Key Features
Pressure ranges from 25mbar to 10bar
Logging and leak testing – ideal for
more accurate gas tightness test
Positive and negative (vacuum)
pressure measurement
Auto ranging displays – for precise
readings
Selectable auto switch‑off – saves on
operation cost and battery life
IP67 BSI Cert 229/000132 – Dust and
waterproof for added protection
Selectable pressure units: psi, mbar,
inH2O, mmH2O, mmHg, inHg, Pa
dig.20
Easy to operate, reliable and robust the 2000 Series Pressure
instruments surpass the performance and cost demands of today’s
industrial & HVAC markets.
Combining innovative functions with high accuracy and speed
of response they are designed to make the operator’s job simple and
efcient.
The 2000 Series offers twin input for differential or gauge
measurement with pressure ranges from 25mbar to 10bar. Advanced
features include auto leak detection and logging – logs can be viewed
on the meter or downloaded to a PC. All instruments are dust and
waterproof as standard (IP67) and optional coloured rubber boots are
available adding protection and style to these multifunctional pressure
instruments.
Pressure Instruments
2000 Series
Digitron
info@digitron.co.uk
www.digitron.co.uk
Woodland Road
Torquay, Devon
TQ2 7AY
Tel: +44 (0)1803 407700
Applications
HVAC
Industrial
Laboratories
Clean Rooms
Service/Maintenance
Calibration
Air conditioning
Optional Extras
2000BT Protective Rubber Boot
6mm Nylon Tubing
6mm Nylon ‘T’ Piece
Carry Case
Calibration Certicate
Digilink Logging Interface
Software
Pressure Pump Max 5bar
Vacuum Pump Max ‑750mbar
2020P
Pressure Instruments 2000 Series
dig.20
Digitron
info@digitron.co.uk
www.digitron.co.uk
Woodland Road
Torquay, Devon
TQ2 7AY
Tel: +44 (0)1803 407700
Specification
Operating Temperature 0°C to +50°C/+14°F to +122°F (ambient)
Battery Type Two AA or equivalent cells (not supplied)
Battery Life Typically 200 hours
Low Battery Check Symbol appears on display
Display 12.7mm / 0.5” custom L.C.D.
Over range/Under range ‘Out’ displayed
Environmental Specications IP67 as standard with hose connected
Auto Switch‑Off Time 12 minutes
Dimensions 155 x 67 x 40mm/6.1 x 2.6 x 1.6”
Weight 180g/6.4oz
Instrument accuracies 0.15%rdg +0.15%fs + 1 digit.
From ‑10°C to +50°C/+14°F to +122°F 0.3%rdg +0.3%fs to +1 digit (‑Ve Pressures)
Model Options 2020P 2021P 2022P 2023P 2024P 2025P 2026P 2027P 2028P 2082P 2083P 2084P 2085P 2086P
Operating Range 25mbar 30mbar 2bar 7bar † External 2bar 0 to 10bar 500mbar 1 bar 2bar 7bar † External 2bar 0 to 10bar
transducer Absolute transducer
Over range 350mbar 750mbar 4bar 10bar 4bar 21bar 1ba 2 bar 4bar 10bar 4bar 21bar
Absolute Absolute
Backlight • • • • • • • • • • • • • •
Outofrange • • • • • • • • • • • • • •
Zeroing • • • • •  • • • • • •  •
Hold • • • • • • • • • • • • • •
Smoothing • • • • • • • • • • • • • •
UnitsofPressure • • • • • • • • • • • • • •
RangeLock • • • • • • • • • • • • • •
Max/Min • • • • • • • • • • • • • •
ZeroingAbsolute      •       •
Averaging          • • • • •
LeakTesting          • • • • •
Logging          • • • • •
Pressure Instruments 2000 Series
dig.20
Digitron
info@digitron.co.uk
www.digitron.co.uk
Woodland Road
Torquay, Devon
TQ2 7AY
Tel: +44 (0)1803 407700
Pressure Scales
20x0P 20x1P 20x2P 20x3P
mbar 0 to 1999 μbar ++0.00 to 25.00 mbar 0.00 to 19.99 mbar + 0.0 to 130.0 mbar 0.0 to 199.9 mbar + 0 to 1999 mbar 0 to 1999 mbar + 0.00 to 7.00 bar
Pa 0.0 to 199.9 Pa + 0 Pa to 2500 Pa 0.00 to 13.00 kPa 0.00 to 19.99 kPa + 0.0 to 199.9 kPa 0.0 to 199.9 kPa + 0 to 700 kPa
in H2O 0.00 to 10.05” 0.00 to 52.28” 0.0 to 199.9” + 0 to 804” 0.0 to 199.9” + 0 to 2815
m H2O 0.00 to 19.99 mm + 0.0 to 255.3 mm 0.0 to 199.9 mm + 0 to 1320 mm 0.00 to 20.43 m 0.00 to 19.99 m + 0.0 to 71.5 m
in Hg 0.00 to 0.73” 0.00 to 3.83” 0.00 to 59.00 0.00 to 19.99” + 0.0 to 206.7”
m Hg 0.00 to 18.75 mm 0.00 to 19.99 mm + 0.0 to 97.5 mm 0.00 to 19.99 cm + 0.0 to 150.0 cm 0.00 to 5.25 m
PSI 0.00 to 0.36 psi 0.00 to 1.88 psi 0.00 to 29.00 psi 0.00 to 19.99 psi + 0.0 to 101.5 psi
20x5P Absolute 20x6P 20x7P 20x8P
mbar 0.0 to 199.9 mbar + 0 to 1999 mbar 0 to 1999 mbar + 0.00 to 10.00 bar 0.0 to 199.9mbar + 0 to 500mbar 0.0 to 199.9mbar + 0 to 1000mbar
Pa 0.00 to 19.99 kPa + 0.0 to 199.9 kPa 0.0 to 199.9 kPa + 0 to 1000 kPa 0.00 to 19.99kPa + 0.0 to 50.0kPa 0.00 to 19.99kPa + 0.0 to 100.0kPa
in H2O 0.0 to 199.9” + 0 to 804” 0.0 to 199.9” + 0 to 4022 0.0 to 199.9” + 0 to 201” 0.0 to 199.9” + 0 to 402”
m H2O 0.00 to 20.43 m 0.00 to 19.99 m + 0.0 to 102.2 m 0.00 to 5.11m 0.00 to 10.22m
in Hg 0.00 to 59.00 0.00 to 19.99” + 0.0 to 295.3 0.00 to 14.75” 0.00 to 29.5”
m Hg 0.00 to 19.99 cm + 0.0 to 150.0 cm 0.00 to 7.50m 0.00 to 19.99cm + 0.0 to 37.5cm 0.00 to 19.99cm + 0.0 to 75.0cm
PSI 0.00 to 29.00 psi 0.00 to 19.99 psi + 0.0 to 145.0 psi 0.00 to 19.99 psi + 0.0 to 145.0 psi 0.00 to 14.50psi