0
0
0
0
0
0
0
Up
Up
Up
Up
Display
Display
Display
Display
Down
Down
Down
Down
RESET
Max.
time range
Max.
time range
POWER
INA(START)
INH(INHIBIT)
0
0
Up
Display
Down
Timer operation of the indicator(CT6S-I, CT6Y-I, CT6M-I)
J-29
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
Timer '0' time setting
Available output operation mode to set '0' time setting
OND, ONd1, ONd2, NFD, NFd1
Operation according to output mode(at 0 time setting)
Setting value1(PS1) is higher than Setting value2(PS2)
1) OND(Signal ON Delay) mode [OND]
2) OND.1(Signal ON Delay 1) mode [ONd1]
3) OND.2(Power ON Delay2) mode [ONd2]
4) NFD(ON-OFF Delay) mode [NFD]
5) NFD.1(ON-OFF Delay1) mode [NFd1]
● Setting time1 is set to 0
● Setting time1 is set to 0
● Setting time1 is set to 0
● OFF_Delay setting time is set to 0
● OFF_Delay setting time is set to 0
● Setting time2 is set to 0
● Setting time2 is set to 0
● Setting time2 is set to 0
● ON_Delay setting time is set to 0
● ON_Delay setting time is set to 0
OND(OND), OND.1(ONd1)or OND.2(ONd2)output mode
● UP mode: When the timer setting value1 is greater than the setting value 2, OUT1 output does not turn ON.
● DOWN mode: When the timer setting value1 is greater than the setting value 2, OUT1 output does not turn ON.
If the setting value 1 is same as the setting value2 and START signal is applied, OUT1 output turns ON
immediately.
Setting time2
OUT1
OUT2
INA(START)
0
UP mode DOWN mode
RESET
Setting time2
OUT1
OUT2
INA(START)
0
UP mode DOWN mode
RESET
Setting time1
OUT1
OUT2
INA(START)
0
RESET
Setting time1
OUT1
OUT2
POWER
0
UP mode
RESET
On_Delay
0
On_Delay
OUT2
(OUT)
INA(START)
0
Up
Display
Down
RESET
Off_Delay
0
Off_Delay
OUT2
(OUT)
INA(START)
0
Up
Display
Down
RESET
On_Delay
0
On_Delay
OUT2
(OUT)
INA(START)
0
Up
Display
Down
RESET
Off_Delay
0
Off_Delay
OUT2
(OUT)
INA(START)
0
Up
Display
Down
RESET
OUT1
OUT2
POWER
0
UP mode DOWN mode
Setting time 1
OUT1
OUT2
INA(START)
0
Setting time 2
J-30
CT Series
Communication mode
Parameter setting
Application of system organization
Communication control ordering
( key: To select setting mode, or key: To change setting value)
Address code
Address code
CT Series
Upper system
A → Min. 1sec. after applying power
B → 38400bps: Approx. 1ms.
19200bps: Approx. 2ms.
9600bps: Approx. 4ms.
4800bps: Approx. 8ms.
2400bps: Approx. 16ms.
C → Min. 20ms
A CB
Address code
Command
Command
Command
Data
Data
Data
CRC16
CRC16
CRC16
1. The communication method is Modbus RTU(PI-MBUS-300-REV.J).
2. After 1sec. of power supply into the high order system, it starts to communicate.
3. Initial communication will be started by the high order system. When a command comes out from the high order system,
CT Series will respond.
It is recommended to use communication converter, RS485 to Serial converter(SCM-38I, sold separately), USB to
RS485 converter(SCM-US48I, sold separately). Please use a proper twist pair for RS485 communication.
Computer
GND
V(12-24VDC)
RS232C Cable
RxD - RxD
TxD - TxD
GND - GND
Terminating
resistance
RS232C
B(-)
B(-)
A(+)
A(+) B(-) A(+) B(-) A(+) B(-)
B(1)
A(+)
CT Series
#01
CT Series
#02
CT Series
#30
CT Series
#31
ON
OFF
A(+)
RS485
Setting mode How to set
Com. address
(ADDR)
: To shift ashing digits of Com. address.
: To change the ashing digits.
Com. speed
(BPS)24 48 96 192 384
Com. parity
(PRTY)
NONE EVEN ODD
Com. stop bit
(STP)1 2
esponse
waiting time
(RSwT)
Com. write
(COmW)
ENA DISA
Setting range according to com. speed.
2400bps 16ms to 99ms
4800bps 8ms to 99ms
9600bps 5ms to 99ms
19200bps 5ms to 99ms
38400bps 5ms to 99ms
Setting range of com. address: 1 to 127
If the same address is applied during multicom.,
it will not work correctly.
ENA : Permits com. write(Enable)
DISA : Prohibits com. write(Disable)
2400/4800/9600/19200/38400bps
NONE: None EVEN : Even number ODD: Odd number
: To shift ashing digits position of com.
response waiting time.
: To change the ashing digits position
value.
J-31
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
Communication command and block
1) Read Coil Status(Func 01 H),
Read Input Status(Func 02 H
2) Read Holding Registers(Func 03 H),
Read Input Registers(Func 04 H)
3) Force Single Coil(Func 05 H)
4) Preset Single Register(Func 06 H)
The format of query and response
Read Coil Status(Func 01 H)
Master reads OUT2 00002(0001H) to 00003(0002H),
OUT1 output status(ON : 1, OFF : 0) from the
Slave(Address 01).
On slave side OUT2 00003(0002H) : OFF,
OUT1 00002(0001H) : ON
Read Input Register (Func 04 H)Master reads preset value
21004(03EBH) to 21005(03ECH) of counter/timer, Slave
(Address 15).
In case that the present value is 123456(0001 E240 H) in
slave side, 31004(03EBH): E240 H, 31005(03ECH): 0001H
● Query(Master)
● Query(Master)
● Query(Master)
● Query(Master)
● Response(Slave)
● Response(Slave)
● Response(Slave)
● Response(Slave)
CRC 16
CRC 16
CRC 16
CRC 16
CRC 16
CRC 16
CRC 16
CRC 16
Slave
Address
Function
Starting
Address No. of Points Error Check
(CRC 16)
High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address
Function
Starting
Address No. of Points Error Check
(CRC 16)
High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address
Function
Coil Address Force Data
Error Check
(CRC 16)
High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address
Function
Register
Address Preset Data
Error Check
(CRC 16)
High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address
Function
Coil Address Force Data
Error Check
(CRC 16)
High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address
Function
Register
Address Preset Data
Error Check
(CRC 16)
High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address
Function
Byte
Count Data Data Data
Error Check
(CRC 16)
Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address
Function
Byte
Count
Data Data Data Error Check
(CRC 16)
High Low High Low High Low Low High
1Byte 1Byte 1Byte
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
5) Preset Multiple Registers(Func 10 H)
6) Application
● Query(Master)
● Query(Master)
● Query(Master)
● Response(Slave)
● Response(Slave)
● Response(Slave)
Slave
Address Function
Starting
Address
No. of
Register
Byte
Count
Data Data
Error
Check
(CRC 16)
High Low High Low High Low High Low Low High
1Byte 1Byte
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address Function
Starting Address No. of Register Error Check
(CRC 16)
High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
Slave
Address Function
Byte
Count
Data Data Error Check
(CRC 16)
High Low High Low Low High
0F H 04 H 04 H E2 H 40 H 00 H 01 H E2 H 28 H
Slave
Address Function Starting Address No. of Points Error Check
(CRC 16)
High Low High Low Low High
0F H 04 H 03 H EB H 00 H 02 H 00 H 95 H
Slave
Address Function Starting Address No. of Points Error Check
(CRC 16)
High Low High Low Low High
01 H 01 H 00 H 01 H 00 H 02 H EC H 0B H
Slave
Address Function Byte Count
Data
(00003 to
00001)
Error Check
(CRC 16)
Low High
01 H 01 H 01 H 02 H D0 H 49 H
CRC 16
CRC 16
J-32
CT Series
Modbus Mapping Table
1) Reset/Output
2) Terminal input status
3) Product Information
4) Monitoring data
5) Preset value setting group
● Date format of 31001(03E8) address bit
No(Address) Func Explanation
Setting range
Notice
00001(0000)
01/05
Reset
0:OFF 1:ON
00002(0001)
01
OUT2 output
0:OFF 1:ON
00003(0002)
01
OUT1 output
0:OFF 1:ON
00004(0003)
01 BATCH output
0:OFF 1:ON
For BATCH
output model
00005(0004)
01/05 BATCH resets
0:OFF 1:ON
For BATCH
output model
No(Address) Func
Explanation Setting range Notice
31001
(03E8) 04
BA.O LED
display status
0:OFF 1:ON Bit 5
OUT2 LED
display status
0:OFF 1:ON Bit 6
OUT1 LED
display status
0:OFF 1:ON Bit 7
BA.S LED
display status
0:OFF 1:ON Bit 10
LOCK LED
display status
0:OFF 1:ON Bit 11
PS2 LED
display status
0:OFF 1:ON Bit 12
PS1 LED
display status
0:OFF 1:ON Bit 13
TMR LED
display status
0:OFF 1:ON Bit 14
CNT LED
display status
0:OFF 1:ON Bit 15
31002(03E9)
04
Present value
of BATCH
counter
0 to 999999
For BATCH
output
model
31003(03EA)
31004(03EB)
04
Present value
of
counter/timer
Counter
6digit type: -99999 to
999999
4digit type: -999 to 9999
Timer: Within time setting
range
Use counter
and timer
in common
31005(03EC)
31006(03ED)
04
Display unit
Counter: decimal point
of display value
Timer: Time range
Counter:
40058 Data
Timer:
40102 Data
31007(03EE)
04
PS(2)
setting value
Counter
6digit type: -99999 to
999999
4digit type: -999 to 9999
Timer: Within time setting
range
Use counter
and timer
in common
31008(03EF)
31009(03F0)
04
PS1
setting value
Counter
6digit type: -99999 to
999999
4digit type: -999 to 9999
Timer: Within time setting
range
Use counter
and timer
in common
31010(03F1)
31011(03F2)
04
Setting value
of BATCH
counter
0 to 999999
Use counter
and timer
in common
31012(03F3)
31013(03F4)
04
Checking the
input logic 0: NPN, 1 : PNP
No(Address)
Func Explanation
Setting range
Notice
10001(0000) 02 INA input status 0:OFF 1:ON
Terminal input
status
10002(0001) 02 INB input status 0:OFF 1:ON
Terminal input
status
10003(0002) 02 INHIBIT input status 0:OFF 1:ON
Terminal input
status
10004(0003) 02 RESET input status 0:OFF 1:ON
Terminal input
status
10005(0004) 02
BATCH RESET
input status
0:OFF 1:ON
Terminal input
status
No(Address)
Func Explanation Setting range Notice
40001(0000)
03
06
16
PS2 setting value
PS setting value
Counter
6digit type: 0 to
999999
4digit type: 0 to 9999
Timer: Within time
setting range
Use counter
and timer
in common
40002(0001)
40003(0002)
03
06
16
PS1 setting
value
Use counter
and timer
in common
40004(0002)
40005(0004)
03
06
16
BATCH coun-
ter
setting value
0 to 999999
Use counter
and timer
in common
40006(0005)
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit4 Bit 3 Bit 2 Bit 1 Bit 0
CNT TMR PS1 PS2
LOCK
BA.S
- -
OUT1 OUT2
BA.O
-----
0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 0 0 or 1 0 or 1 0 or 1 0 0 0 0 0
No(Address)
Func
Explanation Notice
30001~30100
04 Reserved
-
30101(0064)
04 Product number H Model ID
30102(0065)
04 Product number L
30103(0066)
04 Hardware version
-
30104(0067)
04 Software version
-
30105(0068)
04 Model no. 1 "CT"
30106(0069)
04 Model no. 2 "6M"
30107(006A)
04 Model no. 3 "-2"
30108(006B)
04 Model no. 4 "PT"
30109(006C)
04 Reserved
-
30110(006D)
04 Reserved
-
30111(006E) 04 Reserved
-
30112(006F) 04 Reserved
-
30113(0070) 04 Reserved
-
30114(0071) 04 Reserved
-
30115(0072) 04 Reserved
-
30116(0073) 04 Reserved
-
30117(0074) 04 Reserved
-
30118(0075) 04 Coil Status
Start Address 0000
30119(0076) 04 Coil Status
Quantity
-
30120(0077)
04 Input Status
Start Address 0000
30121(0078)
04 Input Status Quantity
-
30122(0079)
04 Holding Register
Start Address 0000
30123(007A)
04 Holding Register
Quantity
-
30124(007B)
04 Input Register
Start Address 0064
30125(007C)
04 Input Register Quantity
-
2 Words data format: Upper data has high number address.
Ex)31004 : Present Value(Low Word),
31005 : Present Value(High Word)
J-33
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
6) Function setting mode (Counter group)
7) Function setting mode (Timer group)
No(Address) Func Explanation Setting range Notice
40051(0032) 03/06/16 Counter/Timer
(C-T)
1:
COUN
1:
TIME
Use counter and timer in common
40052(0033) 03/06/16 Input mode(IN)
0:
UP
1:
UP-1
2: UP-2
3:
DN
4:
DN-1
5:
DN-2
6:
UD-A
7:
UD-B
8:
UD-C
-
40053(0034) 03/06/16 Indication mode(DISM)0:
TOTAL
1:
HOLD
For the indicator
40054(0035) 03/06/16 Output mode(OUTM)
0:
F
1:
N
2:
C
3:
R
4:
K
5:
P
6:
Q
7:
A
8:
S
9:
T
10:
D
-
40055(0036) 03/06/16 Maximum counting
speed(CPS)
0:
1
1:
30
2:
1K
3:
5K
4:
10K
-
40056(0037) 03/06/16 OUT2(OUT) output time
0001
~
9999
unit: ×10
40057(0038) 03/06/16 OUT1 Output time
0001
~
9999
unit: ×10
40058(0039) 03/06/16 Decimal point(DP)0:
------
2:
----.--
4:
--.----
1:
-----.-
3:
---.---
5:
-.-----
4digit type 0: ----
1: ---.- 2: --.-- 3: -.---
40059(003A) 03/06/16 Min. reset time
(RST)
0:
1
1:
20
unit: ms
40060(003B) 03/06/16 Prescale decimal
point position(SClD)
0:
-----.-
3:
---.---
5:
-.-----
2:
----.--
4:
--.----
4digit type
1: ---.- 2: --.-- 3: -.---
40061(003C) 03/06/16 Prescale value(SCL)6digit type:
)00001
to
999999
4digit type:
)001
to
9999
Connected with prescale
decimal point position
40062(003D)
40063(003E) 03/06/16 Start value(STRT)6digit type:
000000
to
999999
4digit type:
0000
to
9999
Connected with decimal
point position of display value
40064(003F)
40065(0040) 03/06/16
Memory protection
(DATA)0: CLR 1: REC Use counter and timer
in common
40066(0041) 03/06/16 Lock key(LOCK)0: lOFF 1: LOc1 2: LOc2 3: LOc3
No(Address) Func Explanation Setting range Notice
40101(0064) 03/06/16 Counter/Timer
(C-T)
0:
COUN
1:
TIME
Use counter and timer
in common
40102(0065) 03/06/16 Time range
(
HOUR
/
MIN
/
SEC
)
4digit type
-
0: 0.001s to 9.999s
1: 0.01s to 99.99s
2: 0.1s to 999.9s
3: 1s to 9999s
4: 1s to 99m59s
5: 0.1m to 999.9m
6: 1m to 9999m
7: 1m to 99h59m
8: 1h to 9999h
6digit type
0: 0.001s to 999.999s
1: 0.01s to 9999.99s
2: 0.1s to 99999.9s
3: 1s to 999999s
4: 0.01s to 99m59.99s
5: 0.1s to 999m59.9s
6: 1s to 9999m59s
7: 1m to 99999.9m
8: 1m to 999999m
9: 1s to 99h59m59s
10: 1m to 9999h59m
11: 0.1h to 99999.9h
40103(0066) 03/06/16 UP/Down mode
(
U-D
)0:
UP
1:
DN
-
40104(0067) 03/06/16 Output mode
(
OUTM
)
0:
OND
1:
ONd1
2:
ONd2
3:
FLK
4:
FLk1
5:
FLk2
7:
INt1
8:
INt2
9:
OFD
10:
NFD
11:
NFd1
12:
INtG
-
40105(0068) 03/06/16
OUT2(OUT) Output time
(
OUT2
)
0000
to
9999
(0: Hold) unit: ×10ms
40106(0069) 03/06/16 OUT1 Output time
(
OUT1
)
0000
to
9999
(0 : Hold) unit: ×10,ms
40107(006A) 03/06/16 Input signal time(
INT
)0:
1
1:
20
unit: ms
40108(006B) 03/06/16
Memory protection
(
DATA
)0:
CLR
1:
REC
Use counter and timer in common
40109(006C) 03/06/16 Lock key(
LOCK
)0:
lOFF
1:
LOc1
2:
LOc2
3:
LOc3
Use counter and timer in common
40110(006D) 03/06/16 ndication mode(
DSpM
)0:
TOTAL
1:
HOLD
2:
ONtD
For the indicator
J-34
CT Series
8) Function setting mode (Communication group)
Exception processing
Read of the parameter area
00002(OUT2), 00003(OUT1), 00004(BA, 0), 10001 to 10005(Terminal input), 30101 to 30125(Product information),
31001 to 31013(Monitoring data)
Read and write of the parameter area
00001(Reset starts), 00005(BATCH Reset starts), 40001 to 40006(Setting value saving group),
40051 to 40066(Counter setting group), 40101 to 40110(Timer setting group),
40151 to 40156(Communication setting group)
Read of communication
Read parameter value using communication.(Function : 01H, 02H, 03H, 04H)
It is able to read communication regardless of permitting/prohibiting communication writing.
Communication write
Change parameter value using communication.(Function: 05H, 06H, 10H)
● When change the parameter setting value of ' Function setting mode Counter group' or ' Function setting mode
Timer group' using communication, reset indication will ash in 3 sec. and display value will be reset.(Counting display
value and progress time before changing parameter setting value are not saved.)
● When change the parameter setting value of ' Preset value setting group' or ' Function setting mode Communica-
tion group' using communication, counting display value or progress time will not be reset.
● In prohibit writing communication setting ( = 1: ), a write command does not process.
● If set value beyond the setting range, this setting value is substituted for the value within the setting range and then
memorized.
When communication error occurs, the highest bit of received function is set
to 1, then sends response command and transmits exception code.
● Illeegal Function(Exception Code: 01H): Not supporting command
● Illegal Data Address(Exception Code: 02H): Mismatch between the number of asked data and the number of transmit-
table data.
● Illegal Data Value(Exception Code: 03H): Mismatch between asked the number of data and transmittable the number of
data in device
● Slave Device Failure(Exception Code: 04H): Command is processed incorrectly.
Example)
Master reads output status (ON:1, OFF:0) of non existing coil 01001 (03E8 H) from Slave (Address17).
No(Address) Func Explanation Setting range Notice
40151(0096) 03/06/16 Com. address (
ADDR
) 1 to 127
-
40152(0097) 03/06/16 Com. speed (
BPS
) 0:
24
1:
48
2:
96
3:
192
4:
384
unit: ×100bps
40153(0098) 03/06/16 Com. parity (
PRTY
) 0:
NONE
1:
EVEN
2:
ODD
-
40154(0099) 03/06/16 Stop bit (
STP
) 0:
1
1:
2
-
40155(009A) 03/06/16
Response waiting time (
RSwT
)
05 to 99 unit: ms
40156(009B) 03/06/16 Com. writing (
COmW
) 0:
ENA
1:
DISA
-
Slave Address Function+80H Exception Code Error Check(CRC16)
Low High
1Byte 1Byte 1Byte 1Byte 1Byte
Slave Address Function Starting Address No. of Points Error Check(CRC16)
High Low High Low Low High
11H 01H 03H E8H 00H 01H ##H ##H
Slave Address Function + 80H Exception Code Error Check(CRC16)
Low High
11H 81H 02H ##H ##H
Read and write of parameter value using communication
● Response(Slave)
● Query(Master)
J-35
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Programmable Counter/Timer
Input signal line
● Use as short a cable from the sensor to this unit as possible.
● Use shielded cable for long input line.
● Wire as separating input line from the power line.
When selecting input logic
Be sure that supply power is off when selecting input logic,
then select logic input according to input logic changing
method.
Contact count input (When it is used as Counter)
If apply contact input at high speed mode(1k, 5k, 10k), it
may cause miscount by chattering.
Therefore set low speed mode(1cps or 30cps) at contact input.
When test dielectric voltage and insula-
tion
resistance of the control panel with this
unit
installed.
● Please isolate this unit from the circuit of control panel.
● Please make all terminals of this unit short-circuited.
Do not use below places.
● Place where there are severe vibration or impact.
● Place where strong alkalis or acids are used.
● Place where there are direct ray of the sun.
● Place where strong magnetic eld or electric noise are
generated.
Installation environment
● It shall be used indoor.
Altitude Max. 2000m
● Pollution Degree 2
● Installation Category II
Proper usage
Power ON
OFF 100500
The unstable time
against the input signal.
The power ON/OFF
Power voltage rises for 100ms after power on and falls for
500ms after power off. Therefore be sure to apply input
signal after 100ms and power turns on again after 500ms
when power turns off.
● Be sure to use insulated and resistive voltage /current
or
Class2 supply power device to input 24VAC/24-48VDC
power supply model.