https://www.phoenixcontact.com/us/products/2839415
08/06/2014Page1/4
Surge protection base element-PT 4+F-BE-2839415
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Base element for protective plug PT with protective circuit for a 4-wire floating signal circuit, gas-filled surge
arrester between the connections 3-4 (GND) and 9-10, for mounting on NS 35/7.5 and NS35/15, housing width:
17.5 mm
The illustration shows version PT 4-
BE
Product Features
Plugs can be checked with CHECKMASTER
Maximum ease of maintenance thanks to the two-piece design
Base element remains an integral part of the installation
Consistent plug-in signal circuit protection
Impedance-neutral disconnection of plug for test and maintenance purposes
Key commercial data
Packing unit 1 pc
Weight per Piece (excluding packing) 56.37 GRM
Custom tariff number 85363010
Country of origin Germany
Technical data
Dimensions
Height 90 mm
Width 17.7 mm
Depth 65.5 mm
Horizontal pitch 1 Div.
Complete module height 90 mm
Complete module width 17.7 mm
Complete module depth 65.5 mm
Ambient conditions
https://www.phoenixcontact.com/us/products/2839415
08/06/2014Page2/4
Surge protection base element-PT 4+F-BE-2839415
Technical data
Ambient conditions
Ambient temperature (operation) -40 °C ... 85 °C
Degree of protection IP20
General
Inflammability class according to UL 94 V0
Color black
Mounting type DIN rail: 35 mm
Type DIN rail module, two-section, divisible
Direction of action Signal Ground/Shield-Earth Ground
Protective circuit
Output voltage limitation at 1 kV/µs (Core-Earth) spike ≤ 600 V
Surge protection fault message None
Connection data
Connection method Screw connection
Connection type IN Screw terminal blocks
Connection type OUT Screw terminal blocks
Screw thread M3
Tightening torque 0.5 Nm
Stripping length 8 mm
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 12
Classifications
eCl@ss
eCl@ss 4.0 27140201
eCl@ss 4.1 27130801
eCl@ss 5.0 27130801
eCl@ss 5.1 27130801
eCl@ss 6.0 27130803
eCl@ss 7.0 27130803
eCl@ss 8.0 27130803
https://www.phoenixcontact.com/us/products/2839415
08/06/2014Page3/4
Surge protection base element-PT 4+F-BE-2839415
Classifications
ETIM
ETIM 2.0 EC000472
ETIM 3.0 EC000472
ETIM 4.0 EC000472
ETIM 5.0 EC000472
UNSPSC
UNSPSC 6.01 30212010
UNSPSC 7.0901 39121610
UNSPSC 11 39121610
UNSPSC 12.01 39121610
UNSPSC 13.2 39121620
Approvals
Approvals
Approvals
UL Listed / GOST / GL
Ex Approvals
UL Listed / cUL Listed / ATEX / cULus Listed
Approvals submitted
Approval details
UL Listed
GOST
GL
https://www.phoenixcontact.com/us/products/2839415
08/06/2014Page4/4
Surge protection base element-PT 4+F-BE-2839415
Drawings
Dimensioned drawing
44,8
90
51,5
65,5
The figure shows the complete module consisting of a base element and connector
Phoenix Contact 2014 © - all rights reserved