02/05/2002
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC
SINGLE OUTPUT 100 WATTS INDUSTRIAL DIN RAIL SWITCHING
POWER SUPPLIES APS100PD SERIES
Advanced Power Solutions
FEATURES:
! ACCOMMODATES UNIVERSAL AC INPUT
! MEETS IEC1000-3-2 HARMONIC CORRECTION
! MEETS UNIVERSAL SAFETY STANDARDS AND
INDUSTRIAL UL508
! INDUSTRIAL POWER SUPPLIES FOR SNAP-ON
MOUNTING ON DIN-RAILS
! EMI MEETS EN 55022 CLASS B
!
CE MARKING COMPLIANCE
OUTPUT SPECIFICATION
Output Voltag e : See Ratings Chart
Output Current: See Ratings Chart
Output Wattage: Typ. 100W continuous
Output Connecto r : Phoenix MSTBA2.5/4-G-5.08
Line Regulation: Typ. 0.1%
Load Regulation: Typ. ±1.0-1.5% typical
Noise & Ripple: Typ. 1.0% peak to peak
OVP: Option for Built-in
Remote Sense: Option
Adjustment: Available
Overload Protection (OLP): Fully protected against
output overload and short circuit
Consult the factory for OLP setting
LED Indicator: Installed
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac universal AC input
Input Connector: Phoenix GMSTBA2.5/3-G-7.62
Input Frequency: 47-63 Hz
Inrush Current: Typ. 25A @230Vac
Input Current: 1.1A @115Vac/ 0.55A @230Vac
Dielectric Withstand: Meets IEC950
EMI: Meet EN55022/FCC Class B
Power Factor Correction: Meets Harmonic Correction
per IEC1000-3-2. PF typ. 0.96-0.98
No Load Operation: No damage
Hold-up Time: Typ. 46mS @115Vac & 230Vac
Earth Leakage: Less than 0.70mA @ 230Vac
GENERAL SPECIFICATION
Efficiency: Typ. 82%
Switching Frequency: Fixed freq. 66.6KHz
Circuit Topology: Fixed frequency forward cir cuit
Transient Response: Output voltage returns in
less than 3mS following
a 25% load change
Safety Standard: IEC950/UL1950 Class I
Power Density: 2.76 Watt / Cubic inch
Industrial Grade UL 508
Operating Temperature: -10 to +70°C at full load
(> +60°C: by de-rating 2% / °C)
Storage Temperature: -25 to +85°C
Temperature Coefficient: 0.03% / °C
Cooling: Free air convection cooling for Temp. < +60°C
Moving air is request for Temp. > +60°C
full load operation
Construction format: Enclosure metal box format
with DIN-clips
Note: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to
full load (un it ± %).
02/05/2002
OUTPUT V OLTAGE/CURRENT RATINGS CHART
MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 0.67kg (23.5 Oz.)
SINGLE OUTPUT MAIN O/P @()(#)
MODEL NO. Typ. Volt.
APS100PD-S120083 8.3A 12.0V
APS100PD-S240042 4.2A 24.0V
APS100PD-S480022 2.2A 48.0V
Symbol: "@" Adjustable. "()" OVP for option.
"(#)" Remote sensing for opt ion.
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENTS
AC INPUT SINGLE OUTPUT
ASSIGNMENT AC-L AC-N AC-G VO1 DC-COM
CONNECTOR & PIN # P1-3. P1-2. P1-1. P2-3, 4. P2-1, 2.
Mating connector: P1: Phoenix GMSTB2.5/3-ST-7.62
P2: Phoenix MSTB2.5/4-ST-5.08