green 1. Use the green knife cassette 6GK1901-1GB01 (5.1 mm knife clearance) in the stripping tool. If your stripping tool was supplied with a yellow knife cassette, the cutting depth must be adjusted with the middle sockethead screw after fitting the new cassette! 2. Take the stripping tool in your right hand. 3. Measure the cable length against the measuring template. Use your left index finger as the limit stop. 4. Insert the cable into the stripping tool. Your left index finger is the limit stop. 5. Tighten the stripping tool fully. 6. To strip the insulation, turn the tool in the direction of the arrow - approx. 4 times for PVC insulation, - approx, 8 times for PUR insulation. 7. Keeping the stripping tool closed, pull it off the end of the cable along with the jacket and remnants of the shield. 8. If the white filler is not removed with the insulation, remove it and the transparent protective foil with your hand. 9. Cut off the dummy cores. 11. Insert the wires into the contact elements of the FC RJ45 plug as far as the limit stop. 12. Push the cable into position as shown in the picture (see arrows). Press down the contact elements as far as the limit stop to contact the wires. 18 5 10. Spread out the wires according to the color markings on the contact elements of the FC RJ45 plug. o 90 13. Close the cover and turn the locking mechanism in the direction of the arrow as far as possible with your hand. 14. Insert a 2.5 mm screwdriver into the hole in the locking mechanism and turn it as far as the limit stop. 15. The connector is correctly locked when the opening of the locking mechanism is pointing to the side and the surfaces are flush with the surface of the connector. 16. If there is little space, release the connector catch with a screwdriver (2.5 mm blade width). The piercing contacts of the FC RJ45 plug can be released and recontacted up to 10 times. Cable ends that have already been pierced must not be used again but must be cut off. Don't pull while unlocking the plug. To create a crossover cable, combine the wires in the connector at one end according to the following scheme: Connect white with yellow Connect blue with orange. Notes: Replace the knife cassette if the cut edges become ragged or after approx.* * 1500 operations on cables with PVC outer jackets* * 150 operations on cables with PUR outer jackets You will find information on network structures in the SIMATIC NET Industrial Ethernet Networking Manual SIMATIC NET Produktinformation Product Information A5E00328643 Stand / Dated / 02/2010 Montageanleitung fur / Assembly Instructions for SIMATIC NET Industrial Ethernet FastConnect RJ45 Plug 90 6GK1901-1BB20-2A.. Nachfolgend finden Sie Informationen in deutscher Sprache. Die aktuellen Hinweise finden Sie auf folgender Internetseite: http://support.automation.siemens.com "Produktsupport". You will find information below in English. You will find the latest information on the following Internet page: http://support.automation.siemens.com "Product Support". A5E00328643 (c) SIEMENS AG 2010 Anderungen vorbehalten Subject to change Wir haben den Inhalt der Druckschrift auf Uber-einstimmung mit dem Weitergabe sowie Vervielfaltigung dieser Unterlage, Verwertung und beschriebenen Werkzeug gepruft. Dennoch konnen Abweichungen Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdrucklich nicht ausgeschlossen werden, so da wir fur die vollstandige zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Ubereinstimmung keine Gewahr ubernehmen. Die Angaben in der Alle Rechte vorbehalten, insbesondere fur den Fall der Druckschrift werden jedoch regelmaig uberpruft. Notwendige Patenterteilung oder GM-Eintragung. Korrekturen sind in den nachfolgenden Auflagen enthalten. Fur Copyright (c) Siemens AG 2010 Verbesserungsvorschlage sind wir dankbar. Technische Anderungen vorbehalten. All Rights Reserved Wichtiger Hinweis Wir weisen darauf hin, da der Inhalt dieser Betriebsanleitung nicht Teil einer fruheren oder bestehenden Vereinbarung, Zusage oder eines Rechtsverhaltnisses ist oder diese abandern soll. Samtliche Verpflichtungen von Siemens ergeben sich aus dem jeweiligen Kaufvertrag, der auch die vollstandige und allein gultige Gewahrleistungsregel enthalt. Diese vertraglichen Gewahrleistungsbestimmungen werden durch die Ausfuhrungen dieser Betriebsanleitung weder erweitert noch beschrankt. Wir weisen auerdem darauf hin, da aus Grunden der Ubersichtlichkeit in dieser Betriebsanleitung nicht jede nur erdenkliche Problemstellung im Zusammenhang mit dem Einsatz dieses Werkzeugs beschrieben werden kann. Sollten Sie weitere Informationen benotigen oder sollten besondere Probleme auftreten, die in der Betriebsanleitung nicht ausfuhrlich genug behandelt werden, konnen Sie die erforderliche Auskunft uber die ortliche Siemens-Niederlassung anfordern. WARNUNG ! Das in der Anleitung beschriebene Werkzeug ist nur fur das Abisolieren der SIMATIC NET Industrial Ethernet FastConnect Leitungen bestimmt. Bei anderweitiger Verwendung kann es zu Unfallen oder zur Zerstorung von Werkzeug und Leitung kommen. Das Werkzeug darf auf keinen Fall an Leitungen die unter Spannung stehen benutzt werden. Weitere Informationen zum Netzaufbau finden Sie im SIMATIC NET Industrial Ethernet Netzhandbuch Anforderung an die Qualifikation des Personals Qualifiziertes Personal im Sinne dieser Betriebsanleitung bzw. der Warnhinweise sind Personen, die mit Aufstellung, Montage, Inbetriebsetzung und Betrieb dieses Produktes vertraut sind und uber die ihrer Tatigkeit entsprechenden Qualifikation verfugen und in erster Hilfe geschult sind. _________________________________________________________________________________ We have checked the contents of this manual for agreement with this The reproduction, transmission or use of this document or its tool described. Since deviations cannot be precluded entirely, we contents is not permitted without express written authority. Offenders cannot guarantee full agreement. However, the data in this manual will be liable for damages. All rights, including rights created by patent grant or registration of a utility or design, are reserved. are reviewed regularly and any necessary corrections included in subsequent editions.Suggestions for improvement are welcome. Technical data subject to change. Copyright (c) Siemens AG 2010 All Rights Reserved Note We would point out that the contents of this product documentation shall not become a part of or modify any prior or existing agreement, commitment or legal relationship. The Purchase Agreement contains the complete and exclusive obligations of Siemens. Any statements contained in this documentation do not create new warranties or restrict the existing warranty. We would further point out that, for reasons of clarity, these operating instructions cannot deal with every possible problem arising from the use of this device. Should you require further information or if any special problems arise which are not sufficiently dealt with in the operating instructions, please contact your local Siemens representative. WARNING ! The tool and plug-in connector described in the manual must only be used in conjunction with SIMATIC NET Industrial Ethernet FastConnect cables. If used elsewhere, accidents may occur or tools, connector and cable may be irreparably damaged. The tool and plug-in connector must not be used on live cables under any circumstances. CL/CSA-Rating The units are intended for communication circuits operating at 175 mA or less and a maximum 56.5 V dc, ringing voltage not to exceed 150 Vrms or for data circuits operating at 30 V ac, 42 V dc, 100 mA. For more detailed information on setting up networks, refer to the SIMATIC NET Industrial Ethernet Network Manual Personnel qualification requirements Qualified personnel as referred to in the operating instructions or in the warning notes are defined as persons who are familiar with the installation, assembly, startup and operation of this product and who possess the relevant qualifications for their work and have a First Aid qualification. grun 1. Verwenden Sie im Abisolierwerkzeug die grune Messerkassette 6GK1901-1GB01 (5,1 mm Messerabstand)! Bei Abisolierwerkzeugen, die mit gelber Messerkassette ausgeliefert wurden, ist nach dem Austausch der Messerkassette mit der mittleren Imbusschraube die Schnitttiefe zu justieren! 2. Nehmen Sie das Abisolierwerkzeug in die rechte Hand. 3. Messen Sie die Leitungslange durch Anlegen der Leitung an die Maschablone ab. Benutzen Sie den Zeigefinger der linken Hand als Anschlag. 4. Legen Sie die Leitung in das Abisolierwerkzeug ein. Der Zeigefinger der linken Hand bildet den Anschlag. 5. Spannen Sie das Abisolierwerkzeug bis zum Anschlag. 6. Drehen Sie das Abisolierwerkzeug zum Abisolieren der Leitung bei -PVC-Isolierung ca. 4 mal, bei -PUR-Isolierung ca. 8 mal in Pfeilrichtung. 7. Ziehen Sie das Abisolierwerkzeug im geschlossenen Zustand mit den Mantelund Schirmresten vom Leitungsende ab. 8. Falls beim Abisolieren die weie Fullmasse nicht mit abgezogen wurde, entfernen Sie diese ebenso wie die transparente Schutzfolie durch Abziehen von Hand. 9. Schneiden Sie die Blindader ab. 11. Fuhren Sie die Adern bis zum Anschlag in die Kontaktierelemente des FC RJ45 Plug ein 12. Schieben Sie das Kabel in Position wie im Bild dargestellt (siehe Pfeile). Drucken Sie die Kontaktierelemente bis zum Anschlag hinunter. 18 5 10. Fachern Sie die Adern gema den Farbmarkierungen auf den Kontaktierelementen des FC RJ45 Plugs auf. o 90 13. Schlieen Sie den Deckel und drehen Sie das Verschlussstuck in Pfeilrichtung soweit, wie dies von Hand moglich ist. 14. Stecken Sie einen Schraubendreher 2,5 mm durch die Bohrung im Verschlussstuck und drehen Sie bis zum Anschlag weiter. 15. Der Stecker ist korrekt verriegelt, wenn die Offnung des Verschlussstucks zur Seite gerichtet ist und die Seitenflachen plan mit dem Stecker verlaufen. 16. Entriegeln Sie den Stecker bei beengten Einbauverhaltnissen mit einen Schraubenzieher (2,5 mm Klingenbreite). Die Schneidklemm-Kontakte des FC RJ45 Plug konnen bis zu 10 Mal gelost und neu kontaktiert werden. Kontaktierte Leitungsenden durfen nicht nochmals kontaktiert werden sondern mussen abgeschnitten werden. Entriegeln Sie den Stecker nicht unter Zug. Fur die Herstellung eines Verbindungskabels mit gekreuzten Adern kombinieren Sie an einem Kabelende die Adern mit den Farbmarkierungen im Stecker nach folgendem Schema: wei mit gelb verbinden blau mit orange verbinden. Hinweise: Erneuern Sie die Messerkassette bei unsauberen Schnittergebnissen bzw. nach ca. * 1500 Arbeitsgangen bei Leitungen mit PVC Auenmantel * 150 Arbeitsgangen bei Leitungen mit PUR Auenmantel Weitere Hinweise zum Netzaufbau finden Sie im SIMATIC NET Industrial Ethernet Netzhandbuch