Catalog KT 10.1 2004 Catalog KT 10.1 2004 SITOP Power supplies The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in terms of contract. Availability and technical specifications are subject to change without notice. sitop Siemens AG Automation and Drives Systems Engineering Sales Power Supplies, System Cables www.siemens.com Order No.: E86060-K2410-A101-A5-7600 Power supplies SITOP power LOGO!Power Related catalogs System Cabling SIMATIC TOP connect KT 10.2 PD 20 LV 10 ST 70 Products for Totally Integrated Automation and Micro Automation Order No.: E86060-K4670-A111-A9-7600 Industrial Communication IK PI Order No.: E86060-K6710-A101-B4-7600 SINUMERIK & SIMODRIVE A&D Mall Internet: www.siemens.com/automation/mall Order No.: E86060-K1002-A101-A4-7600 SIMATIC The offline Mall of Automation and Drives Order No.: CD: E86060-D4001-A110-C3-7600 Order No.: E86060-K2802-A101-A1 Low Voltage ITC Order No.: Paper: E86060-K6850-A101-B3 CD: E86060-D6850-A100-B7-7400 Order No.: E86060-K2410-A201-A3-7600 Stromversorgungen SITOP power, LOGO!Power, SIDAC-S 1) Training for Information and Industrial Solutions 1) NC 60 Automation Systems for Machine Tools Order No.: E86060-K4460-A101-B1-7600 PC-based Automation Order No.: E86060-K4670-B111-B2-7600 1) Available in German only. Trademarks All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. CA 01 SITOP Power supplies SITOP power LOGO!Power Introduction Overview of product families, Selection guide SITOP power, Standard 24 V Single-phase, Output currents up to 2 A Single-phase, Output currents 2.5 to 4 A Catalog KT 10.1 * 2004 Single-phase and two-phase, Output current 5 A Supersedes: Catalog KT 10.1 * 2002 Single-phase and two-phase, Output current 10 A The products contained in this catalog also appear in CD-ROM catalog CA 01 Order No.: E86060-D4001-A110-C3-7600 Single-phase and two-phase, Output currents 20 and 40 A Please contact your local Siemens representative. Three-phase, Output currents 5 to 40 A (c) Siemens AG 2004 Additional components Uninterruptible power supplies The products and systems described in this catalog are manufactured/distributed under application of a certified quality management system in accordance with DIN EN ISO 9001 (Certified Registration No. 1108). The certificate is recognized by all IQNet countries. SITOP power Alternative voltages SITOP power AS interface power supplies SITOP power Customized LOGO!Power Dimension drawings s 2 3 4 5 6 7 8 9 10 11 12 13 Technical information and configuration Appendix 1 Contact persons Indexes 14 15 16 Welcome to Automation and Drives We would like to welcome you to Automation and Drives and our comprehensive range of products, systems, solutions and services for production and process automation and building technology worldwide. With Totally Integrated Automation and Totally Integrated Power, we deliver solution platforms based on standards that offer you a considerable savings potential. Discover the world of our technology now. If you need more detailed information, please contact one of your regional Siemens partners. They will be glad to assist you. 1/2 Siemens KT10.1 * 2004 Siemens KT10.1 * 2004 1/3 Totally Integrated Automation innovations for more productivity With the launch of Totally Integrated Automation, we were the first ones on the market to consistently implement the trend from equipment to an integrated automation solution, and have continuously improved the system ever since. Whether your industry is process- and production-oriented or a hybrid, Totally Integrated Automation is a unique "common solution" platform that covers all the sectors. Totally Integrated Automation is an integrated platform for the entire production line - from receiving to technical processing ERP Enterprise Resource Planning MES Manufacturing Execution Systems Control SIMATIC NET Industrial Communication Ethernet Ethernet Production Order Management Material Management Production Operations Recording Equipment Management SINAUT Telecontrol System SIMATIC Software Industrial Ethernet SIMATIC Machine Vision Industrial Ethernet Industrial Wireless Communication/ MOBIC Safety Integrated PROCESS FIELD PROFIBUS PC-based Automation AS-Interface GAMMA instabus 1/4 Siemens KT10.1 * 2004 Building Technology Micro-Automation and Actuator-Sensor Interface Level ECOFAST IP65 Decentral Automation System and production areas to shipping. Thanks to the system-oriented engineering environment, integrated, open communications as well as intelligent diagnostics options, your plant now benefits in every phase of the life cycle. In fact, to this day we are the only company worldwide that can offer a control system based on an integrated platform for both the production and process industry. Plant Information Management Product Specification Management System Detailed Production Scheduling Laboratory Information Management System SIMATIC IT Framework Production Modeler SIMATIC Controller/ Automation System SENTRON Circuit Breakers SIMATIC Distributed I/O SINUMERIK Numeric Control SIMOTION Motion Control System SIMODRIVE SINAMICS SIMATIC HMI Human Machine Interface SIMATIC PCS 7 Process Control System Field Instrumentation/ Analytics Sensor Technology IQ-Sense SIMOCODE-DP Motor Protection and Control HART PROFIBUS PA SIWAREX Weighing Technology Drive Systems/ SINAMICS Siemens KT10.1 * 2004 1/5 SITOP power Introduction Overview of product families SITOP modular The innovative SITOP modular power supplies feature a completely new concept. The highlight is the modular design comprising a basic unit which can be supplemented by addon modules with further functions. The modularity has no competition with respect to flexibility, simple handling and price/performance ratio. The basic units Compact and rugged basic units for 1-, 2- or 3-phase connection and with output currents from 5 A to 40 A are the basis of the stabilized 24 V supply. The 5 A and 10 A power supply units are unique, and can be connected to almost any network throughout the world thanks to their ultra-wide input range. Each basic unit can be fitted on a DIN rail and already has a comprehensive scope of functions. 5 A and 10 A devices with ultra-wide input range for 1- and 2-phase operation 20 A and 40 A devices for 1- or 3-phase operation Adjustable output voltage up to 28.8 V for compensation of voltage drops 3 LEDs for detailed signalling of the operating status Power boost up to three times the rated current Selectable short-circuit response: constant current or latching shutdown modular Selectable output characteristic for parallel operation 1/6 Siemens KT10.1 * 2004 modular The add-on modules The functionality of the basic units can be expanded using add-on modules. The power supply is optimally integrated into the overall system using the signalling module. Immediate response to various operating statuses is possible and potential damage can be avoided. The buffer module provides effective protection against brief power failures which could lead to a plant standstill, loss of data or even machine damage if the 24 V side is not buffered. A redundancy module can also be used to provide redundant power supply. Thus the 24 V supply is guaranteed even in the worst case when a faulty power supply unit would affect the unit connected in parallel. The SITOP select diagnosis module The diagnosis module is the optimum expansion for all 24 V power supplies in order to divide and monitor the load current among several branch circuits. An overload or short-circuit in a feeder is reliably detected and selectively switched-off. Total failures of plants can be prevented because the 24 V supply for the other loads is maintained. Detailed signalling permits fast fault locating, and thus the minimizing of downtimes. SITOP power Introduction Overview of product families The facets The SITOP power supply units also cover individual power supply requirements - whether standard industrial applications, extreme ambient conditions, or unusual output voltages. The SITOP variants include some true all-rounders: DC UPS SITOP DC UPS The DC UPS modules provide optimum protection against longer power failures. DC UPS modules and battery modules expand SITOP power supply units with 24 V output voltage into uninterruptible power supplies with a rated output current up to 40 A. The transition from power supply mode to buffered mode is absolutely interruption-free. The DC UPS modules are provided as standard with all required protection and monitoring functions, thus providing high availability. The integral battery management function guarantees a long service life for the maintenance-free battery modules. Status messages concerning the operational readiness, battery status and battery lines are signaled by LEDs and floating contacts. The compact 6 A and 15 A DC UPS modules can also communicate via an interface, thus permitting simple integration into PC-based systems. Tried and tested SITOP power 0.5: the mini devices with a width of only 22.5 mm are the narrowest in the SITOP family and are therefore particularly suitable for supplying low-voltage switchgear. SITOP power flexi: unlimited variety thanks to a variable output. The innovative circuit concept permits flexible setting of the output voltage between 3 V and 52 V. Special voltages can therefore also be covered by a standard device. SITOP power dual: the electronics supply for the switchgear cabinet. The DIN rail device is industry-compatible and has two 15 V outputs. For example, for electronic loads to be supplied with 15 V. SITOP power 24 V/2.5 A, 4 A and 10 A: the devices with universal input can be connected to 1-phase AC voltage networks as well as to DC voltage networks. SITOP power 24 V/20 A: the 2-phase primary switched-mode regulator with 20 A rated output current is predestined for industrial networks with high AC voltages. The special widerange input allows connection to 3-phase networks with rated voltages between 500 V and 600 V. SITOP power AS-Interface: 2 primary switched-mode regulators are available especially for powering the actuator/sensor interface: a 2.4 A version with 24 V DC input and IP65 degree of protection, and a 7 A version with wide-range input for AC and DC voltages. Tried and tested The SITOP range of power supply units has proven its reliability for many years already. The units offer graded performances with output currents from 2 A to 20 A and from 10 A to 40 A for single-phase and three-phase incoming supplies respectively. Thanks to the simple handling and numerous certifications, the 24 V power supply units are also suitable for export-oriented use in all standard automation engineering applications. And should it be the case that the power supply conditions are unreliable in a global application, the proven SITOP power supplies can of course also be combined with the DC UPS modules. The facets Siemens KT10.1 * 2004 1/7 SITOP power Introduction Overview of product families SIMATIC design SITOP in SIMATIC design The SITOP power supply units were developed with a design based on the SIMATIC automation systems. However, their special features mean that they can also be optimally used in many other applications. S7-200 design: 24 V/3.5 A. The flat power supply unit with the design of the micro PLC is also particularly suitable for applications with a small overall height and a small switchgear cabinet depth. S7-300 design: 24 V/2 A, 5 A and 10 A. Designed as seriesconnected power supply units for the S7-300 CPUs, they can be simply snapped onto the S7 rail and connected to the CPU by means of a connecting comb. The 2 A and 5 A devices are also available as outdoor versions which are unaffected even by temperatures from -25 C to +70 C or increased shock and vibration load. ET 200B design: 24 V/5 A and 10 A. The devices with a flat design are particularly suitable when only limited mounting depths are available. They find sufficient space even in covered machine racks or pivoted frames. ET 200X design: 24 V/10 A. The 10 A power supply unit with IP65 degree of protection is suitable for the most rugged industrial applications. Permitting any mounting position, the power supply unit for distributed I/Os can handle ambient temperatures from -25 C to +55 C. 1/8 Siemens KT10.1 * 2004 LOGO!Power The mini power supply units are available in two performance classes for output voltages of 5 V, 12 V and 15 V, and in three performance classes for 24 V. Their flat, cascaded profile even permits installation in small distribution boards. The primary switched-mode regulators have been completely innovated and now require even less space for mounting, but with increased functionality. For example, the new function "Constant current in event of overload" even permits the connection of difficult loads. Wide-range input, wide temperature range and many certifications mean that the LOGO! power supply is a universal device for use in numerous applications. LOGO!Power SITOP power 1 Selection guide In order to assist you in finding the right stabilized power supply for each application as quickly as possible, we have assembled the following table as an overview listing all power supplies con- tained in this catalog sorted according to input voltage, output voltage and output current. Selection guide Input voltage Alternating voltage Output voltage Output current Order No. 120 to 230 V AC 5 V DC 3A 6EP1 311-1SH02 page 13/2 6.3 A 6EP1 311-1SH12 page 13/2 1.9 A 6EP1 321-1SH02 page 13/4 4.5 A 6EP1 322-1SH02 page 13/4 1.9 A 6EP1 351-1SH02 page 13/6 4A 6EP1 352-1SH02 page 13/6 2x3.5 A 6EP1 353-0AA00 page 10/2 0.375 A 6EP1 731-2BA00 0.5 A 6EP1 331-2BA10 page 2/2 1.3 A 6EP1 331-1SH02 page 13/8 2A 6EP1 331-2BA00 6EP1 331-1SL11 page 2/2 page 2/3 6ES7 307-1BA00-0AA0 page 2/3 12 V DC 15 V DC 24 V DC Direct voltage 500 to 600 V 400 to 500 V 24 V DC two-phase three-phase AC AC page 2/2 page 2/3 6ES7 305-1BA80-0AA0 page 2/3 6EP1 732-0AA00 2.5 A 6EP1 332-1SH12 page 3/2 6EP1 332-1SH42 page 13/8 3.5 A 6EP1 332-1SH31 page 3/2 4A 6EP1 332-1SH22 page 3/2 6EP1 332-1SH51 page 13/8 6EP1 333-2BA00 page 4/2 6EP1 333-2AA00 page 4/2 6ES7 307-1EA80-0AA0 page 4/3 6ES7 307-1EA00-0AA0 page 4/3 6EP1 333-1AL12 page 4/3 6EP1 333-1SL11 page 4/3 5A 10 A 6EP1 333-3BA00 page 4/2 6EP1 334-2BA00 page 5/2 6EP1 334-2AA00 page 5/2 6EP1 334-2CA00 page 5/3 6ES7 307-1KA01-0AA0 page 5/3 6EP1 334-1SL12 page 5/3 6EP1 334-1AL12 page 5/3 6EP1 334-1SH01 page 5/3 page 3/2 page 3/2 page 7/2 page 7/6 6EP1 434-2BA00 20 A 6EP1 334-3BA00 page 5/2 6EP1 336-3BA00 page 6/2 6EP1 336-2BA00 page 6/3 page 7/2 page 6/3 6EP1 536-2AA00 6EP1 436-2BA00 page 7/6 6EP1 436-3BA00 page 7/3 30 A 6EP1 437-2BA00 40 A 6EP1 337-3BA00 24 to 220 V 120 to 230 V DC DC page 7/7 page 6/2 6EP1 437-3BA00 page 7/3 6EP1 437-2BA10 page 7/7 Continued on page 1/10. Siemens KT10.1 * 2004 1/9 SITOP power 1 Selection guide Selection guide (continued) Input voltage Alternating voltage Output voltage Output current 24 V DC UPS 6A 15 A 48 V DC Order No. Direct voltage 120 to 230 V 500 to 600 V 400 to 500 V 24 V DC AC two-phase three-phase AC AC 6EP1 931-2DC21 page 9/7 6EP1 931-2DC31 page 9/7 6EP1 931-2DC41 page 9/7 6EP1 931-2EC21 page 9/9 6EP1 931-2EC31 page 9/9 6EP1 931-2EC41 page 9/9 40 A 6EP1 931-2FC01 page 9/13 1.2 Ah 6EP1 935-6MC01 page 9/14 2.5 Ah 6EP1 935-6MD31 page 9/15 3.2 Ah 6EP1 935-6MD11 page 9/16 7 Ah 6EP1 935-6ME21 page 9/17 12 Ah 6EP1 935-6MF01 20 A 6EP1 457-3BA00 3-52 V DC 10 A/120 W 6EP1 353-2BA00 30 V DC 2.4 A 6EP1 632-1AL01 AS-Interface 7A 6EP1 354-1AL01 page 9/18 page 10/2 page 10/2 page 11/2 page 11/2 SITOP power 24 V, Additional components Signalling module 6EP1 961-3BA10 page 8/2 Buffer module 40 A 6EP1 961-3BA00 page 8/2 Redundancy module 20 A 6EP1 961-3BA20 page 8/2 6EP1 961-2BA00 page 8/4 Diagnosis module 4x10 A 1/10 Siemens KT10.1 * 2004 24 to 220 V 120 to 230 V DC DC SITOP power * Standard 24 V Single-phase 2/2 2/2 2/3 2/3 2/3 2 Output currents up to 2 A The smallest The proven type The DC/DC converter The S7-300 type The outdoor variant Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase 2 Output currents up to 2 A Overview Application The smallest The proven type The optimum power supply units for automation solutions in the lower performance range; with wide-range input for AC or DC voltages; thanks to their compact and narrow design, they are particularly suitable for solutions where limited space is available and in conjunction with low-voltage switchgear. The tried and tested power supply unit with selectable input voltage range for supplying all standard applications in automation engineering. Technical specifications Power supply, type 0.5 A 0.375 A 2A Order No. 6EP1 331-2BA10 6EP1 731-2BA00 6EP1 331-2BA00 Input Rated voltage Vin rated Single-phase AC 120 to 230 V AC wide-range input DC voltage 48 to 220 V DC wide-range input Single-phase AC 120/230 V AC Settable using wire jumper Voltage range 93 to 264 V AC 30 to 264 V DC (30 to 187 V AC) 93 to 132 V/187 to 264 V AC Overvoltage strength 2.3 x Vin rated, 1.3 ms - 2.3 x Vin rated, 1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 10 ms at Vin = 230 V 50/60 Hz, 47 to 63 Hz 0.22 to 0.13 A < 23 A, typ. 1 ms > 10 ms at Vin = 220 V 0.03 to 0.06 A < 35 A, typ. 3 ms > 10 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 0.9/0.6 A < 14 A, typ. 3 ms I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line 0.3 A2s T 2 A/250 V (not accessible) From 3 A, Characteristic C 1.2 A2s F 4 A/250 V (not accessible) From 6 A, Characteristic C, DC-suitable < 0.3 A2s T 1.6 A/250 V (not accessible) From 3 A, Characteristic C Output Rated voltage Vout rated Total tolerance * Stat. mains compensation * Stat. load compensation Stabilized, floating direct voltage 24 V DC 3% Approx. 0.2 % Approx. 0.7 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.1 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.8 % Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) Setting range Status display Power ON/OFF behavior < 150 mVpp (typ. 50 mVpp) < 150 mVpp (typ. 50 mVpp) < 150 mVpp < 240 mVpp (typ. 150 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 240 mVpp (typ. 50 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 240 mVpp 22.8 to 26.4 V Green LED for 24 V O.K. No overshoot of Vout (soft start) Starting delay/voltage rise Rated current Iout rated Current range * Up to +45 C * Up to +60 C < 1.5 s/typ. 20 ms 0.5 A < 2.5 s/typ. 90 ms 0.375 A < 3 s/typ. 80 ms 2A 0 to 0.5 A 0 to 0.5 A (up to +70 C) 0 to 0.375 A 0 to 0.375 A 0 to 2 A 0 to 2 A Approx. 0.6 A constant current Approx. 0.6 A constant current Not permissible typ. 2.7 A for 200 ms Not permissible typ. 7 A for 300 ms Yes, 2 Dyn. V/I with * Starting on short circuit * Short-circuit in operation Parallel connection for increased output Continued on page 2/4. 2/2 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase Output currents up to 2 A The DC/DC converter The S7-300 type The outdoor variant The DC/DC converter for supply from battery and DC networks, with a wide input voltage range from 38 V to 121 V DC. The proven power supply in the SIMATIC S7-300 design; alternatively with PS-CPU connecting comb and for snap-mounting on S7 busbar (Order No. 6ES7307-1BA00-0AA0) or without PS-CPU connecting comb for snap-mounting on DIN rail EN 500022-35x15 via mounting adapter (Order No. 6EP1 331-1SL11). The power supply unit for extreme environmental conditions with SIMATIC S7-300 design, can be snapped onto S7 rail; with PS-CPU connecting comb. 2A 2A 2A 2A 6EP1 732-0AA00 6ES7307-1BA00-0AA0 6EP1 331-1SL11 6ES7 305-1BA80-0AA0 1) DC voltage 48 to 110 V DC wide-range input Single-phase AC 120/230 V AC Settable via selector switch on device 85 to 132 V/170 to 264 V AC DC voltage 24 to 110 V DC wide-range input 38 to 121 V DC Single-phase AC 120/230 V AC Settable via selector switch on device 85 to 132 V/170 to 264 V AC 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms 154 V; 0.1 s > 5 ms at Vin = 48 V 1.2 to 0.5 A < 33 A > 20 ms at Vin = 93/187 V 50/60 Hz, 47 to 63 Hz 0.9/0.6 A < 20 A, < 3 ms > 20 ms at Vin = 93/187 V 50/60 Hz, 47 to 63 Hz 0.9/0.6 A < 20 A, < 3 ms > 10 ms at Vin rated 2.7 to 0.6 A (4 to 0.9 A) < 20 A, < 10 ms < 1.0 A2s T 1.6 A/250 V (not accessible) 3 A, Characteristic C < 1.0 A2s T 1.6 A/250 V (not accessible) 3 A, Characteristic C < 5 A2s T 6.3 A/250 V (not accessible) From 10 A, Characteristic C, DC-suitable Stabilized, floating direct voltage 24 V DC 1% Approx. 0.1 % Approx. 0.4 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.2 % Approx. 0.4 % < 100 mVpp < 150 mVpp (typ. < 20 mVpp) < 150 mVpp (typ. < 20 mVpp) < 150 mVpp (typ. < 30 mVpp) < 300 mVpp Green LED for 24 V O.K. Overshoots of Vout when switching on max. 25 V < 240 mVpp (typ. < 150 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 240 mVpp (typ. < 150 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 240 mVpp (typ. < 150 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 3 s/typ. 30 ms 2A < 3 s/typ. 60 ms 2A < 3 s/typ. 60 ms 2A < 3 s (typ. 7 ms)/typ. 5 ms 2 A (3 A at Vin > 24 V) 0 to 2 A 0 to 2 A (up to +70 C) 0 to 2 A 0 to 2 A 0 to 2 A 0 to 2 A 0 to 2 A (3 A) 0 to 2 A (3 A) Yes, 2 typ. 10 A for 90 ms typ. 10 A for 90 ms Not permissible typ. 10 A for 90 ms typ. 10 A for 90 ms Not permissible typ. 9 A for 270 ms typ. 9 A for 270 ms Yes, 2 T 2.5 A (not accessible) 10 to 25 A, Characteristic B, or 6 to 25 A, Characteristic C, DC-suitable 16.8 to 138 V DC Continued on page 2/5. 1) SIPLUS module 6AG1 307-1BA80-2AA0 for enhanced temperature range -25 to +60 C and use under medium load (e.g. chlorine/sulfur atmosphere). Conformity with EN 50155 available soon (electrical equipment on track vehicles). Siemens KT10.1 * 2004 2/3 2 SITOP power * Standard 24 V Single-phase 2 Output currents up to 2 A Power supply, type 0.5 A 0.375 A 2A Order No. 6EP1 331-2BA10 6EP1 731-2BA00 6EP1 331-2BA00 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 74 % Approx. 4.2 W Approx. 66 % Approx. 4.6 W Approx. 82 % Approx. 11 W Approx. 0.3 % Vout Approx. 0.3 % Vout Approx. 0.3 % Vout 0.7 % Vout 0.4 % Vout 2 % Vout Settling time * Load step from 50 to 100 % * Load step from 100 to 50 % typ. 1.5 ms typ. 1.5 ms typ. 2 ms typ. 2 ms typ. 0.5 ms typ. 0.5 ms Protection and monitoring Output overvoltage protection Yes, acc. to EN 60950 Yes, acc. to EN 60950 Yes, acc. to EN 60950 Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 50/100/50 %) Current limitation 0.55 to 0.65 A 0.41 to 0.49 A typ. 2.2 to 2.6 A Short-circuit protection RMS sustained short-circuit current Overload/short-circuit indicator Stabilized current characteristic down to 0 V < 0.65 A - Electronic shutdown, automatic restart < 0.9 A - Electronic shutdown, automatic restart <4A - Safety Galvanic isolation primary/secondary Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Yes, SELV output voltage Vout acc. to EN 60950 Protective class Discharge current Class I < 3.5 mA Class I < 3.5 mA Class I < 3.5 mA (typ. 0.17 mA) TUV test CE marking UL/cUL (CSA) approval Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-95), File E143289; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-95), File E143289; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 Yes; CB scheme Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) FM approval - - - Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 -20 to +70 C with natural convection -20 to +70 C with natural convection, derating above 60 C 0 to +60 C with natural convection -40 to +70 C -40 to +70 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 Dimensions (W x H x D) in mm Weight approx. Mounting 22.5 x 80 x 91 0.11 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 22.5 x 80 x 91 0.14 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 50 x 125 x 125 0.38 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Accessories - - - Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections * Mains input L, N, PE (DC input: L+1, M1, PE) * Output L+ * Output M 2/4 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase Output currents up to 2 A 2A 2A 2A 2A 6EP1 732-0AA00 6ES7307-1BA00-0AA0 6EP1 331-1SL11 6ES7 305-1BA80-0AA0 Approx. 84 % Approx. 9 W Approx. 83 % Approx. 10 W Approx. 83 % Approx. 10 W Approx. 75 % Approx. 16 W (24 W) 0.3 % Vout 0.3 % Vout 0.3 % Vout 0.3 % Vout 0.8 % Vout 0.8 % Vout 0.8 % Vout 2.5 % Vout < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) Yes, suppressor diode at output typ. 2.1 to 3 A Additional control loop, shutdown at approx. 30 V, automatic restart 2.2 to 2.6 A Additional control loop, shutdown at approx. 30 V, automatic restart 2.2 to 2.6 A Additional control loop, shutdown at approx. 30 V, automatic restart 3.3 to 3.9 A Electronic shutdown, automatic restart <2A - Electronic shutdown, automatic restart <4A - Electronic shutdown, automatic restart <4A - Electronic shutdown, automatic restart <2A - Yes, SELV output voltage Vout acc. to EN 60950 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.7 mA) Class I < 3.5 mA (typ. 0.7 mA) Class I < 3.5 mA (typ. 0.7 mA) Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178, clearance and creepage distances > 5 mm Class I < 3.5 mA (typ. 0.7 mA) Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E179336 Yes Yes Yes, UL listed (UL 508), File E143289, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, UL listed (UL 508), File E143289, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, UL listed (UL 508), File E143289, CSA (CSA 22.2 No. 14-95) - Yes, Class I Div. 2 Group A, B, C, D T4 in the S7-300 system IP20 - IP20 Yes, Class I Div. 2 Group A, B, C, D T4 in the S7-300 system IP20 Yes, GL, LRS IP20 EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 EN 55011 Class A Not applicable EN 61000-6-2 0 to +70 C with natural convection 0 to +60 C with natural convection 0 to +60 C with natural convection -25 to +70 C with natural convection -40 to +70 C -40 to +85 C -40 to +85 C -40 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K5 acc. to EN 60721, brief condensation permissible One screw-type terminal each for 2 x 0.5 to 2.5/1.5 mm2 singlecore/finely stranded 1 screw-type terminal for 2 x 0.5 to 2.5 mm2 1 screw-type terminal for 2 x 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 80 x 135 x 120 0.5 kg Snap-mounting on DIN rail EN 50022-35x15 50 x 125 x 120 0.42 kg Snap-mounting on S7 rail 50 x 125 x 135 0.42 kg Snap-mounting on DIN rail EN 50022-35x15 80 x 125 x 120 0.75 kg Snap-mounting on S7 rail - Mounting adapter for DIN rail and PS-CPU connecting comb Mounting adapter for DIN rail and PS-CPU connecting comb Mounting adapter for DIN rail and PS-CPU connecting comb Siemens KT10.1 * 2004 2/5 2 SITOP power * Standard 24 V Single-phase 2 Notes 2/6 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase 3/2 3/2 3 Output currents 2.5 to 4 A The universal types The S7-200 type Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase Output currents 2.5 to 4 A Overview The universal types The S7-200 type The universal power supply units for all supply networks, with a wide-range input from 93 V to 264 V AC and 110 V to 350 V DC for supply from all typical networks. Power supply unit whose design and functionality are optimally matched to the SIMATIC S7-200 micro PLC; flat design, particularly suitable for low control cabinet depths. 3 Application Technical specifications Power supply, type 2.5 A 4A 3.5 A Order No. 6EP1 332-1SH12 6EP1 332-1SH22 6EP1 332-1SH31 Input Rated voltage Vin rated Single-phase AC or DC 120 to 230 V AC wide-range input 93 to 264 V AC or 110 to 350 V DC Single-phase AC or DC 120 to 230 V AC wide-range input 93 to 264 V AC or 110 to 350 V DC Single-phase AC 120/230 V AC Settable using wire jumper 93 to 132 V/187 to 264 V AC Overvoltage strength 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms Mains buffering at Iout rated > 20 ms at Vin = 120 V, > 80 ms (typ. 100 ms) at Vin = 187 V 0/50/60 Hz, 47 to 63 Hz 1.3 to 0.7 A < 33 A, < 3 ms (Vin = 230 V) > 20 ms at Vin = 120 V, > 80 ms (typ. 100 ms) at Vin = 187 V 0/50/60 Hz, 47 to 63 Hz 1.8 to 1.1 A < 33 A, < 3 ms (Vin = 230 V) > 20 ms at Vin = 187 V I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 3.5 A2s T 3.15 A (not accessible) Two-pole circuit-breaker from 10 A, Characteristic C or from 6 A, Characteristic D < 3.5 A2s T 3.15 A (not accessible) Two-pole circuit-breaker from 10 A, Characteristic C or from 6 A, Characteristic D < 1.0 A2s T 2.5 A/250 V (not accessible) Two-pole circuit-breaker from 10 A, Characteristic C or from 6 A, Characteristic D Output Rated voltage Vout rated Total tolerance * Stat. mains compensation * Stat. load compensation Stabilized, floating direct voltage 24 V DC 1% Approx. 0.1 % Approx. 0.2 % Stabilized, floating direct voltage 24 V DC 1% Approx. 0.1 % Approx. 0.2 % Stabilized, floating direct voltage 24 V DC 5 % (typ. 2 %) Approx. 0.1 % Approx. 0.2 % Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) Setting range Status display Power ON/OFF behavior < 50 mVpp (typ. 40 mVpp) < 50 mVpp (typ. 40 mVpp) < 150 mVpp (typ. 30 mVpp) < 100 mVpp (typ. 40 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 100 mVpp (typ. 40 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 240 mVpp (typ. 110 mVpp) No overshoot of Vout (soft start) Starting delay/voltage rise Rated current Iout rated Current range * Up to +45 C * Up to +60 C < 0.6 s/typ. 20 ms 2.5 A < 0.6 s/typ. 20 ms 4A < 1 s/typ. 80 ms 3.5 A 0 to 2.5 A 0 to 2.5 A 0 to 4 A 0 to 2.5 A 0 to 3.5 A 0 to 3.5 A Approx. 2.8 A constant current Approx. 2.8 A constant current Yes, up to 10 Approx. 4.4 A constant current Approx. 4.4 A constant current Yes, up to 10 typ. 5 A for 100 ms typ. 5 A for 100 ms Yes, up to 5 Voltage range Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) Dyn. V/I with * Starting on short circuit * Short-circuit in operation Parallel connection for increased output Continued on page 3/3. 3/2 Siemens KT10.1 * 2004 50/60 Hz, 47 to 63 Hz 1.65/0.95 A < 33 A, < 3 ms (Vin = 230 V) SITOP power * Standard 24 V Single-phase Output currents 2.5 to 4 A Power supply, type 2.5 A 4A 3.5 A Order No. 6EP1 332-1SH12 6EP1 332-1SH22 6EP1 332-1SH31 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 85 % Approx. 11 W Approx. 85 % Approx. 17 W Approx. 84 % Approx. 16 W 0.3 % Vout 0.3 % Vout 0.3 % Vout typ. 0.5 % Vout typ. 0.5 % Vout < 10 % Vout (typ. 3 % Vout) < 2 ms (typ. 1 ms) < 2 ms (typ. 1 ms) < 2 ms (typ. 1 ms) < 2 ms (typ. 1 ms) < 5 ms < 5 ms Control Dyn. mains compensation, typ. (Vin rated 15 %) Dyn. load compensation (Iout: 50/100/50 %) Settling time * Load step from 50 to 100 % * Load step from 100 to 50 % Protection and monitoring Output overvoltage protection Current limitation 3 2.8 A 4.4 A 3.8 A Short-circuit protection Stabilized current characteristic down to 0 V Stabilized current characteristic down to 0 V RMS sustained short-circuit current Overload/short-circuit indicator <3A - <5A - Stabilized current characteristic to typ. 14 V, electronic shutdown below that, automatic restart <4A - Safety Galvanic isolation primary/secondary Protective class Discharge current Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA TUV test CE marking UL/cUL (CSA) approval Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 FM approval Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 0 to +60 C with natural convection 0 to +50 C with natural convection 0 to +60 C with natural convection -25 to +85 C -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 2 x 0.5 to 1.5 mm2 finely stranded, 2 x 0.5 to 2.5 mm2 single-core 1 screw-type terminal for 2 x 0.5 to 2.5 mm2 1 screw-type terminal for 2 x 0.5 to 2.5 mm2 One screw-type terminal each for 2 x 0.5 to 1.5 mm2 finely stranded, 2 x 0.5 to 2.5 mm2 single-core 1 screw-type terminal for 2 x 0.5 to 2.5 mm2 1 screw-type terminal for 2 x 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 1 mm2 finely stranded, 0.5 to 1.5 mm2 single-core Dimensions (W x H x D) in mm Weight approx. Mounting 80 x 135 x 120 80 x 135 x 120 160 x 80 x 62 0.5 kg Snap-mounting on DIN rail EN 50022-35x15, wall mounting 0.5 kg Snap-mounting on DIN rail EN 50022-35x15, wall mounting 0.5 kg Snap-mounting on DIN rail EN 50022-35x15/7.5, wall mounting Accessories - - Mounting bracket Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections * Mains input L, N, PE * Output L+ * Output M 1 screw-type terminal for 0.5 to 1 mm2 2 screw-type terminals for 0.5 to 1 mm2 Siemens KT10.1 * 2004 3/3 SITOP power * Standard 24 V Single-phase Notes 3 3/4 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase 4/2 4/2 4/3 4/3 4/3 4 Output current 5 A SITOP modular The proven types The S7-300 type The outdoor variant The flat design Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output current 5 A Overview SITOP modular The proven types The modular power supply unit with single-phase and two-phase wide-range inputs for global use in many different fields of application; expansion of functions possible using add-on modules. The tried and tested power supply unit with selectable input voltage range for supplying all standard applications in automation engineering; 6EP1333-2AA00 without limitation of input current harmonics. Power supply, type 5A 5A 5A Order No. 6EP1 333-3BA00 6EP1 333-2BA00 6EP1 333-2AA00 Input Rated voltage Vin rated Single-phase AC 120/230 V AC Settable using wire jumper Single-phase AC 120/230 V AC Settable using wire jumper Voltage range Single and two-phase AC 120/230 to 500 V AC Settable via selector switch on device 85 to 132 V/176 to 550 V AC 93 to 132 V/187 to 264 V AC 93 to 132 V/187 to 264 V AC Overvoltage strength 1300 Vpeak, 1.3 ms 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 25 ms at Vin = 120/230 V 50/60 Hz; 47 to 63 Hz 2.2 /1.2 to 0.61 A < 35 A > 10 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 2.2/0.9 A < 32 A, typ. 3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 2.2/1.3 A < 32 A, typ. 3 ms I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 1.7 A2s T 3, 15 A (not accessible) From 6 A (10 A) Characteristic C (B); with two-phase operation: circuit-breaker with two-pole connection or motor circuitbreaker 3RV1021-1EA10 < 0.8 A2s T 3.15 A/250 V (not accessible) From 6 A, Characteristic C < 0.8 A2s T 3.15 A/250 V (not accessible) From 6 A, Characteristic C Output Rated voltage Vout rated Total tolerance * Stat. mains compensation * Stat. load compensation Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.1 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) < 50 mVpp (typ. 10 mVpp) < 150 mVpp < 150 mVpp < 200 mVpp (typ. 20 mVpp) < 240 mVpp < 240 mVpp Setting range Status display Power ON/OFF behavior 24 to 28.8 V (max. 120 W) Green LED for 24 V O.K. Overshoot of Vout approx. 3 % 22.8 to 26.4 V Green LED for 24 V O.K. No overshoot of Vout (soft start) 22.8 to 26.4 V Green LED for 24 V O.K. No overshoot of Vout (soft start) Starting delay/voltage rise Rated current Iout rated Current range * Up to +45 C * Up to +60 C < 1 s/< 50 ms 5A < 3 s/typ. 80 ms 5A < 3 s/typ. 80 ms 5A 0 to 5 A 0 to 5 A 0 to 5 A 0 to 5 A 0 to 5 A 0 to 5 A Dyn. V/I with * Starting on short circuit * Short-circuit in operation Parallel connection for increased output Approx. 5.5 A constant current typ. 15 A for 25 ms Yes, 2 (selectable current characteristic) typ. 20 A for 350 ms Yes, 2 typ. 20 A for 350 ms Yes, 2 4 Application Technical specifications Continued on page 4/4. 4/2 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output current 5 A The S7-300 type The outdoor variant The flat design 4 The proven power supply in the SIMATIC S7-300 design; alternatively with PS-CPU connecting comb for snap-mounting on S7 busbar (Order No. 6ES7307-1EA00-0AA0) or without PS-CPU connecting comb for snap-mounting on DIN rail EN 50002235x15 via mounting adapter (Order No. 6EP1 333-1SL11). The power supply unit for extreme environmental conditions with SIMATIC S7-300 design, can be snapped onto S7 rail; with PS-CPU connecting comb. The flat design which is of great advantage where only low mounting depths are available, e.g. for use with distributed I/O, in machine benches or alcoves; design matched to SIMATIC ET 200B. 5A 5A 5A 5A 6ES7 307-1EA00-0AA0 6EP1 333-1SL11 6ES7 307-1EA80-0AA0 1) 6EP1 333-1AL12 Single-phase AC 120/230 V AC Settable via selector switch on device 85 to 132 V/170 to 264 V AC Single-phase AC 120/230 V AC Settable via selector switch on device 85 to 132 V/170 to 264 V AC Single-phase AC 120/230 V AC Settable via selector switch on device 93 to 132 V/187 to 264 V AC Single-phase AC 120/230 V AC Settable via selector switch on device 85 to 132 V/170 to 264 V AC 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 2.1/1.3 A < 45 A, < 3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 2.1/1.3 A < 45 A, < 3 ms > 20 ms at Vin = 93/187 V 50/60 Hz, 47 to 63 Hz 2.1/1.2 A < 45 A, < 3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 2.2/1.2 A < 32 A, < 3 ms < 1.2 A2s F 4 A/250 V (not accessible) From 6 A, Characteristic C < 1.2 A2s F 4 A/250 V (not accessible) From 6 A, Characteristic C < 1.8 A2s (typ. 1.2 A2s) T 3.15 A/250 V (not accessible) From 10 A, Characteristic C or from 6 A, Characteristic D < 0.8 A2s T 3.15 A/250 V (not accessible) From 6 A, Characteristic C Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.2 % Approx. 0.4 % Stabilized, floating direct voltage 24 V DC 1% Approx. 0.1 % Approx. 0.5 % < 150 mVpp (typ. 40 mVpp) < 150 mVpp (typ. 40 mVpp) < 150 mVpp (typ. 40 mVpp) < 150 mVpp (typ. 40 mVpp) < 240 mVpp (typ. 90 mVpp) < 240 mVpp (typ. 90 mVpp) < 240 mVpp (typ. 90 mVpp) < 240 mVpp (typ. 100 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) Green LED for 24 V O.K. No overshoot of Vout (soft start) Green LED for 24 V O.K. No overshoot of Vout (soft start) 22 to 29 V Green LED for 24 V O.K. No overshoot of Vout (soft start) < 2 s/typ. 60 ms 5A < 2 s/typ. 60 ms 5A < 3 s/typ. 100 ms 5A < 2 s/typ. 40 ms 5A 0 to 5 A 0 to 5 A 0 to 5 A 0 to 5 A 0 to 5 A 0 to 5 A 0 to 5 A 0 to 5 A typ. 20 A for 75 ms typ. 20 A for 75 ms Not permissible typ. 20 A for 75 ms typ. 20 A for 75 ms Not permissible typ. 20 A for 180 ms typ. 20 A for 80 ms Not permissible typ. 20 A for 500 ms typ. 20 A for 500 ms Yes, 2 Continued on page 4/5. 1) SIPLUS module 6AG1 307-1EA80-2AA0 for enhanced temperature range -25 to +60 C and use under medium load (e.g. chlorine/sulfur atmosphere). Conformity with EN 50155 available soon (electrical equipment on track vehicles). Siemens KT10.1 * 2004 4/3 SITOP power * Standard 24 V Single-phase and two-phase Output current 5 A 4 Power supply, type 5A 5A 5A Order No. 6EP1 333-3BA00 6EP1 333-2BA00 6EP1 333-2AA00 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 87 % Approx. 18 W Approx. 87 % Approx. 18 W Approx. 87 % Approx. 18 W Approx. 0.1% Approx. 0.3 % Vout Approx. 0.3 % Vout Approx. +3 % Vout 2.5 % Vout 2.5 % Vout Settling time * Load step from 50 to 100 % < 5 ms (typ. 2 ms) typ. 0.2 ms typ. 0.2 ms * Load step from 100 to 50 % < 5 ms (typ. 2 ms) typ. 0.2 ms typ. 0.2 ms Protection and monitoring Output overvoltage protection < 35 V Yes, acc. to EN 60950 Yes, acc. to EN 60950 Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 50/100/50 %) Current limitation typ. 5.5 A typ. 5.5 to 6.5 A typ. 5.5 to 6.5 A Short-circuit protection Choice of stabilized current characteristic approx. 5.5 A or latching shutdown Approx. 5.5 A Yellow LED for "overload", red LED for "latching shutdown" Electronic shutdown, automatic restart Electronic shutdown, automatic restart < 17 A - < 17 A - Safety Galvanic isolation primary/secondary Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Yes, SELV output voltage Vout acc. to EN 60950 Yes, SELV output voltage Vout acc. to EN 60950 Protective class Discharge current Class I < 3.5 mA (typ. 0.25 mA) Class I < 3.5 mA (typ. 0.4 mA) Class I < 3.5 mA (typ. 0.4 mA) TUV test CE marking UL/cUL (CSA) approval Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E197259 Yes; CB scheme Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes; CB scheme Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) FM approval - - - Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-6-2 0 to +60 C with natural convection 0 to +60 C with natural convection 0 to +60 C with natural convection -25 to +85 C -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.2 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals for 0.2 to 2.5 mm2 2 screw-type terminals for 0.2 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 Dimensions (W x H x D) in mm Weight approx. Mounting 70 x 125 x 125 1.2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 75 x 125 x 125 0.75 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 75 x 125 x 125 0.57 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Accessories Buffer module (6EP1961-3BA00) Signalling module (6EP19613BA10) Redundancy module (6EP19613BA20) - - RMS sustained short-circuit current Overload/short-circuit indicator Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections * Mains input L, N, PE * Output L+ * Output M 4/4 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output current 5 A 5A 5A 5A 5A 6ES7 307-1EA00-0AA0 6EP1 333-1SL11 6ES7 307-1EA80-0AA0 6EP1 333-1AL12 Approx. 87 % Approx. 18 W Approx. 87 % Approx. 18 W Approx. 84 % Approx. 23 W Approx. 88 % Approx. 17 W 0.3 % Vout 0.3 % Vout 0.3 % Vout 0.3 % Vout 2.5 % Vout 2.5 % Vout 3 % Vout 0.5 % Vout typ. 0.1 ms typ. 0.1 ms < 5 ms (typ. 0.2 ms) < 5 ms (typ. 0.1 ms) typ. 0.1 ms typ. 0.1 ms < 5 ms (typ. 0.2 ms) < 5 ms (typ. 0.1 ms) Additional control loop, shutdown at approx. 30 V, automatic restart 5.5 to 6.5 A Additional control loop, shutdown at approx. 30 V, automatic restart 5.5 to 6.5 A Additional control loop, shutdown at approx. 30 V, automatic restart 5.5 to 6.5 A Additional control loop, shutdown at approx. 33 V, automatic restart 5.5 to 6.5 A Electronic shutdown, automatic restart Electronic shutdown, automatic restart Electronic shutdown, automatic restart Electronic shutdown, automatic restart <9A - <9A - <5A - <5A - Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.3 mA) Class I < 3.5 mA (typ. 0.3 mA) Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178, clearance and creepage distances > 8 mm Class I < 3.5 mA (typ. 0.3 mA) Yes Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E197259 Yes, Class I Div. 2 Group A, B, C, D, T 4 in the S7-300 system IP20 Yes, Class I Div. 2 Group A, B, C, D, T 4 in the S7-300 system IP20 - - Yes, GL, LRS IP20 IP20 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55011 Class A EN 61000-6-2 EN 55022 Class B EN 61000-6-2 0 to +60 C with natural convection 0 to +60 C with natural convection -40 to +70 C with natural convection 0 to +60 C with natural convection -40 to +85 C -40 to +85 C -40 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K5 acc. to EN 60721, brief condensation permissible Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 80 x 125 x 120 0.74 kg Snap-mounting on S7 rail 80 x 125 x 135 0.74 kg Snap-mounting on DIN rail EN 50022-35x15 80 x 125 x 120 0.57 kg Snap-mounting on S7 rail 160 x 130 x 60 0.6 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Mounting adapter for DIN rail and connecting comb Mounting adapter for DIN rail and connecting comb Mounting adapter for DIN rail and connecting comb Mounting bracket 4 Class I < 3.5 mA (typ. 0.26 mA) Siemens KT10.1 * 2004 4/5 SITOP power * Standard 24 V Single-phase and two-phase Notes 4 4/6 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase 5/2 5/2 5/3 5/3 5/3 5/3 5 Output current 10 A SITOP modular The proven types The IP65 version The S7-300 type The flat design The universal type Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output current 10 A Overview 5 Application SITOP modular The proven types The modular power supply unit with single-phase and two-phase wide-range inputs for global use in many different fields of application; expansion of functions possible using add-on modules. The tried and tested power supply unit with selectable input voltage range for supplying all standard applications in automation engineering; 6EP1334-2AA00 without limitation of input current harmonics. Technical specifications Power supply, type 10 A 10 A 10 A Order No. 6EP1 334-3BA00 6EP1 334-2BA00 6EP1 334-2AA00 Input Rated voltage Vin rated Single and two-phase AC 120/230 to 500 V AC Settable via selector switch on device 85 to 132/176 to 550 V AC Single-phase AC 120/230 V AC Settable using wire jumper Single-phase AC 120/230 V AC Settable using wire jumper 85 to 132/187 to 264 V AC 85 to 132/187 to 264 V AC Overvoltage strength 1300 Vpeak, 1.3 ms 2.3 x Vin rated, 1.3ms 2.3 x Vin rated, 1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 25 ms at Vin = 120/230 V 50/60 Hz; 47 to 63 Hz 4.4 /2.4 to 1.1 A < 35 A > 10 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 5.5/2.1 A < 65 A, typ. 3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 5.5/3.2 A < 65 A, typ. 3 ms I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 4.0 A2s T 6.3 A (not accessible) From 6 A (10 A) Characteristic C (B); with two-phase operation: circuit-breaker with two-pole connection or motor circuitbreaker 3RV1021-1EA10 < 3.3 A2s T 6.3 A/250 V (not accessible) From 10 A, Characteristic C < 3.3 A2s T 6.3 A/250 V (not accessible) From 10 A, Characteristic C Output Rated voltage Vout rated Total tolerance * Stat. mains compensation * Stat. load compensation Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.1 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.2 % Approx. 1 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.2 % Approx. 1 % Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) < 50 mVpp (typ. 10 mVpp) < 150 mVpp < 150 mVpp < 200 mVpp (typ. 20 mVpp) < 240 mVpp < 240 mVpp Setting range Status display Power ON/OFF behavior 24 to 28.8 V (max. 240 W) Green LED for 24 V O.K. Overshoot of Vout approx. 3% 22.8 to 28.8 V Green LED for 24 V O.K. No overshoot of Vout (soft start) 22.8 to 28.8 V Green LED for 24 V O.K. No overshoot of Vout (soft start) Starting delay/voltage rise Rated current Iout rated Current range * Up to +45 C * Up to +60 C < 1 s/< 50 ms 10 A < 3 s/typ. 80 ms 10 A < 3 s/typ. 80 ms 10 A 0 to 10 A 0 to 10 A 0 to 12 A 0 to 10 A 0 to 12 A 0 to 10 A Dyn. V/I with * Starting on short circuit * Short-circuit in operation Parallel connection for increased output Approx. 12 A constant current typ. 30 A for 25 ms Yes, 2 (selectable current characteristic) typ. 38 A for 200 ms Yes, 2 typ. 38 A for 200 ms Yes, 2 Voltage range Continued on page 5/4. 5/2 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output current 10 A The IP65 version The S7-300 type The flat design The universal type Power supply unit with IP65 degree of protection, design and functionality optimally matched to ET 200X distributed I/O devices. When using without ET 200X, the connector seal accessory is required. The proven power supply in the SIMATIC S7-300 design; alternatively with PS-CPU connecting comb for snapmounting on S7 busbar or without connecting comb for snap-mounting on DIN rail EN 500022-35x15 via mounting adapter. The flat design which is of great advantage where only low mounting depths are available, e.g. for use with distributed I/O, in machine benches or alcoves; design matched to SIMATIC ET 200B. The universal power supply unit for all supply networks, with a wide-range input from 93 V to 264 V AC and 110 V to 350 V DC for supply from all typical networks. 10 A 10 A 10 A 10 A 6EP1 334-2CA00 6ES7 307-1KA01-0AA0 / 6EP1334-1SL12 6EP1 334-1AL12 6EP1 334-1SH01 Single-phase AC 120/230 V AC Settable using wire jumper Single-phase AC 120/230 V AC Settable via selector switch on device 85 to 132/170 to 264 V AC Single-phase AC 120/230 V AC Settable via selector switch on device 85 to 132/170 to 264 V AC Single-phase AC 120 to 230 V AC wide-range input 2.3 x Vin rated, 1.3ms 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms > 20 ms at Vin = 93/187 V 50/60 Hz, 47 to 63 Hz 4.3/2.6 A < 65 A, typ. 3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 4.1/1.8 A < 55 A, < 3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 to 63 Hz 4/2.5 A < 65 A, < 3 ms > 20 ms at Vin = 93/187 V 0/50/60 Hz; 47 to 63 Hz 2.5 to 1.3 A < 20 A, < 3 ms < 2.5 A2s T 6.3 A/250 V (not accessible) From 16 A, Characteristic C < 3.3 A2s T 6.3 A/250 V (not accessible) From 10 A, Characteristic C < 3.3 A2s T 6.3 A/250 V (not accessible) From 10 A, Characteristic C < 1.5 A2s T 6.3 A (not accessible) From 16 A, Characteristic C Stabilized, floating direct voltage 24 V DC 3% Approx. 0.2 % Approx. 1 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.5 % Stabilized, floating direct voltage 24 V DC 1% Approx. 0.1 % Approx. 0.5 % Stabilized, floating direct voltage 24 V DC 1% < 0.1 % < 0.2 % < 150 mVpp < 150 mVpp (typ. 40 mVpp) < 150 mVpp (typ. 50 mVpp) < 100 mVpp < 240 mVpp < 240 mVpp (typ. 100 mVpp) < 240 mVpp (typ. 200 mVpp) < 100 mVpp 22.8 to 25.2 V Green LED for 24 V O.K. No overshoot of Vout (soft start) Green LED for 24 V O.K. No overshoot of Vout (soft start) 22 to 29 V Green LED for 24 V O.K. No overshoot of Vout (soft start) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 3 s/typ. 80 ms 10 A < 1.5 s/typ. 80 ms 10 A < 2 s/typ. 40 ms 10 A < 3 s/typ. 100 ms 10 A 0 to 10 A (up to +40 C) 0 to 8 A (up to +55 C) 0 to 10 A 0 to 10 A 0 to 10 A 0 to 10 A 0 to 10 A 0 to 10 A typ. 38 A for 200 ms Yes, 2 typ. 35 A for 80 ms typ. 35 A for 150 ms Not permissible typ. 35 A for 700 ms typ. 35 A for 700 ms Yes, 2 Approx. 11 A constant current Approx. 11 A constant current Yes, 2 93 to 132/187 to 264 V AC 93 to 264 V AC or 110 to 350 V DC Continued on page 5/5. Siemens KT10.1 * 2004 5/3 5 SITOP power * Standard 24 V Single-phase and two-phase Output current 10 A Power supply, type 10 A 10 A 10 A Order No. 6EP1 334-3BA00 6EP1 334-2BA00 6EP1 334-2AA00 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 87 % Approx. 36 W Approx. 89 % Approx. 30 W Approx. 89 % Approx. 30 W Approx. 0.1 % Approx. 0.3 % Vout Approx. 0.3 % Vout Approx. +3 % Vout 5 % Vout 5 % Vout Settling time * Load step from 50 to 100 % * Load step from 100 to 50 % < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms) typ. 0.2 ms typ. 0.2 ms typ. 0.2 ms typ. 0.2 ms Protection and monitoring Output overvoltage protection < 35 V Yes, acc. to EN 60950 Yes, acc. to EN 60950 Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 50/100/50 %) 5 Current limitation typ. 12 A typ. 13 to 15 A typ. 13 to 15 A Short-circuit protection Choice of stabilized current characteristic approx. 12 A or latching shutdown Approx. 12 A Yellow LED for "overload", red LED for "latching shutdown" Electronic shutdown, automatic restart Electronic shutdown, automatic restart < 21 A - < 21 A - Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.32 mA) Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA (typ. 0.4 mA) Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA (typ. 0.4 mA) TUV test CE marking UL/cUL (CSA) approval Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91) File E197259 Yes; CB scheme Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes; CB scheme Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) FM approval Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-6-2 0 to +60 C with natural convection 0 to +60 C with natural convection 0 to +60 C with natural convection -25 to +85 C -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.2 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals for 0.2 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.5 to 2.5 mm2 * Output M 2 screw-type terminals for 0.2 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 Dimensions (W x H x D) in mm 90 x 125 x 125 100 x 125 x 135 100 x 125 x 135 Weight approx. Mounting 1.4 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 1.08 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 0.78 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Accessories Buffer module (6EP1961-3BA00) Signalling module (6EP19613BA10) Redundancy module (6EP19613BA20) - - RMS sustained short-circuit current Overload/short-circuit indicator Safety Galvanic isolation primary/secondary Protective class Discharge current Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections * Mains input L, N, PE * Output L+ 5/4 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output current 10 A 10 A 10 A 10 A 10 A 6EP1 334-2CA00 6ES7 307-1KA01-0AA0 / 6EP1334-1SL12 6EP1 334-1AL12 6EP1 334-1SH01 Approx. 87 % Approx. 36 W Approx. 87 % Approx. 34 W Approx. 89 % Approx. 30 W Approx. 85 % Approx. 42 W 0.3 % Vout 0.3 % Vout 0.3 % Vout 0.3 % Vout 5 % Vout 2.5 % Vout 0.6 % Vout 1.5 % Vout typ. 0.2 ms typ. 0.2 ms < 5 ms < 5 ms < 5 ms (typ. 0.1 ms) < 5 ms (typ. 0.2 ms) < 20 ms (typ. 10 ms) < 20 ms (typ. 10 ms) Yes, acc. to EN 60950 Additional control loop, shutdown at approx. 33 V, automatic restart 11 to 13 A Yes, acc. to EN 60950 typ. 9 to 11 A Additional control loop, shutdown at approx. 30 V, automatic restart 11 to 12 A Choice of automatic restart or latching shutdown Electronic shutdown, automatic restart Electronic shutdown, automatic restart Stabilized current characteristic down to 0 V < 21 A Red LED for overtemperature switch-off < 10 A - < 10 A - < 14 A - Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA (typ. 0.9 mA) Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.5 mA) Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.27 mA) Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA Yes Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E197259 Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 IP65 Yes, Class I Div. 2, A, B, C, D, T4 in the S7-300 system IP20 IP20 IP20 EN 55011 Class A EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 -25 to +55 C (power derating above +40 C) 0 to +60 C with natural convection 0 to +60 C with natural convection 0 to +60 C with natural convection -40 to +70 C -40 to +85 C -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Screw-type terminals 0.5 to 2.5 mm2 (PG11 screwed gland) Screw terminals, or connection via expansion interface on the backplane bus of the ET 200X Screw terminals, or connection via expansion interface on the backplane bus of the ET 200X One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 4 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 4 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 140 x 270 x 126 120 x 125 x 120 1) 120 x 125 x 135 2) 1.1 kg Snap-mounting on S7 rail 1) Snap-mounting on DIN rail EN 50022-35x15 2) 160 x 130 x 60 200 x 125 x 135 0.72 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 1.8 kg Snap-mounting on DIN rail EN 50022-35x15 or on S7 rail Mounting adapter for DIN rail and PS-CPU connecting comb Mounting bracket - 1.7 kg Wall mounting, any mounting position IP65 connector seal 5 11 to 13 A 1) Order No. 6ES7307-1KA01-0AA0. 2) Order No. 6EP1334-1SL12. Siemens KT10.1 * 2004 5/5 SITOP power * Standard 24 V Single-phase and two-phase Notes 5 5/6 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase 6/2 6/3 6/3 6 Output currents 20 A and 40 A SITOP modular The proven type The two-phase version Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output currents 20 A and 40 A Overview SITOP modular Application SITOP modular The modular power supply units with single-phase and twophase inputs for global use in many different fields of application; expansion of functions possible using add-on modules. 6 Technical specifications Power supply, type 20 A 40 A Order No. 6EP1 336-3BA00 6EP1 337-3BA00 Input Rated voltage Vin rated Single/two-phase AC 120/230 V AC Settable using wire jumper on device 85 to 132/176 to 264 V Single/two-phase AC 120/230 V AC Settable using wire jumper on device 85 to 132/176 to 264 V Voltage range Overvoltage strength 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 20 ms at Vin = 230 V 50/60 Hz; 47 to 63 Hz 7.7/3.5 A < 60 A > 20 ms at Vin = 230 V 50/60 Hz; 47 to 63 Hz 15/8 A < 125 A I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 9.9 A2s Yes 10 A Char. C (2-pole coupled with 2-phase operation) or motor circuit-breaker 3RV1421-... < 26 A2s Yes 20 A Char. C (2-pole coupled with 2-phase operation) or motor circuit-breaker 3RV1421-... Output Rated voltage Vout rated Total tolerance * Stat. mains compensation * Stat. load compensation Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.1 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.1 % Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) Setting range Status display Power ON/OFF behavior < 100 mVpp (typ. 30 mVpp) < 100 mVpp (typ. 60 mVpp) < 200 mVpp (typ. 60 mVpp) 24 to 28.8 V (max. 480 W) Green LED for 24 V O.K. Overshoot of Vout approx. 3 % < 200 mVpp (typ. 120 mVpp) 24 to 28.8 V (max. 960 W) Green LED for 24 V O.K. Overshoot of Vout approx. 3 % Starting delay/voltage rise Rated current Iout rated Current range * Up to +45 C * Up to +60 C < 0.1 s/< 50 ms 20 A < 0.1 s/< 50 ms 40 A 0 to 20 A 0 to 20 A 0 to 40 A 1) 0 to 40 A 1) Approx. 23 A constant current typ. 60 A for 25 ms Yes, 2 (selectable current characteristic) Approx. 46 A constant current typ. 120 A for 25 ms Yes, 2 (selectable current characteristic) Dyn. V/I with * Starting on short circuit * Short-circuit in operation Parallel connection for increased output Continued on page 6/4. 1) Derating in 120 V operation necessary. 6/2 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output currents 20 A and 40 A The proven type The two-phase version The tried and tested power supply unit with selectable input voltage range for supplying all standard applications in automation engineering. The power supply unit with 2-phase wide-range input for widely changing power supply networks (> 550 V) as well as industrial networks in Canada and the USA. 20 A 20 A 6EP1 336-2BA00 6EP1 536-2AA00 Single-phase AC 120/230 V AC Settable using wire jumper Two-phase AC 500 to 600 V 2 AC wide-range input 93 to 132/187 to 264 V AC 420 to 682 V 2 AC 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms > 10 ms at Vin = 93/187 V 50/60 Hz, 47 to 63 Hz 8.0/3.3 A < 81 A 6/30 ms at Vin = 420/600 V 50/60 Hz; 47 to 63 Hz 1.82 A (at 420 V) typ. 25 A < 8 A 2s T 10 A (not accessible) Circuit-breaker from 16 A Characteristic C < 1.0 A2s none Required: 2-pole coupled circuit-breaker Char. C max. 10 A or motor circuit-breaker 3RV1021-1DA10, setting 3 A Stabilized, floating direct voltage 24 V DC 3% Stabilized, floating direct voltage 24 V DC 3% < 150 mVpp < 150 mVpp < 240 mVpp 22.8 to 26.4 V 1) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 240 mVpp 22.8 to 28.8 V 2) Green LED for 24 V O.K. Small overshoot of Vout (< 2 V for max. 500 ms) < 3 s/typ. 80 ms 20 A 20 A 0 to 20 A 0 to 20 A (55 C) 0 to 20 A 0 to 20 A Approx. 20 A constant current Approx. 20 A constant current Yes, 2 1) Approx. 25 A constant current Approx. 28 A constant current Yes, 2 2) 6 Continued on page 6/5. 1) Only permissible with ambient temperature from 0 to 45 C. 2) Only permissible with ambient temperature from 0 to 50 C. Siemens KT10.1 * 2004 6/3 SITOP power * Standard 24 V Single-phase and two-phase Output currents 20 A and 40 A Power supply, type 20 A 40 A Order No. 6EP1 336-3BA00 6EP1 337-3BA00 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 89 % Approx. 59 W Approx. 88 % Approx. 131 W < 1 % Vout < 1 % Vout Approx. 2 % Vout Approx. 2 % Vout Settling time * Load step from 50 to 100 % * Load step from 100 to 50 % < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms) Protection and monitoring Output overvoltage protection Current limitation < 35 V typ. 23 A < 35 V typ. 46 A Choice of stabilized current characteristic approx. 23 A or latching shutdown Approx. 23 A Yellow LED for "overload", red LED for "latching shutdown" Choice of stabilized current characteristic approx. 46 A or latching shutdown Approx. 46 A Yellow LED for "overload", red LED for "latching shutdown" Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.4 mA) Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.4 mA) TUV test CE marking UL/cUL (CSA) approval Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E197259 Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E197259 FM approval Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-6-2 0 to +60 C with natural convection 0 to +60 C with natural convection -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.2 to 4 mm2 singlecore/finely stranded 2 screw-type terminals for 0.5 to 4 mm2 2 screw-type terminals for 0.5 to 4 mm2 One screw-type terminal each for 0.2 to 4 mm2 singlecore/finely stranded 2 screw-type terminals for 0.5 to 10 mm2 2 screw-type terminals for 0.5 to 10 mm2 Dimensions (W x H x D) in mm Weight approx. Mounting 160 x 125 x 125 2.2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 240 x 125 x 125 2.9 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Accessories Buffer module (6EP1961-3BA00) Signalling module (6EP19613BA10) Redundancy module (6EP19613BA20) Buffer module (6EP1961-3BA00) Signalling module (6EP19613BA10) Redundancy module (6EP19613BA20) Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 50/100/50 %) Short-circuit protection 6 RMS sustained short-circuit current Overload/short-circuit indicator Safety Galvanic isolation primary/secondary Protective class Discharge current Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections * Mains input L, N, PE * Output L+ * Output M 6/4 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Single-phase and two-phase Output currents 20 A and 40 A 20 A 20 A 6EP1 336-2BA00 6EP1 536-2AA00 Approx. 87 % Approx. 72 W Approx. 89 % Approx. 60 W Approx. 0.3 % Vout < 1 % Vout 1 % Vout -4 %, +2 % Vout Vout not outside tolerance Vout not outside tolerance < 3 ms < 3 ms Yes, acc. to EN 60950 typ. 22 A Yes, acc. to EN 60950 typ. 21 to 26 A Stabilized current characteristic down to 0 V Stabilized current characteristic approx. 28 A < 22 A - Approx. 28 A - Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA Yes, SELV output voltage Vout acc. to EN 60950 Class I < 0.78 mA (550 V/60 Hz) Yes Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) IP20 IP20 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55011 Class A EN 61000-6-2 0 to +55 C with natural convection 0 to +60 C with natural convection -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.33 to 10 mm2 2 screw-type terminals for 0.33 to 10 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.33 to 10 mm2 2 screw-type terminals for 0.33 to 10 mm2 280 x 125 x 92 2.4 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 280 x 180 x 92 3.3 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Mounting bracket 90 (6EP1971-2BA00) Mounting bracket 90 (6EP1971-2BA00) 6 Siemens KT10.1 * 2004 6/5 SITOP power * Standard 24 V Single-phase and two-phase Notes 6 6/6 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Three-phase 7/2 7/2 7/3 7/6 7/6 7/7 7 Output currents 5 A to 40 A SITOP modular 7 5 A and 10 A 7 20 A and 40 A The proven types 7 10 A and 20 A 7 30 A and 40 A Siemens KT10.1 * 2004 SITOP power * Standard 24 V Three-phase Output currents 5 A to 40 A Overview SITOP modular Application SITOP modular The modular power supply units with wide-range input for twophase connection to three-phase power supply networks; for global use in many different fields of application; expansion of functions possible using add-on modules. Technical specifications 7 Power supply, type 5A 10 A Order No. 6EP1 333-3BA00 6EP1 334-3BA00 Input Rated voltage Vin rated Two-phase AC 120/230 to 500 V AC Settable via selector switch on device 85 to 132/176 to 550 V AC Two-phase AC 120/230 to 500 V AC Settable via selector switch on device 85 to 132/176 to 550 V AC Voltage range Overvoltage strength 1300 Vpeak, 1.3 ms 1300 Vpeak, 1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 25 ms at Vin = 120/230 V 50/60 Hz; 47 to 63 Hz 2.2/1.2 to 0.61 A < 35 A > 25 ms at Vin = 120/230 V 50/60 Hz; 47 to 63 Hz 4.4/2.4 to 1.1 A < 35 A I2t Integrated line-side fuse Required fuse protection in mains supply line < 1.7 A2s T 3, 15 A Circuit-breaker 6 A (10 A) Characteristic C (B), 2-pole coupled, or motor circuit-breaker 3RV1021-... < 4.0 A2s T 6.3 A Circuit-breaker 6 A (10 A) Characteristic C (B), 2-pole coupled, or motor circuit-breaker 3RV1021-... Output Rated voltage Vout rated Total tolerance * Stat. mains compensation * Stat. load compensation Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.1 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.1 % Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) Setting range Status display Power ON/OFF behavior < 50 mVpp (typ. 10 mVpp) < 50 mVpp (typ. 10 mVpp) < 200 mVpp (typ. 20 mVpp) 24 to 28.8 V (max. 120 W) Green LED for 24 V O.K. Overshoot of Vout approx. 3 % < 200 mVpp (typ. 20 mVpp) 24 to 28.8 V (max. 240 W) Green LED for 24 V O.K. Overshoot of Vout approx. 3 % Starting delay/voltage rise Rated current Iout rated Current range * Up to +45 C * Up to +60 C < 1 s/< 50 ms 5A < 1 s/< 50 ms 10 A 0 to 5 A 0 to 5 A 0 to 10 A 0 to 10 A Dyn. V/I with * Starting on short circuit * Short-circuit in operation Parallel connection for increased output Approx. 5.5 A constant current typ. 15 A for 25 ms Yes, 2 (selectable current characteristic) Approx. 12 A constant current typ. 30 A for 25 ms Yes, 2 (selectable current characteristic) Continued on page 7/4. 7/2 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Three-phase Output currents 5 A to 40 A SITOP modular SITOP modular The modular power supply units with three-phase wide-range input for global use in many different fields of application; expansion of functions possible using add-on modules. 20 A 40 A 6EP1 436-3BA00 6EP1 437-3BA00 Three-phase AC 400 to 500 V 3 AC wide-range input Three-phase AC 400 to 500 V 3 AC wide-range input 320 to 550 V (startup from Vin > 340) 320 to 550 V (startup from Vin > 340) 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms > 6 ms at Vin = 400 V 50/60 Hz; 47 to 63 Hz 1.1 A (Vin = 400 V) < 35 A > 6 ms at Vin = 400 V 50/60 Hz; 47 to 63 Hz 2.2 A (Vin = 400 V) < 70 A < 0.7 A2s None 3-pole coupled circuit-breaker 6 to 16 A Char. C or motor circuit-breaker 3RV1021-1DA10, setting 3 A < 2.8 A2s None 3-pole coupled circuit-breaker 10 to 16 A Char. C or motor circuit-breaker 3RV1021-1DA10, setting 3 A Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % < 100 mVpp < 100 mVpp < 200 mVpp 24 to 28.8 V (max. 480 W) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 200 mVpp 24 to 28.8 V (max. 960 W) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 2.5 s/< 500 ms 20 A < 2.5 s/< 500 ms 40 A 0 to 20 A 0 to 20 A 0 to 40 A 0 to 40 A Approx. 23 A constant current typ. 60 A for 25 ms Yes, 2 (selectable current characteristic) Approx. 46 A constant current typ. 120 A for 25 ms Yes, 2 (selectable current characteristic) 7 Continued on page 7/5. Siemens KT10.1 * 2004 7/3 SITOP power * Standard 24 V Three-phase Output currents 5 A to 40 A Power supply, type 5A 10 A Order No. 6EP1 333-3BA00 6EP1 334-3BA00 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 87 % Approx. 18 W Approx. 87 % Approx. 36 W Approx. 0.1 % Approx. 0.1 % Approx. +3 % Vout Approx. +3% Vout Settling time * Load step from 50 to 100 % * Load step from 100 to 50 % < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms) < 5 ms (typ. 2 ms) Protection and monitoring Output overvoltage protection Current limitation < 35 V typ. 5.5 A < 35 V typ. 12 A Choice of stabilized current characteristic approx. 5.5 A or latching shutdown Approx. 5.5 A Yellow LED for "overload", red LED for "latching shutdown" Choice of stabilized current characteristic approx. 12 A or latching shutdown Approx. 12 A Yellow LED for "overload", red LED for "latching shutdown" Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.25 mA) Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA (typ. 0.32 mA) TUV test CE marking UL/cUL (CSA) approval Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E197259 Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E197259 FM approval Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 0 to +60 C with natural convection 0 to +60 C with natural convection -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.2 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals for 0.2 to 2.5 mm2 2 screw-type terminals for 0.2 to 2.5 mm2 One screw-type terminal each for 0.2 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals for 0.2 to 2.5 mm2 2 screw-type terminals for 0.2 to 2.5 mm2 Dimensions (W x H x D) in mm Weight approx. Mounting 70 x 125 x 125 1.2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 90 x 125 x 125 1.4 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Accessories Buffer module (6EP1961-3BA00) Signalling module (6EP1961-3BA10) Redundancy module (6EP1961-3BA20) Buffer module (6EP1961-3BA00) Signalling module (6EP1961-3BA10) Redundancy module (6EP1961-3BA20) Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 50/100/50 %) Short-circuit protection RMS sustained short-circuit current Overload/short-circuit indicator 7 Safety Galvanic isolation primary/secondary Protective class Discharge current Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections * Mains input L1, L2, L3, PE * Output L+ * Output M 7/4 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Three-phase Output currents 5 A to 40 A 20 A 40 A 6EP1 436-3BA00 6EP1 437-3BA00 Approx. 90 % Approx. 53 W Approx. 90 % Approx. 106 W < 1 % Vout < 1 % Vout Approx. 2 % Vout Approx. 2 % Vout < 10 ms (typ. 4 ms) < 10 ms (typ. 4 ms) < 10 ms (typ. 4 ms) < 10 ms (typ. 4 ms) < 35 V typ. 23 A < 35 V typ. 46 A Choice of stabilized current characteristic approx. 23 A or latching shutdown Approx. 23 A Yellow LED for "overload", red LED for "latching shutdown" Choice of stabilized current characteristic approx. 46 A or latching shutdown Approx. 46 A Yellow LED for "overload", red LED for "latching shutdown" Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA Yes Yes Yes, UL listed (UL 508) File E197259, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, UL listed (UL 508) File E197259, CSA (CSA 22.2 No. 14-95) IP20 IP20 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 0 to +60 C with natural convection 0 to +60 C with natural convection -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.2 to 4 mm2 singlecore/finely stranded 2 screw-type terminals for 0.33 to 4 mm2 2 screw-type terminals for 0.33 to 4 mm2 One screw-type terminal each for 0.2 to 4 mm2 singlecore/finely stranded 2 screw-type terminals for 0.33 to 10 mm2 2 screw-type terminals for 0.33 to 10 mm2 160 x 125 x 125 2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 240 x 125 x 125 3.2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Buffer module (6EP1961-3BA00) Signalling module (6EP1961-3BA10) Redundancy module (6EP1961-3BA20) Buffer module (6EP1961-3BA00) Signalling module (6EP1961-3BA10) Redundancy module (6EP1961-3BA20) 7 Siemens KT10.1 * 2004 7/5 SITOP power * Standard 24 V Three-phase Output currents 10 A to 40 A Overview The proven types Application The tried and tested power supply units with three-phase widerange input for supplying all standard applications in automation engineering. Technical specifications 7 Power supply, type 10 A 20 A Order No. 6EP1 434-2BA00 6EP1 436-2BA00 Input Rated voltage Vin rated Three-phase AC 400 to 500 V 3 AC wide-range input 360 to 550 V 3 AC (340 to 360 V for max. 2 s or at max. 0.9 x Iout rated) Three-phase AC 400 to 500 V 3 AC wide-range input 360 to 550 V 3 AC (340 to 360 V for max. 2 s or at max. 0.9 x Iout rated) Overvoltage strength 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 6 ms at Vin = 360 V 50/60 Hz; 47 to 63 Hz 0.65 A (at 400 V) < 25 A > 3 ms at Vin = 360 V 50/60 Hz; 47 to 63 Hz 1.2 A (at 400 V) < 25 A I2t Integrated line-side fuse Required fuse protection in mains supply line < 1.0 A2s none 3-pole coupled circuit-breaker Char. C up to 25 A (recommendation: 6 A) or motor circuitbreaker 3RV1021-1DA10, setting 3 A < 1.0 A2s none 3-pole coupled circuit-breaker Char. C up to 25 A (recommendation: 6 A) or motor circuitbreaker 3RV1021-1DA10, setting 3 A Output Rated voltage Vout rated Total tolerance * Stat. mains compensation * Stat. load compensation Stabilized, floating direct voltage 24 V DC 3% Stabilized, floating direct voltage 24 V DC 3% Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) Setting range Status display Power ON/OFF behavior < 150 mVpp (typ. 60 mVpp) < 150 mVpp (typ. 60 mVpp) < 240 mVpp (typ. 120 mVpp) 22.8 to 26.4 V 1) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 240 mVpp (typ. 120 mVpp) 22.8 to 26.4 V 1) Green LED for 24 V O.K. No overshoot of Vout (soft start) Starting delay/voltage rise Rated current Iout rated Current range * Up to +45 C * Up to +55 C < 3 s/typ. 40 ms 10 A < 3 s/typ. 40 ms 20 A 0 to 10 A 0 to 10 A 0 to 20 A 0 to 20 A Constant current approx. 18 A Constant current approx. 18 A Yes, 2 1) Constant current approx. 30 A Constant current approx. 30 A Yes, 2 1) Voltage range Dyn. V/I with * Starting on short circuit * Short-circuit in operation Parallel connection for increased output Continued on page 7/8. 1) Only permissible with ambient temperature from 0 C to 45 C. 7/6 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Three-phase Output currents 10 A to 40 A The proven types The tried and tested power supply units with three-phase widerange input for supplying all standard applications in automation engineering. 30 A 40 A 6EP1 437-2BA00 6EP1 437-2BA10 Three-phase AC 400 to 500 V 3 AC wide-range input 360 to 550 V 3 AC (340 to 360 V for max. 2 s or at max. 0.9 x Iout rated) Three-phase AC 400 to 500 V 3 AC wide-range input 360 to 550 V 3 AC (340 to 360 V for max. 2 s or at max. 0.9 x Iout rated) 2.3 x Vin rated, 1.3 ms 2.3 x Vin rated, 1.3 ms > 4.5 ms at Vin = 360 V 50/60 Hz; 47 to 63 Hz 1.4 A (at 400 V) < 25 A > 3 ms at Vin = 360 V 50/60 Hz; 47 to 63 Hz 1.9 A (at 400 V) < 25 A < 1.0 A2s none 3-pole coupled circuit-breaker Char. C up to 25 A (recommendation: 6 A) or motor circuitbreaker 3RV1021-1DA10, setting 3 A < 1.0 A2s none 3-pole coupled circuit-breaker Char. C up to 25 A (recommendation: 6 A) or motor circuitbreaker 3RV1021-1DA10, setting 3 A Stabilized, floating direct voltage 24 V DC 3% Stabilized, floating direct voltage 24 V DC 3% < 150 mVpp (typ. 50 mVpp) < 150 mVpp (typ. 50 mVpp) < 240 mVpp (typ. 200 mVpp) 22.8 to 26.4 V 1) Green LED for 24 V O.K. Small overshoot of Vout (< 2 V for max. 500 ms) < 240 mVpp (typ. 200 mVpp) 22.8 to 26.4 V 1) Green LED for 24 V O.K. Small overshoot of Vout (< 2 V for max. 500 ms) < 3 ms/typ. 40 ms 30 A < 3 ms/typ. 40 ms 40 A 0 to 30 A 0 to 30 A 0 to 40 A 0 to 40 A Approx. 60 A for 600 ms Approx. 60 A for 600 ms Yes, 2 1) Approx. 70 A for 600 ms Approx. 70 A for 600 ms Yes, 2 1) 7 Continued on page 7/9. Siemens KT10.1 * 2004 7/7 SITOP power * Standard 24 V Three-phase Output currents 10 A to 40 A Power supply, type 10 A 20 A Order No. 6EP1 434-2BA00 6EP1 436-2BA00 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 89 % Approx. 30 W Approx. 89 % Approx. 59 W < 1 % Vout < 1 % Vout 2 % Vout 2 % Vout Settling time * Load step from 50 to 100 % * Load step from 100 to 50 % < 2 ms < 2 ms < 2 ms < 2 ms Protection and monitoring Output overvoltage protection Current limitation Yes, acc. to EN 60950 typ. 10.5 to 13 A Yes, acc. to EN 60950 typ. 21 to 26 A Short-circuit protection Stabilized current characteristic down to 0 V Stabilized current characteristic down to 0 V RMS sustained short-circuit current Overload/short-circuit indicator < 20 A - < 30 A - Safety Galvanic isolation primary/secondary Protective class Discharge current Yes, SELV output voltage Vout acc. to EN 60950 Class I < 0.35 mA (550 V/60 Hz) Yes, SELV output voltage Vout acc. to EN 60950 Class I < 0.35 mA (550 V/60 Hz) TUV test CE marking UL/cUL (CSA) approval Yes; CB scheme Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 Yes; CB scheme Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 FM approval Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 0 to +55 C with natural convection 0 to +55 C with natural convection -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.33 to 10 mm2 2 screw-type terminals for 0.33 to 10 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.33 to 10 mm2 2 screw-type terminals for 0.33 to 10 mm2 Dimensions (W x H x D) in mm Weight approx. Mounting 280 x 125 x 92 2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 280 x 125 x 92 2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Accessories Mounting bracket 90 (6EP1971-2BA00) Mounting bracket 90 (6EP1971-2BA00) Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 50/100/50 %) 7 Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections * Mains input L1, L2, L3, PE * Output L+ * Output M 7/8 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Three-phase Output currents 10 A to 40 A 30 A 40 A 6EP1 437-2BA00 6EP1 437-2BA10 Approx. 90 % Approx. 80 W Approx. 90 % Approx. 107 W < 1 % Vout < 1 % Vout -4 %, +2 % Vout -4 %, +2 % Vout < 3 ms < 3 ms < 3 ms < 3 ms Yes, acc. to EN 60950 typ. 31.5 to 39 A Yes, acc. to EN 60950 typ. 42 to 52 A Electronic shutdown, automatic restart Electronic shutdown, automatic restart < 48 A - < 62 A - Yes, SELV output voltage Vout acc. to EN 60950 Class I < 0.78 mA (550 V/60 Hz) Yes, SELV output voltage Vout acc. to EN 60950 Class I < 0.78 mA (550 V/60 Hz) Yes; CB scheme Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 Yes; CB scheme Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 IP20 IP20 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 0 to +55 C with natural convection 0 to +55 C with natural convection -25 to +85 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.33 to 10 mm2 2 screw-type terminals for 0.33 to 10 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 1 screw-type terminal for 0.33 to 10 mm2 2 screw-type terminals for 0.33 to 10 mm2 280 x 180 x 92 3.6 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 280 x 180 x 92 3.6 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Mounting bracket 90 (6EP1971-2BA00) Mounting bracket 90 (6EP1971-2BA00) 7 Siemens KT10.1 * 2004 7/9 SITOP power * Standard 24 V Three-phase Notes 7 7/10 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Additional components 8/2 8/2 8/2 8/4 8/6 8/7 8/7 8/7 8 SITOP modular signalling module SITOP modular buffer module SITOP modular redundancy module SITOP select diagnosis module Mounting bracket 90 Mounting adapter for S7 rail and PS-CPU connecting comb IP65 connector seals Circular input connectors and AS-Interface coupling module PG Siemens KT10.1 * 2004 SITOP power * Standard 24 V Additional components Overview Application 8 SITOP modular signalling module SITOP modular buffer module SITOP modular redundancy module Using the signalling module in combination with a stabilized SITOP modular power supply unit, signals can be provided on the operating status of the power supply unit, and remote switching ON/OFF of the unit is possible; automatic contacting with the power supply unit. With brief interruptions in the power supply, the buffer module in combination with a stabilized SITOP modular power supply unit can buffer the load current without an interruption. The buffer module is wired in parallel with the output of the power supply unit. The redundancy module serves to decouple two stabilized SITOP modular power supplies in parallel mode. If one power supply fails, the 24 V is safely retained. 6EP1 961-3BA10 6EP1 961-3BA00 6EP1 961-3BA20 - Stabilized, floating direct voltage 24 V DC 24 to 28.8 V DC Stabilized, floating direct voltage 24 V DC 24 to 28.8 V DC - - Vin - approx. 1 V 40 A Vin - approx. 0.5 V 20 A (maximum total current 40 A) - Technical specifications Order No. Input/output Rated input voltage Vin rated Input voltage range Control input Rated output voltage Vout rated Rated current Iout rated Non-isolated input for remote ON/OFF switching of the power supply unit - Mains buffering - Buffer time, max. Parallel connection for increased output - 100 ms at 40 A up to 800 ms at 5 A load current 3s Yes, 2 Protection and monitoring Static current limitation Short-circuit protection - typ. 40 A Electronic - Displays/messages Status display - Green LED for supply voltage > 20.5 V - Green LED for "Power supply 1 and Power supply 2 OK" Floating relay contact (changeover contact, rating 6 A/240 V AC) for "Power supply 1 and Power supply 2 OK", switching threshold adjustable from 20 to 25 V Signals 8/2 Floating relay contacts (changeover contacts, rating 6 A/240 V AC) for "Output voltage OK" and "Power supply availability OK" Siemens KT10.1 * 2004 - SITOP power * Standard 24 V Additional components Technical specifications (continued) Order No. 6EP1 961-3BA10 6EP1 961-3BA00 6EP1 961-3BA20 Yes, SELV acc. to EN 60950 (relay contacts) Class I Yes, SELV acc. to EN 60950 Yes, SELV acc. to EN 60950 (relay contact) Class I TUV test CE marking UL/cUL (CSA) approval Yes Yes Yes, UL listed (UL 508) File E197259, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, UL listed (UL 508) File E197259, CSA (CSA 22.2 No. 14-95) Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91) FM approval Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 IP20 EMC Interference emission Interference immunity EN 55022 Class B EN 61000-6-2 EN 55022 Class B EN 61000-6-2 EN 55022 Class B EN 61000-6-2 0 to +60 C with natural convection -25 to +85 C 0 to +60 C with natural convection -25 to +85 C 0 to +60 C with natural convection -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Screw-type terminals for 0.14 to 2.5 mm2 single-core/finely stranded One screw-type terminal each for + and - for 0.5 to 10 mm2 single-core/finely stranded 26 x 125 x 116 0.15 kg Can be directly snapped onto the side of the basic unit 70 x 125 x 125 1.2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Input, output and ground: one screw-type terminal each for 0.33 to 10 mm2, singlecore/finely stranded; relay contact: one screw-type terminal each for 0.5 to 2.5 mm2, single-core/finely stranded 70 x 125 x 125 1.0 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Safety Galvanic isolation Protective class Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections Dimensions (W x H x D) in mm Weight approx. Mounting Class I Siemens KT10.1 * 2004 8/3 8 SITOP power * Standard 24 V Additional components Overview SITOP select Application The diagnosis module is used together with 24 V power supply units to divide the load current between several branch circuits and to monitor the individual currents. Faults in the individual circuits resulting from an overload or short-circuit are detected and switched off selectively, and other load current paths therefore remain unaffected by the fault. This results in rapid fault diagnostics, and downtimes are minimized. Technical specifications 8 Type Module 4 x 10 A Order No. 6EP1 961-2BA00 Input Rated voltage Vin rated Voltage range Overvoltage strength DC voltage 24 V DC 22 to 30 V 35 V; 100 ms Output Rated voltage Vout rated Total tolerance/ residual ripple Number of output channels Rated current Iout rated up to +60 C Setting range Parallel connection of several channels DC voltage Vout - 0.5 V Corresponding to the input voltage 4 10 A per channel 2 to 10 A per channel Not permissible Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 97 % Approx. 30 W Switch-off characteristic per channel Overcurrent Current limitation Immediate switch-off Reset Iout = 1.0 to 1.3 x set value, switch-off after approx. 5 s Iout = 1.35 x set value, switch-off after approx. 50 to 100 ms Iout > set value and Vin < 20 V Using keys on module Protection and monitoring Line protection Status displays Signaling contact Safety Protective class Degree of protection (EN 60529) TUV test CE marking UL/cUL (CSA) approval EMC Interference emission Interference immunity Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating 8/4 Siemens KT10.1 * 2004 Electronic; additionally possible via accessible FK2 blade-type fuse (equipped when delivered with 15 A fuse) per channel Two-color LED per channel, green for output switched through, red for output switched off Common signal contact (NO contact) Class III IP20 Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E197259; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 EN 55022 Class B EN 61000-6-2 0 to +60 C with natural convection -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation SITOP power * Standard 24 V Additional components Technical specifications (continued) Type Module 4 x 10 A Order No. 6EP1 961-2BA00 Mechanical specifications Connections * Input +24 * Input 0 V * Outputs 1 to 4 * Signalling contact 2 screw-type terminals for 0.33 to 10 mm2 2 screw-type terminals for 0.22 to 4 mm2 1 screw-type terminal per channel for 0.22 to 4 mm2 2 screw-type terminals for 0.22 to 4 mm2 Dimensions (W x H x D) in mm Weight Mounting 72 x 90 x 90 0.4 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Characteristic curves G_KT01_en_00062 100.0 Release time s 10.0 5.0 s 1.0 0.10 s 0.1 0.0 0 20 40 60 80 100 8 120 % 140 Load current rated Switch-off characteristic Schematics Power supply, e.g. SITOP power + ~ = 24 V n SITOP + 24 V select Reset 13 Floating signalling contact 14 0V 1 2 3 4 Load 1 Load 2 Load 3 Load 4 G_KT01_EN_00063a Control logics Basic circuit Siemens KT10.1 * 2004 8/5 SITOP power * Standard 24 V Additional components Overview Mounting bracket Application Combination of a SITOP power supply unit with a 90 mounting bracket results in a minimum surface requirement on the rear panel of the switchgear cabinet (the width of the power supply unit becomes the depth, the depth becomes the width). The mounting bracket is suitable for switchgear cabinets with a depth of 240 mm or 320 mm or more. Technical specifications 8 Mounting bracket For depth 240 mm For depth 320 mm Order No. 6EP1 971-1AA01 6EP1 971-2BA00 Dimensions (W x H x D) in mm 50 x 159 x 236 100 x 150 x 320 Sheet plate thickness 2 mm 1.5 mm Connected mounting rail DIN rail EN 50022-35x7.5 DIN rail EN 50022-35x15 Weight approx. 0.9 kg 0.9 kg Mounting Can be screwed on level surface (keyhole mounting with M5 screws, drill hole distance 147.5 mm height) Can be screwed on level surface (keyhole mounting with M6 screws, drill hole distance 90 mm height, 50 mm to the side) Supplied accessories Two M5 combi screws and two M5 self-tapping screws Four M6 combi screws Suitable for SITOP 24 V/3.5 A (6EP1 332-1SH31) SITOP 24 V/5 A (6EP1 333-1AL12) SITOP 24 V/10 A (6EP1 334-1AL12) SITOP DC UPS module 40 A (6EP1 931-2FC01) SITOP 24 V/10 A (6EP1 434-2BA00) SITOP 24 V/20 A (6EP1 336-2BA00, 6EP1 335-3BA00, 6EP1 436-2BA00, 6EP1 436-3BA00, 6EP1 457-3BA00, 6EP1 536-2AA00) SITOP 24 V/30 A (6EP1 437-2BA00) SITOP 24 V/40 A (6EP1 437-2BA10, 6EP1 337-3BA00, 6EP1 437-3BA00) 8/6 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Additional components Mounting adapter for S7 rail and PS-CPU connecting comb The single-phase SITOP power supply units 24 V/2 A (6ES7 307-1BA00-0AA0, 6ES7 305-1BA80-0AA0 ), 24 V/5 A (6ES7 307-1EA000AA0, 6ES7 307-1EA80-0AA0) and 24 V/10 A (6ES7 307-1KA01-0AA0) are special mechanical versions for SIMATIC S7-300. They can be mounted on an S7 rail, and the connection to the new CPUs or the compact CPUs of the S7-300 can be established without problem using a supplied connecting comb. Power supply units of same design without connecting comb, but with a supplied mounting adapter for DIN rail EN 50022-35x15, are available with the Order Nos. 6EP1 331-1SL11 (24 V/2 A), 6EP1 333-1SL11 (24 V/5 A) and 6EP1 334-1SL12 (24 V/10 A). A connecting comb for older CPUs with product phase-out since 2003 as well as the mounting adapter are available as individual accessories. Selection and Ordering Data PS-CPU connecting comb (spare part for CPUs 313, 314, 315, 315/316/318-2 DP, IM153) 6ES7 390-7BA00-0AA0 Mounting adapter for DIN rail EN 50022-35x15 6ES7 390-6BA00-0AA0 IP65 connector seals The single-phase SITOP power supply unit 24 V/10 A in IP65 degree of protection (6EP1 334-2CA00) has a design and functionality which are optimally adapted to the ET 200X distributed I/O system. Thanks to integral plug-in connectors, it can be flush-mounted with the modules without any special wiring overhead. If the power supply unit is operated outside the ET 200X system as a stand-alone power supply unit in IP65 degree of protection, connector seals are required to seal the integral plug-in connectors. Selection and Ordering Data IP65 connector seal for power supply unit 6EP1 334-2CA00 6EP1 971-2CA00 Circular input connectors and AS interface coupling module PG A 6-pole circular connector with socket inset is required for the ASi power supply 30 V/2.4 A in IP65 degree of protection (6EP1 632-1AL01) for connection of the input side. The connection of the ASi power supply to the ASi network is made using the coupling module PG. Selection and Ordering Data 6-pole circular input connector with socket inset 6ES5 760-2CA11 AS interface coupling module PG 3RG9 220-0AA00 Siemens KT10.1 * 2004 8/7 8 SITOP power * Standard 24 V Additional components Notes 8 8/8 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Uninterruptible power supplies 9/2 9/2 9/3 9/11 9/14 9/15 9/16 9/17 9/18 9 DC UPS Overview DC UPS software DC UPS module 6 A and 15 A DC UPS module 40 A Battery module 1.2 Ah Battery module 2.5 Ah Battery module 3.2 Ah Battery module 7 Ah Battery module 12 Ah Siemens KT10.1 * 2004 SITOP power * Standard 24 V Uninterruptible power supplies DC UPS Overview By combining a DC UPS module with at least one 24 V battery module and a SITOP power supply unit, longer power failures can be bridged without any interruption. This combination is used, for example, in machine tool manufacture, in the textile industry, with all types of production lines and filling systems, and in conjunction with 24 V industrial PCs. The negative effects which frequently result from power failures can thus be prevented. For nonstop use in the event of power failures, Siemens offers the uninterruptible power supplies * DC UPS 6 A * DC UPS 15 A * DC UPS 40 A as well as the battery modules * 1.2 Ah * 3.2 Ah * 7 Ah * 12 Ah * 2.5 Ah (high-temperature battery). Selection table for battery modules with power failure buffer times Load current 9 Battery module 1.2 Ah (6EP1935-6MC01) Battery module 3.2 Ah (6EP1935-6MD11) Battery module 7 Ah (6EP1935-6ME21) Battery module 12 Ah (6EP1935-6MF01) Battery module 2.5 Ah (6EP1935-6MD31) 1A 30 min 2.5 h 6h 10 h 2h 2A 11 min 45 min 2.5 h 4h 45 min 4A 2 min 20 min 45 min 2.5 h 20 min 6A 1 min 10 min 30 min 1h 13 min 8A - 4 min 20 min 40 min 9 min 10 A - 1.5 min 15 min 30 min 7 min 12 A - 1 min 10 min 25 min 5.5 min 14 A - 50 s 8 min 20 min 4.5 min 16 A - 40 s 6 min 15 min 4 min 20 A - - 2 min 11 min - Note: * The power failure buffer times are based on the discharge period of the completely charged battery module down to a battery voltage of 21 V; ambient temperature 25 C. * With the DC UPS 40 A module, high electronically limited peak currents (120 A for approx. 12 ms, up to 40 A for several minutes depending on the battery capacity) are automatically delivered in the event of increased load current requirements (e.g. when switching on incandescent lamps, contactors with DC autotransformer winding, DC motors, DC/DC converters, electronic modules with high input capacitance). To achieve this, at least two battery modules of 7 Ah or more must be connected in parallel. * Following a power failure, the battery module is automatically disconnected from the loads electronically and rapidly recharged at 0.2/0.4 A (DC UPS 6 A module), at 0.35/0.7 A (DC UPS 15 A module) or at 2 A (DC UPS 40 A module) (V/I characteristic with 27 V or 27.3 V end-of-charge voltage). DC UPS software The DC UPS 6 A and 15 A modules are optionally available with a serial interface or USB interface. All relevant messages concerning the status of the DC UPS can then be sent to a PC (e.g. SIMATIC PC). The SITOP DC UPS software, with which the signals sent from the DC UPS module can be processed further on the PC, is very easy to use. In monitoring mode, the statuses of the DC UPS module are visualized on the PC. The safe shutdown in the event of a power failure and the automatic restart of the PC are supported. It is also possible to freely define the responses to the various operating states of the DC UPS module, permitting extremely flexible incorporation into many different applications. The software executes under the WinNT 4.0, Win2000 and WinXP operating systems. It is available as freeware on the SITOP Internet site for free downloading. Monitoring and configuration windows of the SITOP UPS software 9/2 Siemens KT10.1 * 2004 SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 6 A and 15 A Overview * Compact design, only 50 mm wide * Simple DIN rail mounting * Absolutely interruption-free buffering of power failures through immediately electronic connection of the batteries as soon as the DC UPS input voltage drops below the value set using DIP switches * High safety and availability through monitoring of operational readiness, battery supply line, battery aging (message "Battery replacement necessary") and battery charge (message "Battery charge >85%") * Support of automatic restart of industrial PCs through selectable switch-off response * Optionally with serial or USB interface. SW tool as download at http://www.siemens.de/sitop executes under WinNT4.0, Win2000 and WinXP. Integration SITOP Power Supply = 24 V DC DC UPS Module 24 V DC Load 9 } Mains or buffer mode Buffer readiness or switching-off of battery } alarm/prewarning and need of battery replacement } Battery charge >85 % Mains, AC or 3 AC Optionally serial interface or USB interface for above signals DC UPS active Battery module G_KT01_EN_00214 parallel switching Siemens KT10.1 * 2004 9/3 SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 6 A and 15 A DC UPS module 6 DC UPS module 15 DC battery X1.7 +Bat DC 2718.5 V DC X1.8 -Bat SITOP power supply power section L+ X1.1 X1.3 L+ X1.5 L+ output Vout Input Vin 24 V DC M X1.4 M X1.6 M X1.2 X2.1 X2.3 X2.2 X2.4 X2.6 X2.5 X2.7 X2.8 control serial X3.1-9 interface only 6EP1931-2DC31 and 6EP1931-2EC31 Bat 24 V DC o.k. alarm readiness charge <85% X2.9 operating state battery X2.10 M On/Off optional USB for 6EP1931-2DC41 and 6EP1931-2EC41 1 o.k. Bat Alarm Ba>85% green yellow red green 9 *1: charging current 0.2 A or 0.4 A for 6EP1931-2DC../0.35 A or 0.7 A for 6EP1931-2EC.. Siemens KT10.1 * 2004 +2 V +1 V +0.5 V +1 V +0.5 V +0.2 V +0.2 V +0.1 V connection threshold +22 V fixed end-of-charge voltage +26.3 V fixed charging current *1 set time/max. time +320 s +160 s + 80 s buffering time + 40 s + 20 s +5 s fixed + 10 s interruption Vout operating state battery On/Off operating elements 9/4 load G_KT01_EN_00226 SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 6 A and 15 A Function The following timing diagrams show the characteristic of the input and output voltages at the terminals of the DC UPS module as well as the signal characteristic of the signals (relays) and the remote signal (interface) as examples. "Long" power failure with DC UPS without serial or USB interface (Fig. 9/1) "Short" power failure with DC UPS without serial or USB interface (Fig. 9/2) Power recovery only following expiry of buffer time tp (t3 after t4): Power recovery prior to expiry of buffer time tp (t3 before t4): If the input voltage at the DC UPS module fails (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage Vout is therefore retained completely without interruption. If the input voltage at the DC UPS module fails (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage Vout is therefore retained completely without interruption. The floating changeover contact "OK/Bat" switches to its deenergized position "Bat". The floating changeover contact "OK/Bat" switches to its deenergized position "Bat". At the time t1, the buffer time tp set on the DIP switches is started automatically. At the time t1, the buffer time tp set on the DIP switches is started automatically. The fact that the DIP switch is set to "Interruption output Vout" has no effect in this example because the input voltage returns at time t3 only after the set buffer time (time t4) has expired. With the selected DIP switch position "Interruption output Vout", the output voltage Vout is automatically interrupted for 5 seconds following expiry of the set buffer time tp (time t4). The battery has already been disconnected because the input voltage has returned at the time t3. If the DIP switch is not set to "Interruption output Vout", there is no interruption in this example because the input voltage has already returned at time t3 prior to expiry of the set buffer time (time t4). Buffer time (time t4) automatically interrupted for 5 s, and battery disconnected from the output at the same time which had not yet been disconnected because the input voltage was missing. Vin Vin Vout Vout ok ok Bat Bat t1 Fig. 9/1 (t4 - t1 = tp) t4 t3 "Long power failure" 9 t1 t3 (t4 - t1 = tp) Fig. 9/2 t4 t5 (t5 - t4 = 5 s) "Short power failure" DC UPS without serial or USB interface (6EP1931-2DC21/ -2EC21) DIP switch settings on device: buffer time tp (from 5 to 635 s with bottom row No. 2 to 7)/ /t = following setting (with bottom row No. 1 to left)/ = with setting interruption Vout (with bottom row No. 8 to left) Legend: Vin: Vout: ok: input voltage at terminals X1.1 - X1.2 output voltage at terminals X1.3 - X1.4 and X1.5 - X1.6 Signal for input voltage Vin OK or above the set battery connection threshold Bat: Signal for battery mode (batteries connected to the output, batteries supply the load) Remote: Signal for remote timer start with signal level = 0 at pin 7 of the 9-pin serial interface (pin 7 is normally the positive power supply of the interface) t1: t2: t3: t4: t5: tp: Input voltage Vin missing or falls below the set connection threshold Buffer time set on the DIP switches is started by a remote timer start (signal level = 0) Input voltage Vin is above the set connection threshold End of set buffer time (output is switched off and/or battery disconnected) Output is connected again 5 sec. after switch-off Buffer time set on the DIP switches (bottom row No. 2 to 7) Siemens KT10.1 * 2004 9/5 SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 6 A and 15 A Function (continued) "Long" power failure with DC UPS with serial or USB interface (Fig. 9/3) "Short" power failure with DC UPS with serial or USB interface (Fig. 9/4) Power recovery only following expiry of buffer time tp (t3 after t4): Power recovery prior to expiry of buffer time tp (t3 before t4): If the input voltage at the DC UPS module fails (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage Vout is therefore retained completely without interruption. If the input voltage at the DC UPS module fails (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage Vout is therefore retained completely without interruption. The floating changeover contact "OK/Bat" switches to its deenergized position "Bat". The floating changeover contact "OK/Bat" switches to its deenergized position "Bat". At the user-selectable time t2, the buffer time tp set on the DIP switches is started by means of the signal "Remote timer start" (signal level = 0 at pin 7 of the 9-pin serial interface). At the user-selectable time t2, the buffer time tp set on the DIP switches is started by means of the signal "Remote timer start" (signal level = 0 at pin 7 of the 9-pin serial interface following previous signal timing according to Instruction Manual). The fact that the DIP switch is set to "Interruption output Vout" has no effect in this example because the input voltage returns at time t3 after the set buffer time (time t4) has expired. Note: Without a remote signal level = 0 with the set duration t = max., there is no interruption in the output voltage here because the set buffer time is not started (or only interrupted if the exhaustive discharge protection disconnects the battery and the input voltage has not returned by then). With the selected DIP switch position "Interruption output Vout", the output voltage Vout is automatically interrupted for 5 seconds following expiry of the set buffer time tp (time t4). The battery has already been disconnected because the input voltage has returned at the time t3. The output voltage interruption of Vout for 5 s permits an automatic restart for many industrial PCs, even if the mains voltage (or the input voltage Vin on the DC UPS module) returns during shutting-down of the PC, as in this example. Note: Without a remote signal level = 0 with setting t = max. duration, there is no interruption in the output voltage here because the set buffer time is not started. 9 Vin Vin Vout Vout ok ok Bat Bat Remote Remote t1 t2 t4 t3 t1 t2 t3 (t4 - t2 = tp) (t4 - t2 = tp) Fig. 9/3 "Long power failure" Fig. 9/4 t4 t5 (t5 - t4 = 5 s) "Short power failure" DC UPS with serial or USB interface (6EP1931-2DC31/-2DC41/-2EC31/-2EC41) DIP switch settings on device: buffer time tp (from 5 to 635 s with bottom row No. 2 to 7)/ /t = max. time (with bottom row No. 1 to right)/interruption Vout (with bottom row No. 8 to left) Legend: Vin: Vout: ok: input voltage at terminals X1.1 - X1.2 output voltage at terminals X1.3 - X1.4 and X1.5 - X1.6 Signal for input voltage Vin OK or above the set battery connection threshold Bat: Signal for battery mode (batteries connected to the output, batteries supply the load) Remote: Signal for remote timer start with signal level = 0 at pin 7 of the 9-pin serial interface (pin 7 is normally the positive power supply of the interface) 9/6 Siemens KT10.1 * 2004 t1: t2: t3: t4: t5: tp: Input voltage Vin missing or falls below the set connection threshold Buffer time set on the DIP switches is started by a remote timer start (signal level = 0) Input voltage Vin is above the set connection threshold End of set buffer time (output is switched off and/or battery disconnected) Output is connected again 5 sec. after switch-off Buffer time set on the DIP switches (bottom row No. 2 to 7) SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 6 A Technical specifications DC UPS module 6 Order No. 6EP1 931-2DC21 6EP1 931-2DC31 (with serial interface) 6EP1 931-2DC41 (with USB interface) Input L+/ M with normal mode Rated voltage Vin rated1) Voltage range Connection threshold for battery Stabilized direct voltage 24 V DC 22 to 29 V DC 22.5 V DC 0.1 V (default setting), adjustable in range from 22 to 25.5 V DC (in intervals of 0.5 V) Rated current Iin rated 6 A + approx. 0.6 A with empty battery Mains buffering Mains buffering or buffer time On/off control circuit Buffer time Output L+/ M with normal mode Rated voltage Vout rated Voltage range Output current Iout Dynamic current with overload Dynamic current with short-circuit Output L+/ M with battery mode Rated voltage Vout rated Voltage range, approx. Output current Iout Dynamic current with overload Dynamic current with short-circuit Output +Bat / -Bat with normal mode End-of-charge voltage V Charging current I Efficiency / power loss At Vout rated, Iout rated approx. With battery operation, approx. Protection and monitoring Polarity reversal protection Overload protection dependent on connected battery and load current: * With 3.2 Ah battery module (6EP1935-6MD11) at +25 C: approx. 10 min at 6 A; 20 min at 4 A; 45 min at 2 A * With 7 Ah battery module (6EP1935-6ME21) at +25 C: approx. 30 min at 6 A; 45 min at 4 A; 150 min at 2 A External floating NO contact required (load max. 15 V DC/max. 10 mA). With the control circuit open, the battery is disconnected from the output L+, and the mains buffering is therefore canceled. Adjustable using DIP switches to maximum buffer time until forced switch-off by exhaustive discharge protection (at approx. 19 V) or to timed buffering from 5 to 635 seconds (in intervals of 10 s) 24 V DC (output voltage of SITOP power supply unit) Input voltage Vin less approx. 0.5 V DC 0 to 6 A Electronic current limitation to 1.05 to 1.4 x Iout rated for approx. 80 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts) Electronic current limitation to 1.5 to 3 x Iout rated for approx. 20 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts) 24 V DC (from battery module) 27 to 19 V DC; 27 V at no load, 25 V at Iout = 0.05 x C x 1/h or 24 V at Iout = 1 x C x 1/h or 23 V at Iout = 2 x C x 1/h (C = total connected battery capacity in Ah), 19 V switch-off threshold for exhaustive discharge protection 0 to 6 A (permanently reliable) Electronic current limitation to 1.05 to 1.4 x Iout rated for approx. 80 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts) Electronic current limitation to 1.5 to 3 x Iout rated for approx. 20 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts) I-V charging characteristic (first constant current I, then constant voltage V) 27.0 V DC 0.1 V (default setting), adjustable in range from 26.3 to 29.3 V (in intervals of 0.1 V) Approx. 0.4 A (default setting), adjustable to 0.2 A or 0.4 A (charging is carried out with the on/off circuit closed or open) 95 %/7 W 94.5 %/8 W Exhaustive discharge protection Against input voltage and batteries with reversed polarity Electronic current limitation to 1.05 to 1.4 x Iout rated for approx. 80 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts) Electronic current limitation to 1.5 to 3 x Iout rated for approx. 20 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts). Internal, non-accessible 16 A fuse Automatic switch-off at battery voltage below approx. 19 V Monitoring "Wire breakage, battery circuit" Monitoring "Battery replacement necessary" Monitoring "Battery charge > 85 %" Alarm signal if battery circuit is not closed or if it opens during operation (cyclic test approx. every 20 s) Alarm signal flashing at approx. 0.25 Hz (approx. 2 s alarm, approx. 2 s no alarm, approx. 2 s alarm etc.). Check every 4 hours if no buffer mode or switch-off has taken place within 4 hours Indication whether batteries are charged to at least 85 % of the rated capacity Short-circuit protection 1) All SITOP 24 V DC power supply units are permissible without limitation. Siemens KT10.1 * 2004 9/7 9 SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 6 A Technical specifications (continued) DC UPS module 6 Order No. 6EP1 931-2DC21 6EP1 931-2DC31 (with serial interface) 6EP1 931-2DC41 (with USB interface) Signalling 1) Normal mode Buffer or battery mode (battery supplies load on its own, or in addition to PS in event of overload) Alarm (buffer readiness missing or prewarning at < 20.4 V battery voltage) "Battery replacement necessary" "Battery charge > 85 %" Optional interface and software Serial interface USB interface 9 Software Green LED (OK) and floating changeover contact "24 V DC OK/Bat" to position "24 V DC OK" 2) Yellow LED (Bat) and floating changeover contact "24 V DC OK/Bat" to position "Bat" (= de-energized position) Red LED (Alarm) and floating changeover contact to position "Alarm" (= de-energized position). Causes for absence of buffer readiness during normal mode could be: Operating status Off or open on/off control circuit, battery module not connected, battery faulty or with reversed polarity (battery voltage < 18.5 V) or wire breakage between battery and UPS module. Scanning and thus updating of the signal every 20 s. Causes for absence of buffer readiness during buffer mode could be: Battery voltage has fallen below 20.4 V DC (= prewarning prior to switching-off by exhaustive discharge protection) as well as switchingoff of battery because of overload, short-circuit, exhaustive discharge protection or expired buffer time. The Red LED then goes off. Red LED (Alarm) flashes at 0.25 Hz and floating changeover contact (Alarm) switches at approx. 0.25 Hz Green LED (Bat > 85 %) and floating NO contact closed (de-energized position = open) Only with 6EP1 931-2DC31 Output of all signals, and receipt of signal "Remote timer start". Techn. design: PC-compatible. 8N1 send and receive, 9600 baud, 8 data bits, 1 stop bit, no parity bit. Required connection to PC: 1 : 1 continuous 9-pole SUB D extension cable (male/female), only pin 2 (RXD), pin 3 (TDX) and pin 7 (RTS) are required. Only with 6EP1 931-2DC41 Output of all signals, and receipt of signal "Remote timer start". Techn. design: Specification 2.0 with full speed, i.e. 2 Mbit/s. Powered by DC UPS with +5 V ("self powered"). Required connection to PC: Commercially available 4-core shielded cable, 90 Ohm, max. 5 m, USB series "A" connector to PC and USB series "B" connector to DC UPS A software tool (executes under WinNT4.0, Win 2000 and WinXP) for reading and processing the signals is available on the Internet at http://www.siemens.de/sitop as a download. Further information on the interface can also be found there. Control signals On/off control signal "Remote timer start" via serial interface or USB By opening the control circuit (or using DIP switch on device), the buffer mode is terminated, or the battery is disconnected from the output. All other functions are retained. Starts the mains buffering for the set buffer time Safety Galvanic isolation primary/secondary Protective class No Class III (ext. circuit and power supply unit: SELV voltage acc. to EN 60950 is required) EMC Interference emission Interference immunity RI suppression acc. to EN 55022, limit characteristic B Interference immunity acc. to EN 61000-6-2 Ambient conditions Ambient temperature during operation Transportation and storage temperature Degree of protection (EN 60529) Humidity rating 0 to +60 C with natural convection -40 to +70 C IP20 Conditions of use acc. to EN 60721, climatic class 3K3 (relative humidity 5 % to 85 % and absolute humidity 1 g/m to 25 g/m; no condensation) Approvals CE UL / cUL CE conformity acc. to 98/336 EEC and 73/23 EEC UL 508 / CSA C22.2, File E197259 Mechanical specifications Connections for 24 V DC input Connections for 24 V DC output Connections for 24 V DC battery module Connections for control circuit and signals 2 screw-type terminals for 1 to 4 mm/17 to 11 AWG 4 screw-type terminals for 1 to 4 mm/17 to 11 AWG 2 screw-type terminals for 1 to 4 mm/17 to 11 AWG 10 screw-type terminals for 0.5 to 2.5 mm/20 to 13 AWG Dimensions (W x H x D) in mm Required clearance Weight Mounting 50 x 125 x approx. 125 50 mm above and 50 mm below the device Approx. 0.4 kg (with serial or USB interface: approx. 0.45 kg) Snap-mounting on DIN rail EN 50022-35x15/7.5 1) Permissible contact rating: 60 V DC/1 A or 30 V AC/1 A. 9/8 Siemens KT10.1 * 2004 2) "24 V DC OK" means: Voltage of power supply unit is greater than the battery connection threshold set on the DC UPS module 6. SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 15 A Technical specifications DC UPS module 15 Order No. 6EP1 931-2EC21 6EP1 931-2EC31 (with serial interface) 6EP1 931-2EC41 (with USB interface) Input L+/ M with normal mode Rated voltage Vin rated 1) Voltage range Connection threshold for battery Rated current Iin rated Stabilized direct voltage 24 V DC 22 to 29 V DC 22.5 V DC 0.1 V (default setting), adjustable in range from 22 to 25.5 V DC (in intervals of 0.5 V) 15 A + approx. 1 A with empty battery Mains buffering Mains buffering or buffer time On/off control circuit Buffer time Output L+/ M with normal mode Rated voltage Vout rated Voltage range Output current Iout Dynamic current with overload Dynamic current with short-circuit Output L+/ M with battery mode Rated voltage Vout rated Voltage range, approx. Output current Iout Dynamic current with overload Dynamic current with short-circuit Output +Bat / -Bat with normal mode End-of-charge voltage V Charging current I Efficiency / power loss At Vout rated, Iout rated approx. With battery operation, approx. Dependent on connected battery and load current: * With 3.2 Ah battery module (6EP1935-6MD11) at +25 C: approx. 45 s at 15 A; 1.5 min at 10 A; 13 min at 5 A * With 7 Ah battery module (6EP1935-6ME21) at +25 C: approx. 7 min at 15 A; 15 min at 10 A; 38 min at 5 A External floating NO contact required (load max. 15 V DC/max. 10 mA). With the control circuit open, the battery is disconnected from the output L+, and the mains buffering is therefore canceled. Adjustable using DIP switches to maximum buffer time until forced switch-off by exhaustive discharge protection (at approx. 19 V) or to timed buffering from 5 to 635 seconds (in intervals of 10 s) 24 V DC (output voltage of SITOP power supply unit) Input voltage Vin less approx. 0.5 V DC 0 to 15 A Electronic current limitation to 1.05 to 1.4 x Iout rated for approx. 80 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts) Electronic current limitation to 1.5 to 3 x Iout rated for approx. 20 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts) 24 V DC (from battery module) 27 to 19 V DC; 27 V at no load, 25 V at Iout = 0.05 x C x 1/h or 24 V at Iout = 1 x C x 1/h or 23 V at Iout = 2 x C x 1/h (C = total connected battery capacity in Ah), 19 V switch-off threshold for exhaustive discharge protection 0 to 15 A (permanently reliable) Electronic current limitation to 1.05 to 1.4 x Iout rated for approx. 80 ms, then electronic switching-off of output with automatic attempt at restarting (approx. 20 s interval between the restart attempts) Electronic current limitation to 1.5 to 3 x Iout rated for approx. 20 ms, then electronic switching-off of output with automatic attempt at restarting (approx. 20 s interval between the restart attempts) I-V charging characteristic (first constant current I, then constant voltage V) 27.0 V DC 0.1 V (default setting), adjustable in range from 26.3 to 29.3 V (in intervals of 0.1 V) Approx. 0.7 A (default setting), adjustable to 0.35 A or 0.7 A (charging is carried out with the on/off circuit closed or open) 96.2 %/14 W 96 %/15 W Protection and monitoring Polarity reversal protection Overload protection Against input voltage and batteries with reversed polarity Electronic current limitation to 1.05 to 1.4 x Iout rated for approx. 80 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts) Short-circuit protection Electronic current limitation to 1.5 to 3 x Iout rated for approx. 20 ms, then electronic switching-off of output with automatic attempts at restarting (approx. 20 s interval between the restart attempts). Internal, non-accessible 16 A fuse Exhaustive discharge protection Automatic switch-off at battery voltage below approx. 19 V Monitoring "Wire breakage, battery circuit" Alarm signal if battery circuit is not closed or if it opens during operation (cyclic test approx. every 20 s) Monitoring "Battery replacement Alarm signal flashing at approx. 0.25 Hz (approx. 2 s alarm, approx. 2 s no alarm, approx. 2 s alarm etc.). necessary" Check every 4 hours if no buffer mode or switch-off has taken place within 4 hours Monitoring "Battery charge > 85 %" Signal whether batteries are charged to at least 85 % of the rated capacity 1) All SITOP 24 V DC power supply units are permissible without limitation. Siemens KT10.1 * 2004 9/9 9 SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 15 A Technical specifications (continued) DC UPS module 15 Order No. 6EP1 931-2EC21 6EP1 931-2EC31 (with serial interface) 6EP1 931-2EC41 (with USB interface) Signalling 1) Normal mode Buffer or battery mode (battery supplies load on its own, or in addition to PS in event of overload) Alarm (buffer readiness missing or prewarning at < 20.4 V battery voltage) "Battery replacement necessary" "Battery charge > 85 %" Optional interface and software Serial interface USB interface 9 Software Control signals On/off control signal "Remote timer start" via serial interface or USB Green LED (OK) and floating changeover contact "24 V DC OK/Bat" to position "24 V DC OK" 2) Yellow LED (Bat) and floating changeover contact "24 V DC OK/Bat" to position "Bat" (= de-energized position) Red LED (Alarm) and floating changeover contact to position "Alarm" (= de-energized position). Causes for absence of buffer readiness during normal mode could be: Operating status Off or open on/off control circuit, battery module not connected, battery faulty or with reversed polarity (battery voltage < 18.5 V) or wire breakage between battery and UPS module. Scanning and thus updating of the signal every 20 s. Causes for absence of buffer readiness during buffer mode could be: Battery voltage fallen below 20.4 V DC (= prewarning prior to switching-off by exhaustive discharge protection) as well as switchingoff of battery because of overload, short-circuit, exhaustive discharge protection or expired buffer time. The Red LED then goes off. Red LED (Alarm) flashes at 0.25 Hz and floating changeover contact (Alarm) switches at approx. 0.25 Hz Green LED (Bat > 85 %) and floating NO contact closed (de-energized position = open) Only with 6EP1 931-2EC31 Output of all signals, and receipt of signal "Remote timer start". Techn. design: PC-compatible. 8N1 send and receive, 9600 baud, 8 data bits, 1 stop bit, no parity bit. Required connection to PC: 1 : 1 continuous 9-pole SUB D extension cable (male/female), only pin 2 (RXD), pin 3 (TDX) and pin 7 (RTS) are required. Only with 6EP1 931-2EC41 Output of all signals, and receipt of signal "Remote timer start". Techn. design: Specification 2.0 with full speed, i.e. 2 Mbit/s. Powered by DC UPS with +5 V ("self powered"). Required connection to PC: Commercially available 4-core shielded cable, 90 Ohm, max. 5 m, USB series "A" connector to PC and USB series "B" connector to DC UPS A software tool (executes under WinNT4.0, Win 2000 and WinXP) for reading and processing the signals is available on the Internet at http://www.siemens.de/sitop as a download. Further information on the interface can also be found there. By opening the control circuit (or using DIP switch on the device), buffer mode is terminated, or the battery is disconnected from the output. All other functions are retained. Starts the mains buffering for the set buffer time Safety Galvanic isolation primary/secondary Protective class No Class III (ext. circuit and power supply unit: SELV voltage acc. to EN 60950 is required) EMC Interference emission Interference immunity RI suppression acc. to EN 55022, limit characteristic B Interference immunity acc. to EN 61000-6-2 Ambient conditions Ambient temperature during operation Transportation and storage temperature Degree of protection (EN 60529) Humidity rating 0 to +60 C with natural convection -40 to +70 C IP20 Conditions of use acc. to EN 60721, climatic class 3K3 (relative humidity 5 % to 85 % and absolute humidity 1 g/m to 25 g/m; no condensation) Approvals CE UL / cUL CE conformity acc. to 98/336 EEC and 73/23 EEC UL 508 / CSA C22.2, File E197259 Mechanical specifications Connections for 24 V DC input Connections for 24 V DC output Connections for 24 V DC battery module Connections for control circuit and signals 2 screw-type terminals for 1 to 4 mm/17 to 11 AWG 4 screw-type terminals for 1 to 4 mm/17 to 11 AWG 2 screw-type terminals for 1 to 4 mm/17 to 11 AWG 10 screw-type terminals for 0.5 to 2.5 mm/20 to 13 AWG Dimensions (W x H x D) in mm Required clearance Weight Mounting 50 x 125 x approx. 125 50 mm above and 50 mm below the device Approx. 0.4 kg (with serial or USB interface: approx. 0.45 kg) Snap-mounting on DIN rail EN 50022-35x15/7.5 1) Permissible contact rating: 60 V DC/1 A or 30 V AC/1 A. 9/10 Siemens KT10.1 * 2004 2) "24 V DC OK" means: Voltage of power supply unit is greater than the battery connection threshold set on the DC UPS module 15. SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 40 A Overview * Mounting depth only approx. 65 mm * Rated output power 480 W with one battery module, 960 W with two battery modules * Extremely high efficiency of approx. 99% as result of patented circuit concept * Immediate electronic connection of battery as soon as the consumer voltage or the voltage present between the L+/M terminals of the DC UPS module falls below a value of 22.5 V DC. The consumer voltage only drops to 22 V DC for a maximum of 1 ms. * High electronically limited peak currents (120 A for approx. 12 ms, up to 40 A for several minutes depending on the battery capacity) are automatically delivered in the event of increased load current requirements (e.g. when switching on incandescent lamps, contactors with DC autotransformer winding, DC motors, DC/DC converters, electronic modules with high input capacitance). To achieve this, at least two battery modules of 7 Ah or more must be connected in parallel. * Following a power failure, the battery module is automatically disconnected from the consumers electronically and rapidly recharged with a constant current of 2 A (V/I characteristic with 27.3 V end-of-charge voltage). * Signalling - Green LED/yellow LED and floating changeover contact for mains/battery mode - Red LED and floating changeover contact for buffer readiness (LED off)/ alarm (LED on) Integration Mains Main switch Power supply 24 V SITOP power 3 AC DC UPS module Load DC UPS module 40 24 V 9 10 to 40 A Message: mains or buffer mode (floating changeover contact) Aux. contact ON/OFF Message: buffer readiness or alarm/prewarning prior to switching-off of battery G_KT01_EN_00159 24 V battery module Block diagram: Configuration of uninterruptible SITOP power supply 40 A Siemens KT10.1 * 2004 9/11 SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 40 A Integration (continued) L+ HSV SITOP F1 DC M power DC V4 V1 US L+ +BAT F2 K1 U BATT L+ V3 U Bat V2 Load M -BAT M Monitoring K2 N/B K3 ALARM 9 N(gn) B(ye) Shield ALARM(rd) G_KT01_en_00160 ON/OFF Block diagram Characteristic curves Voltage characteristic between the terminals L+/M of the DC UPS module with connection of voltage L+/M in V 28.0 26.0 24.0 1 battery module 24 V/7 Ah depending on duration and load current. 22.0 20.0 18.0 16.0 Parameters: Load current 20 A/ 10 A/5 A/2.5 A/1.3 A; 10A 20A 20A 5A 2.5A 10A 5A 1.3A 2 battery modules 24 V/7 Ah 2.5A Parameters: Load current 40 A/ 20 A/10 A/5 A/2.5 A 01 2 4 6 8 10 min 9/12 Siemens KT10.1 * 2004 20 40 1 2 4 6 hours 8 10 20 40 G_KT01_EN_00161 40A SITOP power * Standard 24 V Uninterruptible power supplies DC UPS module 40 A Technical specifications Order No. Input L+/ M with normal mode Rated voltage Vin rated 1) Voltage range Overvoltage strength Connection threshold for battery Mains buffering at Iout rated Rated current Iin rated On/off control circuit Output L+/ M with normal mode Rated voltage Vout rated Voltage range Output current Iout with discharged/ charged battery Output L+/ M with battery mode Rated voltage Vout rated Voltage range, approx. Output current Iout with a battery module of 7 Ah or more Output current Iout with two battery modules of 7 Ah or more Dyn. V/I with short-circuit Output +Bat/-Bat with normal mode End-of-charge voltage Charging current Efficiency/power loss at Vout rated, Iout rated and fully charged battery With battery operation Protection and monitoring Exhaustive discharge protection Short-circuit protection Monitoring "Wire breakage, battery circuit" Signalling On/off (battery switch-off) Normal mode Buffer or battery mode (battery supplies load on its own, or in addition to PS in event of overload) Alarm (buffer readiness missing or prewarning at < 20.4 V battery voltage) Safety Galvanic isolation primary/secondary Protective class TUV test/CE marking UL/cUL (CSA) approval 3) Degree of protection (EN 60529) EMC Interference emission Interference immunity Ambient conditions Ambient temperature range in operation Transportation and storage temperature range Humidity rating Mechanical specifications Input connections 4) L+, M Output connections 4) L+, M Battery connections +/Signals On/Off, N/B, alarm, shield connections Dimensions (W x H x D) in mm, approx. Approx. weight Mounting DC UPS module 40 6EP1 931-2FC01 Stabilized direct voltage 24 V DC 23.5 to 26 V DC VDE 0160 A1 (April 1989), limit curve B2 (2 x Vrated, 0.4 ms) Approx. 22.5 V Dependent on connected battery, see discharge characteristic of battery module 40 A External floating NO contact required (load max. 12 V DC/max. 5 mA). With the control circuit open, the battery is disconnected from the output L+, and the mains buffering is therefore canceled. 24 V DC (output voltage of SITOP power supply unit) Input voltage less approx. 0.1 V 0 to 37 A (max. 3 A required for battery charging)/0 to 40 A 24 V DC (from battery module) 27 to 18.5 V DC; 27 V at no load, 25 V at Iout = 0.05 x C x 1/h or 24 V at Iout = 1 x C x 1/h or 23 V at Iout = 2 x C x 1/h (C = total connected battery capacity in Ah), 18.5 V switch-off threshold for exhaustive discharge protection 0 to 25 A 0 to 40 A Typ. 120 A for approx. 12 ms (with two battery modules of 7 Ah or more) I-V charging characteristic (first constant current I, then constant voltage V) 27.3 V 0.3 V 0 to 2.5 A (typ. 2 A); charging is carried out with the on/off circuit closed or open Approx. 99 %/approx. 7 W 9 Approx. 97 %/approx. 30 W Automatic switch-off at battery voltage < 18.5 V Temperature monitoring of circuit-breaker, electronic switch-off with automatic restart Alarm signal flashing at approx. 1/3 Hz if battery circuit is not closed or if it opens during operation (cyclic test every 20 s) External NO contact (load 12 V DC/5 mA) Green LED + N/B signal (floating changeover contact N/B in position N) 2) Yellow LED + N/B signal (floating changeover contact N/B in position N) 2) Red LED + alarm signal (floating changeover contact for alarm) 2) No Class III (ext. circuit and power supply unit: SELV voltage acc. to EN 60950 is required) Yes/yes Yes, UL/cUL recognized (UL 1950), File E172952 IP20 EN 55022 Class B EN 61000-6-2 0 to +60 C with natural convection -25 to +85 C H acc. to DIN 40040: relative humidity up to 75 % as mean value, 95 % on 30 days/year, no condensation 2 screw-type terminals for 0.5 to 10 mm2 single-core/finely stranded 2 screw-type terminals for 0.5 to 10 mm2 single-core/finely stranded 2 screw-type terminals for 0.5 to 10 mm2 single-core/finely stranded 9 screw-type terminals for 0.5 to 2,5 mm2 single-core/finely stranded 220 x 130 x 65 1.2 kg Snap-mounting on DIN rail EN 50022-35x7.5 or on SITOP power 90 mounting bracket 1) Reliable power supplies are the single-phase SITOP power 10 A and 20 A and the three-phase SITOP power 10 A to 40 A if their output voltage is set between 25 V and 25.5 V DC. The single-phase SITOP power supply units 2 A to 10 A with Order Nos. 6EP13..-1... are not reliable. 2) Permissible contact rating: 60 V DC/1 A or 30 V AC/1 A. 3) Approval only in combination with battery module 7 Ah (6EP1935-6ME01). 4) Both L+ and M connections are electrically connected within the device, and a differentiation of the input/output connections on the device is therefore unnecessary. Siemens KT10.1 * 2004 9/13 SITOP power * Standard 24 V Uninterruptible power supplies Battery module 1.2 Ah Overview Technical specifications Battery module 1.2 Ah Order No. 6EP1 935-6MC01 Battery type, charging current/ charging voltage Maintenance-free lead-acid batteries 1) Recommended end-of-charge voltage (standby use) * For +25 C battery temperature 27.0 V DC * For other battery temperatures 27.8 V for +10 C; 27.3 V for +20 C; 26.8 V for +30 C; 26.7 V for +35 C; 26.6 V for +40 C Recommended charging current Max. 0.3 A Protection Short-circuit protection Battery fuse 15 A/32 V (FK2 flat fuse + holder) Battery protection Valve control Safety * Battery module for DC UPS module 6 A * Contains two maintenance-free, sealed lead-acid batteries from the same batch fitted in a holder and connected in series * Completely prewired with battery fuse holder and terminals * Low self-discharge rate of approx. 3 % per month (at +20 C) 9 Protective class Class III UL/cUL (CSA) approval UL/cUL recognized (UL1778, CSA 22.2 No. 107.1-95), File E219627 Degree of protection (EN 60529) IP00 Operating specifications Ambient temperature range +5 to +40 C Transportation and storage temperature range -20 to +50 C Self-discharge rate Approx. 3 % per month at a battery temperature of 20 C (increased value at higher temperature) Service life The service life of the chemical lead-acid batteries (reduction to 50 % of original capacity) depends on the battery temperature as follows: At +20 C Approx. 4 years At +25 C Approx. 3.5 years At +30 C Approx. 3 years At +35 C Approx. 2.5 years At +40 C Approx. 2 years At +45 C Approx. 1.5 years At +50 C Approx. 1 year Mechanical specifications 1) For storage, installation and operation of the lead-acid batteries, the appropriate DIN/VDE regulations or the country-specific directives (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. The battery location must be sufficiently ventilated, potential ignition sources must be at least 50 cm away. 9/14 Siemens KT10.1 * 2004 Connection 1 terminal each for 0.08 to 2.5 mm2 for + BAT and - BAT Supplied accessories Accessory pack with FK2 fuse 15 A Dimensions (W x H x D) in mm Approx. 96 x 106 x 108 Weight Approx. 2 kg Mounting Snap-mounting on DIN rail EN 50022-35x15/7.5 or keyhole mounting for hanging in M4 screws SITOP power * Standard 24 V Uninterruptible power supplies Battery module 2.5 Ah Overview Technical specifications Battery module 2.5 Ah Order No. 6EP1 935-6MD31 Battery type, charging current/ charging voltage Maintenance-free chemical lead-acid batteries 1) Recommended end-of-charge voltage (standby use) * For +25 C battery temperature 27.7 V DC * For other battery temperatures 29.0 V for -10 C; 28.6 V for 0 C; 28.3 V for +10 C; 27.9 V for +20 C; 27.5 V for +30 C; 27.2 V for +40 C; 26.8 V for +50 C; 26.4 V for +60 C Recommended charging current Max. 5 A Protection * High-temperature battery for DC UPS module 6 A and 15 A * Contains two maintenance-free, sealed chemical lead-acid batteries from the same batch fitted in a holder and connected in series * Completely prewired with battery fuse holder and terminals * Low self-discharge rate of approx. 3 % per month (at +20 C) Short-circuit protection Battery fuse 15 A/32 V (FK2 flat fuse + holder) Battery protection Valve control Safety Protective class Class III UL/cUL (CSA) approval UL/cUL recognized (UL1778, CSA 22.2 No. 107.1-95), File E219627 Degree of protection (EN 60529) IP00 Operating specifications Ambient temperature range -40 to +60 C with natural convection Transportation and storage temperature range -40 to +60 C Self-discharge rate Approx. 3 % per month at a battery temperature of 20 C (increased value at higher temperature) 9 Service life The service life of the chemical lead-acid batteries (reduction to 80 % of original capacity) depends on the battery temperature as follows: At +15 C Approx. 19 years At +20 C Approx. 13 years At +25 C Approx. 9 years At +30 C Approx. 7 years At +35 C Approx. 5 years At +40 C Approx. 3 years At +45 C Approx. 2 years At +50 C Approx. 1.5 years At +60 C Approx. 1 year Mechanical specifications Connection 1 terminal each for 0.08 to 2.5 mm2 for + BAT and - BAT Supplied accessories Accessory pack with FK2 fuse 15 A Dimensions (W x H x D) in mm Approx. 265 x 151 x 91 Weight Approx. 3.8 kg Mounting Snap-mounting on DIN rail EN 50022-35x15/7.5 or keyhole mounting for hanging in M4 screws 1) For storage, installation and operation of the lead-acid batteries, the appropriate DIN/VDE regulations or the country-specific directives (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. The battery location must be sufficiently ventilated, potential ignition sources must be at least 50 cm away. Siemens KT10.1 * 2004 9/15 SITOP power * Standard 24 V Uninterruptible power supplies Battery module 3.2 Ah Overview Technical specifications Battery module 3.2 Ah Order No. 6EP1 935-6MD11 Battery type, charging current/ charging voltage Maintenance-free, sealed leadacid batteries 1) Recommended end-of-charge voltage (standby use) * For +25 C battery temperature 27.0 V DC * For other battery temperatures 27.8 V for +10 C; 27.3 V for +20 C; 26.8 V for +30 C; 26.7 V for +35 C; 26.6 V for +40 C Recommended charging current Max. 0.8 A Protection Short-circuit protection Battery fuse 15 A/32 V (FK2 flat fuse + holder) Battery protection Valve control Safety * Battery module for DC UPS module 6 A and 15 A * Contains two maintenance-free, sealed lead-acid batteries from the same batch fitted in a holder and connected in series * Includes battery fuse holder and terminals * Low self-discharge rate of approx. 3 % per month (at +20 C) 9 Protective class Class III UL/cUL (CSA) approval UL/cUL recognized (UL1778, CSA 22.2 No. 107.1-95), File E219627 Degree of protection (EN 60529) IP00 Operating specifications Ambient temperature range +5 to +40 C with natural convection Transportation and storage temperature range -20 to +50 C Self-discharge rate Approx. 3 % per month at a battery temperature of 20 C (increased value at higher temperature) Service life The service life of the chemical lead-acid batteries (reduction to 50 % of original capacity) depends on the battery temperature as follows: At +20 C Approx. 4 years At +25 C Approx. 3.5 years At +30 C Approx. 3 years At +35 C Approx. 2.5 years At +40 C Approx. 2 years At +45 C Approx. 1.5 years At +50 C Approx. 1 year Mechanical specifications 1) For storage, installation and operation of the lead-acid batteries, the appropriate DIN/VDE regulations or the country-specific directives (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. The battery location must be sufficiently ventilated, potential ignition sources must be at least 50 cm away. 9/16 Siemens KT10.1 * 2004 Connection 1 terminal each for 0.08 to 2.5 mm2 for + BAT and - BAT Supplied accessories Accessory pack with FK2 fuse 15 A Dimensions (W x H x D) in mm Approx. 190 x 151 x approx. 82 Weight Approx. 3.2 kg Mounting Snap-mounting on DIN rail EN 50022-35x15/7.5 or keyhole mounting for hanging in M4 screws SITOP power * Standard 24 V Uninterruptible power supplies Battery module 7 Ah Overview Technical specifications Battery module 7 Ah Order No. 6EP1 935-6ME21 Battery type, charging current/ charging voltage Maintenance-free, sealed leadacid batteries 1) Recommended end-of-charge voltage (standby use) * For +25 C battery temperature 27.0 V DC * For other battery temperatures 27.8 V for +10 C; 27.3 V for +20 C; 26.8 V for +30 C; 26.7 V for +35 C; 26.6 V for +40 C Recommended charging current Max. 1.75 A Protection Short-circuit protection Battery fuse 15 A/32 V (FK2 flat fuse + holder) Battery protection Valve control Safety * Battery for DC UPS module 6 A and 15 A and DC UPS module 40 A * Contains two maintenance-free, sealed lead-acid batteries from the same batch fitted in a holder and connected in series * Completely prewired with battery fuse holder and terminals * Accessory pack with FK2 spare fuses 15 A and 20 A * Low self-discharge rate of approx. 3 % per month (at +20 C) Protective class Class III UL/cUL (CSA) approval UL/cUL recognized (UL1778, CSA 22.2 No. 107.1-95), File E219627 Degree of protection (EN 60529) IP00 Operating specifications Ambient temperature +5 to +40 C Transportation and storage temperature range -20 to +50 C Self-discharge rate Approx. 3 % per month at a battery temperature of 20 C Service life The service life of the chemical lead-acid batteries (reduction to 50 % of original capacity) depends on the battery temperature as follows: At +20 C Approx. 4 years At +25 C Approx. 3.5 years At +30 C Approx. 3 years At +35 C Approx. 2.5 years At +40 C Approx. 2 years At +45 C Approx. 1.5 years At +50 C Approx. 1 year Mechanical specifications Connection 1 terminal each for 0.08 to 4 mm2 for + BAT - BAT Supplied accessories Accessory pack with FK2 spare fuses 15 A and 20 A Dimensions (W x H x D) in mm Approx. 186 x 168 x 121 Weight Approx. 6.0 kg Mounting Can be screwed on level surface (Keyhole mounting for hanging in M4 screws) 1) For storage, installation and operation of the lead-acid batteries, the appropriate DIN/VDE regulations or the country-specific directives (e.g. VDE 0510 Part 2/EN 50272-2) must be observed.The battery location must be sufficiently ventilated, potential ignition sources must be at least 50 cm away. Siemens KT10.1 * 2004 9/17 9 SITOP power * Standard 24 V Uninterruptible power supplies Battery module 12 Ah Overview Technical specifications Battery module 12 Ah Order No. 6EP1 935-6MF01 Battery type, charging current/ charging voltage Maintenance-free, sealed leadacid batteries 1) Recommended end-of-charge voltage (standby use) * For +25 C battery temperature 27.0 V DC * For other battery temperatures 27.8 V for +10 C; 27.3 V for +20 C; 26.8 V for +30 C; 26.7 V for +35 C; 26.6 V for +40 C Recommended charging current Max. 3 A Protection Short-circuit protection Battery fuse 15 A/32 V (FK2 flat fuse + holder) Battery protection Valve control Safety * Battery for DC UPS module 6 A and 15 A and DC UPS module 40 A * Contains two maintenance-free, sealed lead-acid batteries from the same batch fitted in a holder and connected in series * Completely prewired with battery fuse holder and terminals * Accessory pack with FK2 spare fuses 15 A and 20 A * Low self-discharge rate of approx. 3 % per month (at +20 C) 9 Protective class Class III UL/cUL (CSA) approval UL/cUL recognized (UL1778, CSA 22.2 No. 107.1-95), File E219627 Degree of protection (EN 60529) IP00 Operating specifications Ambient temperature +5 to +40 C Transportation and storage temperature range -20 to +50 C Self-discharge rate Approx. 3 % per month at a battery temperature of 20 C Service life The service life of the chemical lead-acid batteries (reduction to 50 % of original capacity) depends on the battery temperature as follows: At +20 C Approx. 4 years At +25 C Approx. 3.5 years At +30 C Approx. 3 years At +35 C Approx. 2.5 years At +40 C Approx. 2 years At +45 C Approx. 1.5 years At +50 C Approx. 1 year Mechanical specifications 1) For storage, installation and operation of the lead-acid batteries, the appropriate DIN/VDE regulations or the country-specific directives (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. The battery location must be sufficiently ventilated, potential ignition sources must be at least 50 cm away. 9/18 Siemens KT10.1 * 2004 Connection 1 terminal each for 0.08 to 4 mm2 for + BAT - BAT Supplied accessories Accessory pack with FK2 spare fuses 15 A and 20 A Dimensions (W x H x D) in mm Approx. 253 x 118 x 121 Weight Approx. 9.0 kg Mounting Can be screwed on level surface (Keyhole mounting for hanging in M4 screws) 10 SITOP power Alternative voltages 10/2 10/2 10/2 SITOP power flexi 120 W SITOP power dual 15 V SITOP modular 48 V/20 A Siemens KT10.1 * 2004 SITOP power Alternative voltages Overview Application SITOP power flexi 120 W SITOP power dual 15 V SITOP modular 48 V/20 A The power supply unit with adjustable output voltage from 3 V to 52 V; suitable for all applications where a special voltage deviating from 24 V is required. The industry-standard power supply unit with two 15 V outputs which can be connected in parallel or in series; can be used, for example, for supplying electronic loads with 15 V. The modular 48 V power supply unit with three-phase widerange input for powerful loads which are powered by twice the voltage instead of the usual 24 V. Technical specifications 10 Power supply, type 3 to 52 V/2 to 10 A 2 x 15 V/3.5 A 48 V/20 A Order No. 6EP1 353-2BA00 6EP1 353-0AA00 6EP1 457-3BA00 Input Rated voltage Vin rated Voltage range Single-phase AC 120/230 V AC Settable using wire jumper 85 to 132 V/170 to 264 V AC Single-phase AC 120 to 230 V AC wide-range input 93 to 264 V AC Three-phase AC 400 to 500 V 3 AC wide-range input 320 to 550 V (startup from Vin > 340 V) Overvoltage strength 2.3 x Vin rated, 1.3 ms Surge voltage acc. to EN 61000-6-2 Table 4 2.3 x Vin rated, 1.3 ms Mains buffering at Iout rated > 10 ms at Vin = 93/187 V (Pout = 120 W) 50/60 Hz, 47 to 63 Hz 2.2/0.9 A < 32 A > 10/40 ms at Vin = 120/187 V > 6 ms at Vin = 400 V 50/60 Hz; 47 to 63 Hz 1.9 to 1.15 A < 30 A, typ. 3 ms 50/60 Hz; 47 to 63 Hz 2.2 A (Vin = 400 V) < 70 A I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 0.8 A2s T3.15 A/250 V (not accessible) From 6 A Characteristic C < 3 A2 s T4 A/250 V (not accessible) From 10 A Characteristic C or from 16 A Characteristic B < 2.8 A2s none Required: 3-pole coupled circuit-breaker 10 to 16 A Char. C or motor circuit-breaker 3RV1021-1DA10, setting 3 A Output Rated voltage Vout rated Total tolerance * Stat. mains compensation * Stat. load compensation Sense line connection Stabilized, floating direct voltage 3 to 52 V DC 1% Approx. 0.1 % Approx. 0.2 % Yes, maximum voltage control 0.5 V per line Stabilized, floating direct voltage 2 x 15 V DC 2% Approx. 0.2 % Approx. 0.2 % - Stabilized, floating direct voltage 48 V DC 3% Approx. 0.1 % Approx. 0.2 % - Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) Setting range < 50 mVpp < 50 mVpp (typ. 20 mVpp) < 100 mVpp < 100 mVpp 3 to 52 V, via potentiometer or analog control voltage signal 0 to 2.5 V Green LED for 24 V O.K. < 150 mVpp (typ. 150 mVpp) 14.5 to 17 V < 200 mVpp 42 to 56 V (max. 960 W) Green LED for Vout >10 V (summation display) - Green LED for 48 V O.K. Rated line frequency; range Rated current Iin rated Inrush current limitation (+ 25 C) Status display Signalling Power ON/OFF behavior Starting delay/voltage rise Rated current Iout rated Current range * up to + 45 C * up to + 60 C Continued on page 10/3. 10/2 Siemens KT10.1 * 2004 Power Good via relay contact, current monitor signal 0 to 2.5 V No overshoot of Vout (soft start) possible using signalling module (6EP1 961-3BA10) Overshoot of Vout < 3% No overshoot of Vout (soft start) < 3 s/typ. 80 ms 2 to 10 A (max. 120 W) <1s 2 x 3.5 A < 2.5 s/< 500 ms 20 A 0 to 10 A (max. 120 W) 0 to 10 A (max. 120 W) 2 x 0 to 3.5 A 2 x 0 to 2.5 A 0 to 20 A 0 to 20 A SITOP power Alternative voltages Technical specifications (continued) Power supply, type 3 to 52 V/2 to 10 A 2 x 15 V/3.5 A 48 V/20 A Order No. 6EP1 353-2BA00 6EP1 353-0AA00 6EP1 457-3BA00 Dyn. V/I with * Starting on short circuit * Short-circuit in operation Parallel connection for increased output Constant current 2 to 10 A Constant current 2 to 10 A Yes, 2 Yes, 2 Constant current approx. 23 A typ. 60 A for 25 ms Yes, 2 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Approx. 84 % (at 24 V/5 A) Approx. 23 W (at 24 V/5 A) Approx. 80 % Approx. 27 W Approx. 90 % Approx. 106 W Yes, acc. to EN 60950 2 to 10 A, adjustable via potentiometer or analog control voltage signal 0 to 2.5 V Yes, acc. to EN 60950 Limit point < 4.9 A; switch-off point < 6 A Yes, acc. to EN 60950 typ. 23 A Electronic current limiting (2 to 10 A) in the range 3 to12 V or power limiting (120 W) in the range 12 to 52 V Red LED for current or power limiting Electronic shutdown, automatic restart Choice of stabilized current characteristic approx. 23 A or latching shutdown - Yellow LED for "overload", red LED for "latching shutdown" Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class I < 3.5 mA Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA Yes, SELV output voltage Vout acc. to EN 60950 Class I < 3.5 mA TUV test CE marking UL/cUL (CSA) approval Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E143289 Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M91), File E179336 Yes Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M95), File E197259 FM approval Appr. for use in marine vessels Degree of protection (EN 60529) IP20 IP20 IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B EN 61000-3-2 EN 61000-6-2 EN 55011 Class A EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 0 to +60 C with natural convection 0 to +60 C with natural convection, derating above +45 C 0 to +60 C with natural convection -40 to +70 C -25 to +85 C Climatic class 3K3 acc. to EN 60721 Climatic class 3K3 acc. to EN 60721 One screw-type terminal each for 0.2 to 4 mm2 single-core/finely stranded (L1, L2, L3, PE) 2 screw-type terminals each for 0.33 to 10 mm2 (+, -) Protection and monitoring Output overvoltage protection Current limitation Short-circuit protection Overload/short-circuit indicator Safety Galvanic isolation primary/ secondary Protective class Discharge current Operating specifications Ambient temperature range Transportation and storage tempera- -25 to + 85 C ture range Humidity rating Climatic class 3K3 acc. to EN 60721 10 Mechanical specifications Connections * Mains input L1, N, PE One screw-type terminal each for 0.5 to 2.5 mm2 single-core/finely stranded One screw-type terminal each for 0.5 to 2.5 mm2 single-core/finely stranded * Output One screw-type terminal for 0.5 to 2.5 mm2 (L+) and 2 screw-type terminals for 0.5 to 2.5 mm2 (M) * Messages, control inputs One screw-type terminal each for 0.14 to 1.5 mm2 One screw-type terminal for 0.5 to 2.5 mm2 (P15_1, GND1, GDN2) and 2 screw-type terminals for 0.5 to 2.5 mm2 (P15_2) - Dimensions (W x H x D) in mm Weight approx. Mounting 75 x 125 x 125 Approx. 0.9 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 75 x 125 x 125 Approx. 0.75 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 240 x 125 x 125 3.2 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Accessories - - Signalling module (6EP1961-3BA10) - Siemens KT10.1 * 2004 10/3 SITOP power Alternative voltages Notes 10 10/4 Siemens KT10.1 * 2004 11 SITOP power AS interface power supplies 11/2 11/2 The IP65 version The IP20 version Siemens KT10.1 * 2004 SITOP power AS interface power supplies Single-phase AS interface power supplies, stabilized Overview The IP65 version The IP20 version The AS interface power supply unit with IP65 degree of protection for any mounting position is particularly suitable for use in extremely harsh environments. Thanks to the 24 V DC input voltage it is ideally suitable for use together with a proven SITOP power 24 V standard power supply unit. This AS interface power supply unit with its wide-range input of 93 to 264 V AC and 110 to 350 V DC can be universally used in all typical power supply networks. With limitation of the input current harmonics acc. to EN 61000-3-2; with SIMATIC S7-300 design. Power supply, type 2.4 A 7A Order No. 6EP1 632-1AL01 6EP1 354-1AL01 Input DC voltage Single-phase AC Rated voltage Vin rated 24 V DC 120 to 230 V AC wide-range input 93 to 264 V AC/110 to 350 V DC Application Technical specifications 11 Voltage range 20.4 to 28.8 V DC Overvoltage strength 35 V DC for max. 500 ms 2.3 x Vin rated, 1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated input current Iin rated Inrush current limitation (+25 C) > 10 ms 3.6 A - > 20 ms at Vin = 93/187 V 0/50/60 Hz; 47 to 63 Hz 2.2 to 1.2 A < 20 A, < 3 ms I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line T 6.3 A (not accessible) From 10 A, Characteristic C or from 6 A, Characteristic D < 1.5 A2s T 6.3 A (not accessible) From 16 A, Characteristic C Output Rated voltage Vout rated Stabilized, floating direct voltage acc. to AS interface specifications 30 V DC Stabilized, floating direct voltage acc. to AS interface specification 30 V DC Total tolerance Residual ripple Spikes Status display Rated current Iout rated 29.5 V to 31.6 V DC < 300 mVpp < 50 mVpp Green LED 2.4 A 29.5 to 31.6 V DC < 300 mVpp < 50 mVpp Green LED 7A Efficiency / power loss Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated > 81% < 17 W > 85% < 37 W From approx. 2.9 A Constant current characteristic approx. 2.9 A Yes From approx. 7.4 A Constant current characteristic approx. 7.4 A Protection and monitoring functions Output overvoltage protection Current limiting Short-circuit protection Continued on page 11/3. 11/2 Siemens KT10.1 * 2004 SITOP power AS interface power supplies Single-phase AS interface power supplies, stabilized Power supply, type 2.4 A 7A Order No. 6EP1 632-1AL01 6EP1 354-1AL01 Yes, SELV output voltage Vout acc. to EN 60950 Class I IP65 1) Yes UL (UL 508), File 179336, CSA (CSA 22.2 No. 14-95) Yes, SELV output voltage Vout acc. to EN 60950 Class I IP20 Yes cULus (UL 508, CSA 22.2 No.14-M91), File E143289 EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 -25 to +55 C -25 to +85 C 0 to +55 C -25 to +85 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Circular connector 0.5 to 2.5 mm2 1) 2) 500 mm three-core cable AWG 14 1) 500 mm three-core cable AWG 14 1) 500 mm three-core cable AWG 14 1) One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 Dimensions (W x H x D) in mm Weight approx. Mounting 224 x 80 x 57 1.0 kg Wall mounting, any mounting position 200 x 125 x 135 1.8 kg Snap-mounting on DIN rail EN 50022-35x15 mm and S7 rail Accessories 6-pin circular input connector (6ES5 760-2CA11) and AS interface coupling module PG (3RG9 220-0AA00) - Safety Galvanic isolation primary/secondary Protective class Degree of protection (EN 60529) CE marking UL/cUL (CSA) approval EMC Interference emission Line harmonics limitation Interference immunity Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Input connections Output connections AS i + Output connections AS i Output connections Ground 11 1) In IP20 degree of protection with screw-type terminals on request. 2) The counterpart must be ordered separately (not included in the scope of delivery); see Accessories. Siemens KT10.1 * 2004 11/3 SITOP power AS interface power supplies Notes 11 11/4 Siemens KT10.1 * 2004 12 SITOP power Customized 12/2 12/3 Description Specification sheet Siemens KT10.1 * 2004 SITOP power Customized Overview Our tried and tested standard power supplies cannot, of course, be suitable for absolutely every application. Does your application require a voltage level other than 24 V, or is a 19" or openframe version necessary, or are the environmental conditions of your system sometimes outside the normal ranges? We offer the possibility for optimum adaptation to your application-specific requirements. Thanks to the experience and know-how of our development team, we are able to offer you a tailored solution by applying a modular power supply concept. Your specific requirements can be fulfilled by modifying existing equipment or by complete new developments on the basis of pre-developed standard components. Your advantages are evident: * Adaptation of the power supply to your application, and not vice versa as in the past * Highly flexible electrical parameters * AC or DC input * Several output voltages possible * High reliability through use of standard components * Variability with respect to design requirements * Adaptable mechanical system. You therefore benefit from the competence of mass production together with a maximum of development reliability and quality. Further decisive criteria for the success of your application are: * High availability thanks to fast development cycles * Short time span between development and start of series production thanks to tried and tested launch procedures * Prices in line with the market. Our customized solutions are currently in use in many sectors of mechanical engineering, automation engineering, vehicle electronics, equipment design and industrial measurement engineering, among others. Our product range is open to any application. If you are interested and require further information, please copy the following page, fill in the parameters of your specific requirement and fax it to the stated number. Form for inquiry is also available at: http://intra1.nbgm.siemens.de/extern/spiegeln/ sitop/html_76/formular.htm 12 You can fill it out right on the screen and send it to us immediately. We will contact you without delay. 12/2 Siemens KT10.1 * 2004 SITOP power Customized FAX reply Specification sheet for customized power supplies Recipient: Sender: SIEMENS AG A&D SE PS 1 Wurzburger Strae 121 90766 Furth Company: FAX: 0911 750-9991 Name: Department: City: FAX: Phone: Application: Electrical requirements: Input voltage: Vin: Tolerance D Vin : Frequency: fin: Tolerance D fin : Mains buffering time: Tin: Output voltage: Vout1: Vout2: Vout3: Vout4: Output current: Iout1: Iout2: Iout3: Iout4: Other: Mechanical requirements: Design/dimensions: (attach drawing if necessary) Enclosure: Connections: Other: General requirements: 12 Efficiency: Ambient temperature: Standards: Quantity/year: Signalling: EN 60950 UL EN 61000-6-1/2 EN 61000-6-3/4 cUL (CSA) Delivery: Price expectations: Remarks: Siemens KT10.1 * 2004 12/3 SITOP power Customized Notes 12 12/4 Siemens KT10.1 * 2004 13 LOGO!Power 13/2 13/4 13/6 13/8 LOGO!Power 5 V LOGO!Power 12 V LOGO!Power 15 V LOGO!Power 24 V Siemens KT10.1 * 2004 LOGO!Power LOGO!Power 5 V Overview LOGO!Power 5 V Application LOGO!Power supplies are primary switched-mode power supplies that are optimized to the LOGO! logic modules in terms of functionality and design. With the wide input range of 85 V to 264 V AC, radio interference level B and assembly option in built-in miniature distribution boards, they can be used universally in a diverse range of applications in the low-end performance range. Technical specifications Power supply, type 5 V/3 A 5 V/6.3 A Order No. 6EP1 311-1SH02 6EP1 311-1SH12 Input Rated voltage Vin rated Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Voltage range Overvoltage strength 2.3 x Vin rated/1.3 ms 2.3 x Vin rated/1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 0.36 to 0.22 A < 15 A > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 0.71 to 0.37 A < 30 A I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 0.8 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C < 3 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C Output Rated voltage Vout rated Total tolerance, static * Static mains compensation * Static load compensation Stabilized, floating direct voltage 5 V DC 3% Approx. 0.2 % Approx. 1.5 % Stabilized, floating direct voltage 5 V DC 3% Approx. 0.1 % Approx. 2 % Residual ripple (clock frequency approx. 90 kHz) Spikes (bandwidth approx. 20 MHz) Setting range Status display < 100 mVpp < 100 mVpp < 100 mVpp 4.6 to 5.4 V Green LED for output voltage OK No overshoot of Vout (soft start) < 100 mVpp 4.6 to 5.4 V Green LED for output voltage OK No overshoot of Vout (soft start) < 0.5 s/typ. 15 ms 3A 0 to 3 A Yes < 0.5 s/typ. 10 ms 6.3 A 0 to 6.3 A Yes Power ON/OFF behavior 13 Starting delay/voltage rise Rated current Iout rated Current range up to +55 C Parallel connection for increased output Continued on page 13/3. 13/2 Siemens KT10.1 * 2004 LOGO!Power LOGO!Power 5 V Power supply, type 5 V/3 A 5 V/6.3 A Order No. 6EP1 311-1SH02 6EP1 311-1SH12 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated typ. 76 % typ. 5 W typ. 83 % typ. 6 W < 0.2 % Vout < 0.2 % Vout 4 % Vout 6.5 % Vout Settling time * Load step from 10 to 90 % * Load step from 90 to 10 % typ. 20 ms typ. 20 ms typ. 20 ms typ. 20 ms Protection and monitoring Current limitation Short-circuit protection RMS sustained short-circuit current Overload/short-circuit indicator typ. 3.8 A Stabilized current characteristic <5A - typ. 8.2 A Stabilized current characteristic < 10 A - Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M95), File E197259; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M95), File E197259; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 Appr. for use in marine vessels Degree of protection (EN 60529) Yes, Class I Div. 2, Group A, B, C, D T4 Yes, GL (Germanischer Lloyd) IP20 Yes, Class I Div. 2, Group A, B, C, D T4 Yes, GL (Germanischer Lloyd) IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 -20 to +55 C with natural convection -40 to +70 C -20 to +55 C with natural convection -40 to +70 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals each for 0.5 to 2.5 mm2 2 screw-type terminals each for 0.5 to 2.5 mm2 54 x 90 x 55 Approx. 0.17 kg Snap-mounting on DIN rail EN 50022-35x7.5/15 72 x 90 x 55 Approx. 0.25 kg Snap-mounting on DIN rail EN 50022-35x7.5/15 Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 10/90/10 %) Safety Galvanic isolation primary/secondary Protective class CE marking UL/cUL (CSA) approval FM approval Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Mains input connections L1, N Connections * Output + * Output Dimensions (W x H x D) in mm Weight Mounting 13 Siemens KT10.1 * 2004 13/3 LOGO!Power LOGO!Power 12 V Overview Application LOGO!Power supplies are primary switched-mode power supplies that are optimized to the LOGO! logic modules in terms of functionality and design. With the wide input range of 85 V to 264 V AC, radio interference level B and assembly option in built-in miniature distribution boards, they can be used universally in a diverse range of applications in the low-end performance range. Technical specifications Power supply, type 12 V/1.9 A 12 V/4.5 A Order No. 6EP1 321-1SH02 6EP1 322-1SH02 Input Rated voltage Vin rated Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Voltage range Overvoltage strength 2.3 x Vin rated/1.3 ms 2.3 x Vin rated/1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 0.53 to 0.3 A < 15 A > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 1.13 to 0.61 A < 30 A I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 0.8 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C < 3 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C Output Rated voltage Vout rated Total tolerance, static * Static mains compensation * Static load compensation Stabilized, floating direct voltage 12 V DC 3% Approx. 0.2 % Approx. 1.5 % Stabilized, floating direct voltage 12 V DC 3% Approx. 0.1 % Approx. 1.5 % Residual ripple (clock frequency approx. 90 kHz) Spikes (bandwidth approx. 20 MHz) Setting range Status display < 200 mVpp < 200 mVpp < 300 mVpp 10.5 to 16.1 V Green LED for output voltage OK No overshoot of Vout (soft start) < 300 mVpp 10.5 to 16.1 V Green LED for output voltage OK No overshoot of Vout (soft start) < 0.5 s/typ. 15 ms 1.9 A 0 to 1.9 A Yes < 0.5 s/typ. 10 ms 4.5 A 0 to 4.5 A Yes Power ON/OFF behavior 13 Starting delay/voltage rise Rated current Iout rated Current range up to +55 C Parallel connection for increased output Continued on page 13/5. 13/4 Siemens KT10.1 * 2004 LOGO!Power LOGO!Power 12 V Power supply, type 12 V/1.9 A 12 V/4.5 A Order No. 6EP1 321-1SH02 6EP1 322-1SH02 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated typ. 80 % typ. 5 W typ. 85 % typ. 10 W < 0.2 % Vout < 0.2 % Vout 3 % Vout 4.2 % Vout Settling time * Load step from 10 to 90 % * Load step from 90 to 10 % typ. 20 ms typ. 20 ms typ. 20 ms typ. 20 ms Protection and monitoring Current limitation Short-circuit protection RMS sustained short-circuit current Overload/short-circuit indicator typ. 2.5 A Stabilized current characteristic <4A - typ. 5.9 A Stabilized current characteristic <8A - Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M95), File E197259; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M95), File E197259; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 Appr. for use in marine vessels Degree of protection (EN 60529) Yes, Class I Div. 2, Group A, B, C, D T4 Yes, GL, ABS IP20 Yes, Class I Div. 2, Group A, B, C, D T4 Yes, GL, ABS IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 -20 to +55 C with natural convection -40 to +70 C -20 to +55 C with natural convection -40 to +70 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 single-core/ finely stranded 2 screw-type terminals each for 0.5 to 2.5 mm2 One screw-type terminal each for 0.5 to 2.5 mm2 single-core/ finely stranded 2 screw-type terminals each for 0.5 to 2.5 mm2 54 x 90 x 55 Approx. 0.17 kg Snap-mounting on DIN rail EN 50022-35x7.5/15 72 x 90 x 55 Approx. 0.25 kg Snap-mounting on DIN rail EN 50022-35x7.5/15 Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout:10/90/10 %) Safety Galvanic isolation primary/secondary Protective class CE marking UL/cUL (CSA) approval FM approval Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Connections * Mains input L1, N * Output + * Output Dimensions (W x H x D) in mm Weight Mounting 13 Siemens KT10.1 * 2004 13/5 LOGO!Power LOGO!Power 15 V Overview Application LOGO!Power supplies are primary switched-mode power supplies that are optimized to the LOGO! logic modules in terms of functionality and design. With the wide input range of 85 V to 264 V AC, radio interference level B and assembly option in built-in miniature distribution boards, they can be used universally in a diverse range of applications in the low-end performance range. Technical specifications Power supply, type 15 V/1.9 A 15 V/4 A Order No. 6EP1 351-1SH02 6EP1 352-1SH02 Input Rated voltage Vin rated Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Voltage range Overvoltage strength 2.3 x Vin rated/1.3 ms 2.3 x Vin rated/1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 0.63 to 0.33 A < 15 A > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 1.24 to 0.68 A < 30 A I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 0.8 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C < 3 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C Output Rated voltage Vout rated Total tolerance, static * Static mains compensation * Static load compensation Stabilized, floating direct voltage 15 V DC 3% Approx. 0.1 % Approx. 1.5 % Stabilized, floating direct voltage 15 V DC 3% Approx. 0.1 % Approx. 1.5 % Residual ripple (clock frequency approx. 90 kHz) Spikes (bandwidth approx. 20 MHz) Setting range Status display < 200 mVpp < 200 mVpp < 300 mVpp 10.5 to 16.1 V Green LED for output voltage OK No overshoot of Vout (soft start) < 300 mVpp 10.5 to 16.1 V Green LED for output voltage OK No overshoot of Vout (soft start) < 0.5 s/typ. 15 ms 1.9 A 0 to 1.9 A Yes < 0.5 s/typ. 10 ms 4A 0 to 4 A Yes Power ON/OFF behavior 13 Starting delay/voltage rise Rated current Iout rated Current range up to +55 C Parallel connection for increased output Continued on page 13/7. 13/6 Siemens KT10.1 * 2004 LOGO!Power LOGO!Power 15 V Power supply, type 15 V/1.9 A 15 V/4 A Order No. 6EP1 351-1SH02 6EP1 352-1SH02 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated typ. 80 % typ. 7 W typ. 85 % typ. 11 W < 0.2 % Vout < 0.2 % Vout 2.8 % Vout 3.3 % Vout Settling time * Load step from 10 to 90 % * Load step from 90 to 10 % typ. 20 ms typ. 20 ms typ. 20 ms typ. 20 ms Protection and monitoring Current limitation Short-circuit protection RMS sustained short-circuit current Overload/short-circuit indicator typ. 2.7 A Stabilized current characteristic <4A - typ. 5.0 A Stabilized current characteristic <8A - Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M95), File E197259; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2 No. 14-M95), File E197259; cURus recognized (UL 60950, CSA 22.2 No. 60950), File E151273 Appr. for use in marine vessels Degree of protection (EN 60529) Yes, Class I Div. 2, Group A, B, C, D T4 Yes, GL (Germanischer Lloyd) IP20 Yes, Class I Div. 2, Group A, B, C, D T4 Yes, GL (Germanischer Lloyd) IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 -20 to +55 C with natural convection -40 to +70 C -20 to +55 C with natural convection -40 to +70 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals each for 0.5 to 2.5 mm2 2 screw-type terminals each for 0.5 to 2.5 mm2 54 x 90 x 55 Approx. 0.17 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 72 x 90 x 55 Approx. 0.25 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 10/90/10 %) Safety Galvanic isolation primary/secondary Protective class CE marking UL/cUL (CSA) approval FM approval Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Mains input connections L1, N Connections * Output + * Output Dimensions (W x H x D) in mm Weight Mounting 13 Siemens KT10.1 * 2004 13/7 LOGO!Power LOGO!Power 24 V Overview Application LOGO!Power supplies are primary switched-mode power supplies that are optimized to the LOGO! logic modules in terms of functionality and design. With the wide input range of 85 V to 264 V AC, radio interference level B and assembly option in built-in miniature distribution boards, they can be used universally in a diverse range of applications in the low-end performance range. Technical specifications Power supply, type 24 V/1.3 A 24 V/2.5 A 24 V/4 A Order No. 6EP1 331-1SH02 6EP1 332-1SH42 6EP1 332-1SH51 Input Rated voltage Vin rated Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Single-phase AC 100 to 240 V AC wide-range input 85 to 264 V AC Overvoltage strength 2.3 x Vin rated/1.3 ms 2.3 x Vin rated/1.3 ms 2.3 x Vin rated/1.3 ms Mains buffering at Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25 C) > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 0.7 to 0.35 A < 15 A > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 1.22 to 0.66 A < 30 A > 40 ms at Vin = 187 V 50/60 Hz; 47 to 63 Hz 1.95 to 0.97 A < 30 A I2t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line < 0.8 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C < 3 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C < 2.5 A2s Internal From 16 A Characteristic B or from 10 A Characteristic C Output Rated voltage Vout rated Total tolerance, static * Static mains compensation * Static load compensation Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 1.5 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 1.5 % Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 1.5 % Residual ripple (clock frequency approx. 90 kHz) Spikes (bandwidth approx. 20 MHz) Setting range Status display < 200 mVpp < 200 mVpp < 200 mVpp < 300 mVpp 22.2 to 26.4 V Green LED for output voltage OK No overshoot of Vout (soft start) < 300 mVpp 22.2 to 26.4 V Green LED for output voltage OK No overshoot of Vout (soft start) < 300 mVpp 22.2 to 26.4 V Green LED for output voltage OK No overshoot of Vout (soft start) < 0.5 s/typ. 15 ms 1.3 A 0 to 1.3 A Yes < 0.5 s/typ. 10 ms 2.5 A 0 to 2.5 A Yes < 0.5 s/typ. 35 ms 4A 0 to 4 A Yes Voltage range Power ON/OFF behavior 13 Starting delay/voltage rise Rated current Iout rated Current range up to +55 C Parallel connection for increased output Continued on page 13/9. 13/8 Siemens KT10.1 * 2004 LOGO!Power LOGO!Power 24 V Power supply, type 24 V/1.3 A 24 V/2.5 A 24 V/4 A Order No. 6EP1 331-1SH02 6EP1 332-1SH42 6EP1 332-1SH51 Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated typ. 82 % typ. 7 W typ. 87 % typ. 9 W typ. 89 % typ. 12 W < 0.2 % Vout < 0.2 % Vout < 0.2 % Vout 1.5 % Vout 1.5 % Vout 1.5 % Vout Settling time * Load step from 10 to 90 % * Load step from 90 to 10 % typ. 20 ms typ. 20 ms typ. 20 ms typ. 20 ms typ. 20 ms typ. 20 ms Protection and monitoring Current limitation Short-circuit protection RMS sustained short-circuit current Overload/short-circuit indicator typ. 2 A Stabilized current characteristic <4A - typ. 3.4 A Stabilized current characteristic <8A - typ. 4.7 A Stabilized current characteristic < 10 A - Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2), File E197259; cURus recognized (UL 60950, CSA 22.2), File E151273 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2), File E197259; cURus recognized (UL 60950, CSA 22.2), File E151273 Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178 Class II (without PE conductor) Yes Yes, cULus listed (UL 508, CSA 22.2), File E197259; cURus recognized (UL 60950, CSA 22.2), File E151273 Yes, Class I Div. 2, Group A, B, C, D T4 Yes, GL, ABS IP20 Available soon Appr. for use in marine vessels Degree of protection (EN 60529) Yes, Class I Div. 2, Group A, B, C, D T4 Yes, GL, ABS IP20 EMC Interference emission Line harmonics limitation Interference immunity EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B EN 61000-3-2 EN 61000-6-2 -20 to +55 C with natural convection -40 to +70 C -20 to +55 C with natural convection -40 to +70 C -20 to +55 C with natural convection -40 to +70 C Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals each for 0.5 to 2.5 mm2 2 screw-type terminals each for 0.5 to 2.5 mm2 2 screw-type terminals each for 0.5 to 2.5 mm2 54 x 90 x 55 Approx. 0.17 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 72 x 90 x 55 Approx. 0.25 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 90 x 90 x 55 Approx. 0.34 kg Snap-mounting on DIN rail EN 50022-35x15/7.5 Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 10/90/10 %) Safety Galvanic isolation primary/secondary Protective class CE marking UL/cUL (CSA) approval FM approval Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating Mechanical specifications Mains input connections L1, N Connections * Output + * Output Dimensions (W x H x D) in mm Weight Mounting Yes, ABS IP20 13 Siemens KT10.1 * 2004 13/9 LOGO!Power Notes 13 13/10 Siemens KT10.1 * 2004 Technical information and configuration 14 14/2 14/2 14/5 14/9 SITOP 14/10 L+ Load M 14/11 14/12 SITOP 14/14 L+ M G_KT01_EN_00017 14/15 14/15 Power supplies general Stabilized DC power supplies Mains specifications, line-side connection Possible system disturbances and causes Mounting, mounting areas and fixing options Planning aids Parallel connection for redundant operation and performance enhancement Series connection to increase the voltage Battery charging Fusing of the output circuit, selectivity Siemens KT10.1 * 2004 Technical information and configuration Power supplies general Power supplies In plant construction or mechanical engineering, or in any other situations in which electrical controls are used, a safe and reliable power supply is needed to supply the process with power. The functional reliability of electronic controls and therefore the reliable operation of automated installations is extremely closely linked to the resistance of the load power supply to failure. Final control elements as well as input and output modules will only respond to command signals if the power supply is operating reliably. EMC Types of interference Emission (emitted interference) Interference caused by television and radio reception Interference coupling with data lines or power supply cables Immunity (immunity to interference) Faults on the power cable due to switching non-resistive loads such as motors or contactors Static discharge due to lightning strikes Electrostatic discharge through the human body Conducted noise induced by radio frequencies In addition to general requirements such as reliability, particular demands are placed on the electromagnetic compatibility (EMC) of the power supply with reference to the tolerance range of the output voltage as well as its ripple. Important factors that determine problem-free implementation are, in particular: * An input current with a low harmonic content * Low emitted interference and * Adequate immunity (noise immunity) to interference Certain disturbing phenomena General notes on DC power supplies The DC power supply is a static device with one or more inputs and one or more outputs that converts a system of AC voltage and AC current and/or DC voltage and DC current to a system with different values of DC voltage and DC current by means of electromagnetic induction for the purpose of transmitting electrical energy. The type of construction of a DC power supply is usually decided by its intended use. Unstabilized DC power supplies The AC mains voltage is transformed using 50 Hz/60 Hz safety transformers to a protective extra-low voltage and smoothed with down-circuit rectification and capacitor filtering. In the case of unstabilized DC power supplies, the DC output voltage is not stabilized at a specific value, but the value is varied in accordance with the variation in (mains) input voltage and the loading. The ripple is in the Volt range and is dependent on the loading. The value for the ripple is usually specified as a percentage of the DC output voltage level. Unstabilized DC power supplies are characterized by their rugged, uncomplicated design that is limited to the important factors and focussed on a long service life. Line isolation Rectification 50 Hz ~ Filtering + Vout G_KT01_EN_00067 Block diagram of an unstabilized power supply Stabilized DC power supplies 14 Stabilized DC power supplies have electronic regulation circuits that maintain the DC voltage at the output at a specific value with as little variation as possible. Effects such as variation in input voltage or changes in load at the output are electrically compensated in the specified function area. The ripple in the output voltage for stabilized DC power supplies lies in the millivolt range and is mainly dependent on the loading at the outputs. 14/2 Siemens KT10.1 * 2004 Stabilized DC power supplies can be implemented on different functional principles. The most common types of circuit are: * Linear stabilized power supplies * Magnetic voltage stabilizer * Secondary pulsed switched-mode power supplies * Primary pulsed switched-mode power supplies The most suitable principle for a particular application case will depend mainly on the application. The objective is to generate a DC voltage to supply the specific load as inexpensively and as accurately as possible. Technical information and configuration Stabilized DC power supplies Stabilized DC power supplies (continued) The complete transformer comprises two components. The socalled "ferro resonator" and a series connected auxiliary regulation section. The input winding and the resonance winding of the magnetic stabilizer are decoupled to a large extent by means of the air gap. The magnetic stabilizer supplies a well-stabilized AC voltage. This is rectified and filtered. The transformer itself is operated in the saturation range. Linear stabilized power supplies Rectifier Actuator Filtering electrolytic capacitor Transformer Vout Unstabilized mains stabilized Load G_KT01_EN_00177 The magnetic stabilizer technique is reliable and rugged but is also large-volume, heavy and relatively expensive. Block diagram: Linear regulator The linear regulator operates according to a conventional principle. The supply is provided from an AC supply system (one, two or three conductor supply). A transformer is used to adapt it to form the required secondary voltage. The rectified and filtered secondary voltage is converted into a stabilized voltage at the output by a regulation section. The regulation section comprises a final control element and a control amplifier. The difference between the stabilized output voltage and the unstabilized voltage at the filter capacitor is converted into a thermal loss in the final control element. The final control element functions in this case like a rapidly changeable ohmic impedance. The thermal loss that arises in each case is the product of output current and voltage drop over the final control element. This system is extremely adaptable. Even without any further modifications, several output voltages are possible. In the case of multiple outputs, the individual secondary circuits are generated from separate secondary windings of the input transformer. Some applications can only be resolved in accordance with this circuit principle. Especially when highly accurate regulation, minimal residual ripple and fast compensation times are required. The efficiency is, however, poor and the weight and volume are considerable. The linear regulator is therefore only an economical alternative at low power ratings. Advantages: * Simple, well-proven circuit principle * Good to excellent control characteristics * Fast settling time in case of readjustment Stabilized output voltage Vout stabilized Load G_KT01_EN_00178 Block diagram: Magnetic stabilizer Disadvantages: * The ferro resonator is frequency dependent * The power supplies are large and heavy due to the magnetic components Secondary pulsed switched-mode power supplies: Transformer Filtering Secundary Switching switched-mode Rectification transistor regulator Unstabilized mains Vout stabilized Load Control G_KT01_EN_00179 Block diagram: Secondary pulsed switched-mode power supply Isolation from the supply system is implemented in this case with a 50 Hz transformer. Following rectification and filtering, the energy is switched at the output by means of pulsing through a switching transistor in the filtering and storage circuit. Thanks to the transformer at the input, that acts as an excellent filter, the mains pollution is low. The efficiency of this circuit is extremely high. To protect the connected loads, however, care must be taken; in the event of the switching transistor breaking down, the full, unstabilized DC voltage of the filter capacitor will be applied to the output. This danger, however, also exists in the case of linear stabilized power supplies. Magnetic stabilizer Unstabilized mains Advantages: * Good to excellent control characteristics in combination with series connected linear regulators * Significantly better efficiency than a linear regulator alone This concept offers many advantages for power supplies with numerous different output voltages. Disadvantages: * Relatively high weight and large volume due to the 50 Hz transformer * Poor efficiency, heat dissipation problems * Low storage time Ferro resonator The ferro resonator frequently has a linear regulator connected to the output to improve the control accuracy. Secondary pulsed switched-mode regulators are frequently also connected to the output. Advantages: * Simple design and high efficiency * Multiple outputs, also galvanically isolated from one another, are easily implemented by means of several secondary windings * Fewer problems with interference than with primary pulsed switched-mode power supplies Disadvantages: * The 50 Hz transformer makes the power supplies relatively large and heavy * The output ripple (spikes) correspond to those of a primary pulsed switched-mode power supply Siemens KT10.1 * 2004 14/3 14 Technical information and configuration Stabilized DC power supplies Stabilized DC power supplies (continued) Primary pulsed switched-mode power supplies: In other literature, the term SMPS (Switch Mode Power Supply) or primary switched-mode regulator is often used. Single-ended forward converter Vout stabilized Load Unstabilized mains G_KT01_EN_00180 Control Block diagram: Single-ended forward converter The primary switched-mode regulators are available in many different circuit variants. The most important basic circuits are single-ended forward converters, flyback converters, halfbridge converters, full-bridge converters, push-pull converters and resonance converters. The general principle of operation of the primary switched-mode regulator is shown in the block diagram of the single-ended forward converters. The unstabilized supply voltage is first rectified and filtered. The capacitance of the capacitor in the DC link determines the storage time of the power supply on failure of the input voltage. The voltage at the DC link is approximately 320 V DC for a 230 V supply. A single-ended converter is then supplied with this DC voltage and transfers the primary energy through a transformer to the secondary side with the help of a pulse width regulator at a high switching frequency. The switching transistor has low power losses when functioning as a switch, so that the power balance lies between > 70 % and 90 % depending on the output voltage and current. The volume of the transformer is small in comparison with a 50 Hz transformer due to the high switching frequency because the transformer size taking into account the higher switching frequency is smaller. Using modern semiconductors, switching frequencies of 100 kHz and above can be achieved. At excessively high switching frequencies, the switching losses increase, so that in each case a compromise has to be made between a high efficiency and the largest possible switching frequency. In most applications, the switching frequencies lie between 20 kHz and 250 kHz depending on the output power. 14 The voltage from the secondary winding is rectified and filtered. The system deviation at the output is fed back to the primary circuit through an optocoupler. By controlling the pulse width (conducting phase of the switching transistor in the primary circuit), the necessary energy is transferred to the secondary circuit and the output voltage is regulated. During the non-conducting phase of the switching transistor, the transformer is demagnetized through an auxiliary winding. Just enough energy is transferred as is removed at the output. The maximum pulse width for the pulse/pause ratio for these circuits is < 50 %. 14/4 Siemens KT10.1 * 2004 Advantages: * Small magnetic components (transformer, storage reactor, filter) thanks to the high operating frequency * High efficiency thanks to pulse width regulation * Compact equipment units * Forced-air cooling is not necessary up to the kW range * High storage times are possible on mains failure by increasing the capacitance in the DC link * Larger input voltage range is possible Disadvantages: * High cost circuit, many active components * Higher costs for interference suppression * The mechanical design must be in accordance with HF criteria Primary switched-mode power supplies have become more and more popular over the last few years. Especially due to the small size, low weight, high efficiency and excellent price/performance ratio. Summary The most important characteristics of the circuit types described above are summarized in Table 2. Circuit types Comparison Primary criteria switchedmode Secondary switchedmode Linear Magnetic regulator stabilizer Input voltage range Very large Medium Very small Large Regulation speed Medium Medium Very fast Storage time Very long after power failure Long Very short Long Residual rip- Medium ple Medium Very low Medium Very small Slow Power loss Very small Small Large Frame size Very small Medium Very large Large Weight Very light Medium Heavy Very heavy Medium Low Medium Interference Very large suppression costs Comparison criteria for basic circuit variants Technical information and configuration Mains specifications, line-side connection Supply system data When dimensioning and selecting plant components, the mains data, mains conditions and the operating modes must be taken into account for these components. The most important data for a supply system is the rated voltage and rated frequency. These data for the supply system are designated as rated values in accordance with international agreements. Rated voltage and rated frequency Conversion of low-voltage supply systems In the low-voltage range, it is emphasized in IEC 60038 that 220/380 V and 240/415 V voltage values for three-phase electricity supplies have been replaced by a single internationally standardized value of 230/400 V. The tolerances for the rated voltages of the supply systems that were specified for the transition period up to 2003 were intended to ensure that equipment rated for the previous voltages could be operated safely until the end of its service life. Since May 1987, the standard DIN IEC 60038 "IEC rated voltages" has been applicable in the Federal Republic of Germany. The international standard IEC 60038, Edition 6, 1983, "IEC standard voltages" has been included in this standard unmodified. The IEC 60038 standard is the result of an international agreement to reduce the diverse rated voltage values that are in use for electrical supply networks and traction power supplies, load installations and equipment. Year Rated voltage Up to 1987 220 V/380 V Tolerance range -10 % to +10 % From 1988 to 2003 230 V/400 V -10 % to + 6 % From 2003 230 V/400 V -10 % to +10 % Conversion of low-voltage supply systems The IEC recommendations have been implemented as national regulations in the most important countries, as far as the conditions in the country allow. International supply voltages and frequencies in low-voltage supply systems Country Mains voltage Western Europe: Belgium 50 Hz 230/400 - 127-220 V Denmark 50 Hz 230/400 V Germany 50 Hz 230/400 V Finland 50 Hz 230/400-5001) - 6601) V France 50 Hz 127/220 - 230/400 - 5001) - 380/6601) - 525/9101) V Greece 50 Hz 230/400 - 127/2202) V Great Britain 50 Hz (230/400 V)3) Ireland 50 Hz 230/400 V Iceland 50 Hz 127/2202) - 230/400 V Italy 50 Hz 127/220 - 230/400 V Luxembourg 50 Hz 230/400 V Netherlands 50 Hz 230/400 - 6601) V Northern Ireland 50 Hz 230/400 - Belfast 220/380 V Norway 50 Hz 230-230/400-5001) - 6901) V Austria 50 Hz 230/400 - 5001) - 6901) V Portugal 50 Hz 230/400 V Sweden 50 Hz 230/400 V Switzerland 50 Hz 230/400 - 5002) V Spain 50 Hz 230/400 V Eastern Europe Albania 50 Hz 230/400 V Bulgaria 50 Hz 230/400 V Russian Federation 50 Hz 230/400 - 6901) V Croatia 50 Hz 230/400 V Poland 50 Hz 230/400 V Rumania 50 Hz 230/400 V Serbia 50 Hz 230/400 V Slovakia 50 Hz 230/400 - 5001) - 6901) V Slovenia 50 Hz 230/400 V Chechnya 50 Hz 230/400 - 5001) - 6901) V Hungary 50 Hz 230/400 V 14 1) Industry only. 2) No further expansion. 3) From 2003. Siemens KT10.1 * 2004 14/5 Technical information and configuration Mains specifications, line-side connection International supply voltages and frequencies in low-voltage supply systems (continued) Country Mains voltage Middle-East: Afghanistan 50 Hz 220/380 V Bahrain 50 Hz 230/400 V Cyprus 50 Hz 240/415 V Iraq 50 Hz 220/380 V Israel 50 Hz 230/400 V Jordan 50 Hz 220/380 V Kuwait 50 Hz 240/415 V Lebanon 50 Hz 110/190 - 220/380 V Oman 50 Hz 220/380 - 240/415 V Qatar 50 Hz 240/415 V Saudi Arabia 60 Hz 127/220 - 220/380 - 4801) V (220/380 - 240/415 V 50 Hz: remainder only) Syria 50 Hz 115/200 - 220/380 - 4001) V Turkey 50 Hz 220/380 V (parts of Istanbul: 110/190 V) United Arab Emirates (Abu Dhabi; Ajman; Dubai; Fujayrah; Ras al Khaymah; Sharjah; Um al Qaywayn) 50 Hz 220/380 - 240/415 V Yemen (North) 50 Hz 220/380 V Yemen (South) 50 Hz 230/400 V Far East: 14 Bangladesh 50 Hz 230/400 V Burma 50 Hz 230/400 V Peoples Republic of China 50 Hz 127/220 - 220/380 V (in mining: 1140 V) Hong Kong 50 Hz 200/346 V India 50 Hz 220/380 - 230/400 - 240/415 V Indonesia 50 Hz 127/220 - 220/380 - 4001) V Japan 50 Hz 100/200 - 4001) V South Honshu, Shikoku, Kyushu, Hokkaido, North Honshu 60 Hz 110/220 - 4401) V Cambodia 50 Hz 120/208 V - Phnom Penh 220/238 V Korea (North) 60 Hz 220/380 V Korea (South) 60 Hz 100/2002) - 220/380 - 4401) V Malaysia 50 Hz 240/415 V Peoples Republic of Mongolia 50 Hz 220/380 V Pakistan 50 Hz 230/400 V Philippines 60 Hz 110/220 - 440 V Singapore 50 Hz 240/415 V Sri Lanka 50 Hz 230/400 V Taiwan 60 Hz 110/220 - 220 - 440 V Thailand 50 Hz 220/380 V Vietnam 50 Hz 220/380 V North America: Canada 60 Hz 600 - 120/240 - 460 - 575 V USA 60 Hz 120/208 - 120/240 - 277/480 - 6001) V Central America: Bahamas 60 Hz 115/200 - 120/208 V Barbados 50 Hz 110/190 - 120/208 V Belize 60 Hz 110/220 - 220/440 V Costa Rica 60 Hz 120/2082) - 120/240 - 127/220 - 254/4402) - 227/4801) V Dominican Republic 60 Hz 120/208 - 120/240 - 4801) V 1) Industry only. 2) No further expansion. 14/6 Siemens KT10.1 * 2004 Technical information and configuration Mains specifications, line-side connection International supply voltages and frequencies in low-voltage supply systems (continued) Country Mains voltage Central America (continued): Guatemala 60 Hz 120/208 - 120/240 - 127/220 - 277/4801) - 4801) - 5501) V Haiti 50 Hz 220/380 V (Jacmel), 60 Hz 110/220 V Honduras 60 Hz 110/220 - 127/220 - 277/480 V Jamaica 50 Hz 110/220 - 4401) V Cuba 60 Hz 120/240 - 220/380 - 277/4801) - 4401) V Mexico 60 Hz 127/220 - 4401) V Nicaragua 60 Hz 110/220 - 120/240 - 127/220 - 220/440 - 254/401) V Panama 60 Hz 120/2081) - 120/240 - 254/4401) - 277/4801) V Puerto Rico 60 Hz 120/208 - 480 V El Salvador 60 Hz 110/220 - 120/208 - 127/220 - 220/440 - 240/4801) - 254/4401) V Trinidad 60 Hz 110/220 - 120/240 - 230/400 V South America: Argentina 50 Hz 220/380 V Bolivia 60 Hz 220/380 - 480 V, 50 Hz 110/220 - 220/380 V (exception) Brazil 60 Hz 110/220 - 220/440 - 127/220 - 220/380 V Chile 50 Hz 220/380 V Ecuador 60 Hz 120/208 - 127/220 V Guyana 50 Hz 110/220 V (Georgetown), 60 Hz 110/220 - 240/480 V Columbia 60 Hz 110/220 - 150/260 - 440 V Paraguay 60 Hz 220/380 - 220/440 V Peru 60 Hz 220 - 220/380/440 V Surinam 60 Hz 115/230 - 127/220 V Uruguay 50 Hz 220 V Venezuela 60 Hz 120/208 - 120/240 - 208/416 - 240/480 V Africa: Egypt 50 Hz 110/220 - 220/380 V Ethiopia 50 Hz 220/380 V Algeria 50 Hz 127/220 - 220/380 V Angola 50 Hz 220/380 V Benin 50 Hz 220/380 V Ivory Coast 50 Hz 220/380 V Gabon 50 Hz 220/380 V Ghana 50 Hz 127/220 - 220/380 V Guinea 50 Hz 220/380 V Kenya 50 Hz 220/380 V Cameroon 50 Hz 127/220 - 220/380 V Congo 50 Hz 220/380 V Liberia 60 Hz 120/208 - 120/240 V Libya 50 Hz 127/220 2) - 220/380 V Madagascar 50 Hz 127/220 - 220/380 V Malawi 50 Hz 220/380 V Mali 50 Hz 220/380 V Morocco 50 Hz 115/200 - 127/220 - 220/380 - 5001) V Mauritius 50 Hz 240/415 V Mozambique 50 Hz 220/380 V Namibia 50 Hz 220/380 V Niger 50 Hz 220/380 V 14 1) Industry only. 2) No further expansion. Siemens KT10.1 * 2004 14/7 Technical information and configuration Mains specifications, line-side connection International supply voltages and frequencies in low-voltage supply systems (continued) Country Mains voltage Africa (continued): Nigeria 50 Hz 220/415 V Rwanda 50 Hz 220/380 V Zambia 50 Hz 220/380 V - 415 - 5501) V Senegal 50 Hz 127/220 - 220/380 V Sierra Leone 50 Hz 220/380 V Somalia 50 Hz 220-220/440 V Sudan 50 Hz 240/415 V South Africa 50 Hz 220/380 - 5001) - 550/9501) V Swaziland 50 Hz 220/380 V Tanzania 50 Hz 230/400 V Togo 50 Hz 127/220 - 220/380 V Tunisia 50 Hz 115/200 - 220/380 V Uganda 50 Hz 240/415 V Zaire 50 Hz 220/380 V Zimbabwe 50 Hz 220/380 V Connection and fusing on the line side All SITOP and LOGO!Power supplies are built-in devices. For installation of the devices, the relevant DIN/VDE specifications or country-specific regulations must be taken into account. The supply voltage must be connected in accordance with VDE 0100 and VDE 0160. On installation, protective gear and isolating gear must be provided for disconnecting the power supply. Power supply units cause a current inrush immediately after application of the input voltage due to charging of the load capacitor; it soon falls back to the rated input current level after a few milliseconds. Aside from the internal impedances of the power supply, the current inrush is largely dependent on the size of the input voltage applied as well as the source impedance of the supply network and the line impedance of the supply line. The maximum current inrush for SITOP power supplies is specified in the applicable technical data. It is important for dimensioning up-circuit protective devices. Single-phase SITOP and LOGO!Power supplies are equipped with internal device protection (fuses). For connection to the 14 1) Industry only. 14/8 Siemens KT10.1 * 2004 supply system, only one protective device (fuse or circuitbreaker) must be provided for conductor protection in accordance with the current rating of the installed cable. The circuitbreakers recommended in the data sheets and operating instructions have been selected such that even during the maximum current inrush that can occur under worst case conditions on switching on the supply voltage, the circuit-breaker will not trip. Three-phase SITOP power supplies do not have internal device protection. The up-circuit protective device (three-phase coupled miniature circuit-breaker or motor protection switch) protects the cables and devices. The protective devices specified in the data sheets and operating instructions are optimized to the characteristics of the relevant power supplies. Technical information and configuration Possible system disturbances and causes Overview The quality of the mains voltage has become a decisive factor in the functioning, reliability, maintenance costs and service life of highly sensitive electronic installations and devices (computers, industrial controls, instrumentation, etc.). Mains disturbances cause system failures and affect the function of plants as well as electronic consumers. They can also result in total failure of the installation or equipment. The most frequent types of disturbance are: * Long-term overvoltages * Long-term undervoltages * Burst interference and transients * Voltage reduction and surges * Electrical noise * Momentary mains breaks * Long-term mains breaks Mains disturbances can be caused by a number of things, e.g.: * Switching operations in the supply system * Long cable paths in the supply system * Environmental influences, such as storms * Mains overloads Typical causes of mains disturbances generated in-house are: * Thyristor-controlled drives * Lifts, air-conditioning, photocopiers * Motors, power factor correction equipment * Electrical welding, large machines * Switching of lighting equipment Disturbances in mains voltages can occur individually or in combination. Possible reasons for these disturbances and reactions can be: Mains disturbances Percentage of total disturbance Effect Overvoltage Over a long period, the mains voltage is exceeded by more than +6% (acc. to DIN IEC 60038) approx. 15% - 20% Can result in overheating and even thermal destruction of individual components. Causes total failure. Undervoltage Over a long period, the mains voltage is reduced by more than 10% (acc. to DIN IEC 60038) approx. 20% - 30% Can result in undefined operating states for loads. Causes data errors. Burst interference Energy-rich impulses (e.g. 700 V/1 ms) and energypoor transients (e.g. 2500 V/20 s) result from switching operations in the supply system approx. 30% - 35% Can result in undefined operating states for the loads and can lead to the destruction of components. Voltage reduction and surges The voltage level changes suddenly and in an uncontrolled manner, e.g. due to changes in loading and long cable runs approx. 15% - 30% Can result in undefined operating states and destruction of components. Causes data errors. Electrical noise A mix of frequencies superimposed on the mains due to bad grounding and/or strong HF emitters, such as television transmitters or storms approx. 20% - 35% Can result in undefined operating states for loads. Causes data errors. Voltage interruption Short-term interruption of the mains voltage (up to 10 ms), due to short-circuiting in neighboring supply systems or starting of large electrical machines approx. 8% - 10% Can result in undefined operating states for loads especially those with insufficient mains buffering. Causes data errors. Voltage interruption Long interruption of the mains voltage (longer than 10 ms) approx. 2% - 5% Can result in undefined operating states for loads especially those with insufficient mains buffering. Causes data errors. Mains disturbances and effects The SITOP product family offers a range of possibilities for minimizing or preventing the risk of mains disturbances at the planning stage. 14 Siemens KT10.1 * 2004 14/9 Technical information and configuration Mounting, Mounting areas and fixing options Mounting All SITOP and LOGO!Power supplies are built-in devices. With the exception of the variants with IP65 degree of protection, the power supplies must be mounted vertically so that the air can enter the ventilation slots at the bottom of the devices and leave through the upper part of the devices. If the units are not mounted vertically (at your own risk), the ambient temperature should not exceed +45 C and the load current should not exceed approx. 50% of the rated current value. Variants with IP65 degree of protection can be mounted in any mounting position. The minimum distances specified in the corresponding operating manual for the top, bottom, and side of the devices must be observed to ensure free air convection. Mounting areas and fixing options Power supply Order No. Required mounting area in mm (W x H) Mounting on a standard rail acc. to DIN EN 50022 35 x 7.5 mm 35 x 15 mm Wall mounting SITOP power 24 V, one-phase and two-phase power supplies 24 V/0.5 A 6EP1331-2BA10 22.5 x 180 X X 24 V/0.375 A 6EP1731-2BA00 22.5 x 180 X X 24 V/2 A 6EP1331-2BA00 50 x 225 X 6ES7307-1BA00-0AA0 50 x 205 1) 6ES7305-1BA80-0AA0 80 x 225 1) X 6EP1732-0AA00 80 x 235 X X 24 V/2.5 A 6EP1332-1SH12 80 x 335 X X 24 V/3.5 A 6EP1332-1SH31 160 x 280 X X 24 V/4 A 6EP1332-1SH22 80 x 335 X X 24 V/5 A 6EP1333-3BA00 70 x 225 X X 6EP1333-2BA00 75 x 225 X X 6EP1333-2AA00 75 x 225 X 6ES7307-1EA00-0AA0 80 x 205 1) 6ES7307-1EA80-0AA0 80 x 225 1) 24 V/10 A 24 V/20 A 24 V/40 A X X 6EP1333-1AL12 160 x 230 X X 6EP1334-3BA00 90 x 225 X X 6EP1334-2BA00 100 x 225 X X 6EP1334-2AA00 100 x 225 X X 6EP1334-2CA00 160 x 290 6ES7307-1KA01-0AA0 120 x 205 6EP1334-1AL12 160 x 230 6EP1334-1SH01 200 x 325 6EP1336-3BA00 160 x 225 X X 6EP1336-2BA00 320 x 225 X X X 1) X X X 6EP1536-2AA00 320 x 280 X X 6EP1337-3BA00 240 x 225 X X SITOP power 24 V, three-phase power supplies 14 24 V/10 A 6EP1434-2BA00 320 x 225 X X 24 V/20 A 6EP1436-3BA00 160 x 225 X X 6EP1436-2BA00 320 x 225 X X 24 V/30 A 6EP1437-2BA00 320 x 280 X X 24 V/40 A 6EP1437-3BA00 240 x 225 X X 6EP1437-2BA10 320 x 280 X X SITOP power 24 V, uninterruptible power supplies DC UPS 6 A (with serial interface / USB interface) 6EP1931-2DC21 (-2DC31/-2DC41) 50 x 225 X X DC UPS 15 A (with serial interface / USB interface) 6EP1931-2EC21 (-2EC31/-2EC41) 50 x 225 X X DC UPS 40 A 6EP1931-2FC01 280 x 290 X X 14/10 Siemens KT10.1 * 2004 Technical information and configuration Planning aids Power supply Order No. Required mounting area in mm (W x H) Mounting on a standard rail acc. to DIN EN 50022 35 x 7.5 mm 35 x 15 mm Wall mounting SITOP power 24 V, uninterruptible power supplies Battery module 2.5 Ah 6EP1935-6MD31 285 x 171 X X Battery module 3.2 Ah 6EP1935-6MD11 210 x 171 X X X Battery module 7 Ah 6EP1935-6ME21 206 x 188 X Battery module 12 Ah 6EP1935-6MF01 273 x 138 X X SITOP power 24 V, additional components Buffer module 6EP1961-3BA00 70 x 225 X Redundancy module 6EP1961-3BA20 70 x 225 X X X Diagnosis module 6EP1961-2BA00 72 x 190 X X SITOP power alternative voltages 3-52 V/120 W 6EP1353-2BA00 75 x 225 X X 2 x 15 V/3.5 A 6EP1353-0AA00 75 x 325 X X 48 V/20 A 6EP1457-3BA00 240 x 255 X X SITOP power AS interface 30 V/2.4 A 6EP1632-1AL01 260 x 80 30 V/7 A 6EP1354-1AL01 200 x 325 X 5 V/3 A 6EP1311-1SH02 54 x 130 X X 12 V/1.9 A 6EP1321-1SH02 54 x 130 X X 15 V/1.9 A 6EP1351-1SH02 54 x 130 X X 24 V/1.3 A 6EP1331-1SH02 54 x 130 X X 5 V/6.3 A 6EP1311-1SH12 72 x 130 X X 12 V/4.5 A 6EP1322-1SH02 72 x 130 X X 15 V/4 A 6EP1352-1SH02 72 x 130 X X 24 V/2.5 A 6EP1332-1SH42 72 x 130 X X 24 V/4 A 6EP1332-1SH51 90 x 130 X X X LOGO!Power supplies 1) With an additional mounting adapter. Planning aids For planning and construction, operating manuals with mounting options, dimension drawings, and principle circuits with pin names in different file formats (suitable for CAD applications) are available for download on the Internet. Additional information is available in the Internet under: http://www.siemens.com/automation/sitop 14 Siemens KT10.1 * 2004 14/11 Technical information and configuration Parallel connection for redundant operation and performance enhancement Parallel connection for redundant operation Two SITOP power supplies of the same type can be connected in parallel through diodes for a redundant configuration. Hundred percent redundancy only exists for two power supplies when the total load current is no higher than that which one power supply can supply alone and when the supply for the primary side is also implemented redundantly (i.e. a short-circuit on the primary side will not trigger a shared fuse which would disconnect both power supplies from the mains). SITOP L+ Load M Parallel connection with decoupling diodes for redundant operation is permitted for all SITOP power supplies. The diodes V1 and V2 are used for decoupling. They must have a blocking voltage of at least 40 V and it must be possible to load them with a current equal to or greater than the maximum output current of the respective SITOP power supply. For diode dimensioning, see the following note "General information on selection of diodes". As a simple alternative to diode dimensioning, the prepared add-on module "SITOP modular redundancy module" (Order No. 6EP1961-3BA20, see Section 8) is available for redundant connection of two power supplies. General information on selection of diodes: The diodes must be dimensioned for the maximum dynamic current. This can be the dynamic current during power-up in the short-circuit case or the dynamic current during a short-circuit in operation (the largest of the two values should be taken from the relevant technical specifications). To dissipate the significant power losses of the decoupling diodes (current x diode conductive-state voltage), the diodes must be mounted on suitably dimensioned heat sinks. An additional safety margin is recommended, because the output capacitor integral to the power supply generates an additional peak current in the short-circuit case. This additional current flows only for a few milliseconds which is a period (< 8.3 ms, so-called permissible surge current for diodes) in which diodes are permitted to be loaded with a multiple of the rated current. 14 14/12 Siemens KT10.1 * 2004 SITOP L+ M G_KT01_EN_00017 Parallel connection of two SITOP power supplies for redundant operation Example 1 Two single-phase SITOP modular power supplies with 10 A rated output current (Order No.: 6EP1334-3BA00) are connected in parallel. The dynamic current in the event of a shortcircuit during operation is approx. 30 A for 25 ms. The diodes should therefore have a loading capability of 40 A to be safe, the common heat sink for both diodes must be dimensioned for the maximum possible current of approx. 24 A (RMS sustained short-circuit current) x diode conductive-state voltage. Example 2 Two SITOP power supplies with 40 A rated output current (Order No. 6EP1437-2BA10) are connected in parallel. The dynamic current in the event of a short-circuit during operation is approx. 70 A for 600 ms, the RMS value is < 54 A. The selected diodes should therefore have a loading capability of 100 A to be safe, the heat sink per diode must be dimensioned for the continuous possible current of 54 A x diode conductivestate voltage. Technical information and configuration Parallel connection for redundant operation and performance enhancement Parallel connection for performance enhancement To enhance performance, identical types of most SITOP power supplies can be connected in parallel galvanically (the same principle as parallel connection for redundant operation, but without decoupling diodes): Advantage The costs for mounting the diodes onto heat sinks and the not insignificant power losses of the decoupling diodes (current x diode conducting-state voltage) are avoided. The types permitted for direct galvanic parallel connection are listed in the relevant technical specifications under "Output, parallel connection for performance enhancement". Precondition * The output cables connected to terminals L+ and M of every SITOP power supply should be installed with an identical length and cross-section (or the same impedance) to the common external linking point. * The SITOP power supplies connected in parallel must be switched simultaneously using a common switch in the mains supply line (e.g. using the main switch available in control cabinets). * The output voltages of the power supplies must be measured under no-load operation before they are connected in parallel and are permitted to differ by up to 50 mV. This usually corresponds to the factory default setting. If the output voltage is changed in the case of variable power supplies, the M terminals should first be connected and then the voltage difference between the L+ output terminals measured under no-load conditions before these are connected. This voltage difference must not exceed 50 mV. Note With a direct galvanic connection in parallel of more than two SITOP power supplies, further circuit measures may be necessary for short-circuit and overload protection! Parallel connection for redundant operation and for performance enhancement Almost 100% redundancy Example Using the types permitted for direct galvanic parallel connection (see the relevant technical specifications under "Output, parallel connection for performance enhancement"), the performance can be increased without the need for decoupling diodes and redundancy of almost 100% can be implemented by direct galvanic parallel connection of an additional power supply of the same type to the power supplies required to satisfy the performance requirements. This means that at least one more power supply is required than is necessary for the sum of all load currents. A load current of up to 40 A is required, the power supply must operate on both 400 V and 500 V three-phase supplies (without switch-over). A decoupling diode is normally required for redundancy to ensure that a power supply that has failed as a result of short-circuiting of the outputs (especially as a result of short-circuiting the output electrolytic capacitor) does not also short-circuit the power supply that remains intact. A redundancy of almost 100% can be implemented with this type of circuit. The three-phase 20 A SITOP modular power supply (Order No.: 6EP1436-3BA00) is suitable for this purpose. For load currents up to 40 A, direct galvanic parallel connection of two SITOP modular power 20 supplies is necessary. By connecting another SITOP modular 20 in parallel, performance enhancement and redundancy are implemented simultaneously (if one of the three power supplies fails to supply an output voltage, the remaining two 20 A power supplies are capable of supplying a total load current of 40 A). Note With a direct galvanic connection in parallel of more than two SITOP power supplies, further circuit measures may be necessary for short-circuit and overload protection! 14 Siemens KT10.1 * 2004 14/13 Technical information and configuration Series connection to increase the voltage Series connection to increase the voltage To generate a load voltage of e.g. 48 V DC, two 24 V SITOP power supplies of the same type can be connected in series. The SITOP outputs L+ and M are isolated up to at least 60 V DC against PE (air gaps and creepage distances as well as radio interference suppression capacitors on L+ and M against PE), so that with this type of series connection (see Figure), the following points can be earthed: * M of the lower power supply (results in +48 V DC against PE) * Midway M/L+ between both power supplies (results in 24 V DC against PE) * L+ of the upper power supply (results in - 48 V DC against PE) SITOP L+ M Load SITOP L+ Note: If two devices are connected in parallel, it cannot be guaranteed that the voltage will remain below maximum permissible SELV voltage of 60 V DC in the event of a fault. The purpose of diodes V1 and V2 is to protect the electrolytic output capacitor integrated in the power supply against reverse voltages > 1 V. As a result of the not absolutely simultaneous power-up (even when a common mains switch is used for switching on, differences of a few tens of milliseconds can occur between the various start-up delays), the SITOP power which starts up more quickly supplies current from output L+ to the M output of the slower SITOP power whose output electrolytic capacitor is then theoretically impermissibly discharged. The internal LC filter causes the internal rectifier diode on the secondary side to accept this current a few milliseconds later; this means that the external diode connected with its anode to M and cathode to L+ is essential on each power supply. These diodes are, however, only loaded dynamically, so the 8.3 ms surge current loading capability (specified in the data sheets for suitable diodes) can be used as a basis for dimensioning and it is not usually necessary to cool the diodes using heat sinks. 14 1) We do not accept any liability for this diode recommendation. 14/14 Siemens KT10.1 * 2004 M G_KT01_EN_00059 Series connection: Two SITOP power supplies for doubling the voltage Example: Two single-phase SITOP power supplies with 10 A rated output current (Order No.: 6EP1334-2BA00) should be connected in series to increase the voltage. They supply approximately 38 A dynamically for 200 ms on power-up in the short-circuit case or e.g. also with loads with a high-capacitance input capacitor that momentarily act as a short-circuit at the start. Suitable diodes for V1 and V2 are, for example, of Type SB 340 1) (Schottky diode in axially wired enclosure DO-201AD with approx. 5.3 mm diameter and approx. 9.5 mm length of body). 40 V are permissible as the blocking voltage, and the stationary direct current load capacity IF AV is 3 A. The important dynamic surge current loading capacity IF SM important in this case is sufficient for the selected SITOP power supply (more than 100 A for 8.3 ms). For SITOP power supplies with a low rated output current, this diode can also be used, but is over-dimensioned. * Manufacturer: General Instrument * Distributor: e.g. RS Components, Spoerle Technical information and configuration Battery charging, fusing of the output circuit 24 V DC, selectivity Battery charging with SITOP power supplies The SITOP modular power supplies 5 A to 40 A with stabilized output voltage that can be set between 24.0 V and 28.8 V supply a constant output current of approximately 1.2 x rated current under overload conditions (e.g. a completely discharged 24 V lead-acid battery). In the case of a V/I characteristic set for parallel operation, the battery will be charged with a constant current until approximately 95% of the set SITOP output voltage has been achieved. The charging current is then continuously reduced from 1.2 x rated current at 95% of the set voltage to approx. 0 A or the self-discharge current of the battery at 100% of the set output voltage, i.e. resistance characteristic in this range. As reverse voltage protection and polarity reversal protection, we recommend that a diode suitable for at least 1.2 x rated current of the power supply with a blocking voltage of at least 40 V is connected in series with the + output (anode connected to + output of the SITOP modular and cathode connected to positive pole of the battery). General note for using SITOP power supplies as a battery charging unit When SITOP modular is used as a battery charging unit, the regulations of VDE 0510 or the relevant national regulations must be observed and adequate ventilation must be provided. The SITOP modular power supplies are designed as rack-mounting units, and protection against electric shock should therefore be provided by installation in an appropriate housing. The value recommended by the battery manufacturer must be set as the end-of-charge voltage (depending on the battery temperature). An ideal temperature for the lead-acid battery is between +20 and 30 C and the recommended end-of-charge voltage in this case is usually about 27 V. The output voltage of the power supply must be set at no-load to the end-of-charge voltage plus the voltage drop at the diode. For an end-of-charge voltage of e.g. 27.0 V DC (usual at 20 C to 30 C battery temperature; in each case, compliance with the specifications of the battery manufacturer must be observed!) and 0.8 V voltage drop at the diode, SITOP modular must be set to 27.8 V during no-load operation. Fusing of 24 V power supply circuits and selectivity With unstabilized rectifiers (power transformer equipped with rectifier) the output usually had to be protected with a suitable fuse so that its rectifier diodes would not fail in the event of an overload or a short-circuit (this would destroy the DC loads due to the resulting alternating voltage and lead to serious damage in most cases). On the other hand, the stabilized SITOP power supplies comply with the standard applicable to the electrical equipment of machines DIN VDE 0113 Part 1, Section 7.2.9 (November 1998) or EN 60204-1 and are provided with integral electronic shortcircuit protection which automatically protects both the power supply and the supplied 24 V DC circuits against an excess current in the event of an overload/short-circuit. A differentiation must be made between the following three cases with respect to fusing on the secondary side: Example 1: No fusing Fusing the secondary side (24 V DC) for protecting the load circuits and lines is not required if the respective cross-sections are selected for the maximum possible output current RMS value. Depending on the event (short-circuit or overload) this may either be the short-circuit RMS value or the current limitation value. Example SITOP power 10 (Order No.: 6EP1334-2BA00) * Rated current 10 A * Current limitation typ. 13 to 15 A * Short-circuit RMS value < 21 A The technical specifications usually specify typical values, maximum values are approx. 2 A above the typical value. In the example here, a maximum possible output current RMS value of approx. 23 A must therefore be used for line dimensioning. Example 2: Reduced cross-sections If smaller cross-sections are used than specified in DIN VDE 0113 Part 1 or EN 60204-1, the associated 24 V load supply lines must be provided with appropriate line protection (see DIN VDE 0113 Part 1 or EN 60204-1). Example 3: Selectivity In cases where a load which has failed (e.g. because of a shortcircuit) has to be rapidly detected or where it is essential to selectively switch it off before the power supply enters current limiting mode (with current limiting mode, the voltage would also fall for all remaining 24 V DC loads), there are two possibilities for the secondary side connection. * Use of a 4-channel electronic diagnosis module SITOP select (Order No.: 6EP1961-2BA00), with a current adjustable from 2 A to 10 A for each channel * Series connection of appropriate 24 V DC fuses or circuitbreakers The basis for selection of the 24 V DC fuse or circuit-breaker is the short-circuit current above the rated current which the SITOP power supplies deliver in the event of a short-circuit during operation (values are specified in the respective technical specifications under "Output, dynamic V/I on short-circuit during operation"). It is not easy to calculate the amount of the short-circuit current flowing into the usually not ideal "short-circuit" and the amount flowing into the remaining loads. This depends on the type of overload (high-resistance or low-resistance short-circuit) and the type of load connected (resistive, inductive and capacitive/electronic loads). However, it can be assumed with a first approximation in the average case encountered in practice that the difference of dyn. V/I minus 50% SITOP rated output current is available for the immediate tripping of a circuit-breaker within a typical time of 12 ms (with 14 times the rated DC with a circuit-breaker characteristic C acc. to IEC 898 or with 7 times the rated DC with a circuit-breaker characteristic B or with 5 times the rated DC with a circuit-breaker characteristic A). Please refer to the following tables for circuit-breakers appropriate for selected fusing according to this assumption. It is then unimportant whether the power supply enters current limiting mode (overload) or delivers the maximum short-circuit current (low-resistance short-circuit). The load supply line is in any case protected against an overload by the line protection matched to the conductor cross-section. Siemens KT10.1 * 2004 14/15 14 Technical information and configuration Fusing of the output circuit 24 V DC, selectivity List of ordering data and tripping characteristics of single-pole circuit-breakers 5SY4... acc. to IEC 898/EN 60898 (DIN VDE 0641 Part 11), for use up to 60 V DC (250 V AC, switching capacity 10,000 A) 14 Rated current Tripping characteristic Order No. Range for immediate tripping < 100 ms for operation with direct current (alternating current) Required DC for immediate tripping in < 100 ms Required DC for immediate tripping in approx. 12 ms 1A Type A 5SY4 101-5 DC: 2 to 5 (AC: 2 to 3) x Irated 2 to 5 A DC 5 A DC 1A Type C 5SY4 101-7 DC: 5 to 14 (AC: 5 to 10) x Irated 5 to 14 A DC 14 A DC 1.6 A Type A 5SY4 115-5 DC: 2 to 5 (AC: 2 to 3) x Irated 3.2 to 8 A DC 8 A DC 1.6 A Type C 5SY4 115-7 DC: 5 to 14 (AC: 5 to 10) x Irated 8 to 22.4 A DC 22.4 A DC 2A Type A 5SY4 102-5 DC: 2 to 5 (AC: 2 to 3) x Irated 4 to 10 A DC 10 A DC 2A Type C 5SY4 102-7 DC: 5 to 14 (AC: 5 to 10) x Irated 10 to 28 A DC 28 A DC 3A Type A 5SY4 103-5 DC: 2 to 5 (AC: 2 to 3) x Irated 6 to 15 A DC 15 A DC 3A Type C 5SY4 103-7 DC: 5 to 14 (AC: 5 to 10) x Irated 15 to 42 A DC 42 A DC 4A Type A 5SY4 104-5 DC: 2 to 5 (AC: 2 to 3) x Irated 8 to 20 A DC 20 A DC 4A Type C 5SY4 104-7 DC: 5 to 14 (AC: 5 to 10) x Irated 20 to 56 A DC 56 A DC 6A Type A 5SY4 106-5 DC: 2 to 5 (AC: 2 to 3) x Irated 12 to 30 A DC 30 A DC 6A Type B 5SY4 106-6 DC: 3 to 7 (AC: 3 to 5) x Irated 18 to 42 A DC 42 A DC 6A Type C 5SY4 106-7 DC: 5 to 14 (AC: 5 to 10) x Irated 30 to 84 A DC 84 A DC 8A Type A 5SY4 108-5 DC: 2 to 5 (AC: 2 to 3) x Irated 16 to 40 A DC 40 A DC 8A Type C 5SY4 108-7 DC: 5 to 14 (AC: 5 to 10) x Irated 40 to 112 A DC 112 A DC 10 A Type A 5SY4 110-5 DC: 2 to 5 (AC: 2 to 3) x Irated 20 to 50 A DC 50 A DC 10 A Type B 5SY4 110-6 DC: 3 to 7 (AC: 3 to 5) x Irated 30 to 70 A DC 70 A DC 10 A Type C 5SY4 110-7 DC: 5 to 14 (AC: 5 to 10) x Irated 50 to 140 A DC 140 A DC 13 A Type A 5SY4 113-5 DC: 2 to 5 (AC: 2 to 3) x Irated 26 to 65 A DC 65 A DC 13 A Type B 5SY4 113-6 DC: 3 to 7 (AC: 3 to 5) x Irated 39 to 91 A DC 91 A DC 13 A Type C 5SY4 113-7 DC: 5 to 14 (AC: 5 to 10) x Irated 65 to 182 A DC 182 A DC 16 A Type A 5SY4 116-5 DC: 2 to 5 (AC: 2 to 3) x Irated 32 to 80 A DC 80 A DC 16 A Type B 5SY4 116-6 DC: 3 to 7 (AC: 3 to 5) x Irated 48 to 112 A DC 112 A DC 16 A Type C 5SY4 116-7 DC: 5 to 14 (AC: 5 to 10) x Irated 80 to 224 A DC 224 A DC 14/16 Siemens KT10.1 * 2004 Technical information and configuration Fusing of the output circuit 24 V DC, selectivity Ordering data and tripping characteristics of Siemens single-pole circuit-breaker terminals type 8WA1 011-... Suitable for up to 60 V DC (250 V AC) The following space-saving circuit-breaker terminals for mere short-circuit protection can only be snap-mounted on DIN rail EN 50 022-35x15. They are also available with an auxiliary switch (1 NO contact and 1 NC contact) and feature higher sensitivity than circuit breakers acc. to IEC 898 (EN 60 898), type B. Tripping times/ranges are within narrower tolerances than those of circuit-breakers. When operated with DC, these circuitbreaker terminals do not trip at currents below the rated current, from 1.1 times the rated current, the circuit-breaker terminal may trip after as little as 100 ms. The circuit-breaker rated value must therefore be above the load inrush current peak value. In general, however, the first three milliseconds of the load inrush current may be ignored because no less than 20 to 100 times the rated current is required to trip the circuit-breaker terminals during this period of time. * The circuit-breaker terminals already trip after 40 ms at 1.2 to 1.9 times the rated DC. * The circuit-breaker terminals already trip after 20 ms at 1.7 to 2.6 times the rated DC. * The circuit-breaker terminals already trip after 12 ms at 2.2 to 3.8 times the rated DC. Ordering data and tripping characteristics of Siemens single-pole circuit-breaker terminals type 8WA1 011-... Rated current DC 2A 4A 6A 10 A Order No. (without auxiliary switch) 8WA1 011-1SF25 8WA1 011-1SF26 8WA1 011-1SF27 8WA1 011-1SF28 Order No. (with auxiliary switch 1 NO + 1 NC) 8WA1 011-6SF25 8WA1 011-6SF26 8WA1 011-6SF27 8WA1 011-6SF28 Required DC for immediate tripping in 40 ms 2.4 to 3.8 A 4.8 to 7.6 A 7.2 to 11.4 A 12 to 19 A Required DC for immediate tripping in 20 ms 3.4 to 5.2 A 6.8 to 10.7 A 10.2 to 15.6 A 17 to 26 A Required DC for immediate tripping in approx. 12 ms 4.4 to 7.6 A 8.8 to 15.2 A 13.2 to 22.8 A 22 to 38 A For more data, refer to catalog "Industrial switchgear" (Catalog LV 10) 14 Siemens KT10.1 * 2004 14/17 Technical information and configuration Fusing of the output circuit 24 V DC, selectivity Miniature circuit-breakers in 24 V DC circuits which are powered by SITOP power supply units Technical specifications Type 5A 10 A Order No. 6EP1 333-2BA00/ 6EP1 333-2AA00 6EP1 334-2BA00/ 6EP1 334-2AA00 Input Single-phase Single-phase Rated voltage Vin rated 120/230 V AC 120/230 V AC Output Stabilized, floating direct voltage Stabilized, floating direct voltage Rated voltage Vout rated 24 V DC 24 V DC Rated current Iout rated 5A 10 A Dyn. V/I with short-circuit in operation, typ. 20 A for 350 ms 38 A for 200 ms Tripping of output m.c.b The following are approximately available for selective tripping in practice SITOP, dyn. V/I - 50% Iout rated, typ. 17.5 A for 350 ms CBs to IEC 898, type 5SY4 1.., selectively trippable in approx. 12 ms 1 A Type A (trips at 5 A DC after typ. 12 ms) 1 A Type C (trips at 14 A DC after typ. 12 ms) 1.6 A Typ A (trips at 8 A DC after typ. 12 ms) - 33 A for 200 ms 1.6 A Type C (trips at 22.4 A DC after typ. 12 ms) 2 A Type A (trips at 10 A DC after typ. 12 ms) - 2 A Type C (trips at 28 A DC after typ. 12 ms) 3 A Type A (trips at 15 A DC after typ. 12 ms) Siemens CB terminals, Type 8WA1 011..., selectively trippable in approx. 12 ms - 4 A Type A (trips at 20 A DC after typ. 12 ms) - 6 A Type A (trips at 30 A DC after typ. 12 ms) 2 A Order No. 8WA1 011-1SF25 (trips at 7.6 A DC after max. 12 ms) 4 A Order No. 8WA1 011-1SF26 (trips at 15.2 A DC after max. 12 ms) in 20 ms 14 14/18 Siemens KT10.1 * 2004 - 6 A Order No. 8WA1 011-1SF27 (trips at 22.8 A DC after max. 12 ms) - 10 A Order No. 8WA1 011-1SF28 (trips at 26 A DC after max. 12 ms) Technical information and configuration Fusing of the output circuit 24 V DC, selectivity Miniature circuit-breakers in 24 V DC circuits which are powered by SITOP power supply units Technical specifications Type 5A 10 A Order No. 6EP1 333-3BA00 6EP1 334-3BA00 Input Single-phase, two-phase Single-phase, two-phase Rated voltage Vin rated 120/230-500 V AC 120/230-500 V AC Output Stabilized, floating direct voltage Stabilized, floating direct voltage Rated voltage Vout rated 24 V DC 24 V DC Rated current Iout rated 5A 10 A 30 A for 25 ms Dyn. V/I with short-circuit in operation, typ. 15 A for 25 ms Tripping of output m.c.b The following are approximately available for selective tripping in practice SITOP, dyn. V/I - 50% Iout rated, typ. 12.5 A for 25 ms CBs to IEC 898, type 5SY4 1.., selectively trippable in approx. 12 ms 1 A Type A (trips at 5 A DC after typ. 12 ms) - 25 A for 25 ms 1 A Type C (trips at 14 A DC after typ. 12 ms) 1.6 A Type A (trips at 8 A DC after typ. 12 ms) - 1.6 A Type C (trips at 22.4 A DC after typ. 12 ms) 2 A Type A (trips at 10 A DC after typ. 12 ms) Siemens CB terminals, Type 8WA1 011..., selectively trippable in approx. 12 ms in 20 ms - 3 A Type A (trips at 15 A DC after typ. 12 ms) - 4 A Type A (trips at 20 A DC after typ. 12 ms) 2 A Order No. 8WA1 011-1SF25 (trips at 7.6 A DC after max. 12 ms) - 4 A Order No. 8WA1 011-1SF26 (trips at 15.2 A DC after max. 12 ms) - 6 A Order No. 8WA1 011-1SF27 (trips at 22.8 A DC after max. 12 ms) 4 A Order No. 8WA1 011-1SF26 (trips at 10.7 A DC after max. 20 ms) - 14 Siemens KT10.1 * 2004 14/19 Technical information and configuration Fusing of the output circuit 24 V DC, selectivity Miniature circuit-breakers in 24 V DC circuits which are powered by SITOP power supply units Technical specifications Type 20 A 40 A Order No. 6EP1 436-2BA00 6EP1 437-2BA10 Input Three-phase Single-phase, two-phase Rated voltage Vin rated 400-500 V 3 AC 400-500 V AC Output Stabilized, floating direct voltage Stabilized, floating direct voltage Rated voltage Vout rated 24 V DC 24 V DC Rated current Iout rated 20 A 40 A Dyn. V/I with short-circuit in operation, typ. Approx. 30 A constant current 70 A for 600 ms Tripping of output m.c.b The following are approximately available for selective tripping in practice SITOP, dyn. V/I - 50% Iout rated, typ. 20 A (without interruption) CBs to IEC 898, type 5SY4 1.., selectively trippable in approx. 12 ms 1 A Type A (trips at 5 A DC after typ. 12 ms) 1 A Type C (trips at 14 A DC after typ. 12 ms) 1.6 A Type A (trips at 8 A DC after typ. 12 ms) - 50 A for 600 ms 1.6 A Type C (trips at 22.4 A DC after typ. 12 ms) 2 A Type A (trips at 10 A DC after typ. 12 ms) - 2 A Type C (trips at 28 A DC after typ. 12 ms) 3 A Type A (trips at 15 A DC after typ. 12 ms) - 3 A Type C (trips at 42 A DC after typ. 12 ms) 4 A Type A (trips at 20 A DC after typ. 12 ms) Siemens CB terminals, Type 8WA1 011..., selectively trippable in approx. 12 ms 14 14/20 Siemens KT10.1 * 2004 - 6 A Type A (trips at 30 A DC after typ. 12 ms) - 6 A Type B (trips at 42 A DC after typ. 12 ms) - 8 A Type A (trips at 40 A DC after typ. 12 ms) - 10 A Type A (trips at 50 A DC after typ. 12 ms) 2 A Order No. 8WA1 011-1SF25 (trips at 7.6 A DC after max. 12 ms) 4 A Order No. 8WA1 011-1SF26 (trips at 15.2 A DC after max. 12 ms) - 6 A Order No. 8WA1 011-1SF27 (trips at 22.8 A DC after max. 12 ms) - 10 A Order No. 8WA1 011-1SF28 (trips at 38 A DC after max. 12 ms) Technical information and configuration Fusing of the output circuit 24 V DC, selectivity Miniature circuit-breakers in 24 V DC circuits which are powered by SITOP power supply units Technical specifications Type 20 A 40 A Order No. 6EP1 436-3BA00 (6EP1 336-3BA00) 6EP1 437-3BA00 (6EP1 337-3BA00) Input Three-phase (single-phase) Three-phase (single-phase) Rated voltage Vin rated 400-500 V 3 AC (120/230 V AC) 400-500 V 3 AC (120/230 V AC) Output Stabilized, floating direct voltage Stabilized, floating direct voltage Rated voltage Vout rated 24 V DC 24 V DC Rated current Iout rated 20 A 40 A Dyn. V/I with short-circuit in operation, typ. Approx. 60 A for 25 ms Approx. 120 A for 25 ms Tripping of output m.c.b The following are approximately available for selective tripping in practice SITOP, dyn. V/I - 50% Iout rated, typ. 50 A for 25 ms CBs to IEC 898, type 5SY4 1.., selectively trippable in approx. 12 ms 1 A Type A (trips at 5 A DC after typ. 12 ms) 1 A Type C (trips at 14 A DC after typ. 12 ms) 1.6 A Type A (trips at 8 A DC after typ. 12 ms) 1.6 A Type C (trips at 22.4 A DC after typ. 12 ms) 2 A Type A (trips at 10 A DC after typ. 12 ms) 2 A Type C (trips at 28 A DC after typ. 12 ms) 3 A Type A (trips at 15 A DC after typ. 12 ms) 3 A Type C (trips at 42 A DC after typ. 12 ms) 4 A Type A (trips at 20 A DC after typ. 12 ms) - 100 A for 25 ms 4 A Type C (trips at 56 A DC after typ. 12 ms) 6 A Type A (trips at 30 A DC after typ. 12 ms) 6 A Type B (trips at 42 A DC after typ. 12 ms) - 6 A Type C (trips at 84 A DC after typ. 12 ms) 8 A Type B (trips at 40 A DC after typ. 12 ms) 10 A Type A (trips at 50 A DC after typ. 12 ms) Siemens CB terminals, Type 8WA1 011..., selectively trippable in approx. 12 ms - 10 A Type B (trips at 70 A DC after typ. 12 ms) - 13 A Type A (trips at 65 A DC after typ. 12 ms) - 13 A Type B (trips at 91 A DC after typ. 12 ms) - 16 A Type A (trips at 80 A DC after typ. 12 ms) - 20 A Type A (trips at 100 A DC after typ. 12 ms) 2 A Order No. 8WA1 011-1SF25 (trips at 7.6 A DC after max. 12 ms) 4 A Order No. 8WA1 011-1SF26 (trips at 15.2 A DC after max. 12 ms) 6 A Order No. 8WA1 011-1SF27 (trips at 22.8 A DC after max. 12 ms) 10 A Order No. 8WA1 011-1SF28 (trips at 38 A DC after max. 12 ms) 14 Siemens KT10.1 * 2004 14/21 Technical information and configuration Notes 14 14/22 Siemens KT10.1 * 2004 15 Dimension drawings 15/2 15/9 15/11 SITOP power 129.6 15/13 1 2 3 4 5 15/14 L1 N G_KT01_EN_00072 PE 120V AC L+ M M OK 15/15 SITOP power Single-, two-, three-phase SITOP power Additional components SITOP power Uninterruptible power supplies SITOP power Alternative voltages SITOP power AS interface power supplies LOGO!Power 75 Siemens KT10.1 * 2004 Dimension drawings SITOP power Single-, two-, three-phase Dimensions in mm Order No.: 6EP1 331-2BA10, 6EP1 731-2BA00 7.5 ca 86.6 1 2 3 L1 N PE 1 2 3 80 6EP1331-2BA00 Q6MH 35 SITOP power (L+)(M) (M) 4 5 6 G_KT01_EN_00008 OK 91 22.5 Order No.: 6EP1 331-2BA00 53 - 53.5 50 SITOP power 125 129.6 6EP1331-2BA00 1 2 3 4 5 L1 N G_KT01_EN_00069 PE 120V AC L+ M M OK 124 130 Order No.: 6EP1 331-1SL11, 6ES7 307-1BA00-0AA0 135 50 G_KT01_EN_00106 15 1) For 6ES7 307-1BA00-0AA0 Mounting adapter for DIN rail optional 15/2 Siemens KT10.1 * 2004 36 125 1) Dimension drawings SITOP power Single-, two-, three-phase Dimensions in mm Order No.: 6ES7 305-1BA80-0AA0, 6EP1 333-1SL11, 6ES7 307-1EA00-0AA0, 6ES7 307-1EA80-0AA0 80 135 36 G_KT01_EN_00107 125 1) 1) For 6ES7 305-1BA80-0AA0, 6ES7 307-1EA00-0AA0, 6ES7 307-1EA80-0AA0 Mounting adapter for DIN rail optional Order No.: 6EP1 732-0AA00, 6EP1 332-1SH12, 6EP1 332-1SH22 80 120 36 G_KT01_EN_00070 164 135 149 65 Order No.: 6EP1 332-1SH31 62 G_KT01_EN_00071 67.3 15 3 80 147.4 160 Siemens KT10.1 * 2004 15/3 Dimension drawings SITOP power Single-, two-, three-phase Dimensions in mm Order No.: 6EP1 333-3BA00 120.5 100 1 2 3 4 5 125 SITOP 70 G_KT01_EN_00087 INPUT OUTPUT 4 6 96.5 53 - 53.5 Order No.: 6EP1 333-2BA00, 6EP1 333-2AA00 SITOP 1 2 3 4 5 125 129.6 power L1 N G_KT01_EN_00072 PE 120V AC L+ M M OK 124 130 75 Order No.: 6EP1 333-1AL12, 6EA1 334-1AL12 VOLTAGE SELCTOR 120/230V AC L1 N G_KT01_EN_00090 15 OK Adjust 24-28.8V 1P 24V DC + + + 6.3 15/4 Siemens KT10.1 * 2004 Output: DC24V/5A MAX.OP.TEMP.60C E-Stand 1 2 3 4 5 6 LISTED IND.CONT.EQ 31UB Made inAustria S Q6XXXXXXXX 1 2 3 4 5 6 6EP1 333-1AL12 SITOP power 5 58 130 SITOP power 5 POWER SUPPLY DIN 41752 E230.120 G2 4/10Wg In put: AC120V/230V 60/50Hz 2.4A-1.5A 53.9 160 Dimension drawings SITOP power Single-, two-, three-phase Dimensions in mm Order No.: 6EP1 334-3BA00 120.5 100 1 2 3 4 5 125 SITOP 90 G_KT01_EN_00088 INPUT OUTPUT 4 6 96.5 Order No.: 6EP1 334-2BA00, 6EP1 334-2AA00 SITOP power 129.6 6EP1334-2AA00 1 2 3 4 5 L1 N G_KT01_EN_00075 PE 120V AC L+ M M OK 100 Order No.: 6EP1 334-1SL12, 6ES7 307-1KA01-0AA0, 6EP1 334-1SH01 135 200 (120 1) ) power 10 1) 6ES7 307-1KA01-0AA0 and 6EP1 334-1SL12 2) For 6ES7 307-1KA01-0AA0 Mounting adapter for DIN rail optional 15 36 SITOP G_KT01_EN_00108 125 VOLTAGE SELECTOR 2) Siemens KT10.1 * 2004 15/5 Dimension drawings SITOP power Single-, two-, three-phase Dimensions in mm Order No.: 6EP1 334-2CA00 8.8 133.5 110 53.5 103.5 126.5 197 1) 265 ia. 4 ...10 d 283 10.2 dia. 158.4 1) 5.5 dia . 5.4 134.6 140 145.4 1) Fixing lugs (only in connection with accessory connector seal 6EP1 971-2CA00) G_KT01_EN_00066 22.8 160.5 214 15 15/6 Siemens KT10.1 * 2004 Dimension drawings SITOP power Single-, two-, three-phase Dimensions in mm Order No.: 6EP1 336-3BA00, 6EP1 436-3BA00 120.5 160 AC 120/230 V DC ...V/...A + + ... - ... V - - 24V OK OVERLOAD 50/60Hz N Jump (L2) L1 PE 5 SHUT DOWN 26.87 INPUT OUTPUT G_KT01_EN_00156 125 SITOP s 6.1 Snap-mounting on DIN rail DIN EN 50022-35x15/7.5 Order No.: 6EP1 337-3BA00, 6EP1 437-3BA00 120.5 240 DC 24V/40A + + - - 24V OK OVERLOAD SHUT DOWN L1 L2 50/60Hz L3 PE 26.87 AC 120/230V 5 INPUT OUTPUT G_KT01_EN_00157 125 SITOP s 6.1 Snap-mounting on DIN rail DIN EN 50022-35x15/7.5 15 Siemens KT10.1 * 2004 15/7 Dimension drawings SITOP power Single-, two-, three-phase Dimensions in mm Order No.: 6EP1 336-2BA00, 6EP1 434-2BA00, 6EP1 436-2BA00 92 9 280 L2 L3 3-ph. 400V - 500V AC PE 53 - 53.5 L1 50 / 60 Hz L2 INPUT L3 PE 125 3-ph. 400V - 500V AC 6EP1 436-2BA00 1 2 3 4 5 6 OUTPUT 22,8V - 26,4V CAUTION ! READ INSTRUCTION MANUAL ! 24V DC / 20A L+ M M OK - Adjust + 24V - 26,4V 6.2 L1 power G_KT01_EN_00079 SITOP Order No.: 6EP1 536-2AA00, 6EP1 437-2BA00, 6EP1 437-2BA10 92 280 8.8 L2 L3 3-ph. 400V - 500V AC PE 53 - 53.5 L1 50 / 60 Hz INPUT SITOP 22,8V - 26,4V CAUTION ! READ INSTRUCTION MANUAL ! OK - Adjust + 22,8V - 26,4V 4.9 1 2 3 4 5 6 OUTPUT 24V DC / 40A L+ M M G_KT01_EN_00080 180 power 6.2 15 15/8 Siemens KT10.1 * 2004 Dimension drawings SITOP power Additional components Dimensions in mm Order No.: 6EP1 961-3BA10 Order No.: 6EP1 961-3BA00 116 26 70 120.5 SITOP s 1 2 3 4 5 G_KT01_EN_00060a 125 Q6XX 125 6EP1 961-3BA10 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 6 4 G_KT01_XX_00061 ! Order No.: 6EP1 961-3BA20 Order No.: 6EP1 961-2BA00 70 120.5 G_KT01_EN_00224 125 1 2 3 4 5 80 80 s 6EP1 961-3BA20 9.5 SITOP s G_KT01_XX_00225 G_KT01_EN_00225 71.5 71,5 5 max. 94 max. 94 6 15 Siemens KT10.1 * 2004 15/9 Dimension drawings SITOP power Accessories Dimensions in mm Order No.: 6EP1 971-1AA01 236 50 200 25 159 5.75 G_KT01_EN_00084 135 147.5 25 50 100 Order No.: 6EP1 971-2BA00 25 G_KT01_EN_00085 320 75 6.2 30 320 90 30 28 20 75 10 146 150 13 15 15/10 Siemens KT10.1 * 2004 2 50 100 R 25 280 Dimension drawings SITOP power Uninterruptible power supplies Dimensions in mm Order No.: 6EP1 931-2DC21, 6EP1 931-2DC31, 6EP1 931-2DC41 Order No.: 6EP1 931-2EC21, 6EP1 931-2EC31, 6EP1 931-2EC41 125 125 50 G_KT01_DE_00217 1 2 3 4 5 124 133 Order No.: 6EP1 931-2FC01 220 60 20 52 130 power DC UPS Module 40 G_KT01_EN_00162 27.5 15 Siemens KT10.1 * 2004 15/11 Dimension drawings SITOP power Uninterruptible power supplies Drilling templates Order No.: 6EP1 935-6MD31 Order No.: 6EP1 935-6MD11 174 249 F F + or bl + 84 Attention! Charged battery. Insert fuse F1 on startup (not before). 84 or bl Attention! Charged battery. Insert fuse F1 on startup (not before). After mounting on the rail, the 2 M4 bolts must be tightened. After mounting on the rail, the 2 M4 bolts must be tightened. Before dismounting from the rail, the 2 M4 bolts must be loosened. Before dismounting from the rail, the 2 M4 bolts must be loosened. G_KT01_EN_00005 G_KT01_EN_00004 Order No.: 6EP1 935-6ME21 Order No.: 6EP1 935-6MF01 237 170 F 101 or bl Attention! Charged battery. Insert fuse F1 on startup (not before). + F1 or bl Attention! Charged battery. Insert fuse F1 on startup (not before). 101 + 15A battery fuse F1 only in combination with DC UPS module 15 permissible. 25A battery fuse F1 only in combination with DC UPS module 40 permissible. 25A battery fuse F1 only in combination with DC UPS module 40 permissible. 12 Ah 15A battery fuse F1 only in combination with DC UPS module 15 permissible. G_KT01_EN_00006 15 15/12 Siemens KT10.1 * 2004 G_KT01_EN_00007 Dimension drawings SITOP power Alternative voltages Dimensions in mm Order No.: 6EP1 353-2BA00, 6EP1 353-0AA00 53 - 53.5 75 SITOP 1 2 3 4 5 125 129.6 power L1 N G_KT01_EN_00086 PE 120V AC L+ M M OK 124 130 Order No.: 6EP1 457-3BA00 240 120.5 SITOP s 6EP1 457-3BA00 1 2 3 4 5 125 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII DC 48V/20A + + - - 24V OK OVERLOAD SHUT DOWN L1 L2 L3 50/60Hz PE 26.87 INPUT 3AC 400V - 500V 5 OUTPUT G_KT01_EN_00158 Q6XX 6.1 Snap-mounting on DIN rail DIN EN 50022-35x15/7.5 15 Siemens KT10.1 * 2004 15/13 Dimension drawings SITOP power AS interface power supplies Dimensions in mm Order No.: 6EP1 354-1AL01 135 200 OK VOLTAGE power AS-I 6EP1 354-1AL01 36 SITOP G_KT01_EN_00108 125 SELECTOR Order No.: 6EP1 632-1AL01 1 G_KT01_EN_00138 P30 M30 Shield 6EP1 632-1AL01 1 2 3 4 5 6 1 163 6 175 224 1 Fixing screws: hexagon socket head cap screws M4x16, 8.8 to DIN 912 15 15/14 Siemens KT10.1 * 2004 RD BU BK 14 P30 M30 Shield OUTPUT 30 V/2.8 A 500 80 1 PE 2 P24 3 M24 INPUT 24 V/4.2 A 52 AS-Interface power RUN Dimension drawings LOGO!Power Dimensions in mm Order No.: 6EP1 311-1SH02, 6EP1 321-1SH02, 6EP1 351-1SH02, 6EP1 331-1SH02 72 56 + + Input Output 90 L1 N LOGO!Power G_KT01_DE_00082 24V Order No.: 6EP1 311-1SH12, 6EP1 322-1SH02, 6EP1 352-1SH02, 6EP1 332-1SH42 56 54 + + Input Output 90 L1 N 24V G_KT01_DE_00083 LOGO!Power Order No.: 6EP1 332-1SH51 56 90 L1 N Output 90 Input + + 15 24V G_KT01_DE_00218 LOGO!Power Siemens KT10.1 * 2004 15/15 Dimension drawings Notes 15 15/16 Siemens KT10.1 * 2004 16 Appendix 16/2 SITOP contact persons 16/7 Siemens contacts worldwide 16/8 Service & Support Information and Ordering in the Internet and on CD-ROM 16/9 16/9 16/10 Indexes Order No. index Subject index 16/11 Customer Support 16/14 Conditions of sale and delivery Siemens KT10.1 * 2004 Appendix SITOP contact persons in Europe Austria Bregenz Siemens AG Mr. Madlener Josef-Huter-Str. 6 6901 Bregenz Tel +43 (0) 51 707 682 Fax +43 (0) 51 707 522 Email guenter.madlener @siemens.at Graz Siemens AG Mr. Kroll Straganger Str. 315 8054 Graz Tel +43 (0) 51 707 639 22 Fax +43 (0) 51 707 586 72 Email josef.kroell@siemens.at Innsbruck Siemens AG Mr. Hampel Siemensstr. 24 6063 Rum bei Innsbruck Tel +43 (0) 51 707 673 98 Fax +43 (0) 51 707 549 25 Email johann-georg.hampel @siemens.at Klagenfurt Siemens AG Mr. Weber Werner v. Siemens Park 1 9020 Klagenfurt Tel +43 (0) 51 707 642 43 Fax +43 (0) 51 707 544 18 Email richard.r.weber @siemens.at Linz Siemens AG Mr. Schmidt Wolfgang-Pauli-Str. 2 4020 Linz Tel +43 (0) 51 707 652 95 Fax +43 (0) 51 707 596 01 Email erich.e.schmidt @siemens.at Salzburg Siemens AG Mr. Mariacher Innsbrucker-Bundesstr. 35 5020 Salzburg Tel +43 (0) 51 707 663 50 Fax +43 (0) 51 707 532 29 Email josef.mariacher @siemens.at Vienna Siemens AG Mr. Strasser Siemensstr. 88-92 1210 Wien Tel +43 (0) 51 707 237 88 Fax +43 (0) 51 707 539 40 Email josef.strasser @siemens.at 16 Belarus Minsk Siemens Mr. Gobecke Ul. Y. Kupaly 25, Off. 304 220030 Minsk Tel +375 (17) 210 03 96 Fax +375 (17) 210 03 95 Email alexander.goebecke @siemens.com 16/2 Siemens KT10.1 * 2004 Belgium Huizingen Mr. De Coninck Predslawinka Str. 11-13 3150 Kiew Tel +32 (2) 536 95 39 Fax +32 (2) 536 23 87 Email geert.de-coninck @siemens.be Bosnia-Herzegovina Sarajevo Siemens d.o.o. Mr. Ganic Dubrovacka 6 71000 Sarajevo Tel +387 (33) 27 66 41 Fax +387 (33) 27 66 12 79 Email sadudin.ganic @siemens.ba Bulgaria Sofia Siemens Mrs. Boykova Nikola Vaptzarov Boulevard 1407 Sofia Tel +359 (2) 965 96 24 Fax +359 (2) 965 96 62 Email simatic.service @siemens.bg Croatia Zagreb Mrs. Ilic Heinzelova 70a 10000 Zagreb Tel +385 (1) 6105 337 Fax +385 (1) 6105 621 Email ivana.ilic@siemens.com Czech Republic Brno Siemens s.r.o. Mr. Bocek Technicka 15 61600 Brno Tel +420 (5) 4119 1731 Fax +420 (5) 4119 1749 Email petr.bocek@siemens.com Prague Mr. Pommerl Evropska 33a Praha 6 Tel +420 (2) 3303 2410 Fax +420 (2) 3303 2492 Email werner.poemmerl @siemens.com Denmark Kopenhagen Mr. Limkilde Borupvang 3 2750 Ballerup Tel +45 4477 4883 Fax +45 4477 4002 Email llk@siemens.dk Estonia Tallinn AS Siemens Automation and Drives Mr. Ristoja Parnu mnt. 139 c 11317 Tallinn Tel +372 630 47 51 Fax +372 630 47 31 Email joel.ristoja@siemens.com Finland Helsinki Siemens Oy Automation and Drives Mr. Leppala Majurinkatu 6 02600 Espoo Tel +358 10 511 3463 Fax +358 10 511 3656 Email ari.leppala@siemens.com France Paris Mr. Rouault 39-47, Boulevard Ornano 93527 Saint-Denis CEDEX 2 Tel +33 (1) 4922 9309 Fax +33 (1) 4922 3951 Email jean-marie.rouault @siemens.fr Germany Aachen Siemens AG Mr. Schauenberg Franz-Geuer-Str. 10 50823 Koln Tel +49 (221) 576 2536 Fax +49 (221) 576 2921 Email frank.schauenberg @siemens.com Augsburg Siemens AG Mr. Greis Richard-Strauss-Str. 76 81679 Munchen Tel +49 (89) 9221 3877 Fax +49 (89) 9221 1738 Email wolfgang.greis @siemens.com Bayreuth Siemens AG Mr. Fiedler Von-der-Tann-Str. 30 90439 Nurnberg Tel +49 (911) 654 3413 Fax +49 (911) 654 3596 Email wolfram.fiedler @siemens.com Berlin Siemens AG Mr. Forster Nonnendammallee 72 13629 Berlin Tel +49 (30) 386 32 303 Fax +49 (30) 386 32 543 Email martin.foerster @siemens.com Bielefeld Siemens AG Mr. Knauth Frankfurter Str. 3d 38112 Braunschweig Tel +49 (531) 2712 314 Fax +49 (531) 2712 416 Email bernd.knauth @siemens.com Braunschweig Siemens AG Mr. Knauth Frankfurter Str. 3d 38112 Braunschweig Tel +49 (531) 2712 314 Fax +49 (531) 2712 416 Email bernd.knauth @siemens.com Bremen Siemens AG Mr. Kroger Universitatsallee 16 28359 Bremen Tel +49 (421) 364 2185 Fax +49 (421) 364 2249 Email helmut.kroeger @siemens.com Chemnitz Siemens AG Mr. Forster Nonnendammallee 72 13629 Berlin Tel +49 (30) 386 32 303 Fax +49 (30) 386 32 543 Email martin.foerster @siemens.com Dresden Siemens AG Mr. Forster Nonnendammallee 72 13629 Berlin Tel +49 (30) 386 32 303 Fax +49 (30) 386 32 543 Email martin.foerster @siemens.com Dusseldorf Siemens AG Mr. Schauenberg Franz-Geuer-Str. 10 50823 Koln Tel +49 (221) 576 2536 Fax +49 (221) 576 2921 Email frank.schauenberg @siemens.com Erfurt Siemens AG Mr. Forster Nonnendammallee 72 13629 Berlin Tel +49 (30) 386 32 303 Fax +49 (30) 386 32 543 Email martin.foerster @siemens.com Essen Siemens AG Mr. Poschmann Kruppstr. 16 45128 Essen Tel +49 (201) 816 2148 Fax +49 (201) 816 3621 Email rolf.poschmann @siemens.com Frankfurt Siemens AG Mr. Wulle Dynamostr. 4 68165 Mannheim Tel +49 (621) 465 2661 Fax +49 (621) 465 2747 Email thomas.wulle @siemens.com Freiburg Siemens AG Mr. Roder Weissacher Str. 11 70499 Stuttgart Tel +49 (711) 137 4059 Fax +49 (711) 137 2070 Email bernd.roeder @siemens.com Appendix SITOP contact persons in Europe (continued) Hamburg Siemens AG Mr. Kroger Universitatsallee 16 28359 Bremen Tel +49 (421) 364 2185 Fax +49 (421) 364 2249 Email helmut.kroeger @siemens.com Hannover Siemens AG Mr. Knauth Frankfurter Str. 3d 38112 Braunschweig Tel +49 (531) 2712 314 Fax +49 (531) 2712 416 Email bernd.knauth @siemens.com Heilbronn Siemens AG Mr. Roder Weissacher Str. 11 70499 Stuttgart Tel +49 (711) 137-4059 Fax +49 (711) 137-2070 Email bernd.roeder @siemens.com Karlsruhe Siemens AG Mr. Wulle Dynamostr. 4 68165 Mannheim Tel +49 (621) 465 2661 Fax +49 (621) 465 2747 Email thomas.wulle @siemens.com Kassel Siemens AG Mr. Knauth Frankfurter Str. 3d 38112 Braunschweig Tel +49 (531) 2712 314 Fax +49 (531) 2712 416 Email bernd.knauth @siemens.com Kempten Siemens AG Mr. Greis Richard-Strauss-Str. 76 81679 Munchen Tel +49 (89) 9221 3877 Fax +49 (89) 9221 1738 Email wolfgang.greis @siemens.com Kiel Siemens AG Mr. Kroger Universitatsallee 16 28359 Bremen Tel +49 (421) 364 2185 Fax +49 (421) 364 2249 Email helmut.kroeger @siemens.com Koblenz Siemens AG Mr. Schauenberg Franz-Geuer-Str. 10 50823 Koln Tel +49 (221) 576 2536 Fax +49 (221) 576 2921 Email frank.schauenberg @siemens.com Cologne Siemens AG Mr. Schauenberg Franz-Geuer-Str. 10 50823 Koln Tel +49 (221) 576 2536 Fax +49 (221) 576 2921 Email frank.schauenberg @siemens.com Konstanz Siemens AG Mr. Roder Weissacher Str. 11 70499 Stuttgart Tel +49 (711) 137 4059 Fax +49 (711) 137 2070 Email bernd.roeder @siemens.com Leipzig Siemens AG Mr. Forster Nonnendammallee 72 13629 Berlin Tel +49 (30) 386 32 303 Fax +49 (30) 386 32 543 Email martin.foerster @siemens.com Magdeburg Siemens AG Mr. Knauth Frankfurter Str. 3d 38112 Braunschweig Tel +49 (531) 2712 314 Fax +49 (531) 2712 416 Email bernd.knauth @siemens.com Mannheim Siemens AG Mr. Wulle Dynamostr. 4 68165 Mannheim Tel +49 (621) 465 2661 Fax +49 (621) 465 2747 Email thomas.wulle @siemens.com Munich Siemens AG Mr. Greis Richard-Strauss-Str. 76 81679 Munchen Tel +49 (89) 9221 3877 Fax +49 (89) 9221 1738 Email wolfgang.greis @siemens.com Munster Siemens AG Mr. Poschmann Kruppstr. 16 45128 Essen Tel +49 (201) 816 2148 Fax +49 (201) 816 3621 Email rolf.poschmann @siemens.com Nurnberg Siemens AG Mr. Fiedler Von-der-Tann-Str. 30 90439 Nurnberg Tel +49 (911) 654 3413 Fax +49 (911) 654 3596 Email wolfram.fiedler @siemens.com Osnabruck Siemens AG Mr. Poschmann Kruppstr. 16 45128 Essen Tel +49 (201) 816 2148 Fax +49 (201) 816 3621 Email rolf.poschmann @siemens.com Regensburg Siemens AG Mr. Fiedler Von-der-Tann-Str. 30 90439 Nurnberg Tel +49 (911) 654 3413 Fax +49 (911) 654 3596 Email wolfram.fiedler @siemens.com Rostock Siemens AG Mr. Kroger Universitatsallee 16 28359 Bremen Tel +49 (421) 364 2185 Fax +49 (421) 364 2249 Email helmut.kroeger @siemens.com Saarbrucken Siemens AG Mr. Wulle Dynamostr. 4 68165 Mannheim Tel +49 (621) 465 2661 Fax +49 (621) 465 2747 Email thomas.wulle @siemens.com Siegen Siemens AG Mr. Schauenberg Franz-Geuer-Str. 10 50823 Koln Tel +49 (221) 576 2536 Fax +49 (221) 576 2921 Email frank.schauenberg @siemens.com Stuttgart Siemens AG Mr. Roder Weissacher Str. 11 70499 Stuttgart Tel +49 (711) 137 4059 Fax +49 (711) 137 2070 Email bernd.roeder @siemens.com Trier Siemens AG Mr. Wulle Dynamostr. 4 68165 Mannheim Tel +49 (621) 465 2661 Fax +49 (621) 465 2747 Email thomas.wulle @siemens.com Ulm Siemens AG Mr. Roder Weissacher Str. 11 70499 Stuttgart Tel +49 (711) 137 4059 Fax +49 (711) 137 2070 Email bernd.roeder @siemens.com Weingarten Siemens AG Mr. Roder Weissacher Str. 11 70499 Stuttgart Tel +49 (711) 137 4059 Fax +49 (711) 137 2070 Email bernd.roeder @siemens.com Wetzlar Siemens AG Mr. Wulle Dynamostr. 4 68165 Mannheim Tel +49 (621) 465 2661 Fax +49 (621) 465 2747 Email thomas.wulle @siemens.com Wurzburg Siemens AG Mr. Fiedler Von-der-Tann-Str. 30 90439 Nurnberg Tel +49 (911) 654 3413 Fax +49 (911) 654 3596 Email wolfram.fiedler @siemens.com Wuppertal Siemens AG Mr. Poschmann Kruppstr. 16 45128 Essen Tel +49 (201) 816 2148 Fax +49 (201) 816 3621 Email rolf.poschmann @siemens.com Great Britain Manchester Mr. Mackrory Sir William Siemens House/ Princess Road Manchester M20 2UR Tel +44 (161) 446 6400 Fax +44 (161) 446 6201 Email john. mackrory @siemens.com Greece Athens Siemens A.E. Mrs. Antoniou Artemidos 8 15110 Amaroussio/Athen Tel +30 (1) 6864 534 Fax +30 (1) 6864 299 Email konstantina.antoniou @siemens.gr Hungary Budapest Mr. Solt Gizella ut 51-57 1143 Budapest Tel +36 (1) 471 1717 Fax +36 (1) 471 1704 Email attila.solt@siemens.hu Ireland Dublin Siemens Ltd. Mr. Feeley Leeson Close 2 Dublin Tel +353 (1) 216 2441 Fax +353 (1) 216 2499 Email martin.feeley @siemens.com Siemens KT10.1 * 2004 16 16/3 Appendix SITOP contact persons in Europe (continued) 16 Italy Bari Mr. Gabellone Via Lucarelli, 10/b 70124 Bari Tel +39 (080) 50 24068 Email luca.gabellone @siemens.it Bologna Mr. Tosatti Via del Gomito, 1 40127 Bologna Tel +39 (051) 63 84509 Email davide.tosatti@siemens.it Bologna Mr. Forghieri Via del Gomito, 1 40127 Bologna Tel +39 (051) 63 84608 Email mauro.forghieri @siemens.it Florence Mr. Vessio Via Odorico da Pordenone, 26 50127 Firenze Tel +39 (055) 3392 201 Email domenico.vessio @siemens.it Milan Mr. Bischetti Viale Piero e Alberto Pirelli 10 20126 Milano Tel +39 (02) 6676 3321 Fax armando.bischetti @siemens.it Milan Mr. Berti Viale Piero e Alberto Pirelli 10 20126 Milano Tel +39 (02) 6676 2836 Email gualtiero.berti @siemens.it Milan Mr. Gaspari Viale Piero e Alberto Pirelli 10 20126 Milano Tel +39 (02) 6676 2067 Email adolfo.gaspari @siemens.it Naples Mr. De Sio Via G. Quagliarello, 35/E 80146 Napoli Tel +39 (081) 5454237 Email maurizio.desio @siemens.it Padova Mr. Millevoi Viale dell'Industria, 19 35129 Padova Tel +39 (049) 8291336 Email piero.millevoi@siemens.it Padova Mr. Maffioli Viale dell'Industria, 19 35129 Padova Tel +39 (049) 8291359 Email andrea.maffioli @siemens.it Rome Mr. D Innocenti Via Laurentina 455 142 Roma Tel +39 (06) 59692 285 Email dario.dinnocenti @siemens.it 16/4 Siemens KT10.1 * 2004 Torino Mr. Montoli Via Pio VII, 127 10127 Torino Tel +39 (011) 6173 275 Email daniele.montoli @siemens.it Latvia Riga Siemens SIA Mr. Tumpelis Vilandes iela 3 1010 Riga Tel +371 (701) 55 18 Fax +371 (701) 55 01 Email ugis.tumpelis @siemens.com Lithuania Vilnius Siemens UAB Mr. Laurinaitis V. Kudirkos g.6 2009 Vilnius Tel +370 (2) 39 1515 Fax +370 (2) 39 1501 Email rimas.laurinaitis @siemens.com Luxembourg Luxembourg Siemens S.A. Mr. Koch 20, rue des Peupliers 2328 Luxembourg-Hamm Tel +352 (43) 8 43-403 Fax +352 (43) 8 43-449 Email edmond.koch @siemens.lu Poznan Sales West Siemens Sp.z o.o. Mr. Kaysiewicz ul. Romana Maya 1 Poznan Sales West Tel +48 (61) 650 2823 Fax +48 (61) 650 2824 Email maciej.kaysiewicz @siemens.com Warsaw Sales East Siemens Sp.z o.o. Mr. Zielinski ul. Zupnicza 11 Warszawa Sales East Tel +48 (22) 870 9862 Fax +48 (22) 870 9119 Email andrzej.zielinski @siemens.pl Warsaw Siemens Sp.z o.o. Mr. Ciuk ul. Zupnicza 11 3821 Warszawa Tel +48 (22) 870 9145 Fax +48 (22) 870 9169 Email andrzej.ciuk @siemens.com Portugal Amadora Siemens S. A. Mr. Filipe Rua Irmaos de Siemens, 1 2720093 Amadora Tel +351 (21) 417 8838 Fax +351 (21) 417 8050 Email sergio.filipe @lis1.siemens.pt Netherlands The Hague Siemens Nederland N.V. Mr. Nieuwstraten Prinses Beatrixlaan 800 2595 BN The Hague Tel +31 70 333 32 74 Fax +31 70 333 38 85 Email anton.nieuwstraten @siemens.nl Romania Bukarest Siemens S.R.L. Mr. Razvan Calea Pleavei Nr. 139, Corp C, sector 6 RO 77131 Bucuresti Tel +40 2120 77 469 Fax +40 2120 77 462 Email razvan.ioachim @siemens.com Norway Oslo Mr. Otterstad Ostre Aker vei 90 0518 Oslo Tel +47 2263 4164 Fax +47 2263 3390 Email dag.otterstad @siemens.no Russia Moscow Mr. Iwanow Ul. Malaja Kaluzhskaja, 17/19 117071 Moscow Tel +7 (095) 737 2492 Fax +7 (095) 737 2483 Email pawel.iwanow @siemens.com Poland Gdansk Sales North Siemens Sp.z o.o. Mr. Skicki ul. Batorego 28-32 Gdansk Sales North Tel +48 (58) 785 8490 Fax +48 (58) 785 8499 Email andrzej.skicki @siemens.com Katowice Sales South Siemens Sp.z o.o. Mr. Mezydlo ul. Dolnych Walow 7 Katowice Sales South Tel +48 (32) 208 4130 Fax +48 (32) 208 4139 Email tomasz.mezydlo @siemens.com Slovakia Bratislava Siemens s.r.o. Mr. Patoprsty Stromova 9 83796 Bratislava Tel +421 (2) 5968-2426 Fax +421 (2) 5968 5240 Email radomir.patoprsty @siemens.sk Slovenia Ljubljana Siemens d.o.o. Mr. Mlinsek Dunajska 22 1511 Ljubljana Tel +386 (1) 4746-152 Fax +386 (1) 4746-138 Email matjaz.mlinsek @siemens.si Spain Madrid Mr. Ramon Romero Ronda de Europa, 5 Tres Cantos (Madrid) Tel +34 (91) 514 4761 Fax +34 (91) 514 7019 Email pssitop@ssa.siemens.es Sweden Stockholm Siemens AB Mr. Naglitsch Johanneslundsvagen 12-14 Upplands Vasby Tel +46 (8) 728 1872 Fax +46 (8) 728 1290 Email peter.naglitsch @siemens.se Switzerland Basel Siemens Schweiz AG Mr. Gysin Viaduktstr. 40 4051 Basel Tel +41 (0) 848 822 844 Fax +41 (0) 848 822 876 Email rudolf.gysin @siemens.com Lausanne Siemens Suisse SA Mr. Gysin Avenue des Baumettes 5 1020 Renens Tel +41 (0) 848 822 844 Fax +41 (0) 848 822 876 Email rudolf.gysin @siemens.com Zurich Siemens Schweiz AG Mr. Gysin Freilagerstr. 40 8047 Zurich Tel +41 (0) 848 822 844 Fax +41 (0) 848 822 876 Email rudolf.gysin @siemens.com Turkey Istanbul Siemens Sanayi ve Ticaret A.S., Istanbul Mrs. Ynan Yakacik Yolu No. 111 81430 Kartal-Istanbul Tel +90 (216) 459 3706 Fax +90 (216) 459 3079 Email sevtap.inan @siemens.com.tr Appendix SITOP contact persons in Europe (continued) Ukraine Kiew Siemens AG Mr. Fadejew Uliza Worowskowo 27 252054 Kiew 54 Tel +380 (44) 201-2461 Fax +380 (44) 201-2466 Email wladimir.fadejew @siemens.com Yugoslavia Belgrade Siemens d.o.o., Belgrad Mr. Rajic Knez Mihailova 30 11000 Belgrad Tel +381 (11) 3070 184 Fax +381 (11) 3070 050 Email milan.rajic@siemens.com outside Europe Africa Algeria Algier Siemens Algerie S.A.R.L. Mr. Rabah Chaoui 29, rue des pins 16035 Algier Tel +213 21 60 37 65 Tel +213 21 60 72 07 Fax +213 21 48 09 79 Email rabah.chaoui @siemens.com Cote d'Ivoire Abidjan Semen Mr. Hellal Atelier Z.I. Vridi Rue des Petroliers 15 B.P. 1062 Abidjan 15, Semen Tel +225 21 27 16 75 (46 57) Fax +225 21 27 10 21 Email philippehellal@aviso.ci Egypt Cairo Siemens Ltd. Mr. El-Bassyouni 55 A & B, El Nakhil and El Aenab Street Cairo - Mohandessin, NME Tel +20 2 33 33 6 12 Fax +20 2 33 33 6 07 Email tamer.bassyouni @siemens.com Samouha-Alexandria Siemens Limites Mr. Lotfy 27, Victor Emmanuel Street Samouha-Alexandria Tel +20 (3) 4251007 Fax +20 (3) 4251009 Email mina.lotfy@siemens.com Kenya Nairobi International Energy Technik Ltd. Mr. Pillay P.O. Box 46215 Unit 90, The Alpha Centre Mombasa Road Nairobi Tel +254 2 35 1082 Fax +254 2 35 0469 Email rajesh.pillay@iet.co.ke Morocco Casablanca Siemens Marokko S.A. Immeuble Siemens Mr. Mostafa Bazokar km 1 Route de Rabat Ain-Sebaa 20250 Casablanca Tel +212 22 66 92 59 (92 28) Fax +212 22 34 01 51 Email mostafa.bazokar @siemens.com South Africa Johannesburg Siemens SA Control and Instrumentation Siemens Park Midrand Mr. Venter 300 Janadel Avenue Halfway House 1685 Johannesburg - Sudafrika Tel +27 (011) 652 36 88 Fax +27 (011) 652 36 97 Email stephen.venter @siemens.com Tunesia Tuni Faze Service Mr. Fantar Immeuble Nour El Bouhaira E. B. Rue du Lac Turkana Les Berges du Lac 1053 Tuni Tel +216 71 964 266 Fax +216 71 964 265 Email afif.fantar@faze.com.tn America Argentina Buenos Aires Siemens S.A. Mr. Abenante Calle 122 (ex Gral. Roca) 4785, Ruta 8, km 18 - Casilla de Correo 32 RA-B1653 JXA San Martin Prov. de Buenos Aires Tel +54 11 4738 7341 Fax +54 11 4738 7271 Email matias.abenante @siemens.com Brazil Sao Paulo Siemens Ltd. Mr. Marchesan Rua Coronel Bento Bicudo, 111 - Lapa 05069 900 Sao Paulo - SP Tel +55 11 3833 4115 Fax +55 11 3833 4183 Email ricardo.marchesan @siemens.com Canada Ontario Siemens Canada Ltd. Mr. Udayan 80 Walker Drive Brampton, ON L6T 4H6 Tel +1 905 819 5800 (2470) Fax +1 905 819 5719 Email udayan.pandya @siemens.com Chile Santiago de Chile Siemens SA Mercosur Mr. Gorenberg Alameda 194, p3 - Santiago Santiago de Chile Tel +56 2 361 4283 Fax +56 2 361 4293 Email andres.gorenberg @siemens.com Columbia Santafe de Bogota D.C. Siemens S.A. Mr. Mejia Carrera 65 No. 11-83 Santafe de Bogota D.C. Tel +57 (1) 4253 710 Fax +57 (1) 2942 600 Email jorge.mejia @siemens.com Costa Rica San Jose Siemens S.A. San Jose Mr. Blanco La Uruca Apartado: 10022-1000 S.J. San Jose, Costa Rica Tel +506 (287) 5251 Fax +506 (287) 5295 Email sergio.blanco @siemens.com.mx El Salvador San Salvador Mr. Callejas Antiguo Cuscatlan, Apartado 1525 01 137 San Salvador Tel +503 278 3333 Fax +503 278 3334 Email victor.callejas @siemens.com Mexico Colonial Industrial Vallejo Siemens SA Mr. Quintana Poniente 116 No. 560 02300 Mexiko, D.F. Tel +525 55 328 20 00 - 3330 Fax +525 55 328 20 00 - 2097 Email edgar.quintana @siemens.com Colonial Industrial Vallejo Siemens SA Mr. Sanchez Poniente 116 No. 560 Colonial Industrial Vallejo Tel +52 (5) 328-2112 Fax +52 (5) 328-2097 Email gregorio.sanchez @siemens.com Peru Lima Siemens Mr. Balarezo Av. Domingo Orue 971, Surquillo Lima Tel +51 (1) 2150030 (4354) Fax +51 (1) 42 19 292 Email jesus.balarezo @siemens.com USA Norcross Siemens SE&A Mr. Bronzel 5300 Triangle Parkway 30092-2538 Norcross, GA Tel +001 (770) 871 3946 Fax +001 (770) 871 3996 Email kai-uwe.bronzel @siemens.com Venezuela Caracas Siemens s.a. Mr. Cavada Av. Don Diego Disneros (1010-A-Aptdo. 3616) =Pf Urbanizacion, Los Ruices Caracas 1071 Tel +58 (2) 203 8436 Fax +58 (2) 203 8523 Email jesus.cavada @siemens.com Guatemala Ciudad de Guatemala Siemens S.A. Mr. Godoy 2a. Calle 6-76, Zona 10 Ciudad de Guatemala Tel +502 379 2333 Fax +502 379 2318 Email miguel.godoy @siemens.com 16 Siemens KT10.1 * 2004 16/5 Appendix SITOP contact persons outside Europe (continued) Asia China Beijing Siemens Limited Mr. Shi 7, Wangjing Zhonghuan Nanlu 100015 Beijing Tel +86 (10) 6472 1888 (3374) Fax +86 (10) 6473 9213 Email lin.shi@siemens.com Beijing Siemens Limited Mr. Deng 7, Wangjing Zhonghuan Nanlu 100015 Beijing Tel +86 (10) 6472 1888 (3903) Fax +86 (10) 6473 9213 Email xu.deng@siemens.com Hong Kong Siemens Ltd. Mr. Lam 58/F, Central Plaza, 18 Harbour Road Wanchai, Hong Kong Tel +86 (852) 2583 3228 Fax +86 (852) 2824 9196 Email jacky.lam@siemens.com India Thane Siemens Limited Mr. Karmile Kalwa Works, Thane Belapur Road 400 601 Thane (Maharashtra) Indonesia Jakarta P.T. Siemens Indonesia Mr. Ansori Jalan Jendral Ahmad Yani Kav. B 67-68 Pulo Mas 13210 Jakarta Tel +62 (21) 4729-348 Fax +62 (21) 4729-300 Email ato.ansori@siemens.com Iran Theran Siemens Sherkate Sahami (Khass) Mr. Jashni Avenue Ayatollah Taleghani 32 15936 Theran Tel +9821 6142234 Fax +9821 6460615 Email yousef.jashni @siemens.com Israel Tel-Aviv ARDAN Production & Industrial Control Ltd. Mr. Bauer 32, Habanay Street Holon 58856 Tel +972 (3) 6 50 70 00 Fax +972 (3) 5 58 13 11 Email bauer@ardan-pic.co.il 16 Japan Shinagawa-ku, Tokyo Siemens K.K. Mr. Ishida 20-14, Higashi-Gotanda 3chome 141-8614 Shinagawa-ku, Tokyo Tel +81 (3) 5423 8594 Fax +81 (3) 5423 8734 Email toshikazu.ishida @siemens.com Pakistan Karachi Siemens Pakistan Engineering Co. Ltd. Mr. Naukhez B-72, Estate Avenue, S.I.T.E. 75700 Karachi Tel +92 (21) 2574 910 19-4387 Fax +92 (21) 256 3563 Email naukhez.arslan@ siemens.com Vietnam Hanoi Siemens AG Mr. Phuong 239 Xuan Thuy Road, Cau Giay District Hanoi Tel +84 (4) 8334 400 Fax +84 (4) 8334 371 Email nguyen-ngoc.phuong @siemens.com Jordan Amman F.A. Kettaneh & Co.Ltd. Mr. Rami Al Quds Street, P.O. Box 485 11118 Amman Tel +962 (6) 439 8642/7173 Fax +962 (6) 439 2582 Email al-naqa.rami @kettaneh.com.jo Philippines Makati City Siemens Inc. Mr. Salud 169 H.V. De la Costa Street, Salcedo Village 1227 Makati City Tel +63 (2) 814 9678 Fax +63 (2) 814 9894 Email bernard.salud @siemens.com Australia Lebanon Mar-Mikhael-Beirut Kettaneh S.A. Mr. Markarian Nahr Street Mar-Mikhael- Beirut Tel 00961 1 444560/3 Fax 00961 1 4446284 Email avedis.markarian @kettaneh.com Kazakhstan Almaty Siemens TOO Mr. Kokoulin 20, Zharokov St. 480008 Almaty Tel +73 272 597 828 Fax +73 272 583 700 Email andrej.kokoulin @siemens.com Kuwait Sharq Siemens Mr. Chhabra Jaber Al-Mubarak Street, Block 4 Sharq, Kuwait Tel 965 241 8888 Fax 965 246 3222 Email naukhez.arslan @siemens.com Korea Seoul Siemens Limited Mr. Song 726, Asia Building 10th floor Yeoksam-dong, Kangnam-gu 135 925 Seoul Tel +82 (2) 3420 4897 Fax +82 (2) 527 7785 Email songss@siemens.com Malaysia Kuala Lumpur Mrs. Leong 11 section 16/11, Jalan Damansara 46350 Petaling Jaya, Selangor Darul Ehsan Tel +60 (3) 7952 5363 Fax +60 (3) 7955 2282 Email therese.leong @siemens.com Further information on contact person's adresses can be found in the Internet under http//www.siemens.com/automation/partner 16/6 Siemens KT10.1 * 2004 Saudi Arabia Jeddah Siemens Ltd. Mr. Vhora Baladia/Binzager Street Jeddah 21412 Tel +966 (2) 661-4444 (2069) Fax +966 (2) 661-4444 (1500) Email abdulhafiz.vhora @siemens.com Thailand Bangkok Siemens Mr. Somchai 2922/283 New Petchburi Road, Bangkapi, Huay Kwang 10310 Bangkok Tel +66 2715 4850 Fax +66 2715 4841 Email somchaij@siemens.com Taiwan Taipei Siemens Mr. Gu 3, Yuan Qu Street, Nan Gang District 115 Taipei Tel +886 (2) 2652 8888 Fax +886 (2) 2652 8948 Email ginfu.gu @siemens.com Uzbekistan Taschkent Siemens AG Mr. Dobrev K. Yarmatov Str. 6 Taschkent Tel +998 (71) 120 6403 Fax +998 (71) 120 6402 Email evgeniy.dobrev @siemens.com Bayswater Victoria Siemens Limited Mr. Avellino 885 Mountain Highway 3153 Bayswater Victoria Tel +61 3 9721 7592 Fax +61 3 9721 7630 Email mark.avellino @siemens.com Appendix Siemens contacts worldwide At www.siemens.com/automation/partner you can find details of Siemens contact partners worldwide responsible for particular technologies. You can obtain in most cases a contact partner for * Technical Support, * Spare parts/repairs, * Service, * Training, * Sales or * Consultation/engineering. You start by selecting a * Country, * Product or * Sector. By further specifying the remaining criteria you will find exactly the right contact partner with his/her respective expertise. 16 Siemens KT10.1 * 2004 16/7 Appendix Service & Support Information and Ordering in the Internet and on CD-ROM A&D in the WWW A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. The Siemens Automation and Drives Group (A&D) has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address http://www.siemens.com/automation you will find everything you need to know about products, systems and services. Product Selection Using the Interactive Catalog Detailed information together with convenient interactive functions: The interactive catalog CA 01 covers more than 80,000 products and thus provides a full summary of the Siemens Automation and Drives product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the interactive catalog CA 01can be found in the Internet under http://www.siemens.com/automation/ca01 or on CD-ROM or DVD. Easy Shopping with the A&D Mall The A&D Mall is the virtual department store of Siemens AG in the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online via the Internet. Numerous functions are available to support you. For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing. Please visit the A&D Mall on the Internet under: http://www.siemens.com/automation/mall 16 16/8 Siemens KT10.1 * 2004 Appendix Indexes Order No. index Type 5SY4 5SY4... 6EP1 6EP1 311-1SH02 6EP1 311-1SH12 6EP1 321-1SH02 6EP1 322-1SH02 6EP1 331-1SH02 6EP1 331-1SL11 6EP1 331-2BA00 6EP1 331-2BA10 6EP1 332-1SH12 6EP1 332-1SH22 6EP1 332-1SH31 6EP1 332-1SH42 6EP1 332-1SH51 6EP1 333-1AL12 6EP1 333-1SL11 6EP1 333-2AA00 6EP1 333-2BA00 6EP1 333-3BA00 6EP1 334-1AL12 6EP1 334-1SH01 6EP1 334-1SL12 6EP1 334-2AA00 6EP1 334-2BA00 6EP1 334-2CA00 6EP1 334-3BA00 6EP1 336-2BA00 6EP1 336-3BA00 6EP1 337-3BA00 6EP1 351-1SH02 6EP1 352-1SH02 6EP1 353-0AA00 6EP1 353-2BA00 6EP1 354-1AL01 6EP1 434-2BA00 6EP1 436-2BA00 6EP1 436-3BA00 6EP1 437-2BA00 6EP1 437-2BA10 6EP1 437-3BA00 6EP1 457-3BA00 6EP1 536-2AA00 6EP1 632-1AL01 6EP1 731-2BA00 6EP1 732-0AA00 6EP1 931-2DC21 6EP1 931-2DC31 6EP1 931-2DC41 6EP1 931-2EC21 6EP1 931-2EC31 6EP1 931-2EC41 6EP1 931-2FC01 6EP1 935-6MC01 6EP1 935-6MD11 6EP1 935-6MD31 6EP1 935-6ME21 Page 14/16 13/2, 15/15 13/2, 15/15 13/4, 15/15 13/4, 15/15 13/8 , 15/15 2/3, 15/2 2/2, 15/2 2/2, 15/2 3/2, 15/3 3/2, 15/3 3/2, 15/3 13/8, 15/15 13/8, 15/15 4/3, 15/4 4/3, 15/3 4/2, 14/18, 15/4 4/2, 14/18, 15/4 4/2, 7/2, 14/19, 15/4 5/3, 15/4 5/3, 15/5 5/3, 15/5 5/2, 14/18, 15/5 5/2, 14/18, 15/5 5/3, 15/5 5/2, 7/2, 14/19, 15/5 6/3, 15/8 6/2, 15/7 6/2, 15/7 13/6, 15/15 13/6, 15/15 10/2, 15/13 10/2, 15/13 11/2, 15/14 7/6, 15/8 7/6, 14/20, 15/8 7/3, 14/21, 15/7 7/7, 14/20, 15/8 7/7, 15/8 7/3, 14/21, 15/7 10/2, 15/13 6/3, 15/8 11/2, 15/14 2/2, 15/2 2/3, 15/3 9/7, 15/11 9/7, 15/11 9/7, 15/11 9/9, 15/11 9/9, 15/11 9/9, 15/11 9/13, 15/11 9/14 9/16, 15/12 9/15, 15/12 9/17, 15/12 Type 6EP1 6EP1 935-6MF01 6EP1 961-2BA00 6EP1 961-3BA00 6EP1 961-3BA10 6EP1 961-3BA20 6EP1 971-1AA01 6EP1 971-2BA00 6ES7 6ES7 305-1BA80-0AA0 6ES7 307-1KA01-0AA 6ES7 307-1BA00-0AA0 6ES7 307-1EA00-0AA0 6ES7 307-1EA80-0AA0 Page 9/18, 15/12 8/4, 15/9 8/2, 15/9 8/2, 15/9 8/2, 15/9 8/6, 15/10 8/6, 15/10 2/3, 15/3 5/3, 15/5 2/3, 15/2 4/3, 15/3 4/3, 15/3 8AW1 8AW1 011... 14/17 16 Siemens KT10.1 * 2004 16/9 Appendix Indexes Subject index A A&D online services Alternative voltages AS interface power supplies B Battery Battery Battery Battery Battery Battery charging module 1.2 Ah module 12 Ah module 2.5 Ah module 3.2 Ah module 7 Ah C Conditions of sale and delivery Contact persons D DC UPS module 15 A DC UPS module 40 A DC UPS module 6 A DC UPS software Dimension drawings F Fusing of the output circuit, selectivity L Line-side connection LOGO!Power M Mains specifications Mounting Mounting areas and fixing options 16 16/10 Siemens KT10.1 * 2004 16/8 10/2 11/2 14/15 9/14 9/18 9/15 9/16 9/17 16/14 16/2 9/3 9/11 9/3 9/2 section 15 14/15 14/5 13/2 14/5 14/10 14/10 O Overview of product families P Parallel connection for redundant operation and performance enhancement Planning aids Possible system disturbances and causes Power supplies, single-phase Power supplies, single- and two-phase Power supplies, three-phase 1/6 14/12 14/11 14/9 2/2, 3/2 4/2, 5/2, 6/2 7/2 S Selection guide Series connection to increase the voltage SITOP modular buffer module SITOP modular redundancy module SITOP modular signalling module SITOP select Specification sheet for customized power supplies Stabilized DC power supplies 1/9 14/14 8/2 8/2 8/2 8/4 12/3 14/2 T Totally Integrated Automation - innovations for more productivity 1/4 U Uninterruptible power supplies 9/2 Appendix Customer Support Our Services for Every Phase of Your Project Configuration and Software Engineering Support in configuring and developing with customer-oriented services from actual configuration to implementation of the automation project. 1) Service On Site .I In the face of harsh competition you need optimum conditions to keep ahead all the time: A strong starting position. A sophisticated strategy and team for the necessary support - in every phase. Service & Support from Siemens provides this support with a complete range of different services for automation and drives. With Service On Site we offer services for startup and maintenance, essential for ensuring system availability. In Germany 0180 50 50 444 1) In every phase: from planning and startup to maintenance and upgrading. Our specialists know when and where to act to keep the productivity and cost-effectiveness of your system running in top form. Online Support Repairs and Spare Parts The comprehensive information system available round the clock via Internet ranging from Product Support and Service & Support services to Support Tools in the Shop. In Germany 0180 50 50 448 1) http://www.siemens.com/ automation/service&support Technical Support Optimization and Upgrading Competent consulting in technical questions covering a wide range of customer-oriented services for all our products and systems. In the operating phase of a machine or automation system we provide a comprehensive repair and spare parts service ensuring the highest degree of operating safety and reliability. To enhance productivity and save costs in your project we offer high-quality services in optimization and upgrading. 1) Tel.: +49 (0)180 50 50 222 Fax: +49 (0)180 50 50 223 E-Mail: adsupport@siemens.com Technical Consulting Support in the planning and designing of your project from detailed actual-state analysis, target definition and consulting on product and system questions right to the creation of the automation solution. 1) 16 1) For country-specific telephone numbers go to our Internet site at: http://www.siemens.com/automation/service&support Siemens KT10.1 * 2004 16/11 Appendix Customer Support Knowledge Base on CD-ROM For locations without online connections to the Internet there are excerpts of the free part of the information sources available on CD-ROM (Service & Support Knowledge Base). This CDROM contains all the latest product information at the time of production (FAQs, Downloads, Tips and Tricks, Updates) as well as general information on Service and Technical Support. The CD-ROM also includes a full-text search and our Knowledge Manager for targeted searches for solutions. The CD-ROM will be updated every 4 months. Just the same as our online offer in the Internet, the Service & Support Knowledge Base on CD comes complete in 5 languages (German, English, French, Italian, Spanish). You can order the Service & Support Knowledge Base CD from your Siemens contact. Order no. 6ZB5310-0EP30-0BA2 Orders via the Internet (with Automation Value Card or credit card) at: http://www.siemens.com/automation/service&support in the Shop domain. Automation Value Card By entering the card number and PIN you have full access to the Service & Support services being offered. The charge for the services procured is debited from the credits on your Automation Value Card. All the services offered are marked in currency-neutral credits, so you can use the Automation Value Card worldwide. Automation Value Card order numbers Credits Small card - great support The Automation Value Card is an integral component of the comprehensive service concept with which Siemens Automation and Drives will accompany you in each phase of your automation project. Order no. 200 6ES7 997-0BA00-0XA0 500 6ES7 997-0BB00-0XA0 1000 6ES7 997-0BC00-0XA0 10000 6ES7 997-0BG00-0XA0 Detailed information on the services offered is available on our Internet site at: http://www.siemens.com/automation/service&support Service & Support a la Card: Examples It doesn't matter whether you want just specific services from our Technical Support or want to purchase high-quality Support Tools in our Online Shop, you can always pay with your Automation Value Card. No invoicing, transparent and safe. With your personal card number and associated PIN you can view the state of your account and all transactions at any time. Technical Support Services on card. This is how it's done. "System Utilities" Tools that can be used directly for configuration, analysis and testing "Applications" Complete topic solutions including ready-tested software "Functions & Samples" Adaptable blocks for accelerating your developments Card number and PIN are on the back of the Automation Value Card. When delivered, the PIN is covered by a scratch field, guaranteeing that the full credit is on the card. 16 16/12 Siemens KT10.1 * 2004 "Priority" Priority processing for urgent cases "24 h" Availability round the clock Extended" Technical consulting for complex questions Support Tools in the Support Shop Appendix Notes 16 Siemens KT10.1 * 2004 16/13 Appendix Conditions of sale and delivery Terms and Conditions of Sale and Delivery By using this catalog you can acquire hardware and software products described therein from the Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. for customers with a seat or registered office in the Federal Republic of Germany The General Terms of Payment as well as the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry shall apply. For software products, the General License Conditions for Software Products for Automation and Drives for Customers with Seat or registered Office in Germany shall apply. for customers with a seat or registered office outside of Germany The General Terms of Payment as well as the General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany shall apply. For software products, the General License Conditions for Software Products for Automation and Drives for Customers with Seat or registered Office outside of Germany shall apply. General The prices are in (Euro) ex works, exclusive packaging. The sales tax (value added tax) is not included in the prices. It shall be debited separately at the respective rate according to the applicable legal regulations. In addition to the prices of products which include silver and/or copper, surcharges may be calculated if the respective limits of the notes are exceeded. Prices are subject to change without prior notice. We will debit the prices valid at the time of delivery. The dimensions are in mm. Illustrations are not binding. Insofar as there are no remarks on the corresponding pages, - especially with regard to data, dimensions and weights given these are subject to change without prior notice. Export regulations The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL Number of the German Export List. Products marked other than "N" require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an "AL not equal to N" are subject to a European or German export authorization when being exported out of the EU. ECCN Export Control Classification Number. Products marked other than "N" are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an "ECCN not equal to N" are subject to a US re-export authorization. Even without a label or with an "AL: N" or "ECCN: N", authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice. A&D/VuL/En 14.11.03 Comprehensive Terms and Conditions of Sale and Delivery are available free of charge from your local Siemens business office under the following Order Nos.: * 6ZB5310-0KR30-0BA0 (for customers based in the Federal Republic of Germany) * 6ZB5310-0KS53-0BA0 (for customers based outside of theFederal Republic of Germany) or download them from the Internet: www.siemens.com/automation/mall (Germany: A&D Mall Online-Help System) 16 Siemens AG Automation and Drives Sales Power Supplies, System Cables Postfach 23 55 90713 FURTH FEDERAL REPUBLIC OF GERMANY 16/14 Siemens KT10.1 * 2004 Order No. E86060-K2410-A101-A5-7600 KG 1004 27.0 BD 148 En/ 522194 Printed in the Federal Republic of Germany Catalogs of the Automation and Drives Group (A&D) Further information can be obtained from our branch offices listed in the appendix of this catalog Automation and Drives Interactive catalog on CD-ROM Catalog Low-Voltage Controls and Distribution Low-Voltage Switchgear - Controlgear for Industry Catalog LV 10 * The Offline Mall of Automation and Drives CA 01 Power Distribution - Products and Systems for Low-Voltage Power Distribution LV 30 SIDAC-D reactors and SIDAC-F filters LV 63 SIVACON 8PS Busbar Trunking Systems CD, BD01, BD2 up to 1250 A LV 70 Busbar trunking systems LDA/LDC LV 71 Busbar trunking systems LXA/LXC LV 72 SENTRON WL NS WL Motion Control System SIMOTION PM 10 Automation Systems for Machine Tools SINUMERIK & SIMODRIVE NC 60 Drive Systems Variable-Speed Drives SINAMICS G130 Drive Converter Chassis Units SINAMICS G150 Drive Converter Cabinet Units D 11 SINAMICS G110 Inverter Chassis Units D 11.1 SINAMICS S120 Servo Control Drive System D 21.2 SINAMICS S150 Drive Converter Cabinet Units D 21.3 DC Motors DA 12 SIMOREG DC MASTER 6RA70 Digital Chassis Converters DA 21.1 SIMOREG K 6RA22 Analog Chassis Converters DA 21.2 PDF: Indicators for panel mounting MP 12 SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units DA 22 SIREC Recorders and Accessories MP 20 SIMOVERT PM Modular Converter Systems DA 45 SIPART, Controllers and Software MP 31 SIEMOSYN Motors DA 48 SIWAREX Weighing Systems WT 01 MICROMASTER 410/420/430/440 Inverters DA 51.2 Continuous Weighing and Process Protection WT 02 MICROMASTER 411/COMBIMASTER 411 DA 51.3 Gas Analysis Equipment for the Process Industry PA 10 SIMOVERT MV Medium-Voltage Drives DA 63 PDF: Process Analytics, Components for the System Integration PA 11 SIMOVERT MASTERDRIVES Vector Control DA 65.10 SIPAN Liquid Analysis PA 20 SIMOVERT MASTERDRIVES Motion Control DA 65.11 Synchronous and asynchronous servomotors for SIMOVERT MASTERDRIVES DA 65.3 SIMODRIVE 611 universal and POSMO DA 65.4 SIMATIC Industrial Automation Systems SIMATIC PCS Process Control System ST 45 PDF: SIMATIC S5/505 Automation Systems ST 50 Components for Totally Integrated Automation and Micro Automation ST 70 Low-Voltage Three-Phase-Motors Squirrel-Cage Motors, Totally Enclosed, Fan-Cooled M 11 Automation Systems for Machine Tools SIMODRIVE NC 60 * Main Spindle Motors * Feed Motors * Converter Systems SIMODRIVE 611/POSMO Drive and Control Components for Hoisting Equipment Process Instrumentation and Analytics Field Instruments for Process Automation Measuring Instruments for Pressure, Differential Pressure, Flow, Level and Temperature, Positioners and Liquid Meters FI 01 SIMATIC PCS 7 Process Control System ST PCS 7 PDF: Add-ons for the SIMATIC PCS 7 Process Control System ST PCS 7.A SIMATIC Control Systems ST DA SIPOS Electric Actuators Electric Rotary, Linear and Part-turn Actuators MP 35 MP 35.1/.2 HE 1 Electrical Installation Technology PDF: ALPHA Small Distribution Boards and Distribution Boards ET A1 Electric Rotary Actuators for Nuclear Plants PDF: ALPHA Side-by-Side Switchgear Cabinets ET A3 PDF: ALPHA FIX Terminal Blocks ET A5 Systems Engineering Power supplies SITOP power KT 10.1 PDF: BETA Modular Installation Devices ET B1 System cabling SIMATIC TOP connect KT 10.2 PDF: DELTA Switches and Outlets ET D1 PDF: GAMMA Building Management Systems ET G1 Factory Automation Sensors FS 10 Human Machine Interface Systems SIMATIC HMI ST 80 Industrial Communication for Automation and Drives IK PI System Solutions Applications and Products for Industry are part of the interactive catalog CA 01 TELEPERM M Process Control System AS 235, AS 235H and AS 235K automation systems PLT 111 PDF: AS 488/TM automation systems PLT 112 Operating and monitoring with WinCC/TM PLT 123 CS 275 bus system PLT 130 PDF: These catalogs are only available as pdf files. A&D/3U/En 28.09.04 Catalog KT 10.1 2004 Catalog KT 10.1 2004 SITOP Power supplies The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in terms of contract. Availability and technical specifications are subject to change without notice. sitop Siemens AG Automation and Drives Systems Engineering Sales Power Supplies, System Cables www.siemens.com Order No.: E86060-K2410-A101-A5-7600 Power supplies SITOP power LOGO!Power