FUSES / SICHERUNGEN PFLT
Resettable fuses
www.schurter.com
35
Type / Typ Umax Imax Ihold Itrip Initial 1 Hour (R1) Post- Max. Time Tripped Power
Resistance / Trip Resistance / to trip at 23 °C / Dissipation
Amperes / Ohms at 23 °C / Ohms at 23 °C / Amps / Seconds / Watts at 23 °C
Ampere at 23 °C
VAHold Trip min. max. R1 max. max. nom.
PFLT.100.S 24 100 1.0 2.5 0.070 0.130 0.260 5 7.0 1.5
PFLT.180 24 100 1.8 3.8 0.040 0.068 0.120 9 2.9 2.0
PFLT.180.S 24 100 1.8 3.8 0.040 0.068 0.120 9 2.9 2.0
PFLT.190 24 100 1.9 4.2 0.030 0.057 0.100 10 3.0 1.9
PFLT.260 24 100 2.6 5.2 0.025 0.042 0.076 13 5.0 2.3
PFLT.300 24 100 3.0 6.3 0.015 0.031 0.055 15 4.0 2.0
PFLT.340 24 100 3.4 6.8 0.016 0.027 0.050 17 5.0 2.7
Type / Typ
Ambient Operating Temperature
–40 ˚C –20 ˚C 0 ˚C 23 ˚C 40 ˚C 50 ˚C 60 ˚C 70 ˚C 85 ˚C
PFLT.100.S 1.8 1.6 1.4 1.0 0.8 0.7 0.6 0.4 0.2
PFLT.180 3.1 2.6 2.2 1.8 1.3 1.1 0.9 0.6 0.2
PFLT.180.S 3.1 2.6 2.2 1.8 1.3 1.1 0.9 0.6 0.2
PFLT.190 3.3 2.8 2.4 1.9 1.4 1.2 1.1 0.7 0.4
PFLT.260 4.3 3.7 3.1 2.6 1.9 1.6 1.4 1.1 0.6
PFLT.300 5.1 4.4 3.7 3.0 2.3 1.9 1.6 1.2 0.6
PFLT.340 5.5 4.7 4.0 3.4 2.6 2.2 1.9 1.5 0.8
How To Order
PF LT . xxx . x
PTC-Fuse
Style
LT = Low temperature axial leaded
“strap” component
Hold Current, Ihold
100-340 (1.00 A - 3.40 A)
Slotted lead option
Thermal Derating Chart - Ihold
(Amps)
Packaging
All models packaged in bulk, 500 pieces each.
Packaged loose; optional slotted leads (.S) available for 1 A and 1.8 A ratings
Type / Typ A B C D F
Package style
min. max. min. max. min. max. min. max. min. max.
PFLT.100S 20.9 23.1 4.9 5.2 0.6 1.0 4.1 5.5 3.9 4.1 S
PFLT.180 24.0 26.0 4.9 5.2 0.6 1.0 4.1 5.5 3.9 4.1 Std.
PFLT.180S 24.0 26.0 4.9 5.2 0.6 1.0 4.1 5.5 3.9 4.1 S
PFLT.190 21.3 23.4 10.2 11.0 0.5 1.1 5.0 7.6 4.8 5.4 Std.
PFLT.260 24.0 26.0 10.8 11.9 0.6 1.0 5.0 7.0 5.9 6.1 Std.
PFLT.300 28.4 31.8 13.0 13.5 0.5 1.1 6.3 8.9 6.0 6.6 Std.
PFLT.340 24.0 26.0 14.8 15.9 0.6 1.0 4.0 5.0 5.9 6.1 Std.
Dimensions
Dimensions = mm