Manual actuated valves www.crouzet.com 11 Push buttons diameter 12 and actuators Features Version NC N0 Actuator color black red black/red black red black/red Valve color black black black grey grey grey Push button round 81 735 511 81 735 512 81 735 011 - Push button double round 81 733 511 - 28 2.7 200 28 2.7 200 Symbol NC 1 NO Characteristics Operating pressure Orifice diameter Flow at 6 bars NC : black NO : grey Operating forces (depending on actuator) Effective travel Fluid: dry or lubricated air Push-in connectors for semi-rigid tubing (NFE 49100) Operating temperature Mechanical life Weight bar mm Nl/mn. Valves 8 18 1 N mm 8 18 1 mm O4 O4 C operations g -5 +50 1.5 x 106 35 -5 +50 1.5 x 106 40 Dimensions 81 735 Threaded barrel 12 81 733 2 threaded barrels www.crouzet.com 3-position lever manual return 81 716 511 81 716 512 - 3-position lever spring return 81 715 511 81 715 512 - Horizontal outputs Vertical outputs 81 280 510 81 280 010 - 81 281 510 81 281 010 - 1 28 2.7 200 28 2.7 200 28 2.7 200 8 18 1 8 18 1 28 2.7 200 - 1 1 - - O4 O4 O4 O4 -5 +50 1.5 x 106 65 -5 +50 1.5 x 106 65 -5 +50 1.5 x 106 14 -5 +50 1.5 x 106 14 81 715 - 81 716 81 280 010 - 81 280 510 Square lever 81 281 010 - 81 281 510 28,5 M3 www.crouzet.com 13 3/2 valves for manual actuators O 22 mm Connection O4 3/2 valve supplied with screws Gas 1/8 for fixing the adaptator Connection O4 Valve(s) 3/2 fixed on adaptator (supplied with adaptator not assembled) Adaptator for 3/2 valve on actuators O 22 Version 89 543 501 89 543 701 89 543 101 89 543 201 - - - - - - 89 543 105 89 543 005 89 543 305 89 543 205 - - - - NC + NC 08 2 112 12.6 -5 +60 1.5 x 106 NC NO NC NO NC + NO bar mm NI/min N C operations 08 2 112 12.6 -5 +60 1.5 x 106 08 2 112 12.6 -5 +60 1.5 x 106 08 2 112 12.6 -5 +60 1.5 x 106 08 2 112 12.6 -5 +60 1.5 x 106 08 2 112 12.6 -5 +60 1.5 x 106 g 50 24 679 702 Symbol Characteristics 50 60 Principle of operation Dimensions NC version 89 543 001 - 89 543 201 60 110 - 110 40 O 22 series 89 543 501 - 89 543 701 Exhaust 1 2 Supply Output Holes drilled in panel for actuators O 22 Installation EN 50007 46,5 1 Operating pressure Orifice diameter Flow at 6 bars Control force Operating temperature in dry air Life Non-connectable exhaust Weight 32 Holes drilled for the (optional) use of a round lug. * > 40 O 40 push-buttons * > 45 for lever type rotary switches 14 www.crouzet.com Actuators O 22 mm for manually operated valves Push buttons Red Green Black 2-positions rotary switches 3-positions rotary switches Function 24 678 129 24 678 128 24 678 127 Flush push contact 24 678 173 24 678 172 Emergency stop plastic O 40 24 678 171 Emergency stop O 40 mm pushturn 24 678 174 Black symmetrical actuator 24 678 175 Long lever Black Symbol Position 45 Weight g 30 45 45 45 45 24 678 127 - 24 678 128 24 678 171 - 24 678 172 24 678 129 24 678 173 O 29 O 40 2-positions rotary switches 3-positions rotary switches Function 24 678 180 RONIS key 455 removable in position 0 24 678 176 Black symmetrical actuator 24 678 178 Black symmetrical actuator with return 1 34,5 13,5 Dimensions 45 24 678 177 Long lever Black 24 678 179 Black Long lever, spring to center 24 678 182 RONIS key 455 remov. in pos. 0 3 positions with spring to center 24 678 181 RONIS key 455 removable in position 0 3 fixed positions Symbol Position Weight Dimensions 45 2 x 45 2 x 45 2 x 45 2 x 45 2 x 45 2 x 90 70 45 45 16 45 70 70 24 678 174 - 24 678 176 24 678 175 - 24 678 177 24 678 180 - 24 678 181 24 678 178 24 678 179 24 678 182 O 30 38,3 O 29 29 27 23 27 27,3 www.crouzet.com 15 the rms to tive o f n o C irec nery D i h c a M Definition (conforming to EN 574 +A1) A pneumatic 2-hand control device is used with dangerous machinery and requires the simultaneous use of both hands to trigger and maintain machine operation. Such a device must be located outside the dangerous zone, so that the operator cannot enter this zone before the machine has come to a complete standstill. A pneumatic 2-hand control device is composed of 2 parts : 2 manual pushbuttons which require the simultaneous use of both hands. A pneumatic relay. 1 Types of 2-hand control devices Type Requirements I III II A B C Use of both hands (simultaneous actuation) Relationship between input signals and output signal Cessation of the output signal Prevention of accidental operation Prevention of defeat Reinitiation of the output signal Synchronous actuation Use of category 1 (EN 954-1) Use of category 3 (EN 954-1) Use of category 4 (EN 954-1) Category 1 (EN ISO 13849) : the system should use well tried components and principles. Category 3 (EN ISO 13849) : the system must be designed so that a single fault will not cause the loss of the safety function. Category 4 (EN ISO 13849): the system must be designed so that an accumulation of faults must not lead to a loss of the safety function. Synchronous action An output signal is only generated if both control actuating devices are actuated within 500 ms. Resetting the output signal The release of a single control device interrupts the output signal, but a reset is only possible once both control devices have been released. 16 www.crouzet.com Pneumatic relay for two-hand control 100% pneumatic Complies with Machinery Directive and the standard EN 574 +A1 CE Certification type-IIIA and IIIB 81 580 101 III A Pneumatic relay for two-hand control EN 574 +A1 classification 81 580 202 III B Symbol 1 3 1 2 Characteristics Operating pressure Orifice diameter Max. delay between input signals Connection Operating temperature Mechanical life Weight Principle of operation 28 2.5 0.2 max. Sub-base 81 532 001 -5 +50 C 107 operations 90 g Connections (Typical application with double-acting cylinder) 81 580 101 81 580 101 28 2.5 0.2 max. Semi-rigid tubing O 4 (NFE 49100) -5 +50 107 320 bar mm s 1 81 580 202 1 81 580 101 81 580 202 Components follow current standards To obtain an output signal it is necessary to give simultaneous input signals 'a' and 'b' with a max. delay of 0.45. The output signal 's' is lost if one or both of the inputs are removed. Dimensions 81 580 202 34,5 64 125,7 10,5 15 25 76 23 32 81 580 101 Sb Sa Pb Pa Sb Sb Pb Pb Mounted on sub-base 81 532 001 (See page 55 of Pneumatic catalogue) 32 M4 21,25 24 www.crouzet.com 2 x M4 Depth 10 17 Two-hand pneumatic safety start module Conforms to the Machinery Directive and standard EN 574 Including pneumatic relay to classification IIIA or IIIB depending on version Two-hand pneumatic safety start module Pneumatic relay (to EN 574) 81 580 504 Type III A 81 580 503 Type III B S S P P Symbol Characteristics 1 Operating pressure bar Orifice diameter mm Max. delay between input signals s Connection Operating temperature C Mechanical life operations Weight g Connections (Typical application with double-acting cylinder) 81 580 504 P 28 2.5 0.2 max. Semi-rigid tubing O 4 (NFE 49100) -5 +50 1.5 x 106 1000 S 28 2.5 0.2 max. Semi-rigid tubing O 4 (NFE 49100) -5 +50 1.5 x 106 1410 81 580 503 P 1 81 580 504 S 81 580 503 Components follow current standards Dimensions 81 580 503 - 81 580 504 Supply via 4 mm push-in fitting Output via 4 mm push-in fitting Fixing viewed from below 18 www.crouzet.com Pneumatic impulse counters 4, 5, 6 digits with or without reset With or without pre-selection Totalizer Preselection counter Version 99 766 001 6 digits no reset to zero 99 766 002 4 digits with manual zero reset 89 538 201 5 digits with manual or pneumatic zero reset 28 > 0.3 > 1.4 28 > 0.3 > 1.4 0 +60 150 0 +60 150 28 > 0.15 > 0.8 2 150 28 Symbol 1 Characteristics Supply pressure Pressure to break Pressure to make Reset : Minimum pressure Reset time Circuit pressure bar Signal emitted when preset is reached Operating temperature Weight - bar bar bar bar ms C g 0 +60 136 A - Output signal P - Supply Y - 'Reset to zero' signal Z - Input signal Connection Note : the count pulse must be removed before the reset pulse is applied. The preset value can be changed during operation without the counter resetting to zero. Dimensions Connectors for semi-rigid tubing O 4 (NFE 49100) 99 766 002 14,5 22 x 33,3 48 5,3 89 538 201 O 3.2 f/90 24 = 2 holes for M3 screws = O 4 0000 = O 3,2 F/90 41,5 2 3 60,6 = 99 766 001 = O 4 0 00000 = O 3,2 F/90 41,5 www.crouzet.com = 24 = 23 = 48 = = 37 = M3 41,5 19 Indicators and pedal valves Ergonomics Also available in ATEX version for use in potentially explosive atmospheres in accordance with 94/9/EC Directive Pneumatic indicators O 22 84 84 84 84 Red Green Yellow Blue 150 150 150 150 Pedal valve - Version NC 201 202 203 204 - 81 999 501 Symbol 1 Characteristics Operating pressure Push-in connection for semi-rigid tubing (NFE 49100) Operating temperature Mechanical life Weight Dimensions bar 28 mm O4 O4 - C operations g -5 +50 107 34 -5 +50 1.5 x 106 290 84 150 201 - 84 150 202 84 150 203 - 84 150 204 81 999 501 White tube Input Output Red tube Holes drilled for indicators ATEX version products are available in the following catologues: Pneumatic products for explosive atmospheres or on our website www.crouzet.com 20 www.crouzet.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 81715512 89543501 89543101 89543701 89543201 89543305 89543205 89538201 89543005