1. Use the green knife cassette
6GK1901-1GB01 (5.1 mm knife
clearance) in the stripping tool.
If your stripping tool was supplied with a
yellow knife cassette, the cutting depth
must be adjusted with the middle socket-
head screw after fitting the new cassette!
2. Take the stripping tool in your right hand.
3. Measure the cable length against the
measuring template. Use your left index
finger as the limit stop.
4. Insert the cable into the stripping tool.
Your left index finger is the limit stop.
5. Tighten the stripping tool fully.
6. To strip the insulation, turn the tool in the
direction of the arrow
- approx. 4 times for PVC insulation,
- approx, 8 times for PUR insulation.
7. Keeping the stripping tool closed, pull it
off the end of the cable along with the
jacket and remnants of the shield.
8. If the white filler is not removed with the
insulation, remove it and the transparent
protective foil with your hand.
9. Cut off the dummy cores.
10. Spread out the wires according to the
color markings on the contact elements
of the FC RJ45 plug.
11. Insert the wires into the contact
elements of the FC RJ45 plug as far as
the limit stop.
12. Push the cable into position as shown
in the picture (see arrows). Press down
the contact elements as far as the limit
stop to contact the wires.
13. Close the cover and turn the locking
mechanism in the direction of the arrow
as far as possible with your hand.
14. Insert a 2.5 mm screwdriver into the
hole in the locking mechanism and turn
it as far as the limit stop.
15. The connector is correctly locked when
the opening of the locking mechanism
is pointing to the side and the surfaces
are flush with the surface of the
connector.
16. If there is little space, release the
connector catch with a screwdriver (2.5
mm blade width).
Notes:
Replace the knife cassette if the cut edges
become ragged or after approx
1500 operations on cables with PVC
outer jackets·
150 operations on cables with PUR
outer jackets
The piercing contacts of the FC RJ45 plug
can be released and recontacted up to 10
times. Cable ends that have already been
pierced must not be used again but must
be cut off.
Don’t pull while unlocking the plug.
To create a crossover cable, combine the
wires in the connector at one end according
to the following scheme:
Connect white with yellow
Connect blue with orange.
You will find information on network structures in the SIMATIC NET Industrial Ethernet Networking Manual
green
5
18
90
o
SIMATIC NET
Produktinformation
Product Information
Stand / Dated / 02/2010
Montageanleitung für / Assembly Instructions for
SIMATIC NET Industrial Ethernet
FastConnect RJ45 Plug 90 6GK1901-1BB20-2A..
Nachfolgend finden Sie Informationen in deutscher Sprache. Die aktuellen Hinweise finden Sie auf folgender
Internetseite: http://support.automation.siemens.com "Produktsupport".
You will find information below in English. You will find the latest information on the following Internet page:
http://support.automation.siemens.com "Product Support".
A5E00328643
A
5E00328643
© SIEMENS AG 2010
Änderungen vorbehalten
Subject to change
Wir haben den Inhalt der Druckschrift auf Über-
einstimmung mit dem
beschriebenen Werkzeug geprüft. Dennoch können Abweichungen
nicht ausgeschlossen werden, so daß wir für die vollständige
Übereinstimmung keine Gewähr übernehmen. Die Angaben in der
Druckschrift werden jedoch regelmäßig überprüft. Notwendige
Korrekturen sind in den nachfolgenden Auflagen enthalten. Für
Verbesserungsvorschläge sind wir dankbar.
Technische Änderungen vorbehalten.
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdrücklich
zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz.
Alle Rechte vorbehalten, insbesondere für den Fall der
Patenterteilung oder GM-Eintragung.
Copyright © Siemens AG 2010
All Rights Reserved
Wichtiger Hinweis
Wir weisen darauf hin, daß der Inhalt dieser Betriebsanleitung nicht Teil einer früheren oder bestehenden Vereinbarung, Zusage oder eines
Rechtsverhältnisses ist oder diese abändern soll. Sämtliche Verpflichtungen von Siemens ergeben sich aus dem jeweiligen Kaufvertrag, der
auch die vollständige und allein gültige Gewährleistungsregel enthält. Diese vertraglichen Gewährleistungsbestimmungen werden durch die
Ausführungen dieser Betriebsanleitung weder erweitert noch beschränkt.
Wir weisen außerdem darauf hin, daß aus Gründen der Übersichtlichkeit in dieser Betriebsanleitung nicht jede nur erdenkliche
Problemstellung im Zusammenhang mit dem Einsatz dieses Werkzeugs beschrieben werden kann. Sollten Sie weitere Informationen
benötigen oder sollten besondere Probleme auftreten, die in der Betriebsanleitung nicht ausführlich genug behandelt werden, können Sie
die erforderliche Auskunft über die örtliche Siemens-Niederlassung anfordern.
WARNUNG !
Das in der Anleitung beschriebene Werkzeug ist nur für das Abisolieren der SIMATIC NET Industrial
Ethernet FastConnect Leitungen bestimmt. Bei anderweitiger Verwendung kann es zu Unfällen oder zur
Zerstörung von Werkzeug und Leitung kommen.
Das Werkzeug darf auf keinen Fall an Leitungen die unter Spannung stehen benutzt werden.
Weitere Informationen zum Netzaufbau finden Sie im SIMATIC NET Industrial Ethernet Netzhandbuch
Anforderung an die Qualifikation des Personals
Qualifiziertes Personal im Sinne dieser Betriebsanleitung bzw. der Warnhinweise sind Personen, die mit Aufstellung,
Montage, Inbetriebsetzung und Betrieb dieses Produktes vertraut sind und über die ihrer Tätigkeit entsprechenden
Qualifikation verfügen und in erster Hilfe geschult sind.
_________________________________________________________________________________
tool described. Since deviations cannot be precluded entirely, we
cannot guarantee full agreement. However, the data in this manual
are reviewed regularly and any necessary corrections included in
subsequent editions.Suggestions for improvement are welcome.
Technical data subject to change.
The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility or design, are reserved.
Copyright © Siemens AG 2010
All Rights Reserved
Note
We would point out that the contents of this product documentation shall not become a part of or modify any prior or existing agreement,
commitment or legal relationship. The Purchase Agreement contains the complete and exclusive obligations of Siemens. Any statements
contained in this documentation do not create new warranties or restrict the existing warranty.
We would further point out that, for reasons of clarity, these operating instructions cannot deal with every possible problem arising from the
use of this device. Should you require further information or if any special problems arise which are not sufficiently dealt with in the operating
instructions, please contact your local Siemens representative.
WARNING !
The tool and plug-in connector described in the manual must only be used in conjunction with SIMATIC
NET Industrial Ethernet FastConnect cables. If used elsewhere, accidents may occur or tools, connector
and cable may be irreparably damaged.
The tool and plug-in connector must not be used on live cables under any circumstances.
CL/CSA-Rating The units are intended for communication circuits operating at 175 mA or less
and a maximum 56.5 V dc, ringing voltage not to exceed 150 Vrms or for data circuits operating
at 30 V ac, 42 V dc, 100 mA.
For more detailed information on setting up networks, refer to the SIMATIC NET Industrial Ethernet
Network Manual
Personnel qualification requirements
Qualified personnel as referred to in the operating instructions or in the warning notes are defined as persons
who are familiar with the installation, assembly, startup and operation of this product and who possess the
relevant qualifications for their work and have a First Aid qualification.
1. Verwenden Sie im Abisolierwerkzeug die
grüne Messerkassette 6GK1901-1GB01
(5,1 mm Messerabstand)!
Bei Abisolierwerkzeugen, die mit gelber
Messerkassette ausgeliefert wurden, ist
nach dem Austausch der Messerkassette
mit der mittleren Imbusschraube die
Schnitttiefe zu justieren!
2. Nehmen Sie das Abisolierwerkzeug in
die rechte Hand.
3. Messen Sie die Leitungslänge durch
Anlegen der Leitung an die
Maßschablone ab.
Benutzen Sie den Zeigefinger der linken
Hand als Anschlag.
4. Legen Sie die Leitung in das
Abisolierwerkzeug ein. Der Zeigefinger
der linken Hand bildet den Anschlag.
5. Spannen Sie das Abisolierwerkzeug bis
zum Anschlag.
6. Drehen Sie das Abisolierwerkzeug zum
Abisolieren der Leitung bei
-PVC-Isolierung ca. 4 mal, bei
-PUR-Isolierung ca. 8 mal
in Pfeilrichtung.
7. Ziehen Sie das Abisolierwerkzeug im
geschlossenen Zustand mit den Mantel-
und Schirmresten vom Leitungsende ab.
8. Falls beim Abisolieren die weiße
Füllmasse nicht mit abgezogen wurde,
entfernen Sie diese ebenso wie die
transparente Schutzfolie durch Abziehen
von Hand.
9. Schneiden Sie die Blindader ab.
10. Fächern Sie die Adern gemäß den
Farbmarkierungen auf den Kontaktier-
elementen des FC RJ45 Plugs auf.
11. Führen Sie die Adern bis zum Anschlag
in die Kontaktierelemente des FC RJ45
Plug ein
12. Schieben Sie das Kabel in Position wie
im Bild dargestellt (siehe Pfeile).
Drücken Sie die Kontaktierelemente bis
zum Anschlag hinunter.
13. Schließen Sie den Deckel und drehen
Sie das Verschlussstück in
Pfeilrichtung soweit, wie dies von Hand
möglich ist.
14. Stecken Sie einen Schraubendreher
2,5 mm durch die Bohrung im
Verschlussstück und drehen Sie bis
zum Anschlag weiter.
15. Der Stecker ist korrekt verriegelt, wenn
die Öffnung des Verschlussstücks zur
Seite gerichtet ist und die Seitenflächen
plan mit dem Stecker verlaufen.
16. Entriegeln Sie den Stecker bei
beengten Einbauverhältnissen mit
einen Schraubenzieher (2,5 mm
Klingenbreite).
Hinweise:
Erneuern Sie die Messerkassette bei
unsauberen Schnittergebnissen bzw. nach
ca.
1500 Arbeitsgängen bei Leitungen mit
PVC Außenmantel
150 Arbeitsgängen bei Leitungen mit
PUR Außenmantel
Die Schneidklemm-Kontakte des FC RJ45
Plug können bis zu 10 Mal gelöst und neu
kontaktiert werden.
Kontaktierte Leitungsenden dürfen nicht
nochmals kontaktiert werden sondern
müssen abgeschnitten werden.
Entriegeln Sie den Stecker nicht unter Zug.
Für die Herstellung eines Verbindungs-
kabels mit gekreuzten Adern kombinieren
Sie an einem Kabelende die Adern mit den
Farbmarkierungen im Stecker nach
folgendem Schema:
weiß mit gelb verbinden
blau mit orange verbinden.
Weitere Hinweise zum Netzaufbau finden Sie im SIMATIC NET Industrial Ethernet Netzhandbuch
5
18
grün
90
o