Dual, Interleaved, Step-Down DC-to-DC Controller with Tracking ADP1823 FEATURES APPLICATIONS Telecommunications and networking systems Medical imaging systems Base station power Set-top boxes Printers DDR termination TYPICAL APPLICATION CIRCUIT IN = 12V 180F 180F 1F PV IN TRK1 TRK2 VREG 0.47F IRLR7807Z 1.2V, 6A EN1 EN2 BST2 BST1 0.47F DH2 DH1 IRLR7807Z ADP1823 2.2H 2.2H 2k 560F 2k SW1 SW2 CSL1 DL1 CSL2 PGND2 PGND1 FB1 2k 560F DL2 IRFR3709Z 1.8V, 8A IRFR3709Z 2k FB2 390pF 1k COMP2 390pF 2k COMP1 3900pF 4.53k FREQ 4.53k 3900pF LDOSD GND SYNC 05936-001 Fixed-frequency operation: 300 kHz, 600 kHz, or synchronized operation up to 1 MHz Supply input range: 3.7 V to 20 V Wide power stage input range: 1 V to 24 V Interleaved operation results in smaller, low cost input capacitor All-N-channel MOSFET design for low cost 0.85% accuracy at 0C to 70C Soft start, thermal overload, current-limit protection 10 A shutdown supply current Internal linear regulator Lossless RDSON current-limit sensing Reverse current protection during soft start for handling precharged outputs Independent Power OK (POK) outputs Voltage tracking for sequencing or DDR termination Available in 5 mm x 5 mm, 32-lead LFCSP Figure 1. GENERAL DESCRIPTION The ADP1823 is a versatile, dual, interleaved, synchronous, PWM buck controller that generates two independent output rails from an input of 3.7 V to 20 V, with a power input voltage that ranges from 1 V to 24 V. Each controller can be configured to provide output voltages from 0.6 V to 85% of the input voltage and is sized to handle large MOSFETs for point-of-load regulators. The two channels operate 180 out of phase, reducing stress on the input capacitor and allowing smaller, low cost components. The ADP1823 is ideal for a wide range of high power applications, such as DSP and processor core I/O power, and general-purpose power in telecommunications, medical imaging, PCs, gaming, and industrial applications. The ADP1823 operates at a pin-selectable, fixed switching frequency of either 300 kHz or 600 kHz, minimizing external component size and cost. For noise sensitive applications, it can also be synchronized to an external clock to achieve switching frequencies between 300 kHz and 1 MHz. The ADP1823 includes soft start protection to prevent inrush current from the input supply during startup, reverse current protection during soft start for precharged outputs, as well as a unique adjustable lossless current-limit scheme using external MOSFET sensing. For applications requiring power supply sequencing, the ADP1823 also provides tracking inputs that allow the output voltages to track during startup, shutdown, and faults. This feature can also be used to implement DDR memory bus termination. The ADP1823 is specified over the -40C to +125C junction temperature range and is available in a 32-lead LFCSP. Rev. D Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 (c)2006-2007 Analog Devices, Inc. All rights reserved. ADP1823 TABLE OF CONTENTS Features .............................................................................................. 1 Tracking ....................................................................................... 14 Applications....................................................................................... 1 MOSFET Drivers........................................................................ 15 Typical Application Circuit ............................................................. 1 Current Limit .............................................................................. 15 General Description ......................................................................... 1 Applications Information .............................................................. 16 Revision History ............................................................................... 2 Selecting the Input Capacitor ................................................... 16 Specifications..................................................................................... 3 Selecting the MOSFETs ............................................................. 17 Absolute Maximum Ratings............................................................ 5 Setting the Current Limit .......................................................... 18 ESD Caution.................................................................................. 5 Feedback Voltage Divider ......................................................... 18 Functional Block Diagram .............................................................. 6 Compensating the Voltage Mode Buck Regulator................. 19 Pin Configuration and Function Descriptions............................. 7 Soft Start ...................................................................................... 22 Typical Performance Characteristics ............................................. 9 Voltage Tracking......................................................................... 22 Theory of Operation ...................................................................... 13 Coincident Tracking .................................................................. 23 Input Power ................................................................................. 13 Ratiometric Tracking ................................................................. 23 Start-Up Logic............................................................................. 13 Thermal Considerations............................................................ 24 Internal Linear Regulator .......................................................... 13 PCB Layout Guidelines.................................................................. 25 Oscillator and Synchronization ................................................ 13 LFCSP Considerations............................................................... 26 Error Amplifier ........................................................................... 14 Application Circuits ....................................................................... 27 Soft Start ...................................................................................... 14 Outline Dimensions ....................................................................... 29 Power OK Indicator ................................................................... 14 Ordering Guide .......................................................................... 29 REVISION HISTORY 10/07--Rev. C to Rev D Changes to Table 1............................................................................ 3 Changes to Equation 33 and Type III Compensator Section ... 21 7/07--Rev. B to Rev C Changes to Figure 34...................................................................... 27 5/07--Rev. A to Rev. B Changes to Features Section............................................................ 1 Changes to General Description Section ...................................... 1 Changes to Power Supply and Logic Thresholds Sections.......... 3 Changes to Absolute Maximum Ratings Section......................... 5 Changes to Figure 17...................................................................... 11 Changes to Theory of Operation Section.................................... 13 Changes to Current Limit Section................................................ 15 Changes to Setting the Current Limit Section............................ 18 Changes to Compensating the Voltage Mode Buck Regulator Section............................................................................ 19 Inserted Figure 25........................................................................... 19 Deleted Table 4................................................................................ 27 Changes to Application Circuits Section..................................... 27 Changes to Figure 34...................................................................... 27 11/06--Rev. 0 to Rev. A Changes to Features and Applications Sections ............................1 Changes to Specifications Section...................................................3 Changes to Absolute Maximum Ratings Section..........................5 Replaced Theory of Operation Section ....................................... 13 Added Feedback Voltage Divider Section................................... 18 Changes to Ratiometric Tracking Section................................... 23 Replaced PCB Layout Guidelines Section................................... 25 Added Application Circuits Section ............................................ 29 Changes to Ordering Guide .......................................................... 31 4/06--Revision 0: Initial Version Rev. D | Page 2 of 32 ADP1823 SPECIFICATIONS IN = 12 V, ENx = FREQ = PV = VREG = 5 V, SYNC = GND, TJ = -40C to +125C, unless otherwise specified. All limits at temperature extremes are guaranteed via correlation using standard statistical quality control (SQC). Typical values are at TA = 25C. Table 1. Parameter POWER SUPPLY IN Input Voltage IN Quiescent Current IN Shutdown Current VREG Undervoltage Lockout Threshold VREG Undervoltage Lockout Hysteresis ERROR AMPLIFIER FB1, FB2 Regulation Voltage FB1, FB2 Input Bias Current Open-Loop Voltage Gain Gain-Bandwidth Product COMP1, COMP2 Sink Current COMP1, COMP2 Source Current COMP1, COMP2 Clamp High Voltage COMP1, COMP2 Clamp Low Voltage LINEAR REGULATOR VREG Output Voltage VREG Load Regulation VREG Line Regulation VREG Current Limit VREG Short-Circuit Current IN to VREG Dropout Voltage VREG Minimum Output Capacitance PWM CONTROLLER PWM Ramp Voltage Peak DH1, DH2 Maximum Duty Cycle DH1, DH2 Minimum Duty Cycle SOFT START SS1, SS2 Pull-Up Resistance SS1, SS2 Pull-Down Resistance SS1, SS2 to FB1, FB2 Offset Voltage SS1, SS2 Pull-Up Voltage TRACKING TRK1, TRK2 Common-Mode Input Voltage Range TRK1, TRK2 to FB1, FB2 Offset Voltage TRK1, TRK2 Input Bias Current Conditions Min PV = VREG (using internal regulator) IN = PV = VREG (not using internal regulator) Not switching, IVREG = 0 mA EN1 = EN2 = GND VREG rising 5.5 3.7 2.4 TA = 25C, TRK1, TRK2 > 700 mV TJ = 0C to 85C, TRK1, TRK2 > 700 mV TJ = -40C to +125C, TRK1, TRK2 > 700 mV TJ = 0C to 70C, TRK1, TRK2 > 700 mV 597 591 588 595 Typ 1.5 10 2.7 0.125 600 Max Unit 20 5.5 3 20 2.9 V V mA A V V 603 609 612 605 100 mV mV mV mV nA dB MHz A A V V 5.15 5.25 V V 70 20 600 120 2.4 0.75 TA = 25C, IVREG = 20 mA IN = 7 V to 20 V, IVREG = 0 mA to 100 mA, TA = -40C to +85C IVREG = 0 mA to 100 mA, IN = 12 V IN = 7 V to 20 V, IVREG = 20 mA VREG = 4 V VREG < 0.5 V IVREG = 100 mA, IN < 5 V 4.85 4.75 50 5.0 5.0 -40 1 220 140 0.7 200 1.4 1 SYNC = GND FREQ = GND (300 kHz) FREQ = GND (300 kHz) 85 SS1, SS2 = GND SS1, SS2 = 0.6 V SS1, SS2 = 0 mV to 500 mV TRK1, TRK2 = 0 mV to 500 mV Rev. D | Page 3 of 32 1.3 90 1 3 90 6 -45 0.8 0 -5 mV mV mA mA V F V % % k k mV V 600 +5 100 mV mV nA ADP1823 Parameter OSCILLATOR Oscillator Frequency SYNC Synchronization Range 1 SYNC Minimum Input Pulse Width CURRENT SENSE CSL1, CSL2 Threshold Voltage CSL1, CSL2 Output Current Current Sense Blanking Period GATE DRIVERS DH1, DH2 Rise Time DH1, DH2 Fall Time DL1, DL2 Rise Time DL1, DL2 Fall Time DH to DL, DL to DH Dead Time LOGIC THRESHOLDS SYNC, FREQ, LDOSD Input High Voltage SYNC, FREQ, LDOSD Input Low Voltage SYNC, FREQ Input Leakage Current LDOSD Pull-Down Resistance EN1, EN2 Input High Voltage EN1, EN2 Input Low Voltage EN1, EN2 Current Source EN1, EN2 Input Impedance to 5 V Zener THERMAL SHUTDOWN Thermal Shutdown Threshold 2 Thermal Shutdown Hysteresis2 POWER GOOD FB1, UV2 Overvoltage Threshold FB1, UV2 Overvoltage Hysteresis FB1, UV2 Undervoltage Threshold FB1, UV2 Undervoltage Hysteresis POK1, POK2 Propagation Delay POK1, POK2 Off Leakage Current POK1, POK2 Output Low Voltage UV2 Input Bias Current 1 2 Conditions Min Typ Max Unit SYNC = FREQ = GND (fSW = fOSC) SYNC = GND, FREQ = VREG (fSW = fOSC) FREQ = GND, SYNC = 600 kHz to 1.2 MHz (fSW = fSYNC/2) FREQ = VREG, SYNC = 1.2 MHz to 2 MHz (fSW = fSYNC/2) 240 480 300 600 300 600 370 720 600 1000 200 kHz kHz kHz kHz ns Relative to PGND CSL1, CSL2 = PGND -30 44 0 50 100 +30 56 mV A ns CDH = 3 nF, VBST - VSW = 5 V CDH = 3 nF, VBST - VSW = 5 V CDL = 3 nF CDL = 3 nF 15 10 15 10 40 ns ns ns ns ns 2.2 0.4 1 SYNC, FREQ = 0 V to 5.5 V 100 IN = 3.7 V to 20 V IN = 3.7 V to 20 V EN1, EN2 = 0 V to 3.0 V EN1, EN2 = 5.5 V to 20 V VFB1, VUV2 rising VFB1, VUV2 rising VPOK1, VPOK2 = 5.5 V IPOK1, IPOK2 = 10 mA 2.0 -0.05 -0.6 100 0.8 -1.5 V V A k V V A k 145 15 C C 750 50 550 50 8 mV mV mV mV s A mV nA 150 10 1 500 100 SYNC input frequency is 2x the single-channel switching frequency. The SYNC frequency is divided by 2, and the separate phases were used to clock the controllers. Guaranteed by design and not subject to production test. Rev. D | Page 4 of 32 ADP1823 ABSOLUTE MAXIMUM RATINGS Table 2. Parameter IN, EN1, EN2 BST1, BST2 BST1, BST2 to SW1, SW2 CSL1, CSL2 SW1, SW2 DH1 DH2 DL1, DL2 to PGND PGND to GND LDOSD, SYNC, FREQ, COMP1, COMP2, SS1, SS2, FB1, FB2, VREG, PV, POK1, POK2, TRK1, TRK2 JA 4-Layer (JEDEC Standard Board) 1, 2 Operating Ambient Temperature Operating Junction Temperature 3 Storage Temperature Range Rating -0.3 V to +20 V -0.3 V to +30 V -0.3 V to +6 V -1 V to +30 V -2 V to +30 V SW1 - 0.3 V to BST1 + 0.3 V SW2 - 0.3 V to BST2 + 0.3 V -0.3 V to PV + 0.3 V 2 V -0.3 V to +6 V Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ESD CAUTION 45C/W -40C < TA < +85C -55C < TJ < +125C -65C to +150C 1 Measured with exposed pad attached to PCB. Junction-to-ambient thermal resistance (JA) of the package is based on modeling and calculation using a 4-layer board. The junction-to-ambient thermal resistance is application and board-layout dependent. In applications where high maximum power dissipation exists, attention to thermal dissipation issues in board design is required. For more information, refer to Application Note AN-772, A Design and Manufacturing Guide for the Lead Frame Chip Scale Package (LFCSP). 3 In applications where high power dissipation and poor package thermal resistance are present, the maximum ambient temperature may have to be derated. Maximum ambient temperature (TA_MAX) is dependent on the maximum operating junction temperature (TJ_MAX_OP = 125oC), the maximum power dissipation of the device in the application (PD_MAX), and the junctionto-ambient thermal resistance of the part/package in the application (JA), and is given by: TA_MAX = TJ_MAX_OP - (JA x PD_MAX). 2 Rev. D | Page 5 of 32 ADP1823 FUNCTIONAL BLOCK DIAGRAM IN ADP1823 VREG LINEAR REG 0.6V 0.8V 0.75V REF 0.55V THERMAL SHUTDOWN UVLO VREG VREG BST1 LDOSD ILIM2 EN1 DH1 CK1 LOGIC S Q SW1 PWM EN2 FAULT1 R FAULT2 PV Q CK1 FREQ SYNC DL1 RAMP1 OSCILLATOR PHASE 1 = 0 PHASE 2 = 180 VREG + ILIM1 CK2 50A PGND1 - CSL1 RAMP2 RAMP1 + POK1 - COMP1 FB1 TRK1 0.6V - + + + 0.75V + - BST2 + SS1 0.8V 0.55V DH2 - S CK2 FAULT1 Q PWM RAMP2 + R FB2 TRK2 0.6V - + + + 0.75V + - UV2 SS2 Q - COMP2 + 0.8V 0.55V - SW2 PV DL2 VREG 50A ILIM2 + PGND2 - CSL2 POK2 FAULT2 GND 05936-002 BOTTOM PADDLE OF LFCSP Figure 2. Rev. D | Page 6 of 32 ADP1823 32 31 30 29 28 27 26 25 COMP1 TRK1 SS1 VREG IN LDOSD EN2 EN1 PIN CONFIGURATION AND FUNCTION DESCRIPTIONS 1 2 3 4 5 6 7 8 PIN 1 INDICATOR ADP1823 TOP VIEW (Not to Scale) 24 23 22 21 20 19 18 17 POK1 BST1 DH1 SW1 CSL1 PGND1 DL1 PV 05936-003 SS2 POK2 BST2 DH2 SW2 CSL2 PGND2 DL2 9 10 11 12 13 14 15 16 FB1 SYNC FREQ GND UV2 FB2 COMP2 TRK2 Figure 3. Pin Configuration Table 3. Pin Function Descriptions Pin No. 1 Mnemonic FB1 2 SYNC 3 4 FREQ GND 5 UV2 6 FB2 7 8 COMP2 TRK2 9 10 SS2 POK2 11 BST2 12 13 14 DH2 SW2 CSL2 15 16 17 PGND2 DL2 PV 18 19 20 DL1 PGND1 CSL1 21 22 23 SW1 DH1 BST1 Description Feedback Voltage Input for Channel 1. Connect a resistor divider from the buck regulator output to GND and tie the tap to FB1 to set the output voltage. Frequency Synchronization Input. Accepts external signal between 600 kHz and 1.2 MHz or between 1.2 MHz and 2 MHz depending on whether FREQ is low or high, respectively. Connect SYNC to ground if not used. Frequency Select Input. Low for 300 kHz or high for 600 kHz. Ground. Connect to a ground plane directly beneath the ADP1823. Tie the bottom of the feedback dividers to this GND. Input to the POK2 Undervoltage and Overvoltage Comparators. For the default thresholds, connect UV2 directly to FB2. For some tracking applications, connect UV2 to an extra tap on the FB2 voltage divider string. Feedback Voltage Input for Channel 2. Connect a resistor divider from the buck regulator output to GND and tie the tap to FB2 to set the output voltage. Error Amplifier Output for Channel 2. Connect an RC network from COMP2 to FB2 to compensate Channel 2. Tracking Input for Channel 2. To track a master voltage, drive TRK2 from a voltage divider to the master voltage. If the tracking function is not used, connect TRK2 to VREG. Soft Start Control Input. Connect a capacitor from SS2 to GND to set the soft start period. Open-Drain Power OK Output for Channel 2. Sinks current when UV2 is out of regulation. Connect a pull-up resistor from POK2 to VREG. Boost Capacitor Input for Channel 2. Powers the high-side gate driver, DH2. Connect a 0.22 F to 0.47 F ceramic capacitor from BST2 to SW2 and a Schottky diode from PV to BST2. High-Side (Switch) Gate Driver Output for Channel 2. Switch Node Connection for Channel 2. Current Sense Comparator Inverting Input for Channel 2. Connect a resistor between CSL2 and SW2 to set the current-limit offset. Ground for Channel 2 Gate Driver. Connect to a ground plane directly beneath the ADP1823. Low-Side (Synchronous Rectifier) Gate Driver Output for Channel 2. Positive Input Voltage for Gate Driver DL1 and Gate Driver DL2. Connect PV to VREG and bypass to ground with a 1 F capacitor. Low-Side (Synchronous Rectifier) Gate Driver Output for Channel 1. Ground for Channel 1 Gate Driver. Connect to a ground plane directly beneath the ADP1823. Current Sense Comparator Inverting Input for Channel 1. Connect a resistor between CSL1 and SW1 to set the current-limit offset. Switch Node Connection for Channel 1. High-Side (Switch) Gate Driver Output for Channel 1. Boost Capacitor Input for Channel 1. Powers the high-side gate driver, DH1. Connect a 0.22 F to 0.47 F ceramic capacitor from BST1 to SW1 and a Schottky diode from PV to BST1. Rev. D | Page 7 of 32 ADP1823 Pin No. 24 Mnemonic POK1 25 EN1 26 EN2 27 LDOSD 28 IN 29 VREG 30 31 SS1 TRK1 32 COMP1 Description Open-Drain Power OK Output for Channel 1. Sinks current when FB1 is out of regulation. Connect a pull-up resistor from POK1 to VREG. Enable Input for Channel 1. Drive EN1 high to turn on the Channel 1 controller, and drive it low to turn off the Channel 1 controller. Enabling starts the internal LDO. Tie to IN for automatic startup. Enable Input for Channel 2. Drive EN2 high to turn on the Channel 2 controller, and drive it low to turn off the Channel 2 controller. Enabling starts the internal LDO. Tie to IN for automatic startup. LDO Shut-Down Input. Only used to shut down the LDO in those applications where IN is tied directly to VREG. Otherwise, connect LDOSD to GND or leave it open because it has an internal 100 k pull-down resistor. Input Supply to the Internal Linear Regulator. Drive IN with 5.5 V to 20 V to power the ADP1823 from the LDO. For input voltages between 3.7 V and 5.5 V, tie IN to VREG and PV. Output of the Internal Linear Regulator (LDO). The internal circuitry and gate drivers are powered from VREG. Bypass VREG to the ground plane with a 1 F ceramic capacitor. Soft Start Control Input. Connect a capacitor from SS1 to GND to set the soft start period. Tracking Input for Channel 1. To track a master voltage, drive TRK1 from a voltage divider to the master voltage. If the tracking function is not used, connect TRK1 to VREG. Error Amplifier Output for Channel 1. Connect an RC network from COMP1 to FB1 to compensate Channel 1. Rev. D | Page 8 of 32 ADP1823 TYPICAL PERFORMANCE CHARACTERISTICS 95 92 VIN = 5V SWITCHING FREQUENCY = 300kHz VIN = 12V 90 90 85 EFFICIENCY (%) EFFICIENCY (%) 88 VIN = 20V VIN = 15V 80 86 84 SWITCHING FREQUENCY = 600kHz 82 75 0 5 10 15 20 LOAD CURRENT (A) 78 05936-004 70 0 5 10 20 15 LOAD CURRENT (A) Figure 4. Efficiency vs. Load Current, VOUT = 1.8 V, 300 kHz Switching 05936-007 80 Figure 7. Efficiency vs. Load Current, VIN = 12 V, VOUT = 1.8 V 95 4.980 VOUT = 3.3V 90 4.975 VREG VOLTAGE (V) EFFICIENCY (%) VOUT = 1.8V 85 VOUT = 1.2V 80 4.970 4.965 5 10 15 20 LOAD CURRENT (A) 4.960 -40 -15 10 35 60 85 05936-008 0 05936-005 70 20 05936-009 75 TEMPERATURE (C) Figure 5. Efficiency vs. Load Current, VIN = 12 V, 300 kHz Switching Figure 8. VREG Voltage vs. Temperature 94 4.970 SWITCHING FREQUENCY = 300kHz 92 4.968 4.966 90 VREG (V) 86 SWITCHING FREQUENCY = 600kHz 84 4.962 4.960 4.958 4.956 82 4.954 80 78 4.952 0 5 10 15 LOAD CURRENT (A) 20 05936-006 EFFICIENCY (%) 4.964 88 Figure 6. Efficiency vs. Load Current, VIN = 5 V, VOUT = 1.8 V 4.950 5 8 11 14 17 INPUT VOLTAGE (V) Figure 9. VREG vs. Input Voltage, 10 mA Load Rev. D | Page 9 of 32 ADP1823 4.960 0.6010 0.6005 FEEDBACK VOLTAGE (V) 4.952 4.948 4.944 0.5995 0.5990 0.5985 0 20 40 60 80 100 LOAD CURRENT (mA) 0.5980 -40 05936-010 4.940 0.6000 -15 10 35 60 85 TEMPERATURE (C) Figure 10. VREG vs. Load Current, VIN = 12 V 05936-013 VREG (V) 4.956 Figure 13. Feedback Voltage vs. Temperature, VIN = 12 V 330 5 320 FREQUENCY (Hz) 310 3 2 300 290 280 1 50 100 150 200 250 LOAD CURRENT (mA) 260 -40 -15 10 35 60 85 05936-014 0 05936-011 0 20 05936-015 270 TEMPERATURE (C) Figure 11. VREG Current-Limit Foldback Figure 14. Switching Frequency vs. Temperature, VIN = 12 V 5 T 4 SUPPLY CURRENT (mA) VREG, AC-COUPLED, 1V/DIV SW1 PIN, VOUT = 1.8V, 10V/DIV SW2 PIN, VOUT = 1.2V, 10V/DIV 200ns/DIV 3 2 1 05936-012 VREG OUTPUT (V) 4 0 2 5 8 11 14 17 SUPPLY VOLTAGE (V) Figure 15. Supply Current vs. Supply Voltage Figure 12. VREG Output During Normal Operation Rev. D | Page 10 of 32 ADP1823 T EXTERNAL CLOCK, FREQUENCY = 1MHz T VOUT1, AC-COUPLED, 100mV/DIV SW PIN, CHANNEL 1 LOAD ON 100s/DIV 400ns/DIV Figure 16. 1.5 A to 15 A Load Transient Response, VIN = 12 V T 05936-019 SW PIN, CHANNEL 2 LOAD OFF 05936-016 LOAD OFF Figure 19. Out-of-Phase Switching, External 1 MHz Clock T SS1, 0.5V/DIV VOUT1, 0.5V/DIV EXTERNAL CLOCK, FREQUENCY = 2MHz SW PIN, CHANNEL 1 INPUT CURRENT, 0.2A/DIV SHORT CIRCUIT REMOVED 05936-020 SW PIN, CHANNEL 2 4ms/DIV 05936-017 SHORT CIRCUIT APPLIED 200ns/DIV Figure 17. Output Short-Circuit Response Figure 20. Out-of-Phase Switching, External 2 MHz Clock T VIN = 12V T VOUT1, 2V/DIV SWITCH NODE CHANNEL 1 EN1, 5V/DIV 10ms/DIV Figure 18. Out-of-Phase Switching, Internal Oscillator Figure 21. Enable Pin Response, VIN = 12 V Rev. D | Page 11 of 32 05936-021 400ns/DIV 05936-018 SWITCH NODE CHANNEL 2 ADP1823 T VIN, 5V/DIV EN2 PIN, 5V/DIV VOUT2, 2V/DIV VOUT, 2V/DIV EN1 = 5V Figure 24. Coincident Voltage Tracking Response Figure 22. Power-On Response, EN Tied to VIN TRACK PIN VOLTAGE, 200mV/DIV T 05936-023 FEEDBACK PIN VOLTAGE, 200mV/DIV 20ms/DIV 40ms/DIV Figure 23. Output Voltage Tracking Response Rev. D | Page 12 of 32 05936-024 05936-022 SOFT START, 1V/DIV 4ms/DIV VOUT1, 2V/DIV ADP1823 THEORY OF OPERATION The ADP1823 is a dual, synchronous, PWM buck controller capable of generating output voltages down to 0.6 V and output currents in the tens of amps. The switching of the regulators is interleaved for reduced current ripple. It is ideal for a wide range of applications, such as DSP and processor core I/O supplies, general-purpose power in telecommunications, medical imaging, gaming, PCs, set-top boxes, and industrial controls. The ADP1823 controller operates directly from 3.7 V to 20 V, and the power stage input voltage range is 1 V to 24 V, which applies directly to the drain of the high-side external power MOSFET. It includes fully integrated MOSFET gate drivers and a linear regulator for internal and gate drive bias. The ADP1823 operates at a fixed 300 kHz or 600 kHz switching frequency. The ADP1823 can also be synchronized to an external clock to switch at up to 1 MHz per channel. The ADP1823 includes soft start to prevent inrush current during startup, as well as a unique adjustable lossless current limit. The ADP1823 offers flexible tracking for startup and shutdown sequencing. It is specified over the -40C to +125C temperature range and is available in a space-saving, 5 mm x 5 mm, 32-lead LFCSP. INPUT POWER The ADP1823 is powered from the IN pin up to 20 V. The internal low dropout linear regulator, VREG, regulates the IN voltage down to 5 V. The control circuits, gate drivers, and external boost capacitors operate from the LDO output. Tie the PV pin to VREG and bypass VREG with a 1 F or greater capacitor. The ADP1823 phase shifts the switching of the two step-down converters by 180, thereby reducing the input ripple current. The phase shift reduces the size and cost of the input capacitors. The input voltage should be bypassed with a capacitor close to the high-side switch MOSFETs (see the Selecting the Input Capacitor section). In addition, a minimum 0.1 F ceramic capacitor should be placed as close as possible to the IN pin. The VREG output is sensed by the undervoltage lockout (UVLO) circuit to be certain that enough voltage headroom is available to run the controllers and gate drivers. As VREG rises above about 2.7 V, the controllers are enabled. The IN voltage is not directly monitored by UVLO. If the IN voltage is insufficient to allow VREG to be above the UVLO threshold, the controllers are disabled but the LDO continues to operate. The LDO is enabled whenever either EN1 or EN2 is high, even if VREG is below the UVLO threshold. If the desired input voltage is between 3.7 V and 5.5 V, connect IN directly to the VREG pin and the PV pin, and drive LDOSD high to disable the internal regulator. The ADP1823 requires that the voltage at VREG and PV be limited to no more than 5.5 V, which is the only application where the LDOSD pin is used. Otherwise, it should be grounded or left open. LDOSD has an internal 100 k pull-down resistor. Although IN is limited to 20 V, the switching stage can run from up to 24 V, and the BST pins can go to 30 V to support the gate drive. Dissipation on the ADP1823 can be limited by running IN from a low voltage rail while operating the switches from the high voltage rail. START-UP LOGIC The ADP1823 features independent enable inputs for each channel. Drive EN1 or EN2 high to enable their respective controllers. The LDO starts when either channel is enabled. When both controllers are disabled, the LDO is disabled and the IN quiescent current drops to about 10 A. For automatic startup, connect EN1 and/or EN2 to IN. The enable pins are 20 V compliant, but they sink current through an internal 100 k resistor when the EN pin voltage exceeds about 5 V. INTERNAL LINEAR REGULATOR The internal linear regulator, VREG, is low dropout, which means it can regulate its output voltage close to the input voltage. VREG powers up the internal control and provides bias for the gate drivers. It is guaranteed to have more than 100 mA of output current capability, which is sufficient to handle the gate drive requirements of typical logic threshold MOSFETs driven at up to 1 MHz. VREG should always be bypassed with a 1 F or greater capacitor. Because the LDO supplies the gate drive current, the output of VREG is subject to sharp transient currents as the drivers switch and the boost capacitors recharge during each switching cycle. The LDO has been optimized to handle these transients without overload faults. Due to the gate drive loading, using the VREG output for other auxiliary system loads is not recommended. The LDO includes a current limit well above the expected maximum gate drive load. This current limit also includes a short-circuit foldback to further limit the VREG current in the event of a fault. OSCILLATOR AND SYNCHRONIZATION The ADP1823 internal oscillator can be set to either 300 kHz or 600 kHz. Drive the FREQ pin low for 300 kHz; drive it high for 600 kHz. The oscillator generates a start clock for each switching phase and generates the internal ramp voltages for the PWM modulation. The SYNC input is used to synchronize the converter switching frequency to an external signal. The SYNC input should be driven with twice the desired switching frequency, as the SYNC input is divided by 2, and the resulting phases are used to clock the two channels alternately. Rev. D | Page 13 of 32 ADP1823 If FREQ is driven low, the recommended SYNC input frequency is between 600 kHz and 1.2 MHz. If FREQ is driven high, the recommended SYNC frequency is between 1.2 MHz and 2 MHz. The FREQ setting should be carefully observed for these SYNC frequency ranges, because the PWM voltage ramp scales down from about 1.3 V based on the percentage of frequency overdrive. Driving SYNC faster than recommended for the FREQ setting results in a small ramp signal, which could affect the signal-to-noise ratio and the modulator gain and stability. When an external clock is detected at the first SYNC edge, the internal oscillator is reset and clock control shifts to SYNC. The SYNC edges then trigger subsequent clocking of the PWM outputs. The DH rising edges appear about 400 ns after the corresponding SYNC edge, and the frequency is locked to the external signal. Depending on the start-up conditions of Channel 1 and Channel 2, either Channel 1 or Channel 2 can be the first channel synchronized to the rising edge of the SYNC clock. If the external SYNC signal disappears during operation, the ADP1823 reverts to its internal oscillator and experiences a delay of no more than a single cycle of the internal oscillator. ERROR AMPLIFIER The ADP1823 error amplifiers are operational amplifiers. The ADP1823 senses the output voltages through external resistor dividers at the FB1 and FB2 pins. The FB pins are the inverting inputs to the error amplifiers. The error amplifiers compare these feedback voltages to the internal 0.6 V reference, and the outputs of the error amplifiers appear at the COMP1 and COMP2 pins. The COMP pin voltages then directly control the duty cycle of each respective switching converter. A series/parallel RC network is tied between the FB pins and their respective COMP pins to provide the compensation for the buck converter control loops. A detailed design procedure for compensating the system is provided in the Compensating the Voltage Mode Buck Regulator section. The error amplifier outputs are clamped between a lower limit of about 0.7 V and a higher limit of about 2.4 V. When the COMP pins are low, the switching duty cycle goes to 0%, and when the COMP pins are high, the switching duty cycle goes to the maximum. The SS and TRK pins are auxiliary positive inputs to the error amplifiers. Whichever has the lowest voltage, SS, TRK, or the internal 0.6 V reference controls the FB pin voltage and thus the output. Therefore, if two or more of these inputs are close to each other, a small offset is imposed on the error amplifier. For example, if TRK approaches the 0.6 V reference, the FB sees about 18 mV of negative offset at room temperature. For this reason, the soft start pins have a built-in negative offset and they charge to 0.8 V. If the TRK pins are not used, they should be tied high to VREG. SOFT START The ADP1823 employs a programmable soft start that reduces input current transients and prevents output overshoot. The SS1 and SS2 pins drive auxiliary positive inputs to their respective error amplifiers, thus the voltage at these pins regulates the voltage at their respective feedback control pins. Program soft start by connecting capacitors from SS1 and SS2 to GND. When starting up, the capacitor charges from an internal 90 k resistor to 0.8 V. The regulator output voltage rises with the voltage at its respective soft start pin, allowing the output voltage to rise slowly, reducing inrush current. See the Soft Start section in the Applications Information section for more information. When a controller is disabled or experiences a current fault, the soft start capacitor discharges through an internal 6 k resistor, so that at restart or recovery from fault, the output voltage soft starts again. POWER OK INDICATOR The ADP1823 features open-drain, power OK outputs, POK1 and POK2, which sink current when their respective output voltages drop, typically 8% below the nominal regulation voltage. The POK pins also go low for overvoltage of typically 25%. Use this output as a logical power-good signal by connecting pull-up resistors from POK1 and POK2 to VREG. The POK1 comparator directly monitors FB1, and the threshold is fixed at 550 mV for undervoltage and 750 mV for overvoltage. However, the POK2 undervoltage and overvoltage comparator input is connected to UV2 rather than FB2. For the default thresholds at FB2, connect UV2 directly to FB2. In a ratiometric tracking configuration, however, Channel 2 can be configured to be a fraction of a master voltage, and thus FB2 is regulated to a voltage lower than the 0.6 V internal reference. In this configuration, UV2 can be tied to a different tap on the feedback divider, allowing a POK2 indication at an appropriate output voltage threshold. See the Setting the Channel 2 Undervoltage Threshold for Ratiometric Tracking section. TRACKING The ADP1823 features tracking inputs, TRK1 and TRK2, which make the output voltages track another master voltage. Voltage tracking is especially useful in core and I/O voltage sequencing applications where one output of the ADP1823 can be set to track and not exceed the other, or in other multiple output systems where specific sequencing is required. The internal error amplifiers include three positive inputs, the internal 0.6 V reference voltage and their respective SS and TRK pins. The error amplifiers regulate the FB pins to the lowest of the three inputs. To track a supply voltage, tie the TRK pin to a resistor divider from the voltage to be tracked. See the Voltage Tracking section. Rev. D | Page 14 of 32 ADP1823 MOSFET DRIVERS CURRENT LIMIT The DH1 and DH2 pins drive the high-side switch MOSFETs. These boosted 5 V gate drivers are powered by bootstrap capacitor circuits. This configuration allows the high-side, N-channel MOSFET gate to be driven above the input voltage, allowing full enhancement and a low voltage drop across the MOSFET. The bootstrap capacitors are connected from the SW pins to their respective BST pins. The bootstrap Schottky diodes from the PV pin to the BST pins recharge the bootstrap capacitors every time the SW nodes go low. Use a bootstrap capacitor value greater than 100x the high-side MOSFET input capacitance. The ADP1823 employs a unique, programmable, cycle-by-cycle lossless current-limit circuit that uses a small, ordinary, inexpensive resistor to set the threshold. Every switching cycle, the synchronous rectifier turns on for a minimum time and the voltage drop across the MOSFET RDSON is measured during the off cycle to determine whether the current is too high. In practice, the switch node can run up to 24 V of input voltage, and the boost nodes can operate more than 5 V above this to allow full gate drive. The IN pin can be run from 3.7 V to 20 V, which can provide an advantage, for example, in the case of high frequency operation from very high input voltage. Dissipation on the ADP1823 can be limited by running IN from a lower voltage rail while operating the switches from the high voltage rail. The switching cycle is initiated by the internal clock signal. The high-side MOSFET is turned on by the DH driver, and the SW node goes high, pulling up on the inductor. When the internally generated ramp signal crosses the COMP pin voltage, the switch MOSFET is turned off and the low-side synchronous rectifier MOSFET is turned on by the DL driver. Active break-beforemake circuitry, as well as a supplemental fixed dead time, are used to prevent cross-conduction in the switches. The DL1 and DL2 pins provide gate drive for the low-side MOSFET synchronous rectifiers. Internal circuitry monitors the external MOSFETs to ensure break-before-make switching to prevent cross-conduction. An active dead time reduction circuit reduces the break-before-make time of the switching to limit the losses due to current flowing through the synchronous rectifier body diode. The PV pin provides power to the low-side drivers. It is limited to 5.5 V maximum input and should have a local decoupling capacitor. The synchronous rectifiers are turned on for a minimum time of about 200 ns on every switching cycle to sense the current. This minimum on time and the nonoverlap dead times put a limit on the maximum high-side switch duty cycle based on the selected switching frequency. Typically, this is about 90% at 300 kHz switching, and at 1 MHz switching, it reduces to about 70% maximum duty cycle. Because the two channels are 180 out of phase, if one is operating around 50% duty cycle, it is common for it to jitter when the other channel starts switching. The magnitude of the jitter depends somewhat on layout, but it is difficult to avoid in practice. When the ADP1823 is disabled, the drivers shut off the external MOSFETs, so that the SW node becomes three-stated or changes to high impedance. This measurement is done by an internal current-limit comparator and an external current-limit set resistor. The resistor is connected between the switch node (that is, the drain of the rectifier MOSFET) and the CSL pin. The CSL pin, which is the inverting input of the comparator, forces 50 A through the resistor to create an offset voltage drop across it. When the inductor current is flowing in the MOSFET rectifier, its drain is forced below PGND by the voltage drop across its RDSON. If the RDSON voltage drop exceeds the preset drop on the external resistor, the inverting comparator input is similarly forced below PGND and an overcurrent fault is flagged. The normal transient ringing on the switch node is ignored for 100 ns after the synchronous rectifier turns on; therefore, the overcurrent condition must also persist for 100 ns in order for a fault to be flagged. When an overcurrent event occurs, the overcurrent comparator prevents switching cycles until the rectifier current has decayed below the threshold. The overcurrent comparator is blanked for the first 100 ns of the synchronous rectifier cycle to prevent switch node ringing from falsely tripping the current limit. The ADP1823 senses the current limit during the off cycle. When the current-limit condition occurs, the ADP1823 resets the internal clock until the overcurrent condition disappears. The ADP1823 suppresses the start clock cycles until the overload condition is removed. At the same time, the SS capacitor is discharged through a 6 k resistor. The SS input is an auxiliary positive input of the error amplifier, so it behaves like another voltage reference. The lowest reference voltage wins. Discharging the SS voltage causes the converter to use a lower voltage reference when switching is allowed again. Therefore, as switching cycles continue around the current limit, the output looks roughly like a constant current source due to the rectifier limit, and the output voltage droops as the load resistance decreases. In the event of a short circuit, the short-circuit output current is the current limit set by the RCL resistor and is monitored cycle by cycle. When the overcurrent condition is removed, operation resumes in soft start mode. In the event of a short circuit, the ADP1823 also offers a technique for implementing a current-limit foldback with the use of an additional resistor. See the Setting the Current Limit section for more information. Rev. D | Page 15 of 32 ADP1823 APPLICATIONS INFORMATION Choose the inductor value by SELECTING THE INPUT CAPACITOR The input current to a buck converter is a pulse waveform. It is zero when the high-side switch is off and approximately equal to the load current when it is on. The input capacitor carries the input ripple current, allowing the input power source to supply only the dc current. The input capacitor needs sufficient ripple current rating to handle the input ripple and ESR that is low enough to mitigate input voltage ripple. For the usual current ranges for these converters, good practice is to use two parallel capacitors placed close to the drains of the high-side switch MOSFETs, one bulk capacitor of sufficiently high current rating as calculated in Equation 1, along with a 10 F ceramic capacitor. Select an input bulk capacitor based on its ripple current rating. If both Channel 1 and Channel 2 maximum output load currents are about the same, the input ripple current is less than half of the higher of the output load currents. In this case, use an input capacitor with a ripple current rating greater than half of the highest load current. I RIPPLE > IL 2 VOUT VIN (2) In this case, the input capacitor ripple current is approximately I RIPPLE I L D(1 - D) (3) where: IL is the maximum inductor or load current for the channel. D is the duty cycle. Use this method to determine the input capacitor ripple current rating for duty cycles between 20% and 80%. For duty cycles less than 20% or greater than 80%, use an input capacitor with a ripple current rating of IRIPPLE > 0.4 IL. Selecting the Output LC Filter The output LC filter attenuates the switching voltage, making the output an almost dc voltage. The output LC filter characteristics determine the residual output ripple voltage. VIN - VOUT VOUT I L f SW VIN (4) where: L is the inductor value. fSW is the switching frequency. VOUT is the output voltage. VIN is the input voltage. IL is the inductor ripple current, typically 1/3 of the maximum dc load current. Choose the output bulk capacitor to set the desired output voltage ripple. The impedance of the output capacitor at the switching frequency multiplied by the ripple current gives the output voltage ripple. The impedance is made up of the capacitive impedance plus the nonideal parasitic characteristics, the equivalent series resistance (ESR), and the equivalent series inductance (ESL). The output voltage ripple can be approximated with (1) If the Output 1 and Output 2 load currents are significantly different (if the smaller is less than 50% of the larger), the procedure in Equation 1 yields a larger input capacitor than required. In this case, the input capacitor can be chosen as in the case of a single phase converter with only the higher load current; therefore, first determine the duty cycle of the output with the larger load current. D= L= 1 VOUT = I L ESR + + 4 f SW ESL 8 f SW C OUT (5) where: VOUT is the output ripple voltage. IL is the inductor ripple current. ESR is the equivalent series resistance of the output capacitor (or the parallel combination of ESR of all output capacitors). ESL is the equivalent series inductance of the output capacitor (or the parallel combination of ESL of all capacitors). Note that the factors of 8 and 4 in Equation 5 would normally be 2 for sinusoidal waveforms, but the ripple current waveform in this application is triangular. Parallel combinations of different types of capacitors, for example, a large aluminum electrolytic in parallel with MLCCs, may give different results. Usually, the impedance is dominated by ESR at the switching frequency, as stated in the maximum ESR rating on the capacitor data sheet, so this equation reduces to VOUT I L ESR (6) Electrolytic capacitors have significant ESL also, on the order of 5 nH to 20 nH, depending on type, size, and geometry, and PCB traces contribute some ESR and ESL as well. However, using the maximum ESR rating from the capacitor data sheet usually provides some margin such that measuring the ESL is not usually required. Choose an inductor value such that the inductor ripple current is approximately 1/3 of the maximum dc output load current. Using a larger value inductor results in a physical size larger than is required, and using a smaller value results in increased losses in the inductor and MOSFETs. Rev. D | Page 16 of 32 ADP1823 In the case of output capacitors where the impedance of the ESR and ESL are small at the switching frequency, for instance, where the output capacitor is a bank of parallel MLCC capacitors, the capacitive impedance dominates and the ripple equation reduces to VOUT I L 8 COUT f SW (7) Make sure that the ripple current rating of the output capacitors is greater than the maximum inductor ripple current. During a load step transient on the output, the output capacitor supplies the load until the control loop has a chance to ramp the inductor current. This initial output voltage deviation due to a change in load is dependent on the output capacitor characteristics. Again, usually the capacitor ESR dominates this response, and the VOUT in Equation 6 can be used with the load step current value for IL. SELECTING THE MOSFETs The choice of MOSFET directly affects the dc-to-dc converter performance. The MOSFET must have low on resistance (RDSON) to reduce I2R losses and low gate charge to reduce switching losses. In addition, the MOSFET must have low thermal resistance to ensure that the power dissipated in the MOSFET does not result in overheating. The power switch, or high-side MOSFET, carries the load current during the PWM on time, carries the transition loss of the switching behavior, and requires gate charge drive to switch. Typically, the smaller the MOSFET RDSON, the higher the gate charge and vice versa. Therefore, it is important to choose a high-side MOSFET that balances those two losses. The conduction loss of the high-side MOSFET is determined by PC I L 2 RDSON VOUT VIN (8) where: PC is the conduction power loss. RDSON is the MOSFET on resistance. The gate charge losses are dissipated by the ADP1823 regulator and gate drivers and affect the efficiency of the system. The gate charge loss is approximated by PG V IN Q G f SW where: PG is the gate charge power. QG is the MOSFET total gate charge. fSW is the converter switching frequency. Making the conduction losses balance the gate charge losses usually yields the most efficient choice. (9) Furthermore, the high-side MOSFET transition loss is approximated by PT VIN I L (t R + t F ) f SW (10) 2 where tR and tF are the rise and fall times of the selected MOSFET as stated in the MOSFET data sheet. The total power dissipation of the high-side MOSFET is the sum of the previous losses. PD = PC + PG + PT (11) where PD is the total high-side MOSFET power loss. This dissipation heats the high-side MOSFET. The conduction losses may need an adjustment to account for the MOSFET RDSON variation with temperature. Note that MOSFET RDSON increases with increasing temperature. The MOSFET data sheet should list the thermal resistance of the package, JA, along with a normalized curve of the temperature coefficient of RDSON. For the power dissipation estimated, calculate the MOSFET junction temperature rise over the ambient temperature of interest. TJ = TA + JA PD (12) Next, calculate the new RDSON from the temperature coefficient curve and the RDSON specification at 25C. A typical value of the temperature coefficient (TC) of RDSON is 0.004/C; therefore, an alternate method to calculate the MOSFET RDSON at a second temperature, TJ, is RDSON @ TJ = RDSON @ 25C[1 + TC(TJ - 25C)] (13) Then the conduction losses can be recalculated and the procedure iterated once or twice until the junction temperature calculations are relatively consistent. The synchronous rectifier, or low-side MOSFET, carries the inductor current when the high-side MOSFET is off. For high input voltage and low output voltage, the low-side MOSFET carries the current most of the time, and therefore, to achieve high efficiency it is critical to optimize the low-side MOSFET for small on resistance. In cases where the power loss exceeds the MOSFET rating, or lower resistance is required than is available in a single MOSFET, connect multiple low-side MOSFETs in parallel. The equation for low-side MOSFET power loss is V PLS I L 2 RDSON 1 - OUT VIN (14) where: PLS is the low-side MOSFET on resistance. RDSON is the parallel combination of the resistances of the lowside MOSFETs. Check the gate charge losses of the synchronous rectifier(s) using the PG equation (Equation 9) to make sure they are reasonable. Rev. D | Page 17 of 32 ADP1823 VIN SETTING THE CURRENT LIMIT ADP1823 The current-limit comparator measures the voltage across the low-side MOSFET to determine the load current. Because the CSL current and the MOSFET RDSON vary over process and temperature, the minimum current limit should be set to ensure that the system can handle the maximum desired load current. To do this, use the peak current in the inductor, which is the desired current-limit level plus the ripple current, the maximum RDSON of the MOSFET at its highest expected temperature, and the minimum CSL current. RCL = I LPK R DSON ( MAX ) (15) 44 A where ILPK is the peak inductor current. In addition, the ADP1823 offers a technique for implementing a current-limit foldback in the event of a short circuit with the use of an additional resistor, as shown in Figure 25. Resistor RLO is largely responsible for setting the foldback current limit during a short circuit, and RHI is mainly responsible for setting up the normal current limit. RLO is lower than RHI. These current-limit sense resistors can be calculated by RLO = I PKFOLDBACK RDSON ( MAX ) RHI = VOUT 44 A I LPK RDSON ( MAX ) RLO (16) where: IPKFOLDBACK is the desired short-circuit peak inductor current limit. ILPK is the peak inductor current limit during normal operation (also used in Equation 15). L VOUT COUT M2 DL RLO RHI CSL Figure 25. Short-Circuit Current Foldback Scheme Because the buck converters are usually running fairly high current, PCB layout and component placement may affect the current-limit setting. An iteration of the RCL or RLO and RHI values may be required for a particular board layout and MOSFET selection. If alternate MOSFETs are substituted at some point in production, these resistor values may also need an iteration. FEEDBACK VOLTAGE DIVIDER The output regulation voltage is set through the feedback voltage divider. The output voltage is reduced through the voltage divider and drives the FB feedback input. The regulation threshold at FB is 0.6 V. The maximum input bias current into FB is 100 nA. For a 0.15% degradation in regulation voltage and with 100 nA bias current, the low-side resistor, RBOT, needs to be less than 9 k, which results in 67 A of divider current. For RBOT, use 1 k to 10 k. A larger value resistor can be used but results in a reduction in output voltage accuracy due to the input bias current at the FB pin, whereas lower values cause increased quiescent current consumption. Choose RTOP to set the output voltage by using the following equation: V - VFB RTOP = R BOT OUT VFB (17) - 44 A M1 05936-035 The current limit is set through the current-limit resistor, RCL. The current sense pins, CSL1 and CSL2, source 50 A through their respective RCL. This current source creates an offset voltage of RCL multiplied by the 50 A CSL current. When the drop across the low-side MOSFET RDSON is equal to or greater than this offset voltage, the ADP1823 flags a current-limit event. DH where: RTOP is the high-side voltage divider resistance. RBOT is the low-side voltage divider resistance. VOUT is the regulated output voltage. VFB is the feedback regulation threshold, 0.6 V. Rev. D | Page 18 of 32 (18) ADP1823 LC FILTER BODE PLOT COMPENSATING THE VOLTAGE MODE BUCK REGULATOR GAIN Assuming the LC filter design is complete, the feedback control system can then be compensated. Good compensation is critical to proper operation of the regulator. Calculate the quantities in Equation 19 through Equation 47 to derive the compensation values. The goal is to guarantee that the voltage gain of the buck converter crosses unity at a slope that provides adequate phase margin for stable operation. Additionally, at frequencies above the crossover frequency, fCO, guaranteeing sufficient gain margin and attenuation of switching noise are important secondary goals. For initial practical designs, a good choice for the crossover frequency is one tenth of the switching frequency. 0dB fSW AFILTER -20dB/dec PHASE 0 f SW 10 (19) -90 1 -180 Figure 26. LC Filter Bode Plot (20) 2 LC Generally, the LC corner frequency is about two orders of magnitude below the switching frequency, and, therefore, about one order of magnitude below crossover. To achieve sufficient phase margin at crossover to guarantee stability, the design must compensate for the two poles at the LC corner frequency with two zeros to boost the system phase prior to crossover. The two zeros require an additional pole or two above the crossover frequency to guarantee adequate gain margin and attenuation of switching noise at high frequencies. Depending on component selection, one zero may already be generated by the equivalent series resistance (ESR) of the output capacitor. Calculate this zero corner frequency, fESR, as 1 2 RESR COUT To compensate the control loop, the gain of the system must be brought back up so that it is 0 dB at the desired crossover frequency. Some gain is provided by the PWM modulation itself. V A MOD = 20 log IN V RAMP V AMOD = 20 log IN 1.3 V f AFILTER = -40 dB x log ESR f LC - 20 dB x log f CO f ESR (22) (23) (24) Note that if the converter is being synchronized, the ramp voltage, VRAMP, is lower than 1.3 V by the percentage of frequency increase over the nominal setting of the FREQ pin. 2 f FREQ VRAMP = 1.3 V f SYNC Figure 26 shows a typical Bode plot of the LC filter by itself. AFILTER = ALC + AESR For systems using the internal oscillator, this becomes (21) The gain of the LC filter at crossover can be linearly approximated from Figure 26 as 05936-025 FILTER The output LC filter is a resonant network that inflicts two poles upon the response at a frequency fLC, so next calculate f ESR = fCO -40dB/dec This gives sufficient frequency range to design a compensation that attenuates switching artifacts, while also giving sufficient control loop bandwidth to provide good transient response. f LC = fESR FREQUENCY First calculate f CO = fLC (25) The factor of 2 in the numerator takes into account that the SYNC frequency is divided by 2 to generate the switching frequency. For example, if the FREQ pin is set high for the 600 kHz range and a 2 MHz SYNC signal is applied, the ramp voltage is 0.78 V. The gain of the modulator is increased by 4.4 dB in this example. If fESR fCO, add another 3 dB to account for the local difference between the exact solution and the linear approximation. Rev. D | Page 19 of 32 ADP1823 The rest of the system gain is needed to reach 0 dB at crossover. The total gain of the system, therefore, is given by GAIN (26) 0dB where: AMOD is the gain of the PWM modulator. AFILTER is the gain of the LC filter including the effects of the ESR zero. ACOMP is the gain of the compensated error amplifier. fSW FREQUENCY -40dB/dec -20dB/dec Additionally, the phase of the system must be brought back up to guarantee stability. Note from the Bode plot of the filter that the LC contributes -180 of phase shift. Additionally, because the error amplifier is an integrator at low frequency, it contributes an initial -90. Therefore, before adding compensation or accounting for the ESR zero, the system is already down -270. To avoid loop inversion at crossover, or -180 phase shift, a good initial practical design is to require a phase margin of 60, which is therefore an overall phase loss of -120 from the initial low frequency dc phase. The goal of the compensation is to boost the phase back up from -270 to -120 at crossover. Two common compensation schemes are used, which are sometimes referred to as Type II or Type III compensation, depending on whether the compensation design includes two or three poles. (Dominant pole compensation, or single pole compensation, is referred to as Type I compensation, but unfortunately, it is not very useful for dealing successfully with switching regulators.) PHASE 0 1 -90 2 3 -180 Figure 27. LC Filter Bode Plot The following equations were used for the calculation of the compensation components as shown in Figure 28 and Figure 29: If the zero produced by the ESR of the output capacitor provides sufficient phase boost at crossover, Type II compensation is adequate. If the phase boost produced by the ESR of the output capacitor is not sufficient, another zero is added to the compensation network, and thus Type III is used. In Figure 27, the location of the ESR zero corner frequency gives significantly different net phase at the crossover frequency. Use the following guidelines for selecting between Type II and Type III compensators: If fESRZ fCO/2, use Type II compensation. If fESRZ > fCO/2, use Type III compensation. fLC fESR1 fESR2 fESR3 fCO 05936-026 AT = AMOD + AFILTER + ACOMP LC FILTER BODE PLOT PHASE CONTRIBUTION AT CROSSOVER OF VARIOUS ESR ZERO CORNERS f Z1 = 1 2RZ CI (27) f Z2 = 1 2C FF (RTOP + R FF ) (28) f P1 = 1 C I C HF 2R Z C I + C HF f P2 = 1 2R FF C FF where: fZ1 is the zero produced in the Type II compensation. fZ2 is the zero produced in the Type III compensation. fP1 is the pole produced in the Type II compensation. fP2 in the pole produced in the Type III compensation. Rev. D | Page 20 of 32 (29) (30) ADP1823 Type II Compensator PHASE Next choose the high frequency pole fP1 to be half of fSW. LO PE -1 S fZ LO PE 1 2RZ CHF f P1 = -270 CHF RZ (37) Solving for CHF in Equation 36 and Equation 37 yields CI CHF = RTOP EA VRAMP VREF 0V 1 f SW RZ (38) Type III Compensator TO PWM COMP -1 S G (dB) 05936-027 RBOT (36) Because CHF << CI, Equation 29 is simplified to fP -180 FROM VOUT 1 f SW 2 f P1 = Figure 28. Type II Compensation RZ = RTOPVRAMP f ESR fCO VIN f LC 2 RFF FROM VOUT (31) 1 RZ f LC fP CFF RZ CI RTOP RBOT EA COMP TO PWM VRAMP 0V Figure 29. Type III Compensation If the output capacitor ESR zero frequency is greater than half of the crossover frequency, use a Type III compensator as shown in Figure 29. Set the poles and zeros as follows: (32) f P1 = f P 2 = 1 f SW 2 (39) f Z1 = f Z 2 = fCO f 1 = SW = 4 40 2RZ CI (40) f Z1 = f Z 2 = f LC 1 = 2 2RZCI (41) (33) or (34) Use the lower zero frequency from Equation 40 or Equation 41. Calculate the compensator resistor, RZ. Solving for CI in Equation 33 yields CI = PE VREF Solving for CI in Equation 32 yields 20 CI = RZ f SW -1 SL O CHF or f 1 f Z1 = LC = 2 2RZ C I PE -270 Next choose the compensation capacitor to set the compensation zero, fZ1, to the lesser of 1/4 of the crossover frequency or 1/2 of the LC resonant frequency. fCO f 1 = SW = 4 40 2RZ CI LO PHASE where: fCO is chosen to be 1/10 of fSW. VRAMP is 1.3 V. f Z1 = S +1 PE fZ -90 If the output capacitor ESR zero frequency is sufficiently low (1/2 of the crossover frequency), use the ESR to stabilize the regulator. In this case, use the circuit shown in Figure 28. Calculate the compensation resistor, RZ, with the following equation: LO 05936-028 G (dB) -1 S RZ = (35) Use the larger value of CI from Equation 34 or Equation 35. Because of the finite output current drive of the error amplifier, CI needs to be less than 10 nF. If it is larger than 10 nF, choose a larger RTOP and recalculate RZ and CI until CI is less than 10 nF. RTOPVRAMP f Z1 fCO VIN f LC 2 (42) Next calculate CI. Rev. D | Page 21 of 32 CI = 1 2RZ f Z1 (43) ADP1823 Because of the finite output current drive of the error amplifier, CI needs to be less than 10 nF. If it is larger than 10 nF, choose a larger RTOP and recalculate RZ and CI until CI is less than 10 nF. The soft start period ends when the voltage on the soft start pin reaches 0.6 V. Substituting 0.6 V for VSS and solving for the number of RC time constants Because CHF << CI, combining Equation 29 and Equation 39 yields 1 (44) f SW RZ Next calculate the feedforward capacitor, CFF. Assuming RFF << RTOP, then Equation 28 is simplified to fZ2 = (45) 2CFF RTOP tSS = 1.386 RCSS 1 (46) 2RTOP f Z 2 The feedforward resistor, RFF, can be calculated by combining Equation 30 and Equation 39. 1 (47) CFF f SW Check that the calculated component values are reasonable. For instance, capacitors smaller than about 10 pF should be avoided. In addition, the ADP1823 error amplifier has finite output current drive; therefore, RZ values less than 3 k and CI values greater than 10 nF should be avoided. If necessary, recalculate the compensation network with a different starting value of RTOP. If RZ is too small and CI is too big, start with a larger value of RTOP. This compensation technique should yield a good working solution. In general, aluminum electrolytic capacitors have high ESR; therefore, a Type II compensation is adequate. However, if several aluminum electrolytic capacitors are connected in parallel, producing a low effective ESR, Type III compensation is needed. In addition, ceramic capacitors have very low ESR, on the order of a few milliohms; therefore, Type III compensation is needed for ceramic output capacitors. Type III compensation offers better performance than Type II in terms of more low frequency gain and more phase margin and less high frequency gain at the crossover frequency. Because R = 90 k, (51) where tSS is the desired soft start time in seconds. The ADP1823 includes a tracking feature that prevents an output voltage from exceeding a master voltage. This feature is especially important when the ADP1823 is powering separate power supply voltages on a single integrated circuit, such as the core and I/O voltages of a DSP or microcontroller. In these cases, improper sequencing can cause damage to the load. The ADP1823 tracking input is an additional positive input to the error amplifier. The feedback voltage is regulated to the lower of the 0.6 V reference or the voltage at TRK; therefore, a lower voltage on TRK limits the output voltage. This feature allows implementation of two different types of tracking: coincident tracking, where the output voltage is the same as the master voltage until the master voltage reaches regulation, or ratiometric tracking, where the output voltage is limited to a fraction of the master voltage. In all tracking configurations, the master voltage should be higher than the slave voltage. Note that the soft start time setting of the master voltage should be longer than the soft start of the slave voltage. This forces the rise time of the master voltage to be imposed on the slave voltage. If the soft start setting of the slave voltage is longer, the slave comes up more slowly and the tracking relationship is not seen at the output. The slave channel should still have a soft start capacitor to give a small but reasonable soft start time to protect in case of a restart after a current-limit event. VOUT RTOP COMP SOFT START The ADP1823 uses an adjustable soft start to limit the output voltage ramp-up period, thus limiting the input inrush current. The soft start is set by selecting the capacitor, CSS, from SS1 and SS2 to GND. The ADP1823 charges CSS to 0.8 V through an internal 90 k resistor. The voltage on the soft start capacitor while it is charging is t RC SS VCSS = 0.8 V 1 - e (50) VOLTAGE TRACKING where fZ2 is obtained from Equation 40 or Equation 41. RFF = (49) CSS = tSS x 8 F/s 1 Solving CFF in Equation 45 yields CFF = RBOT FB TRK ERROR AMPLIFIER SS DETAIL VIEW OF ADP1823 (48) Rev. D | Page 22 of 32 MASTER VOLTAGE 0.6V Figure 30. Voltage Tracking RTRKT RTRKB 05936-029 CHF = t SS 0.6 V = 0.8 V 1 - e 90 k ( CSS) ADP1823 COINCIDENT TRACKING The most common application is coincident tracking, used in core vs. I/O voltage sequencing and similar applications. Coincident tracking limits the slave output voltage to be the same as the master voltage until it reaches regulation. Connect the slave TRK input to a resistor divider from the master voltage that is the same as the divider used on the slave FB pin. This technique forces the slave voltage to be the same as the master voltage. For coincident tracking, use RTRKT = RTOP and RTRKB = RBOT, where RTOP and RBOT are the values chosen in the Compensating the Voltage Mode Buck Regulator section. B SLAVE VOLTAGE TIME A more accurate solution is to provide a divider from the master voltage that sets the TRK pin voltage to be something lower than 0.6 V at regulation, for example, 0.5 V. The slave channel can be viewed as having a 0.5 V external reference supplied by the master voltage. Once this is complete, the FB divider for the slave voltage is designed as in the Compensating the Voltage Mode Buck Regulator section, except to substitute the 0.5 V reference for the VFB voltage. The ratio of the slave output voltage to the master voltage is a function of the two dividers: 05936-030 VOLTAGE MASTER VOLTAGE For ratiometric tracking, the simplest configuration is to tie the TRK pin of the slave channel to the FB pin of the master channel. This has the advantage of having the fewest components, but the accuracy suffers as the TRK pin voltage becomes equal to the internal reference voltage and an offset is imposed on the error amplifier of about -18 mV at room temperature. VOUT Figure 31. Coincident Tracking As the master voltage rises, the slave voltage rises identically. Eventually, the slave voltage reaches its regulation voltage, where the internal reference takes over the regulation while the TRK input continues to increase and thus removes itself from influencing the output voltage. To ensure that the output voltage accuracy is not compromised by the TRK pin being too close in voltage to the 0.6 V reference, make sure that the final value of the master voltage is greater than the slave regulation voltage by at least 10%, or 60 mV as seen at the FB node. The higher the final value, the better the performance is. A difference of 60 mV between TRK and the 0.6 V reference produces about 3 mV of offset in the error amplifier, or 0.5%, at room temperature, while 100 mV between them produces only 0.6 mV or 0.1% offset. RATIOMETRIC TRACKING Ratiometric tracking limits the slave output voltage to a fraction of the master voltage. For example, the termination voltage for DDR memories, VTT, is set to half the VDD voltage. V MASTER (52) By selecting the resistor values in the divider carefully, Equation 52 shows that the slave voltage output can be made to have a faster ramp rate than that of the master voltage by setting the TRK voltage at the slave larger than 0.6 V and RTRKB greater than RTRKT. Make sure that the master SS period is long enough (that is, sufficiently large SS capacitor) such that the input inrush current does not run into the current limit of the power supply during startup. SLAVE VOLTAGE 05936-031 VOLTAGE RTRKT RTRKB RTOP R BOT Another option is to add another tap to the divider for the master voltage. Split the RBOT resistor of the master voltage into two pieces, with the new tap at 0.5 V when the master voltage is in regulation. This technique saves one resistor, but be aware that Type III compensation on the master voltage causes the feedforward signal of the master voltage to appear at the TRK input of the slave channel. MASTER VOLTAGE TIME 1 + = 1 + Figure 32. Ratiometric Tracking Rev. D | Page 23 of 32 ADP1823 Setting the Channel 2 Undervoltage Threshold for Ratiometric Tracking THERMAL CONSIDERATIONS If FB2 is regulated to a voltage lower than 0.6 V by configuring TRK2 for ratiometric tracking, the Channel 2 undervoltage threshold can be set appropriately by splitting the top resistor in the voltage divider, as shown in Figure 33. RBOT is the same as calculated for the compensation in Equation 52, and RTOP = RA + RB The current required to drive the external MOSFETs comprises the vast majority of the power dissipation of the ADP1823. The on-chip LDO regulates down to 5 V, and this 5 V supplies the drivers. The full gate drive current passes through the LDO and is then dissipated in the gate drivers. The power dissipated on the gate drivers on the ADP1823 is (53) B CHANNEL 2 OUTPUT VOLTAGE UV2 RA The power dissipation heats the ADP1823. As the switching frequency, the input voltage, and the MOSFET size increase, the power dissipation on the ADP1823 increases. Care must be taken not to exceed the maximum junction temperature. To calculate the junction temperature from the ambient temperature and power dissipation POK2 RB FB2 RBOT 05936-032 750mV TJ = TA + PD JA Figure 33. Setting the Channel 2 Undervoltage Threshold The current in all the resistors is the same. V V - VFB 2 - VUV 2 VFB 2 = UV 2 = OUT 2 RBOT RB RA (54) where: VUV2 is 600 mV. VFB2 is the feedback voltage value set during the ratiometric tracking calculations. VOUT2 is the Channel 2 output voltage. A thermal shutdown protection circuit on the ADP1823 shuts off the LDO and the controllers if the die temperature exceeds approximately 145C, but this is a gross fault protection only and should not be relied upon for system reliability. B R B = R BOT (VOUTA2 - VUV 2 ) (V VFB 2 UV 2 - VFB 2 ) VFB 2 (58) The thermal resistance, JA, of the package is typically 40C/W depending on board layout, and the maximum specified junction temperature is 125C, which means that at a maximum ambient temperature of 85C without airflow, the maximum dissipation allowed is about 1 W. Solving for RA and RB, R A = RBOT (57) where: VIN is the voltage applied to IN. fSW is the switching frequency. Q numbers are the total gate charge specifications from the selected MOSFET data sheets. 550mV TO ERROR AMPLIFIER PD = VIN fSW(QDH1 + QDL1 + QDH2 + QDL2) (55) (56) Rev. D | Page 24 of 32 ADP1823 PCB LAYOUT GUIDELINES In any switching converter, some circuit paths carry high dI/dt, which can create spikes and noise. Other circuit paths are sensitive to noise. Still others carry high dc current and can produce significant IR voltage drops. The key to proper PCB layout of a switching converter is to identify these critical paths and arrange the components and copper area accordingly. When designing PCB layouts, be sure to keep high current loops small. In addition, keep compensation and feedback components away from the switch nodes and their associated components. * Avoid long traces or large copper areas at the FB and CSL pins, which are low signal level inputs that are sensitive to capacitive and inductive noise pickup. It is best to position any series resistors and capacitors as close as possible to these pins. Avoid running these traces close and parallel to high dI/dt traces. * The switch node is the noisiest place in the switcher circuit with large ac and dc voltage and current. This node should be wide to minimize resistive voltage drop. However, to minimize the generation of capacitively coupled noise, the total area should be small. Place the FETs and inductor all close together on a small copper plane to minimize series resistance and keep the copper area small. * Gate drive traces (DH and DL) handle high dI/dt and, therefore, they tend to produce noise and ringing. They should be as short and direct as possible. If possible, avoid using feedthrough vias in the gate drive traces. If vias are needed, it is best to use two relatively large ones in parallel to reduce the peak current density and the current in each via. If the overall PCB layout is less than optimal, slowing down the gate drive slightly can be very helpful to reduce noise and ringing. It is occasionally helpful to place small value resistors (such as 5 or 10 ) in series with the gate leads, mainly DH traces to the high-side FET gates. These can be populated with 0 resistors if resistance is not needed. Note that the added gate resistance increases the switching rise and fall times and that in turn increases the switching power loss in the MOSFET. * The negative terminal of output filter capacitors should be tied closely to the source of the low-side FET. Doing this helps to minimize voltage difference between GND and PGND at the ADP1823. * Generally, be sure that all traces are sized according to the current to be handled as well as their sensitivity in the circuit. Standard PCB layout guidelines mainly address heating effects of current in a copper conductor. These are completely valid, but they do not fully cover other concerns, such as stray inductance or dc voltage drop. Any dc voltage differential in connections between ADP1823 GND and the converter power output ground can cause a significant output voltage error, because it affects converter output voltage according to the ratio with the 600 mV feedback reference. For example, a 6 mV offset between ground on the ADP1823 and the converter power output causes a 1% error in the converter output voltage. The following is a list of recommended layout practices for the ADP1823, arranged by decreasing order of importance. * * * The current waveform in the top and bottom FETs is a pulse with very high dI/dt; therefore, the path to, through, and from each individual FET should be as short as possible and the two paths should be commoned as much as possible. In designs that use a pair of D-Pak or SO-8 FETs on one side of the PCB, it is best to counter-rotate the two so that the switch node is on one side of the pair and the high-side drain can be bypassed to the low-side source with a suitable ceramic bypass capacitor, placed as close as possible to the FETs to minimize inductance around this loop through the FETs and capacitor. The recommended bypass ceramic capacitor values range from 1 F to 22 F depending upon the output current. This bypass capacitor is usually connected to a larger value bulk filter capacitor and should be grounded to the PGND plane. GND, the VREG bypass, the soft start capacitor, and the bottom end of the output feedback divider resistors should be tied to an (almost isolated) small AGND plane. All of these connections should have connections from the pin to the AGND plane that are as short as possible. No high current or high dI/dt signals should be connected to this AGND plane. The AGND area should be connected through one wide trace to the negative terminal of the output filter capacitors. The PGND pin handles high dI/dt gate drive current returning from the source of the low-side MOSFET. The voltage at this pin also establishes the 0 V reference for the overcurrent limit protection (OCP) function and the CSL pin. A small PGND plane should connect the PGND pin and the PVCC bypass capacitor through a wide and direct path to the source of the low-side MOSFET. The placement of CIN is critical for controlling ground bounce. The negative terminal of CIN needs to be placed very close to the source of the low-side MOSFET. Rev. D | Page 25 of 32 ADP1823 LFCSP CONSIDERATIONS * The paste mask for the thermal pad needs to be designed for the maximum coverage to effectively remove the heat from the package. However, due to the presence of thermal vias and the large size of the thermal pad, eliminating voids may not be possible. In addition, if the solder paste coverage is too large, solder joint defects may occur. Therefore, it is recommended to use multiple small openings over a single big opening in designing the paste mask. The recommended paste mask pattern is given in Figure 36. This pattern results in about 80% coverage, which should not degrade the thermal performance of the package significantly. * The recommended paste mask stencil thickness is 0.125 mm. A laser cut stainless steel stencil with trapezoidal walls should be used. * A no-clean, Type 3 solder paste should be used for mounting the LFCSP. In addition, a nitrogen purge during the reflow process is recommended. * The package manufacturer recommends that the reflow temperature should not exceed 220C and the time above liquid is less than 75 seconds. The preheat ramp should be 3C per second or lower. The actual temperature profile depends on the board density; the assembly house must determine what works best. The LFCSP has an exposed die paddle on the bottom that efficiently conducts heat to the PCB. To achieve the optimum performance from the LFCSP, give special consideration to the layout of the PCB. Use the following layout guidelines for the LFCSP: * The pad pattern is given in Figure 36. The pad dimension should be followed closely for reliable solder joints while maintaining reasonable clearances to prevent solder bridging. * The thermal pad of the LFCSP provides a low thermal impedance path to the PCB. Therefore, the PCB must be properly designed to effectively conduct the heat away from the package. This is achieved by adding thermal vias to the PCB, which provide a thermal path to the inner or bottom layers. See Figure 36 for the recommended via pattern. Note that the via diameter is small, which prevents the solder from flowing through the via and leaving voids in the thermal pad solder joint. Note that the thermal pad is attached to the die substrate; therefore, the planes that the thermal pad is connected to must be electrically isolated or connected to GND. * The solder mask opening should be about 120 microns (4.7 mils) larger than the pad size, resulting in a minimum 60 microns (2.4 mils) clearance between the pad and the solder mask. * The paste mask opening is typically designed to match the pad size used on the peripheral pads of the LFCSP. This technique should provide a reliable solder joint as long as the stencil thickness is about 0.125 mm. Rev. D | Page 26 of 32 ADP1823 APPLICATION CIRCUITS The ADP1823 controller can be configured to regulate outputs with loads of more than 20 A if the power components, such as the inductor, MOSFETs, and the bulk capacitors, are chosen carefully to meet the power requirement. The maximum load and power dissipation are limited by the powertrain components. Figure 1 shows a typical application circuit that can drive an output load of 8 A. can also be paralleled up at the input or output to meet the ripple current requirement. Because the aluminum electrolytic capacitors have higher ESR and much larger variation in capacitance over the operating temperature range, a larger bulk input and output capacitance is needed to reduce the effective ESR and suppress the current ripple. Figure 34 shows that the polymer aluminum or the aluminum electrolytic capacitors can be used at the outputs. Figure 34 shows an application circuit that can drive 20 A loads. Note that two low-side MOSFETs are needed to deliver the 20 A load. The bulk input and output capacitors used in this example are Sanyo OS-CON capacitors, which have low ESR and high current ripple rating. An alternative to the OS-CON capacitors are the polymer aluminum capacitors that are available from other manufacturers, such as United Chemi-Con. Aluminum electrolytic capacitors, such as the Rubycon ZLG low-ESR series, IN = 5.5V TO 20V 1F L2 1H 1.2V, 20A COUT2 820F 25V x2 1F D2 1F 0.47F M4 5600pF 390 D1 BST1 BST2 DH1 DH2 1F 0.47F M5 SW2 CSL2 SW1 CSL1 DL1 2k FB1 FB2 COMP1 10k 1.8V, 20A 10nF M2 M3 2k PGND1 PGND2 120nF L1 1H 2k DL2 2k CIN1 180F 20V PGND M1 ADP1823 2k M6 EN1 EN2 200 1F COUT1 1200F 6.3V x3 1.5nF 1k COMP2 4.7nF FREQ 47k 6.8nF LDOSD GND SYNC AGND fOSC = 300kHz M1, M4: IRLR7807Z L1, L2: TOKO, FDA1254-1ROM COUT1: SANYO, 2R5SEPC820M D1, D2: VISHAY, BAT54 M2, M3, M5, M6: IRFR3709Z CIN1, CIN2: SANYO, 20SP180M COUT2: RUBYCON, 6.3ZLG1200M10x16 Figure 34. Application Circuit with 20 A Output Loads Rev. D | Page 27 of 32 05936-033 CIN2 180F 20V PV IN TRK1 TRK2 VREG ADP1823 The ADP1823 can also be configured to drive an output load of less than 1 A. Figure 35 shows a typical application circuit that drives 1.5 A and 3 A loads in all multilayer ceramic capacitor (MLCC) solutions. Notice that the two MOSFETs used in this example are dual-channel MOSFETs in a PowerPAK(R) SO-8 package, which reduces cost and saves layout space. An alternative to using the dual-channel SO-8 package is using two single MOSFETs in SOT-23 or TSOP-6 packages, which are low cost and small in size. IN = 3.7V TO 5V 1F 10F x2 D2 1F 0.22F L2 2.2H 1.0V, 3A COUT2 47F EN1 EN2 D1 BST1 BST2 DH1 DH2 4.12k 8.2nF 84.5 0.22F M4 1.33k L1 2.5H 1.8V, 1.5A SW2 CSL1 CSL2 DL1 1.4k 8.2nF FB1 FB2 1F 10F COUT1 100F M2 DL2 2k PGND1 PGND2 120nF 10F x2 PGND M1 ADP1823 SW1 1F 1F 84.5 120nF 2k 1k COMP1 COMP2 6.65k 1.5nF FREQ 6.65k 1.5nF IN LDOSD GND fOSC = 600kHz SYNC AGND M1 TO M4: DUAL-CHANNEL SO-8 IRF7331 L2: TOKO, FDV0602-2R2M COUT2: MURATA, GRM31CR60J476M L1: SUMIDA, CDRH5D28-2R5NC COUT1, COUT3: MURATA, GRM31CR60J107M D1, D2: VISHAY BAT54 Figure 35. Application Circuit with All Multilayer Ceramic Capacitors (MLCC) Rev. D | Page 28 of 32 05936-034 COUT3 100F M3 PV IN TRK1 TRK2 VREG ADP1823 OUTLINE DIMENSIONS 0.60 MAX 5.00 BSC SQ 0.60 MAX PIN 1 INDICATOR TOP VIEW 0.50 BSC 4.75 BSC SQ 0.50 0.40 0.30 32 1 3.25 3.10 SQ 2.95 EXPOSED PAD (BOTTOM VIEW) 17 16 9 8 0.25 MIN 3.50 REF 0.80 MAX 0.65 TYP 12 MAX 1.00 0.85 0.80 PIN 1 INDICATOR 25 24 0.05 MAX 0.02 NOM SEATING PLANE 0.30 0.23 0.18 0.20 REF COPLANARITY 0.08 COMPLIANT TO JEDEC STANDARDS MO-220-VHHD-2 Figure 36. 32-Lead Lead Frame Chip Scale Package [LFCSP_VQ] 5 mm x 5 mm Body, Very Thin Quad (CP-32-2) Dimensions shown in millimeters ORDERING GUIDE Model ADP1823ACPZ-R7 2 ADP1823-EVAL 1 2 Temperature Range 1 -40C to +85C Package Description 32-Lead Lead Frame Chip Scale Package [LFCSP_VQ] Evaluation Board Operating junction temperature is -40C to +125C. Z = RoHS Compliant Part. Rev. D | Page 29 of 32 Package Option CP-32-2 ADP1823 NOTES Rev. D | Page 30 of 32 ADP1823 NOTES Rev. D | Page 31 of 32 ADP1823 NOTES (c)2006-2007 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D05936-0-10/07(D) Rev. D | Page 32 of 32