02/05/2002 Advanced Power Solutions UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC SINGLE OUTPUT 100 WATTS INDUSTRIAL DIN RAIL SWITCHING POWER SUPPLIES APS100PD SERIES FEATURES: ! ACCOMMODATES UNIVERSAL AC INPUT ! MEETS IEC1000-3-2 HARMONIC CORRECTION ! MEETS UNIVERSAL SAFETY STANDARDS AND INDUSTRIAL UL508 ! INDUSTRIAL POWER SUPPLIES FOR SNAP-ON MOUNTING ON DIN-RAILS ! EMI MEETS EN 55022 CLASS B ! CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typ. 90-264Vac universal AC input Input Connector: Phoenix GMSTBA2.5/3-G-7.62 Input Frequency: 47-63 Hz Inrush Current: Typ. 25A @230Vac Input Current: 1.1A @115Vac/ 0.55A @230Vac Dielectric Withstand: Meets IEC950 EMI: Meet EN55022/FCC Class B Power Factor Correction: Meets Harmonic Correction per IEC1000-3-2. PF typ. 0.96-0.98 No Load Operation: No damage Hold-up Time: Typ. 46mS @115Vac & 230Vac Earth Leakage: Less than 0.70mA @ 230Vac Output Voltage: See Ratings Chart Output Current: See Ratings Chart Output Wattage: Typ. 100W continuous Output Connector: Phoenix MSTBA2.5/4-G-5.08 Line Regulation: Typ. 0.1% Load Regulation: Typ. 1.0-1.5% typical Noise & Ripple: Typ. 1.0% peak to peak OVP: Option for Built-in Remote Sense: Option Adjustment: Available Overload Protection (OLP): Fully protected against output overload and short circuit Consult the factory for OLP setting LED Indicator: Installed GENERAL SPECIFICATION Efficiency: Typ. 82% Switching Frequency: Fixed freq. 66.6KHz Circuit Topology: Fixed frequency forward circuit Transient Response: Output voltage returns in less than 3mS following a 25% load change Safety Standard: IEC950/UL1950 Class I Power Density: 2.76 Watt / Cubic inch Industrial Grade UL 508 Operating Temperature: -10 to +70C at full load (> +60C: by de-rating 2% / C) Storage Temperature: -25 to +85C Temperature Coefficient: 0.03% / C Cooling: Free air convection cooling for Temp. < +60C Moving air is request for Temp. > +60C full load operation Construction format: Enclosure metal box format with DIN-clips Note: (1) All measurements are at nominal input, full load, and +25C unless otherwise specified. (2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (unit %). 02/05/2002 OUTPUT VOLTAGE/CURRENT RATINGS CHART SINGLE OUTPUT MODEL NO. APS100PD-S120083 APS100PD-S240042 APS100PD-S480022 MAIN O/P @(*)(#) Typ. Volt. 8.3A 12.0V 4.2A 24.0V 2.2A 48.0V Symbol: "@" Adjustable. "(*)" OVP for option. "(#)" Remote sensing for option. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 0.67kg (23.5 Oz.) INPUT & OUTPUT CONNECTORS PIN ASSIGNMENTS AC INPUT ASSIGNMENT AC-L AC-N AC-G P1-3. P1-2. P1-1. CONNECTOR & PIN # Mating connector: P1: Phoenix GMSTB2.5/3-ST-7.62 P2: Phoenix MSTB2.5/4-ST-5.08 SINGLE OUTPUT VO1 DC-COM P2-3, 4. P2-1, 2.