General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
1
Two-circuit Limit Switches
WL-N/WL
Two-circuit limit switches that can be
selected to match the operating
environment and application
•Wide variety of head shapes, including Roller Lever,
Plunger, Flexible Rod, and Fork Lock Lever Switches
(General-purpose Switches).
•You can select the optimum actuator shape for the
workpiece shape and movement from a variety of
actuators.
In addition to general detection, we also have environment
resistant models for harsh environments, sputter
resistantmodels for welding processes, and long-life
models for high-frequency use.
Degree of Protection; IP67
Two-circuit Limit Switch
WL-N/WL General-purpose Switches .............................................................................................................. page 5
WL-N/WL Environment-resistant Switches ...................................................................................................... page 33
WL-N/WL Spatter-prevention Switches............................................................................................................ page 53
WL-N/WL Long-life Switches ........................................................................................................................... page 64
Common Features
Common Specifications ................................................................................................................................... page 75
Common Accessories (Sold Separately) ......................................................................................................... page 76
Safety Precautions........................................................................................................................................... page 81
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on pages 81 to 86 and
Safety Precautions for All Limit Switches.
WL-N/WL
2
Model Number Structure
List of Models
Roller lever
Note: indicates features included in the ordered model.
*1. The operating environment temperature is -10°C to +80°C, and the protection rating is IP67.
*2. Models with airtight built-in switch specifications suitable for use in water drop or mist atmospheres are also available.
Actuator
R38 R50 R63
Adjustable
Roller Lever
(R25 to
89 mm)
Page
Type of
Switches Operating environment Indicator
Wiring
Specifications
General-
purpose
Switches *1
Without operation indicator Screw
terminals
*2 ❍❍
*2
page 5
With operation
indicator
LED *2 ❍❍
*2
Neon lamp *2 ❍❍
*2
With operation
indicator LED Direct-wire
connector *2 --- --- ---
With operation
indicator LED Pre-wired
Connector *2 --- --- ---
Environment-
resistant
Switches
Ambient operating
temperature (5 to 120°C)
Without operation
indicator
Screw
terminals
--- ---
page 33
Ambient operating
temperature (-40 to 40°C) --- ---
Chemicals and oil --- ---
Outdoors --- ---
Coolant drops and mist
Direct-wire
cable
--- ---
Mist (Improved sealing for
conduit opening and cover) --- ---
Constant water drops and
mist (Molded conduit
opening and cover.)
--- ---
Constant water drops or
splattering cutting powder
(Preventing intrusion of
cutting powder through
molded conduit opening,
cover, and head seal, and a
head cap)
--- ---
Spatter-
prevention
Switches
Spattering from welding With operation
indicator
LED Screw
terminals
--- --- ---
page 53
Neon lamp --- --- ---
LED Pre-wired
connectors --- --- ---
Long-life
Switches High-durability With operation
indicator
LED Screw
terminals --- --- ---
page 64
LED Pre-wired
connectors --- --- ---
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
3
Plunger Actuators
Note: indicates features included in the ordered model.
*1. The standard wiring specifications are screw terminals types. The operating environment temperature is -10°C to +80°C, and the protection
rating is IP67.
*2. Models with airtight built-in switch specifications suitable for use in water drop or mist atmospheres are also available.
Actuator Sealed
top-roller
plunger
Top-roller
plunger
Sealed
top
plunger
Sealed
top-ball
plunger Page
Type Operating environment Indicator Wiring
Specifications
General-
purpose
Switches *1
Without operation
indicator Screw
terminals
*2 *2 ❍❍
page 5
With operation
indicator
LED *2 ❍❍❍
Neon
lamp *2 ❍❍❍
With operation
indicator LED Direct-wire
connector *2 --- --- ---
With operation
indicator LED Pre-wired
connectors *2 --- --- ---
Environment-
resistant
Switches
Ambient operating
temperature (5 to 120°C)
Without operation
indicator
Screw
terminals
❍❍--- ---
page 33
Ambient operating
temperature (-40 to 40°C) --- --- ---
Chemicals and oil --- --- ---
Outdoors --- --- --- ---
Coolant drops and mist
Direct-wire
cable
--- --- ---
Mist (Improved sealing for
conduit opening and cover)
❍❍--- ---
Constant water drops or
splattering cutting powder
(Preventing intrusion of
cutting powder through
molded conduit opening,
cover, and head seal, and
a head cap)
❍❍--- ---
Spatter-
prevention
Switches
Spattering from welding With operation
indicator
LED Screw
terminals
--- --- ---
page 53
Neon
lamp --- --- ---
LED Pre-wired
connectors --- --- ---
Actuator Horizontal
plunger
Horizontal-roller
plunger
Horizontal-ball
plunger Page
Type Operating environment Indicator Wiring
Specifications
General-
purpose
Switches *1
Without operation
indicator Screw
terminals
*2 *2
page 5
With operation
indicator
LED ❍❍❍
Neon
lamp ❍❍❍
With operation
indicator LED Direct-wire
connector --- --- ---
With operation
indicator LED Pre-wired
connectors --- --- ---
Environment-
resistant
Switches
Ambient operating
temperature (5 to 120°C)
Without operation
indicator
Screw
terminals
❍❍---
page 33
Ambient operating
temperature (-40 to 40°C) ❍❍---
Chemicals and oil ❍❍---
Outdoors --- --- ---
Coolant drops and mist
Direct-wire
cable
❍❍---
Mist (Improved sealing for
conduit opening and cover)
--- ---
Constant water drops or
splattering cutting powder
(Preventing intrusion of
cutting powder through
molded conduit opening,
cover, and head seal, and
a head cap)
❍❍---
Spatter-
prevention
Switches
Spattering from welding With operation
indicator
LED Screw
terminals
--- --- ---
page 53
Neon
lamp --- --- ---
LED Pre-wired
connectors --- --- ---
WL-N/WL
4
Flexible Rod Actuators
Note: indicates features included in the ordered model.
*1. The standard wiring specifications are screw terminals types. The operating environment temperature is -10°C to +80°C, and the protection rating is IP67.
*2. Models with airtight built-in switch specifications suitable for use in water drop or mist atmospheres are also available.
Fork Lock Lever Actuators
Note: indicates features included in the ordered model.
* The standard wiring specifications are screw terminals types. The operating environment temperature is -10°C to +80°C, and the protection rating is IP67.
Actuator Adjustable
rod lever
(25 to
140 mm)
Adjustable rod
lever (350 to
380 mm)
Rod spring
lever Page
Type Operating environment Indicator
Wiring
Specifications
General-
purpose
Switches
*1
Without operation
indicator
Screw
terminals
*2 ❍❍
page 5
With
operation
indicator
LED --- ---
Neon
lamp --- --- ---
With
operation
indicator
LED Direct-wire
connector ❍❍❍
With
operation
indicator
LED Pre-wired
connectors ❍❍❍
Environment-
resistant
Switches
Ambient operating
temperature (5 to 120°C)
Without operation
indicator
Screw
terminals
--- ---
page 33
Ambient operating
temperature (-40 to 40°C) --- ---
Chemicals and oil --- ---
Outdoors --- ---
Coolant drops and mist
Direct-wire
cable
--- ---
Mist (Improved sealing for
conduit opening and cover)
--- ---
Constant water drops and
mist (Molded conduit
opening and cover.)
--- ---
Actuator
Coil spring
(6.5 dia.)
Coil spring
(4.8 dia.)
Resin rod
(8 dia.) Steel wire
(1 dia.) Page
Type Operating environment Indicator
Wiring
Specifications
General-
purpose
Switches
*1
Without operation
indicator
Screw
terminals
*2 ❍❍ *2
page 5
With
operation
indicator
LED *2 ❍❍ *2
Neon
lamp *2 ❍❍ *2
With
operation
indicator
LED Direct-wire
connector --- --- --- ---
With
operation
indicator
LED Pre-wired
Connector --- --- --- ---
Environment-
resistant
Switches
Ambient operating
temperature (5 to 120°C)
Without operation
indicator
Screw
terminals
--- --- ---
page 33
Ambient operating
temperature (-40 to 40°C) --- --- ---
Chemicals and oil --- --- ---
Outdoors --- --- ---
Coolant drops and mist
Direct-wire
cable
--- ---
Mist (Improved sealing for
conduit opening and cover)
--- ---
Constant water drops and
mist (Molded conduit
opening and cover.)
--- ---
Actuator Fork Lock
Lever (1)
Fork Lock
Lever (2)
Fork Lock
Lever (3)
Fork Lock
Lever (4) Page
Type Operating environment Indicator
Wiring
Specifications
General-
purpose
Switches
*1
Without operation
indicator
Screw
terminals
❍❍❍❍
page 5
With
operation
indicator
LED --- ---
Neon
lamp ❍❍❍---
With
operation
indicator
LED Direct-wire
connector --- --- --- ---
With
operation
indicator
LED Pre-wired
connectors --- --- --- ---
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
5
General-purpose Switches
WL-N/WL
Wide variety of head shapes to match
the operating environment and
application
•Wide variety of head shapes, including Roller Lever,
Plunger, Flexible Rod, and Fork Lock Lever Switches.
Wide variety of head shapes for fork lock lever
•You can select the optimum actuator shape for the
workpiece shape and movement from a variety of
actuators. Enables selection of optimum shape
Degree of Protection; IP67
Operation indicators (LED/neon lamps) for enabling simple
daily inspection are available
In addition to regular screw terminals, direct-wire and
pre-wired connectors are also available based on the
wiring specifications
Features
For the most recent information on models that have been certified for
safety standards, refer to the OMRON website.
Be sure to read Safety Precautions on pages 81 to 86 and
Safety Precautions for All Limit Switches.
Indicates the operation status of the switches using LEDs and neon lamps.
Selectable based on wiring specifications
Screw terminals
Pre-wired connector
A type with operation indicators for easily confirming operation is available
The light-ON when operating status and the light-ON when not operating
status can be easily switched by turning the lamp holder 180°.
Light-ON when Operating Light-ON when Not Operating
Pre-wired connectors include Smartclick products that turn by only
1/8-turn when attaching and removing
This reduces the labor required for connections and maintenance.
Indicator down
Indicator up
Direct-wire
connector
WL-N/WL
6
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Basic models
(1) Actuator and Property Specifications
* The lever attachment method varies in (1) to (4).
(2) Built-in Switch Specifications
*(1) Actuator and Property Specifications: Roller levers (R38 mm)
and sealed top-roller plungers only
(3) Indicator Specifications
*(1) Actuator: Excluding the symbols CA32-42 and CA32-44
(4) Wiring Specifications
*1. (1) Actuator and Property Specifications: Roller levers (R38 mm)
only
*2. (1) Actuator and Property Specifications: Roller levers (R38 mm)
and sealed top-roller plungers only
WL@-@@@-N
(1) (2) (3) (4)
Code Actuator Pretravel
(PT)
CA2
Roller Lever
Roller lever: R38 mm
15±5°
CA2-2 25±5°
CA2-2N 20° max.
CA2-7 Roller lever: R50 mm 15±5°
CA2-8 Roller lever: R63 mm 15±5°
CA12 Adjustable roller lever
(R25 to 89 mm)
15±5°
CA12-2 25±5°
CA12-2N 20° max.
D28
Plunger Actuators
Sealed top-roller plunger
1.7 mm max.
D2 Top-roller plunger
1.7 mm max.
D18 Sealed top plunger
1.7 mm max.
D38 Sealed top-ball plunger
1.7 mm max.
SD Horizontal plunger
2.8 mm max.
SD2 Horizontal-roller plunger
2.8 mm max.
SD3 Horizontal-ball plunger
2.8 mm max.
CL
Flexible Rod
Actuators
Adjustable Rod Lever
(25 to 140 mm)
15±5°
CL-2 25±5°
CL-2N 20° max.
CAL4 Adjustable Rod Lever
(350 to 380 mm) 15±5°
CAL5 Rod spring lever 15±5°
NJ Coil spring
(6.5 dia.) 20±10 mm
NJ-30 Coil spring
(4.8 dia.) 20±10 mm
NJ-2 Flexible rod:
Resin rod (8 dia.) 40±20 mm
NJ-S2 Flexible rod:
Steel wire (1 dia.) 40±20 mm
CA32-41
Fork Lock Lever *
(1) 55° max.
CA32-42 (2) 55° max.
CA32-43 (3) 55° max.
CA32-44 (4) 55° max.
(1) (2) (3) (4)
Code Specifications
None Standard
55 Airtight built-in switch *
Code Specifications
None No indicator
LD LED (10 to 115 VAC/DC)
LE Neon lamp (125 to 250 VAC) *
Code Terminal shape
Connector
shape
Voltage
Wiring
locations
Connector
pin No.
None Screw terminals
(Conduit size: G½) --- --- --- ---
K13A
Direct-wire
connector type *1
*2
Threaded
(M12)
AC NO only NO:
K13 DC NO only NO:
K43A AC NC+NO NO:
NC:
K43 DC NC+NO NO:
NC:
-M1J
Pre-wired
connector *2
Threaded
(M12)
DC
NO only NO:
-M1GJ NO only
NO:
-M1JB NC only NC:
-DGJ NC+NO NO:
NC:
-DK1EJ NO only NO:
NC:
-DTGJ Pre-wired
connector *1
Smartclick
DC
NC+NO NO:
NC:
-DTK1EJ NO only NO:
NC:
3 4
3 4
3 4
1 2
3 4
1 2
3 4
1 4
3 4
1 2
3 4
2
3 4
1 2
3 4
2
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
7
High-sensitivity and High-precision Models
(1) Actuator and Property Specifications
(2) Built-in Switch Specifications
(3) Indicator Specifications
*1. (1) Actuator and Property Specifications Symbol:12, L
(4) Wiring Specifications: Screw terminals only
*2. (1) Actuator: Symbol 2
(4) Wiring Specifications: Direct-wire connector and pre-wired
connector models only
(4) Wiring Specifications
*(1) Actuator: Roller levers (R38 mm) only
WLG@-@@@
(1) (2) (3) (4)
Code Actuator Pretravel
(PT)
2Roller lever Roller lever: R38 mm
High-sensitivity Models 10°
CA2 Roller lever Roller lever: R38 mm
High-precision Models
12 Roller lever
Adjustable roller lever
(R25 to 89 mm)
High-sensitivity Models
10°
LFlexible rod
Adjustable Rod Lever
(25 to 140 mm)
High-sensitivity Models
10°
Code Specifications
None Standard built-in switch
55 Airtight built-in switch
Code Specifications
None No indicator
LE Neon lamp (125 to 250 VAC) *1
LD LED (10 to 115 VAC/DC) *2
+2°
-1°
+2°
+2°
-1°
+2°
-1°
Code Terminal shape
Connector
shape
Voltage
Wiring
locations
Connector
pin No.
None Screw terminals
(Conduit size: G½) --- --- --- ---
K13 Direct-wire
connector type *
Threaded
(M12)
DC
NO only NO:
K43 NC+NO NO:
NC:
-M1J
Pre-wired
connector type *
Threaded
(M12)
DC
NO only NO:
-M1GJ NO only NO:
-M1JB NC only NC:
-DGJ03 NC+NO NO:
NC:
-DK1EJ03
NC only NO:
NC:
-M1TJ
Pre-wired
connectors type *
Smartclick
DC
NO only NO:
-M1TGJ NO only NO:
-M1TJB NC only NC:
-DTGJ03 NC+NO NC:
NO:
-DTK1EJ03
NC only NC:
NO:
3 4
3 4
1 2
3 4
1 4
3 2
3 4
1 2
3 4
2
3 4
1 4
3 2
1 2
3 4
2
3 4
WL-N/WL
8
Ordering Information
Roller Lever
Standard built-in switch
Note: The photo shows a typical model.
Appearance
Actuator Terminal shape Pretravel
(PT)
Without operation
indicator
With operation indicator
LED Neon lamp
Model Model Model
Roller lever: R38 mm
Screw terminals
(Conduit size: G½)
15±5° WLCA2-N WLCA2-LD-N WLCA2-LE-N
25±5° WLCA2-2-N WLCA2-2LD-N WLCA2-2LE-N
20° max. WLCA2-2N-N WLCA2-2NLD-N WLCA2-2NLE-N
10° WLG2 WLG2-LD WLG2-LE
WLGCA2 WLGCA2-LD WLGCA2-LE
Roller lever: R50 mm
15±5° WLCA2-7-N WLCA2-7LD-N WLCA2-7LE-N
25±5° --- --- ---
20° max. --- --- ---
Roller lever: R63 mm
15±5° WLCA2-8-N WLCA2-8LD-N WLCA2-8LE-N
25±5° --- --- ---
20° max. --- --- ---
Adjustable roller lever
(R25 to 89 mm)
15±5° WLCA12-N WLCA12-LD-N WLCA12-LE-N
25±5° WLCA12-2-N WLCA12-2LD-N WLCA12-2LE-N
20° max. WLCA12-2N-N WLCA12-2NLD-N WLCA12-2NLE-N
10° WLG12 WLG12-LD WLG12-LE
Appearance
Actuator Terminal shape Pretravel
(PT)
Connector
shape Voltage Wiring
locations
Connector
pin No. Model
Roller lever: R38 mm Direct-wire
connector
15±5°
Threaded
(M12)
AC NO only NO: WLCA2-LDK13A-N
DC NO only NO: WLCA2-LDK13-N
AC NC+NO NO:
NC: WLCA2-LDK43A-N
DC
NC+NO NO:
NC: WLCA2-LDK43-N
10°
NO only NO: WLG2-LDK13
NC+NO NO:
NC: WLG2-LDK43
NO only NO: WLGCA2-LDK13
NC+NO NO:
NC: WLGCA2-LDK43
Roller lever: R38 mm Pre-wired
connectors
15±5°
Threaded
(M12)
DC
NO only NO: WLCA2-LD-M1J-N
NO only NO: WLCA2-LD-M1GJ-N
NC+NO NO:
NC: WLCA2-LD-DGJ-N
NO only NO:
NC: WLCA2-LD-DK1EJ-N
NO only NO:
NC: WLCA2-LD-DK1EJ-N
Smartclick
NC+NO NO:
NC: WLCA2-LD-DTGJ-N
NO only NO:
NC: WLCA2-LD-DTK1EJ-N
10°
Threaded
(M12)
NO only NO: WLG2-LD-M1J
NO only NO: WLG2-LD-M1GJ
NC only NC: WLG2-LD-M1JB
NC+NO NO:
NC: WLG2-LD-DGJ03
NC only NO:
NC: WLG2-LD-DK1EJ03
NO only NO: WLG2-LD-M1TJ
NO only NO: WLG2-LD-M1TGJ
NC only NC: WLG2-LD-M1TJB
NC+NO NO:
NC: WLG2-LD-DTGJ03
NC only NO:
NC: WLG2-LD-DTK1EJ03
+2°
-1°
+2°
+2°
-1°
3 4
3 4
3 4
1 2
3 4
1 2
+2°
-1°
3 4
3 4
1 2
+2°
3 4
3 4
1 2
3 4
3 4
3 4
1 2
3 4
2
3 4
2
3 4
1 2
3 4
2
+2°
-1°
3 4
1 4
3 2
3 4
1 2
3 4
2
+2°
3 4
1 4
3 2
3 4
1 2
3 4
2
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
9
Airtight Built-in Switch
Note: The photo shows a typical model.
Appearance
Actuator Terminal shape Pretravel
(PT)
Without operation
indicator
With operation indicator
LED Neon lamp
Model Model Model
Roller lever: R38 mm Screw terminals
(Conduit size: G½)
15±5° WLCA2-55-N WLCA2-55LD-N WLCA2-55LE-N
25±5° WLCA2-255-N WLCA2-255LD-N WLCA2-255LE-N
20° max. WLCA2-2N55-N WLCA2-2N55LD-N WLCA2-2N55LE-N
10° WLG2-55 WLG2-55LD WLG2-55LE
WLGCA2-55 WLGCA2-55LD WLGCA2-55LE
Adjustable roller lever
(R25 to 89 mm)
Screw terminals
(Conduit size: G½)
15±5° WLCA12-55-N WLCA12-55LD-N WLCA12-55LE-N
25±5° --- --- ---
20° max. --- --- ---
10° --- --- ---
Appearance
Actuator Terminal
shape
Pretravel
(PT)
Connector
shape Voltage Wiring
locations Connector pin No. Model
Roller lever:
R38 mm
Direct-wire
connector
15±5°
Threaded (M12) DC
NO only NO: WLCA2-55LDK13-N
NC+NO NO: NC: WLCA2-55LDK43-N
10° NO only NO: WLG2-55LDK13
NC+NO NO: NC: WLG2-55LDK43
NO only NO: WLGCA2-55LDK13
NC+NO NO: NC: WLGCA2-55LDK43
Roller lever:
R38 mm
Pre-wired
connectors
15±5° Threaded (M12) DC
NO only NO: WLCA2-55LD-M1J-N
NO only NO: WLCA2-55LD-M1GJ-N
NC only NC: WLCA2-55LD-M1JB-N
NC+NO NO: NC: WLCA2-55LD-DGJ-N
Smartclick DC NC+NO NO: NC: WLCA2-55LD-DTGJ-N
10°
Threaded (M12)
DC
NO only NO: WLD2-55LD-M1J
NO only NO: WLG2-55LD-M1GJ
NC only NC: WLG2-55LD-M1JB
NC+NO NO: NC: WLG2-55LD-DGJ03
NC only NO: NC: WLG2-55LD-DK1EJ03
Smartclick
NO only NO: WLG2-55LD-M1TJ
NO only NO: WLG2-55LD-M1TGJ
NC only NC: WLG2-55LD-M1TJB
NC+NO NO: NC: WLG2-55LD-DTGJ03
NC only NO: NC: WLG2-55LD-DTK1EJ03
+2°
-1°
+2°
+2°
-1°
3 4
3 4
1 2
+2°
-1°
3 4
3 4
1 2
+2°
3 4
3 4
1 2
3 4
1 4
3 2
3 4
1 2
3 4
1 2
+2°
-1°
3 4
1 4
3 2
3 4
1 2
3 4
2
3 4
1 4
3 2
3 4
1 2
3 4
2
WL-N/WL
10
Plunger Actuators
Standard built-in switch
Airtight Built-in Switch
Appearance
Actuator Terminal shape Pretravel
(PT)
Without operation
indicator
With operation indicator
LED Neon lamp
Model Model Model
Sealed top-roller plunger
Screw terminals
(Conduit size: G½)
1.7 mm max.
WLD28-N WLD28-LD-N WLD28-LE-N
Top-roller plunger WLD2-N WLD2-LD-N WLD2-LE-N
Sealed top plunger WLD18-N WLD18-LD-N WLD18-LE-N
Sealed top-ball plunger WLD38-N WLD38-LD-N WLD38-LE-N
Horizontal plunger
2.8 mm max.
WLSD-N WLSD-LD-N WLSD-LE-N
Horizontal-roller plunger WLSD2-N WLSD2-LD-N WLSD2-LE-N
Horizontal-ball plunger WLSD3-N WLSD3-LD-N WLSD3-LE-N
Appearance
Actuator Terminal
shape
Pretravel
(PT) Connector shape Voltage Wiring
locations Connector pin No. Model
Sealed top-roller
plunger
Direct-wire
connector
type
1.7 mm max.
Threaded (M12) DC
NO only NO: WLD28-LDK13-N
NC+NO NO: NC: WLD28-LDK43-N
Pre-wired
connector
type
NO only NO: WLD28-LD-M1J-N
NO only NO: WLD28-LD-M1GJ-N
NC+NO NO: NC: WLD28-LD-DGJ-N
NO only NO: NC: WLD28-LD-DK1EJ-N
Appearance
Actuator Terminal shape Pretravel
(PT)
Without operation
indicator
With operation indicator
LED Neon lamp
Model Model Model
Sealed top-roller plunger
Screw terminals
(Conduit size: G½)
1.7 mm max.
WLD28-55-N WLD28-55LD-N WLD28-55LE-N
Top-roller plunger
1.7 mm max.
WLD2-55-N WLD2-55LD-N WLD2-55LE-N
Horizontal plunger
2.8 mm max.
WLSD-55-N WLSD-55LD-N ---
Horizontal-roller plunger
2.8 mm max.
WLSD2-55-N WLSD2-55LD-N ---
Appearance
Actuator Terminal
shape
Pretravel
(PT) Connector shape Voltage Wiring
locations Connector pin No. Model
Sealed top-roller
plunger
Direct-wire
connector
type
1.7 mm max.
Threaded (M12) DC
NO only NO: WLD28-55LDK13-N
NC+NO NO: NC: WLD28-55LDK43-N
Pre-wired
connectors
type
NO only NO: WLD28-55LD-M1J-N
NO only NO: WLD28-55LD-M1GJ-N
NC+NO NO: NC: WLD28-55LD-DGJ-N
NO only NO: NC: WLD28-55LD-DK1EJ-N
3 4
3 4
1 2
3 4
1 4
3 4
1 2
3 4
2
3 4
3 4
1 2
3 4
1 4
3 4
1 2
3 4
2
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
11
Flexible Rod
Standard built-in switch
Airtight Built-in Switch Specifications
Fork Lock Lever
Appearance
Actuator Terminal shape Pretravel
(PT)
Without operation
indicator
With operation indicator
LED Neon lamp
Model Model Model
Adjustable rod lever:
(25 to 140 mm)
Screw terminals
(Conduit size: G½)
15±5° WLCL-N WLCL-LD-N WLCL-LE-N
25±5° WLCL-2-N WLCL-2LD-N WLCL-2LE-N
20° max. WLCL-2N-N WLCL-2NLD-N WLCL-2NLE-N
10° WLGL WLGL-LD WLGL-LE
Adjustable rod lever:
(350 to 380 mm)
15±5° WLCAL4-N WLCAL4-LD-N WLCAL4-LE-N
25±5° --- --- ---
20° max. --- --- ---
Rod spring lever
15±5° WLCAL5-N WLCAL5-LD-N WLCAL5-LE-N
25±5° --- --- ---
20° max. --- --- ---
Coil spring (6.5 dia.) 20±10 mm WLNJ-N WLNJ-LD-N WLNJ-LE-N
Coil spring (4.8 dia.) 20±10 mm WLNJ-30-N WLNJ-30LD-N WLNJ-30LE-N
Flexible rod 40±20 mm WLNJ-2-N WLNJ-2LD-N WLNJ-2LE-N
Flexible rod: Steel wire
(1 dia.) 40±20 mm WLNJ-S2-N WLNJ-S2LD-N WLNJ-S2LE-N
Appearance
Actuator Terminal shape Pretravel
(PT)
Without operation
indicator
With operation indicator
LED Neon lamp
Model Model Model
Adjustable rod lever:
25 to 140 mm
Screw terminals
(Conduit size: G½)
15±5° WLCL-55-N WLCL-55LD-N ---
25±5° --- --- ---
20° max. --- --- ---
Coil spring (6.5 dia.) 20±10 mm WLNJ-55-N WLNJ-55LD-N ---
Flexible rod: Resin rod
(8 dia.) 40±20 mm WLNJ-255-N WLNJ-255LD-N ---
Appearance
Actuator Terminal shape Pretravel
(PT)
Without operation
indicator
With operation indicator
LED Neon lamp
Model Model Model
Fork Lock Lever 1
Screw terminals
(Conduit size: G½)
55° max. WLCA32-41-N WLCA32-41LD-N WLCA32-41LE-N
Fork Lock Lever 2 55° max. WLCA32-42-N --- WLCA32-42LE-N
Fork Lock Lever 3 55° max. WLCA32-43-N WLCA32-43LD-N WLCA32-43LE-N
Fork Lock Lever 4 55° max. WLCA32-44-N --- ---
+2°
-1°
WL-N/WL
12
Specifications
Ratings
Screw terminals
Without Operation Indicator
With Operation Indicator (LED)
With Operation Indicators (Neon Lamps)
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Allowable Inrush Current/Minimum Applicable Load
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC
125 10 3 1.5 5 --- 10 5 2.5 --- ---
250 10 2 1 5 --- 10 3 1.5 --- ---
500 10 1.5 0.8 --- --- 3 1.5 0.8 --- ---
DC
810 6 3 --- --- 10 6 --- ---
14 10 6 3 --- --- 10 6 --- ---
30 6 4 3 --- --- 6 4 --- ---
125 0.8 0.2 0.2 0.4 --- 0.8 0.2 --- ---
250 0.4 0.1 0.1 0.2 --- 0.4 0.1 --- ---
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 115 10 3 1.5 5 --- 10 5 2.5 --- ---
DC
12 10 6 3 --- --- 10 6 --- ---
24 6 4 3 --- --- 6 4 --- ---
48 3 2 1.5 --- --- 3 0.2 --- ---
115 0.8 0.2 0.4 --- 0.8 0.1 --- ---
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 5 --- 10 5 2.5 --- ---
250 10 2 1 5 --- 10 3 1.5 --- ---
Operating
characteristics
type
Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Inrush
current
NC 30 A max. 15 A max.
NO 20 A max. 10 A max.
Minimum appli-
cable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
13
Direct-wired connector and Pre-wired Connector Type
Connector DC Specifications: With Operation Indicators (LEDs)
Connector AC Specifications: With Operation Indicators (LEDs)
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Allowable Inrush Current/Minimum Applicable Load
Operation Indicator
Characteristics
Note: The above figures are initial values.
*1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON
sales representative for more detailed information on other operating environments.
*2. Except Switches with Flexible Rod Actuators.
*Excluding those with operation indicators.
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
DC
12 3 3 --- --- 3 3 --- ---
24 3 3 --- --- 3 3 --- ---
48 4 2 1.5 --- --- 3 2 --- ---
115 0.8 0.2 0.2 0.4 --- 0.8 0.2 --- ---
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 115 3 3 1.5 3 --- --- 3 3 2.5 --- --- ---
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WL)
Inrush current NC 3 A max.
NO 3 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
Operation indicator type LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current
(Reference value)
Approx. 0.4 mA at 10 VAC/DC
Approx. 0.5 mA at 115 VAC/DC
Approx. 0.6 mA at 125 VAC
Approx. 1.9 mA at 250 VAC
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WL)
Permissible operating
frequency
Mechanical 120 operations/minute
Electrical 30 operations/minute
Permissible operating speed 1 mm/s to 1 m/s (in case of WLCA2-N)
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-in switch)
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max. *2
Durability *1
Mechanical 15,000,000 operations min. 10,000,000 operations min.
Electrical 750,000 operations min. (3 A at 250 VAC, resistive load),
but for high-precision models:
500,000 operations min. (3 A at 115 VAC, resistive load),
but for high-precision models:
Ambient operating temperature -10 to +80°C (with no icing)
Ambient operating humidity 35 to 95%RH
Degree of protection IP67
Weight Approx. 255 g (in case of WLCA2-N) Approx. 270 g (in case of WLGCA2)
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WL)
Wiring Specifications Screw terminals Direct-wire connector/
Pre-wired Connector Models Screw terminals Direct-wire connector/
Pre-wired Connector Models
Dielectric
strength
Between terminals of the same
polarity
1,000 VAC,
50/60 Hz for 1 min *
600 VAC,
50/60 Hz for 1 min *
600 VAC,
50/60 Hz for 1 min *
600 VAC,
50/60 Hz for 1 min *
Between currentcarrying metal
part and ground
2,200 VAC,
50/60 Hz for 1 min
1,500 VAC,
50/60 Hz for 1 min
1,500 VAC,
50/60 Hz for 1 min
1,500 VAC,
50/60 Hz for 1 min
Between each terminal and
non-current-carrying metal part
2,200 VAC,
50/60 Hz for 1 min
1,500 VAC,
50/60 Hz for 1 min
1,500 VAC,
50/60 Hz for 1 min
1,500 VAC,
50/60 Hz for 1 min
WL-N/WL
14
Circuit Configuration
Terminal Connection Diagram
*Light-ON when not operating means the operation indicator is lit when the actuator is free and is not lit when the actuator rotates or is pushed
down and the Switch contacts contact to NO.
The above shows details of the switch interior. External wires (external resistances) are not shown. For details, refer to Operation on page 18.
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
Connector Pin Layout Diagram
* The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.
Operating
characteristics type Basic models (WL-N)
Wiring Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Without operation
indicator
With operation indicator
(Light-ON when not
operating *)
Operating
characteristics type High-sensitivity and High-precision models (WL)
Wiring Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Without operation
indicator
With operation indicator
(Light-ON when not
operating *)
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
NONCNCNO
4 3
4 1 2 3
NONCNCNO
43
4 1
3 2
4 1 2 3
AC DC
2 core
4 core
Za Za
2 core
4 core
1 2 3 4 indicate the connector pin number.
1 2 3 4 indicate the connector pin number.
--- --- --- ---
--- ---
--- ---
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
Internal
circuits
NONCNCNONONCNCNO
Za Za
4 3
4 1 2 3
4 3
4 1
3 2
4 1 2 3
AC DC
--- --- --- ---
--- ---
--- ---
Internal
circuits Internal
circuits
2 core
4 core 2 core
4 core
41 2 3 indicate the connector pin number.
1 2 3 4 indicate the connector pin number.
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
NONCNCNO
43
4 1 2 3
NONCNCNO
43
3
4
4
1
3 2
2
4 1 2 3
Za Za
--- --- --- ---
---
---
---
--- ---
AC DC
2 core
2 core
3 core
4 core
4 core
1 2 3 4
indicate the connector pin number.
1 2 3
indicate the connector pin number.
4
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
Internal
circuits
NONCNCNONONCNCNO
Za Za
4 3
4 1 2 3
4 3
3
4
4
1
3 2
2
4 1 2 3
AC DC
--- --- --- ---
---
---
---
--- ---
Internal
circuits Internal
circuits
2 core
2 core
3 core
4 core
4 core
1 2 3 4
indicate the connector pin number.
1 2 3 4
indicate the connector pin number.
3
4
1
2
13
2
4
AC DC
Positioning piece * Positioning piece *
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
15
Structure and Nomenclature
WLCA2-N
Built-in switch
Airtight built-in switch (-55)
Built-in switch with SPST-NO+NC
contact form
Roller Lever Bolt
Set Position Marker Plate
Set the indicator needle so that it
is between protrusions on the
bearing section on the marker
plate after operation.
Requires maintenance (excessive overtravel)
Requires maintenance (excessive overtravel)
Requires maintenance (insufficient overtravel)
Proper range
Proper range
Set position marker plate
Head
Cover Seal
High sealing performance is achieved. The seal also serves as a spacer.
There is no troublesome insulating paper, making it easy to work with the Switch.
Head-mounting Screws
Shaft Section Seal
An oil seal is fitted on the inlet of the
shaft section to maintain a tight seal.
You can change the direction of the
operational plunger to electrically switch
the direction of operation between both
sides, left only, or right only.
Operational Plunger
Head
You can remove the two screws to
mount the switch in any of the four
possible orientations.
Conduit Opening
The conduit screw is a parallel screw
for G½ piping, and is used together
with an SC connector to maintain a
tight seal.
Main unit
Terminal Screws
Four, M3.5 screws
Built-in Switch
Cover Setscrew
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Cover
Roller
Actuator
The roller is made of self-lubricating
sintered stainless steel and boasts high
resistance to wear.
Lever
The lever is forged from corrosion-resistant
aluminum alloy. It provides superior
corrosion resistance and outstanding
strength.
With roller lever, adjustable rod and flexible
rod models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
Pushbutton area
Rubber cap for sealing
Between case and cover (rear side)
Resin mold for sealing
Terminals
Integrated mold for sealing
WL-N/WL
16
WLG2
Built-in switch with SPST-NO+NC
contact form.
Bearing
The bearing smooths the plunger
movement.
Roller Lever Setscrew
Cover Setscrew
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Cover
Head
By removing the four corner screws,
the head can be mounted in any of four
orientations.
Head-mounting Screws
Terminal Screws
Four, M3.5 screws
Built-in Switch
Conduit Opening
The conduit screw is a parallel screw
for G½ piping, and is used together
with an SC connector to maintain a
tight seal.
Separator
The separator has outstanding insulation
properties and prevents the generation of
any gases which may corrode the internal
parts.
Operational Plunger
Shaft Section Seal
By fitting an O-ring to the rotary shaft
and with an appropriate interference
of the screws, high-sealing properties
are maintained.
Roller
Actuator
The roller is made of self-lubricating
sintered stainless steel and boasts high
resistance to wear.
Lever
The lever is forged from corrosion-resistant
aluminum alloy. It provides superior
corrosion resistance and outstanding
strength.
With roller lever, adjustable rod and flexible
rod models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
Set Position Marker Plate
Set the indicator needle so that it is between
protrusions on the bearing section on the
marker plate after operation.
Requires maintenance (excessive overtravel)
Requires maintenance (excessive overtravel)
Requires maintenance (insufficient overtravel)
Proper range
Proper range
Main unit
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
17
Operation Indicator
Indicator Covers
The indicator covered if outsert molded
from diecast aluminum and has outstanding
sealing properties.
Indicator Windows
Operating status (i.e., light-ON when
operating or light-ON when not operating)
depends on whether a neon lamp or an
LED is used.
Indicators can be switched from light-ON
when operating and light-ON when not
operating, by simply rotating the indicator
holder by 180°.
(However, Direct-wire connector,
Pre-wired Connector, Three-core, and
Four-core Switches cannot be switched to
light-ON when operating (NC wiring).)
Light-ON when Operating/Not Operating
Indicator
The indicator is either a neon lamp or an
LED. Switches with LED indicators have a
built-in rectifier stack, so there is no
connection polarity.
Contact Spring
The built-in switch's terminal screws
are used to connect the indicator
terminal. Since the connection spring
(coil spring) is used for this connection,
it will not be necessary to connect the
indicator terminal. When a ground
terminal is provided however, a lead
wire must be used.
Lamp Holder
Indicator up
Indicator down
Light-ON when Operating Light-ON when Not Operating
Light-ON when Not Operating
WL-N/WL
18
Operation
Note: 1. Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating
current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website.
2. For details on accessories (sold separately), refer to page 79.
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed
down.
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the
actuator rotates or is pushed down.
*3. The wiring varies depending on when the loads and indicator lamps are operating.
For contacts that include an internal circuit (indicator circuit), connect a resistor for protection.
To find the resistance value and capacity, calculate using the voltage, current, and power that is actually used.
· Resistance (Ω) = Voltage (V) ÷ Current (I)
· Power (W) = Current (A) × Voltage (V)
· Capacity (W) = Power (W) × Margin (approximately 2×)
Use the values below for reference.
Reference: Example of Protection Resistance
The capacity value is a numerical value that does not account for the margin. Select a resistor with sufficient capacity.
When calculating using the leakage current in this catalog, the display becomes slightly dim.
Use of a current that is at least around twice the leakage current is recommended.
Internal Circuits
Operation indicator type Operation type When load is connected to NC (11-12) When load is connected to NO (13-14)
LED (WL@-LD-N)
Neon lamp (WL@-LE-N)
Light-ON when
operating *1
Light-ON when not
operating *2
Model Indicator Voltage Protection resistance (example)
Type Leakage current Resistance Capacity
WL@LD@-N LED
Approx. 0.5 mA 115 VAC/DC Approx. 50 kΩ0.27 W min.
Approx. 0.4 mA 24 VAC/DC Approx. 10 kΩ0.06 W min.
10 VAC/DC Approx. 10 kΩ0.01 W min.
WL@LE@-N Neon lamp Approx. 1.9 mA 250 VAC Approx. 100 kΩ0.63 W min.
Approx. 0.6 mA 125 VAC Approx. 100 kΩ0.16 W min.
LED (WL@-LD-N)
Neon lamp (WL@-LE-N)
13
Za
12
14
11
Power
Built-in switch
Internal
circuits
Load
13
Za
12
*3
14
11
Power
Built-in switch
Internal
circuits
Load
13
12
*3
14
11
Za
Power
Built-in switch
Internal
circuits
Load
13
12
14
11
Za
Power
Built-in switch
Internal
circuits
Load
Contact spring Rectifier stack
Rated
current
diode
LED
Zener
diode
Resistor
Resistor
Contact spring
Neon lamp
Resistor
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
19
Dimensions (Unit: mm)
Roller Lever
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLCA2(-55)-N
WLCA2-(55)LD-N
WLCA2-(55)LE-N
WLCA2-2(-55)-N
WLCA2-2(55)LD-N
WLCA2-2(55)LE-N
WLCA2-2N(-55)-N
WLCA2-2N-(55)LD-N
WLCA2-2N-(55)LE-N
WLG2(-55)
WLG2-(55)LD
WLG2-(55)LE
WLGCA2(-55)
WLGCA2-(55)LD
WLGCA2-(55)LE
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
9.81 N
0.98 N
10°
65°
13.34 N
1.47 N
40°
17.5×7 dia. *
(125)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R38
Four, 5.2 dia. holes
2-M3.5
Three, M4
* Stainless sintered roller
5
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
M5
Allen-head bolt
JIS B 0202 G½
68.7
21.6
53.2±0.8
42 max.
29.2±1.2 Four, M6
Depth: 15 min.
25.4
25.4
13.1
Roller lever R38
WLCA2(-55)-N
WLCA2-2(55)-N
WLCA2-2N(55)-N
Note: The photo shows the
WLCA2-N model.
40±0.7
30.2±0.2
* Stainless sintered roller
53.2±0.8
42 max.
29.2±1.5
21.6
68.7
25.4
60 max.
53±1.5
41.5±1.5
40±1.5
25.4
13.1
12.7
R38
17.5×7 dia. *
(125)
(4.9) (15.1)
58.7±0.2
14.7
Four, M6
Depth: 15 min.
2-M3.5
M5
Allen-head
bolt
Three, M4
Four, 5.2 dia. holes
5
JIS B 0202 G½
Roller lever R38 With operation indicator
LED
WLCA2-(55)LD-N
WLCA2-2(55)LD-N
WLCA2-2N(55)LD-N
Neon lamp
WLCA2-(55)LE-N
WLCA2-2(55)LE-N
WLCA2-2N(55)LE-N
Note: The photo shows the
WLCA2-LD-N model.
Three, M4
* Stainless sintered roller
Four, 5.2 dia.
holes
14.7
30.2
±0.2
40
±0.7
(4.9)(15.1)
58.7
±0.2
5
(125)
R38
4-M3.5
17.5×7 dia. *
M5
Allen-head bolt
JIS B0202 G½Four, M6
Depth: 15 min
60 max.
25.4
68.7
12.7
25.4
13.1
40
±1.5
41.5
±1.5
53
±1.5
42 max.
53.2
±0.8
29.2
21.6
±1.2
Roller lever R38
WLG2(-55)
WLGCA2(-55)
Note: The photo shows
the WLG2 model.
JIS B0202 G½
* Stainless sintered roller
14.7
30.2
±0.2
40±0.7
(4.9)(15.1)
58.7±0.2
5
(125)
R38M5
Allen-head
bolt
Three, M4
Four, 5.2 dia.
holes
Four, M3.5
17.5×7 dia. *
60 max.
13.1
40
±1.5
41.5
±1.5
53±1.5
Four, M6
Depth: 15 min
25.4
68.7
42 max.
53.2±0.8
29.2
±1.2
12.7
25.4
21.6
Roller lever R38 With operation indicator
LED
WLG2-(55)LD
WLGCA2-(55)LD
Neon lamp
WLG2-(55)LE
WLGCA2-(55)LE
Note: The photo shows the
WLG2-LD model.
+2°
-1°
+2°
WL-N/WL
20
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
WLCA2-7-N
WLCA2-7LD-N
WLCA2-7LE-N
WLCA2-8-N
WLCA2-8LD-N
WLCA2-8LE-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
10.2 N
0.9 N
15±5°
70°
12°
8.04 N
0.71 N
15±5°
70°
12°
17.5×15 dia. *
(137)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R50 Two, M3.5
Three, M4
Four, 5.2 dia.
holes
* Stainless sintered roller
5
67.2 max.
12.7
41.5±1.5
58.1±1.5
M5
Allen-head bolt
JIS B 0202 G½
68.7
21.6
53.2±0.8
42 max.
29.2±1.2 Four, M6
Depth: 15 min.
25.4
25.4
13.1
36±1.5
Roller lever R50
WLCA2-7-N
5
(137) 14.7
R50
17.5×15 dia. *
58.7±0.2
* Stainless sintered roller
40±0.7
30.2
±0.2
29.2±1.2
42 max.
53.2±0.8
58.1±1.5
36±1.5
41.5±1.5
67.2 max.
(4.9)
(15.1)
Four, 5.2 dia.
holes
Two, M3.5
Three, M4
12.7
M5
Allen-head bolt
JIS B 0202 G½
68.7
21.6 Four, M6
Depth: 15 min.
25.4
25.4
13.1
34
Roller lever R50 With operation indicator
LED
WLCA2-7LD-N
Neon lamp
WLCA2-7LE-N
Note: The photo shows the
WLCA2-7LD-N model.
M5
Allen-head bolt
17.5×7 dia. *
(150)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R63 Two, M3.5
Three, M4
Four, 5.2 dia. holes
* Stainless sintered roller
5
60 max.
12.7
41.5±1.5
40±1.5
53±1.5
JIS B 0202 G½
68.7
21.6
53.2±0.8
42 max.
29.2±1.2 Four, M6
Depth: 15 min.
25.4
25.4
13.1
Roller lever R63
WLCA2-8-N
R63
14.7
58.7±0.2
(150)
40
±0.7
30.2±0.2
53.2
±0.8
42 max.
29.2±1.2
21.6
(
15.1
)
Two, M3.5
* Stainless sintered roller
5
60 max.
12.7
40
±1.5
41.5
±1.5
53
±1.5
M5
Allen-head bolt
JIS B 0202 G½
68.7
Four, M6
Depth: 15 min.
25.4
25.4 13.1
17.5×7 dia. *
3-M4
Four, 5.2 dia.
holes
(4.9)
Roller lever R63 With operation indicator
LED
WLCA2-8LD-N
Neon lamp
WLCA2-8LE-N
Note: The photo shows the
WLCA2-8LD-N model.
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
21
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
* The operating characteristics are measured at the lever length of 38 mm.
Model
WLCA12 (-55) -N *
WLCA12- (55) LD-N *
WLCA12- (55) LE-N *
WLCA12-2-N *
WLCA12-2LD-N *
WLCA12-2LE-N *
WLCA12-2N-N *
WLCA12-2NLD-N *
WLCA12-2NLE-N *
WLG12 *
WLG12-LD *
WLG12-LE *
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
9.81 N
0.98 N
10°
65°
17.5×7 dia. *
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
Two, M3.5
3-M4
Four, 5.2 dia.
holes
* Stainless sintered roller
5
Adjustable range:
25 to 89
67 max.
12.7
41.5±1.5
60±1.5
M5
Allen-head
bolt
JIS B 0202 G½
68.7
65.2±0.8
42 max.
21.6
29.2±1.2
Four, M6
Depth: 15 min.
25.4
25.4
13.1
Adjustable Roller Lever (R25 to 89 mm)
WLCA12(-55)-N
WLCA12-2-N
WLCA12-2N-N
Note: The photo shows the WLCA12-N model.
17.5×7 dia. *
(4.9)
40±0.7
30.2
±0.2
58.7±0.2
14.7
Adjustable range:
28 to 89Four, 5.2 dia.
holes
Two, M3.5
Three, M4
* Stainless sintered roller
5
67 max.
12.7
41.5±1.5
60±1.5
M5 lever
length adjustment
Allen-head bolt
M5Lever locking
Allen-head bolt
JIS B 0202
68.7
21.6
65.2±0.8
42 max.
29.2
±1.2
Four, M6
Depth: 15 min.
25.4
25.4
13.1
(
15.1
)
Adjustable Roller Lever (R25 to 89 mm)
With operation indicator
LED
WLCA12-(55)LD-N
WLCA12-2LD-N
WLCA12-2NLD-N
Note: The photo shows the WLCA12-LD-N model.
Neon lamp
WLCA12-(55)LE-N
WLCA12-2LE-N
WLCA12-2NLE-N
14.7
M5
Allen-head bolt
Three, M4
JIS B0202 G
½Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2 dia.
holes
67 max.
25.4
68.7
12.7
25.4
13.1
41.5
±1.5
60±1.5
30.2
±0.2
40±0.7
(4.9)(15.1)
58.7±0.2
5
Adjustable range:
28 to 89
Four, M3.5
17.5×7 dia. *
42 max.
65.2±0.8
29.2
21.6
±1.2
Adjustable Roller Lever (R25 to 89 mm)
WLG12
14.7
58.7
±0.2
40
±0.7
30.2
±0.2
65.2
±0.8
JIS B0202 G
½
Four, M6
Depth: 15 min.
* Stainless sintered roller
67 max.
25.4
68.7
12.7
25.4
13.1
41.5
±1.5
60
±1.5
(4.9)(
15.1
)
5
Adjustable range:
28 to 89
Four, M3.5
17.5×7 dia. *
42 max.
29.2
±1.2
21.6
Three, M4
Four, 5.2 dia.
holes
M5
Allen-head
bolt
Adjustable Roller Lever (R25 to 89 mm)
With operation indicator
LED
WLG12-LD
Note: The photo shows the WLG12-LD model.
Neon lamp
WLG12-LE
+2°
-1°
WL-N/WL
22
Direct-wire connector
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLCA2-LDK13A-N
WLCA2-(55)LDK13-N
WLCA2-LDK43A-N
WLCA2-(55)LDK43-N
WLG2-(55)LDK13
WLG2-(55)LDK43
WLCA2-(55)LDK13
WLCA2-(55)LDK43
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
40±0.7
30.2±0.2
R38
* Stainless sintered roller
17.5×7 dia. *
(125)
12.5
(4.9) (15.1)
58.7±0.2
14.7
Two, M3.5
M12×1
Three, M4
Four, 5.2 dia. holes
5
68.7
53.2±0.8
42 max.
29.2±1.2 Four, M6
Depth: 15 min.
25.4
60 max.
12.7
40±1.5
41.5
±1.5
53±1.5
25.4
13.1
M5
Allen-head bolt
Roller lever R38 With operation indicator
LED
WLCA2-LDK13A-N
WLCA2-(55)LDK13-N
WLCA2-LDK43A-N
WLCA2-(55)LDK43-N
Note: The photo shows the WLCA2-LDK13-N model.
* Stainless sintered roller
14.7
30.2
±0.2
40±0.7
(4.9)
(15.1)
58.7±0.2
5
(125)
R38 M5
Allen-head bolt
Four, M3.5
17.5×7 dia. *
60 max.
13.1
40
±1.5
41.5
±1.5
53±1.5
Four, M6
Depth: 15 min.
25.4
68.7
42 max.
53.2±0.8
12.7
25.4
M12×1
Four, 5.2 dia.
holes
12.5
Three, M4
SC-2FD
29.2
±1.2
21.6
Roller lever R38 With operation indicator
LED
WLG2-(55)LDK13
WLG2-(55)LDK43
WLGCA2-(55)LDK13
WLGCA2-(55)LDK43
Note: The photo shows the WLG2-LDK13 model.
+2°
-1°
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
23
Pre-wired connectors
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLCA2-(55)LD-M1J-N
WLCA2-(55)LD-M1GJ-N
WLCA2-(55)LD-M1JB-N
WLCA2-(55)LD-DGJ-N
WLCA2-(55)LD-DK1EJ-N
WLCA2-(55)LD-DTGJ-N
WLCA2-LD-DTK1EJ-N
WLG2-(55)LD-M1J
WLG2-(55)LD-M1GJ
WLG2-(55)LD-M1JB
WLG2-(55)LD-DGJ03
WLG2-(55)LD-DK1EJ03
WLG2-(55)LD-M1TJ
WLG2-(55)LD-M1TGJ
WLG2-(55)LD-M1TJB
WLG2-(55)LD-DTGJ03
WLG2-(55)LD-DTK1EJ03
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
40±0.7
30.2±0.2
* Stainless sintered roller
17.5×7 dia. *
SC-1M
(125)
(4.9)
(15.1)
58.7±0.2
14.7
Two, M3.5
Three, M4
Four, 5.2 dia.
holes
5
XS2H-D421
R38
53.2±0.8
+100
-50
42 max.
29.2±1.2
68.7
25.4
60 max.
41.5±1.5
40±1.5
53±1.5
25.4
12.7
13.1
M5
Allen-head
bolt
300
Four, M6
Depth: 15 min.
Roller lever R38 With operation indicator
LED
Threaded (M12)
WLCA2-(55)LD-M1J-N
WLCA2-(55)LD-M1GJ-N
WLCA2-(55)LD-DGJ-N
WLCA2-(55)LD-DK1EJ-N
Smartclick
WLCA2(55)LD-DTGJ-N
WLCA2-LD-DTK1EJ-N
Note: The photo shows the WLCA2-LD-M1J-N model.
* Stainless sintered roller
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
(125)
R38
Four, 5.2 dia.
holes
Four-M3.5
17.5×7 dia. *
60 max.
13.1
40
±1.5
41.5
±1.5
53±1.5
Four, M6
Depth: 15 min.
25.4
68.7
42 max.
53.2±0.8
29.2
±1.2
12.7
25.4
21.6
XS5H-D421
Three, M4
M5
Allen-head
bolt
SC-1M
+100
-50
300
Roller lever R38 With operation indicator
LED
Threaded (M12)
WLG2-(55)LD-M1J
WLG2-(55)LD-M1GJ
WLG2-(55)LD-M1JB
WLG2-(55)LD-DGJ03
WLG2-(55)LD-DK1EJ03
Smartclick
WLG2-(55)LD-M1TJ
WLG2-(55)LD-M1TGJ
WLG2-(55)LD-M1TJB
WLG2-(55)LD-DTGJ03
WLG2-(55)LD-DTK1EJ03
+2°
-1°
WL-N/WL
24
Plunger Actuators
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLD28(-55)-N
WLD28-(55)LD-N
WLD28-(55)LE-N
WLD2(-55)-N
WLD2-(55)LD-N
WLD2-(55)LE-N
WLD18-N
WLD18-LD-N
WLD18-LE-N
WLD38-N
WLD38-LD-N
WLD38-LE-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
26.67 N
8.92 N
1.7 mm
5.6 mm
1 mm
26.67 N
8.92 N
1.7 mm
6.4 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
Operating position
Total travel position
OP
TTP max.
44±0.8 mm
39.5 mm
44±0.8 mm
39.5 mm
34±0.8 mm
29.5 mm
44.5±0.8 mm
41 mm
PT
Three, M4
Four, 5.2 dia.
holes
Two, M3.5
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
OP
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2±1.2
42 max.
68.7
* Stainless sintered roller
14.3×5
dia. *
Sealed top-roller plunger
WLD28(-55)-N
PT
3-M4
Four, 5.2 dia.
holes
Lamp cover
Two, M3.5
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
OP
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2±1.2
42 max.
68.7
*Stainless
sintered roller
14.3×5
dia. *
Sealed top-roller plunger With operation indicator
LED
WLD28-(55)LD-N
Neon lamp
WLD28-(55)LE-N
Note: The photo shows the WLD28-LD-N model.
Four, 5.2 dia.
holes
17×4.6
dia. *
PT
30.2±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP Four, M3.5
Three, M4
13.1
12.9
21.6
29.2±1.2
42 max.
68.7
28.4
JIS B0202 G½Four, M6
Depth: 15 min.
* Stainless sintered roller
Top-roller plunger
WLD2(-55)-N
Four, 5.2 dia.
holes
Lamp cover
PT
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP 4-M3.5
Three, M4
13.1
12.9
21.6
29.2
±1.2
42 max.
68.7
28.4
JIS B0202 G½Four, M6
Depth: 15 min.
* Stainless
sintered roller
17×4.6 dia. *
Four, 5.2 dia.
holes
Sealed top-roller plunger With operation indicator
LED
WLD2-(55)LD-N
Neon lamp
WLD2-(55)LE-N
Note: The photo shows the WLD2-LE-N model.
PT
13.1
12.9
21.6
* Stainless steel plunger
Three, M4
Four, 5.2 dia.
holes
R1 *
2-M3.5
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
10 dia.
OP
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Sealed top plunger
WLD18-N
PT
13.1
12.9
21.6
* Stainless
steel plunger
3-M4
Four, 5.2 dia.
holes
Lamp cover
R1*
Rubber cap
2-M3.5
30.2
±0.2
40±0.7
(4.9)
5
(15.1)
10 dia.
JIS B0202 G½
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
OP
58.7±0.2 68.7
Sealed top-roller plunger With operation indicator
LED
WLD18-LD-N
Neon lamp
WLD18-LE-N
Note: The photo shows the WLD18-LD-N model.
PT
Three, M4
Four, 5.2 dia.
2-M3.5
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP
13.1
12.9
21.6
JIS B0202 G½
Four, M6
Depth: 15 min.
29.2±1.2
42 max.
68.7
*
Stainless steel ball
1/2" dia. *
15.5 dia.
Sealed top-ball plunger
WLD38-N
PT
Three, M4
Lamp cover
Four, 5.2 dia.
holes
Two, M3.5
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
OP
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2
±1.2
68.7
* Stainless
steel ball
1/2"
dia. *
15.5 dia.
42 max.
Sealed top-ball plunger With operation indicator
LED
WLD38-LD-N
Neon lamp
WLD38-LE-N
Note: The photo shows the WLD38-LD-N model.
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
25
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLSD(-55)-N
WLSD-(55)LD-N
WLSD-LE-N
WLSD2(-55)-N
WLSD2-(55)LD-N
WLSD2-LE-N
WLSD3-N
WLSD3-LD-N
WLSD3-LE-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
4 mm
1 mm
Operating position
Total travel position
OP
TTP max.
40.6±0.8 mm
---
54.2±0.8 mm
---
54.1±0.8 mm
---
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
13.1
12.7
21.6
JIS B0202 G
½
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
27.5
46.6
±0.8
OP
PT
*1
.
Stainless steel plunger
*2. Cosmetic nuts
25 dia. *2
Two, M3.5
17.8
(96.2)
25.4
R1
9.3 dia. *1
Horizontal plunger
WLSD(-55)-N
Three, M4
Lamp cover
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
25.4
12.7
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2±1.2
42 max.
46.6±0.8
OP
PT
Two, M3.5
17.8
(96.2)
25.4
9.3 dia.*
1
27.5
68.7
*1 Stainless steel
plunger
* 2. Cosmetic nuts
25 dia.*2
Horizontal plunger With operation indicator
LED
WLSD-(55)LD-N
Neon lamp
WLSD-LE-N
Note: The photo shows the WLSD-LD-N model.
Three, M4
Four, 5.2 dia.
holes
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.7
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2±1.2
42 max.
68.7
55.7±0.8
* 1.Stainless sintered roller
* 2. Cosmetic nuts
25 dia. *2
Two, M3.5
17.8
(96.2)
25.4
PT OP
17×4.6 dia. *
1
27.5
Horizontal-roller plunger
WLSD2(-55)-N
Three, M4
Lamp cover
Four, 5.2 dia.
holes
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
25.4
12.7
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2±1.2
42 max.
68.7
55.7±0.8
*
1.
Stainless
sintered roller
*
2.
Cosmetic nuts
25 dia.*2
Two, M3.5
17.8
(96.2)
25.4
PT OP
17×4.6 dia.*1
27.5
Note: The photo shows the WLSD2-LD-N model.
Horizontal-roller plunger With operation indicator
LED
WLSD2-(55)LD-N
Neon lamp
WLSD2-LE-N
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
13.1
12.7
21.6
JIS B0202 G½
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
46.6
±0.8
* 1. Stainless steel ball
*
2. Cosmetic nuts
25
dia.
*
2
Two, M3.5
17.8
(96.2)
25.4
PT OP
15.5
dia.
1/2"
dia.
*
1
27.5
Horizontal-ball plunger
WLSD3-N
Three, M4
Four, 5.2 dia.
holes
Lamp cover
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
13.1
12.7
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
46.6
±0.8
*1.
Stainless
steel ball
*2. Cosmetic nuts
25
dia.
*2
Two, M3.5
17.8
(96.2)
25.4
PT OP
15.5 dia.
1/2" dia. *1
27.5
Horizontal-ball plunger With operation indicator
LED
WLSD3-LD-N
Neon lamp
WLSD3-LE-N
Note: The photo shows the WLSD3-LD-N model.
WL-N/WL
26
Direct-wire connector
Pre-wired connectors
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLD28-(55)LDK13-N
WLD28-(55)LDK43-N
WLD28-(55)LD-M1J-N
WLD28-(55)LD-M1GJ-N
WLD28-(55)LD-DGJ-N
WLD28-(55)LD-DK1EJ-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
Operating position
Total travel position
OP
TTP max.
44±0.8 mm
39.5 mm
PT
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP
Four, 5.2 dia.
holes
Two, M3.5
SC-2FD
13.1
12.9
68.7
Four, M6
Depth: 15 min.
21.6
29.2
±1.2
42 max.
JIS B0202 G½
14.3x5 dia. *
* Stainless
sintered roller
Three, M4
Sealed top-roller plunger With operation indicator
LED
WLD28-(55)LDK13-N
WLD28-(55)LDK43-N
Note: The photo shows the WLD28-LDK13-N model.
PT
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP
* Stainless sintered roller
Four, 5.2 dia.
holes
Two, M3.5
14.3x5 dia. *
Three, M4
13.1
12.9
68.7
Four, M6
Depth: 15 min.
21.6
29.2
±1.2
42 max.
(20)
300
+100
-50
XS2H-D421
SC-1M
Sealed top-roller plunger With operation indicator
Threaded (M12)
LED
WLD28-(55)LD-M1J-N
WLD28-(55)LD-M1GJ-N
WLD28-(55)LD-DGJ-N
Note: The photo shows the WLD28-LD-M1J-N model.
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
27
Flexible Rod
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
*1. The operating characteristics are measured at the lever length of 140 mm.
*2. This is the value when the rod length is 140 mm.
Model
WLCL(-55)-N *1
WLCL-LD-N *1
WLCL-LE-N *1
WLCL-2-N *1
WLCL-2LD-N *1
WLCL-2LE-N *1
WLCL-2N-N *1
WLCL-2NLD-N *1
WLCL-2NLE-N *1
WLGL *2
WLGL-LD *2
WLGL-LE *2
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
1.39 N
0.27 N
15±5°
70°
12°
1.39 N
0.27 N
25±5°
60°
16°
1.39 N
0.27 N
20° max.
70°
10°
2.84 N
0.25 N
10°
65°
9
(4.9) (15.1)
40±0.7
30.2±0.2
Three, M4
Two, M3.5
Four, 5.2 dia. holes
3±0.2 dia length: 160 *
58.7±0.2
5
14.7
* Stainless copper rod
55 max.
41.5±1.5
46±1.5
Lever locking
Allen-head bolt
Rod length
adjustment
Hexagon
socket set
screw
JIS B 0202 G½
68.7
42 max.
21.6
29.2±1.2
Four, M6
Depth: 15 min.
25.4
25.4
12.7
13.1
Adjustable range:
25 to 140
Adjustable rod lever (25 to 140 mm)
WLCL(-55)-N
WLCL-2-N
WLCL-2N-N
Note: The photo shows the
WLCL-2N-N model.
30.2
±0.2
40±0.7
58.7
±0.2
9
3-M4
Four, 5.2 dia. holes
(4.9)
5
(15.1)
41.5±1.5
21.6
JIS B0202 G
½
Four, M6
Depth: 15 min.
29.2
±1.2
Two, M3.5
Head-mounting screw
Stainless copper rod
14.7
Adjustable range:
25 to 140
55 max.
12.7
13.1
25.4
Lamp cover
Rod length
adjustment
Hexagon socket
set screw
42 max.
68.7
25.4
46
±1.5
Lever locking
Allen-head bolt
Adjustable rod lever (25 to 140 mm)
With operation indicator
LED
WLCL-(55)LD-N
WLCL-2LD-N
WLCL-2NLD-N
Neon lamp
WLCL-LE-N
WLCL-2LE-N
WLCL-2NLE-N
Note: The photo shows the
WLCL-2LD-N model.
Three, M4
Four, M6
Depth: 15 min.
* Stainless copper rod
55 max.
25.4
68.7
12.7
25.4
13.1
46±1.5
14.7
30.2±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
Four, M3.5
3±0.2 (length: 160) dia.*
42 max.
35
Adjustable range:
25 to 140
9
41.5±1.5
29.2
21.6
±1.2
JIS B 0202 G½
Four, 5.2 dia.
holes
Rod length adjustment
Hexagon socket set screw
Lever locking
Allen-head bolt
Adjustable rod lever (25 to 140 mm)
WLGL
Three, M4
Four, M6
Depth: 15 min.
* Stainless copper rod
55 max.
12.7
25.4
13.1
46
±1.5
14.7
30.2±0.2
40
±0.7
(4.9)
(15.1)
58.7
±0.2
5
Four, M3.5
3×160(length:160)
*
dia
42 max.
Adjustable range:
25 to 140
9
41.5
±1.5
29.2±1.2
21.6
25.4
68.7
Four, 5.2 dia.
holes
JIS B 0202
Rod length adjustment
Hexagon socket set screw
Lever locking
Allen-head bolt
Adjustable Roller Lever (25 to 140 mm)
With operation indicator
LED
WLGL-LD
Neon lamp
WLGL-LE
+2°
-1°
WL-N/WL
28
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Note: 1. With WLCAL4-LD-N, WLCAL4-LE-N, WLCAL5-LD-N, and WLCAL5-LE-N, the actuator's tare is large, so depending on the installation
direction, they may not be properly reset. Always install so that the actuator is facing downwards.
2. This is the value when the rod length is 380 mm.
Model
WLCAL4-N
WLCAL4-LD-N
WLCAL4-LE-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
0.98 N
0.15 N
15±5°
70°
12°
8
(4.9) (15.1)
40±0.7
30.2±0.2
Three, M4
Four, 5.2 dia. holes
5
12.8
65
* Stainless copper rod
3.2 dia.*
Adjustable range:
350 to 380
14.7
58.7±0.2
41.5±1.5
JIS B 0202 G½
M5
Allen-head
bolt
68.7
42 max.
21.6
29.2±1.2
25.4
25.4
54.5±1.5
67 max.
13.1
12.7
Four, M6
Depth: 15 min.
Adjustable rod lever (350 to 380 mm)
WLCAL4-N
Adjustable Roller Lever (350 to 380 mm)
With operation indicator
LED
WLCAL4-LD-N
Neon lamp
WLCAL4-LE-N
58.7±0.2 3-M4
12.8
3.2 dia.
Stainless copper rod
Four, 5.2 dia.
holes
(4.9)
5
(15.1)
41.5±1.5
54.5±1.5
21.6
JIS B0202 G
½
Four, M6
Depth: 15 min
2-M3.5
Head-mounting screw
14.7
11
12.7
13.1
25.4
Lamp cover
lever locking
Allen-head bolt
Lever length
adjustment
Allen-head
65
40±0.7
30.2
±0.2
Adjustable range:
350 to 380
25.4
68.7
67 max.
42 max.
29.2
±1.2
34
8
Note: The photo shows the WLCAL4-LD-N model.
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
29
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Note: 1. With WLCAL4-LD-N, WLCAL4-LE-N, WLCAL5-LD-N, and WLCAL5-LE-N, the actuator's tare is large, so depending on the installation
direction, they may not be properly reset. Always install so that the actuator is facing downwards.
2. This is the value when the rod length is 380 mm.
Model
WLCAL5-N
WLCAL5-LD-N
WLCAL5-LE-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
0.9 N
0.09 N
15±5°
70°
12°
Rod spring lever
WLCAL5-N
67 max.
(4.9) (15.1)
40±0.7
30.2±0.2
Three, M4
5
*Piano wire
65
11
2.3 dia*
14.7
58.7±0.2
428.5±2
Four, 5.2 dia.
holes
41.5±1.5
Four, M6
Depth: 15 min.
JIS B 0202 G½
M5
Allen-head bolt
68.7
21.6
29.2±1.2
25.4
25.4
54.5±1.5
12.7
13.1
42 max.
7.5
58.7±0.2
Three, M4
7.5
2.3 dia.
Piano wire copper rod
Four, 5.2 dia.
holes
(4.9)
5
(15.1)
41.5±1.5
54.5±1.5
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
2-M3.5
Head-mounting screw
14.7
11
12.7
13.1
25.4
Lever locking
Allen-head bolt
40±0.7
30.2
±0.2
428.5±2
65
25.4
68.7
67 max.
42 max.
29.2
±1.2
34
Rod spring lever With operation indicator
LED
WLCAL5-LD-N
Neon lamp
WLCAL5-LE-N
Note: The photo shows the WLCAL5-LD-N model.
WL-N/WL
30
Flexible Rod
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Note: These values are for the top end of the spring, rod, or wire.
Model
WLNJ(-55)-N
WLNJ-(55)LD-N
WLNJ-LE-N
WLNJ-30-N
WLNJ-30LD-N
WLNJ-30LE-N
Operating force
Pretravel
OF
PT
max. 1.47 N
20±10 mm
1.47 N
20±10 mm
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(107)
33.7±0.8
140±2.5
6.5 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from
the end of the spring.
Coil spring
WLNJ(-55)-N
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G
½
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(107)
33.7±0.8
140±2.5
6.5 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from
the end of the spring.
Coil spring With operation indicator
LED
WLNJ-(55)LD-N
Neon lamp
WLNJ-LE-N
Note: The photo
shows the
WLNJ-LD-N
model.
Three, M4
Four, 5.2 dia.
holes
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(107)
33.7±0.8
140±2.5
4.8 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Piano wire coil spring.
*3. The range for operation is 1/3rd of the overall spring length from
the end of the spring.
Coil Spring (Multi-wire)
WLNJ-30-N
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(107)
33.7
±0.8
140±2.5
4.8 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Piano wire coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the
end of the spring.
Coil Spring (Multi-wire) With operation indicator
LED
WLNJ-30LD-N
Neon lamp
WLNJ-30LE-N
Note: The photo shows the WLNJ-30LD-N model.
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
31
Flexible Rod
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Note: These values are for the top end of the spring, rod, or wire.
Model
WLNJ-2(55)-N
WLNJ-2(55)LD-N
WLNJ-2LE-N
WLNJ-S2-N
WLNJ-S2LD-N
WLNJ-S2LE-N
Operating force
Pretravel
OF
PT
max. 1.47 N
40±20 mm
0.28 N
40±20 mm
26
dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Polyamide Resin Rod.
*3. The range for operation is 1/3rd of the overall rod length from the end
of the rod.
Three, M4
Four, 5.2 dia.
holes
30.2±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G½
Four, M6
Depth: 15 min.
29.2±1.2
68.7
Two, M3.5
*3
PT
*1
*2
(95.4)
44.6±0.8
140
±2.5
8
dia.
42 max.
Resin rod
WLNJ-2(55)-N
26
dia.
3-M4
Four, 5.2 dia.
holes
30.2±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(95.4)
44.6±0.8
140
±2.5
8
dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Polyamide Resin Rod.
*3. The range for operation is 1/3rd of the overall rod length from the
end of the rod.
Resin rod With operation indicator
LED
WLNJ-2(55)LD-N
Neon lamp
WLNJ-2LE-N
Note: The photo shows
the WLNJ-2LD-N
model.
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G
½Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(159)
33.7
±0.8
193±2.5
1 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel wire.
*3. The range for operation is 1/3rd of the overall wire length from the end
of the wire.
Steel wire
WLNJ-S2-N
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6
JIS B0202 G
½
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(161)
33.7
±0.8
193±2.5
1 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the
end of the spring.
Steel wire With operation indicator
LED
WLNJ-S2LD-N
Neon lamp
WLNJ-S2LE-N
Note:
The photo shows
the WLNJ-S2LD-N
model.
WL-N/WL
32
Fork Lock Lever
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model WLCA32-41 to WLCA32-44-N
Force necessary to reverse the direction of the lever
Movement until the lever reverses
Movement until switch operation
Movement after switch operation
max.
max.
min.
11.77 N
50±5°
55°
35°
13.1
12.7
21.6
62.5 max.
56.4±3.5
42.8±3.5
2-M3.5
Three, M4
Four, 5.2 dia.
holes
2-17.5×7 dia.*
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
(125)
14.7
Four, M6
Depth: 15 min.
JIS B0202 G
½
M5
Allen-head bolt
29.2±1.2
42 max.
68.7
34.1
25.4
*Plastic Roller
(The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.)
90°±3°
R38
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
WLCA32-44-N The WLCA32-41-N is shown in the following diagram.
Note: The photo shows the WLCA32-43-N model.
13.1
12.7
21.6
62.5 max.
56.4±3.5
42.8±3.5
Two, M3.5
Three, M4
Four, 5.2 dia.
holes
2-17.5×7 dia. *
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
(125)
14.7
Four, M6
Depth: 15 min.
JIS B0202 G
½
M5 lever locking
Allen-head bolt
29.2±1.2
68.7
34.1
25.4
90°±3°
R38
42 max.
*Plastic Roller
(The WLCA32-041L@-N to WLCA32-044L@-N have stainless steel rollers.)
With operation indicator
LED
WLCA32-41LD-N
WLCA32-43LD-N
Neon lamp
WLCA32-41LE-N
WLCA32-42LE-N
WLCA32-43LE-N
The WLCA32-41L@-N is shown in the
following diagram.
Note: The photo shows the WLCA32-43LD-N model.
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
33
Environment-resistant Limit Switches
WL-N/WL
Wide range of available models to
match your onsite environment
Variety of head shapes, including Roller Lever, Plunger,
and Flexible Rod Switches
Select the optimum actuator model for the ambient operating
temperature and operating environment for use in a wide
range of applications
Wiring specifications are available in Direct-wire cable types
in addition to standard screw terminals types
Features
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on pages 81 to 86 and
Safety Precautions for All Limit Switches.
Select based on the operating temperature
Ambient operating temperature of 5°C to 120°C: Heat-resistant type (WL@-TH-N/WL@-TH)
Ambient operating temperature of -40°C to 40°C: Cold-resistant type (WL@-TC-N/WL@-TC)
Select based on the operating environment
Outdoor use: Weather-resistant type (WL@-P1-N/WL@-P1)
Coolant drops and mist: Coolant-resistant type (WL@-RP60-N/WL-RP60)
Mist Molded terminal 139 type (WL@-139-N/WL@-139)
The SC connector can be removed, so it is possible to use flexible conduit for the cable.
Constant water drops and mist Molded terminal 140 type (WL@-140-N/WL@-140)
Constant water drops or splattering cutting powder Molded terminal 141 type (WL@-141-N/WL@-141)
(WL@-RP40-N/WL-RP40)
WL-N/WL
34
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Basic models
(1) Actuator and Property Specifications
(2) Housing/Sealed Rubber Specifications
(3) Temperature Specifications
*(2) Housing/Sealed Rubber Specifications Cannot be combined
with symbols RP or P1.
(4) Wiring and Built-in Switch Specifications
(5) Indicator Specifications
*(2) Housing/Sealed Rubber Specifications Cannot be combined
with symbols RP or P1.
(3) Temperature Specifications Cannot be combined with
symbols TH or TC.
WL@-@@@@-N
(1) (2) (3) (4) (5)
Code Actuator Pretravel
(PT)
CA2
Roller lever
Roller lever: (R38 mm)
15±5°
CA2-2 25±5°
CA2-2N 20° max.
CA12 Adjustable Roller Lever
(R25 to 89 mm)
15±5°
CA12-2 25±5°
CA12-2N
20° max.
D28
Plunger
Actuators
Sealed top-roller plunger
1.7 mm max.
D2 Top-roller plunger
1.7 mm max.
SD Horizontal plunger
2.8 mm max.
SD2 Horizontal-roller plunger
2.8 mm max.
CL
Flexible Rod
Actuators
Adjustable rod lever
(25 to 140mm)
15±5°
CL-12 25±5°
CL-2N 20° max.
NJ Coil spring (6.5 dia.) 20±10mm
NJ-2 Flexible rod: Resin rod (8 dia.) 40±20mm
Code Specifications
None Standard built-in switch
55 Airtight built-in switch
RP Corrosion-resistant type
P1 Weather-resistant type
Code Specifications
None Ambient operating temperature (-10 to +80°C)
TH Ambient operating temperature (5 to 120°C)
(Heat-resistant type) *
TC Ambient operating temperature (-40 to +40°C)
(Cold-resistant type) *
Code Terminal
shape
Internal
switch
Specifications
Mold specifications
None
Screw
terminals
(Conduit size:
G1/2)
Standard None
139
Direct-wire
cable
Standard Molded conduit opening and cover.
(The cover cannot be removed.)
140
Airtight
built-in
switch
Molded conduit opening, cover, and
cover mounting screws. (The cover
cannot be removed.)
141
Molded conduit opening, cover,
cover mounting screws, and head.
(The cover cannot be removed, and
head direction cannot be changed.)
RP40
Molded conduit opening and cover.
(The cover cannot be removed.) SC
Connector can be removed, so it is
possible to use flexible conduits for
the cable.
RP60
Molded conduit opening, cover,
cover mounting screws, and head
mounting screws. (The cover can-
not be removed, and head direction
cannot be changed.) Fluorine rub-
ber is used for all rubber parts.
Code Specifications
None No indicator
LD LED (10 to 115 V AC/DC) *
LE Neon lamp (125 to 250 VAC) *
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
35
High-sensitivity and High-precision Models
(1) Actuator and Property Specifications
(2) Built-in Switch/Housing/Sealed Rubber
(3) Temperature Specifications
*(2) Built-in Switch/Housing/Sealed Rubber Specifications Cannot
be combined with symbols RP or P1.
(4) Wiring and Built-in Switch Specifications
(5) Indicator Specifications
*(2) Built-in Switch/Housing/Sealed Rubber Specifications
Symbols: RP, P1
(3) Temperature Specifications Cannot be combined with
symbols TH or TC.
WLG@-@@@@
(1) (2) (3) (4) (5)
Code Actuator Pretravel
(PT)
2
Roller lever
Roller lever: R38 mm
High-sensitivity Models 10°
CA2 Roller lever: R38 mm
High-precision Models
12 Adjustable Roller Lever (R25 to 89
mm) high-sensitivity model 10°
LFlexible rod Adjustable rod lever (25 to 140
mm) high-sensitivity model 10°
Code Specifications
None Standard Built-in Switch
55 Airtight built-in switch
RP Corrosion-resistant type
P1 Weather-resistant type
Code Specifications
None Ambient operating temperature -10 to +80°C
TH Ambient operating temperature (5 to 120°C) (Heat-resistant type) *
TC Ambient operating temperature (-40 to +40°C) (Cold-resistant
type) *
+ 2°
- 1°
- 2°
+ 2°
- 1°
+ 2°
- 1°
Code Terminal
shape
Built-in
switch
specification
Mold specifications
None
Screw
terminals
(Conduit size:
G1/2)Standard
None
139 Direct-wire
cable
Molded conduit opening and cover.
(The cover cannot be removed.)
140
Direct-wire
cable
Airtight built-
in switch
Molded conduit opening, cover,
and cover mounting screws. (The
cover cannot be removed.)
141
Molded conduit opening, cover,
cover mounting screws, and head.
(The cover cannot be removed,
and head direction cannot be
changed.)
RP60
Molded conduit opening, cover,
cover mounting screws, and head
mounting screws. (The cover can-
not be removed, and head direc-
tion cannot be changed.) Fluorine
rubber is used for all rubber parts.
Code Specifications
None No indicator
LD LED (10 to 115 V AC/DC) *
LE Neon lamp (125 to 250 V AC) *
WL-N/WL
36
Ordering Information
Roller Lever
Apperance
Actuator Terminal shape Built-in switch specification/
Temperature Specifications
Pretravel
(PT)
Without operation
indicator
With operation indicator
Indicator * LED
Model
Wiring
Specifications
Model
Roller lever:
R38 mm
Screw terminals
(Conduit size: G
1
/
2
)
Heat-resistant type
15±5° WLCA2-TH-N --- ---
25±5° WLCA2-2TH-N --- ---
20° max. WLCA2-2NTH-N --- ---
10° WLG2-TH --- ---
WLGCA2-TH --- ---
Cold-resistant type
15±5° WLCA2-TC-N --- ---
25±5° WLCA2-2TC-N --- ---
20° max. WLCA2-2NTC-N --- ---
10° WLG2-TC --- ---
WLGCA2-TC --- ---
Corrosion-resistant type
15±5° WLCA2-RP-N --- ---
10° WLG2-RP --- ---
WLGCA2-RP --- ---
Weather-resistant type 15±5° WLCA2-P1-N --- ---
10° WLG2-P1 --- ---
Direct-wire cable
Coolant-resistant type
15±5° WLCA2-RP60-N NC wiring WLCA2-RP60LD2-N
NO wiring WLCA2-RP60LD3-N
25±5° WLCA2-2RP60-N NC wiring WLCA2-2RP60LD2-N
NO wiring WLCA2-2RP60LD3-N
10° WLG2-RP60 NC wiring WLG2-RP60LD2
NO wiring WLG2-RP60LD3
WLGCA2-RP60 NC wiring WLGCA2-RP60LD2
NO wiring WLGCA2-RP60LD3
Corrosion-resistant type 15±5° WLCA2-RP40-N --- ---
Molded terminal -139
15±5° WLCA2-139-N NC wiring WLCA2-139LD2-N
NO wiring WLCA2-139LD3-N
25±5° WLCA2-2139-N NC wiring WLCA2-2139LD2-N
NO wiring WLCA2-2139LD3-N
20° max. WLCA2-2N139-N --- ---
10° WLG2-139 NO wiring WLG2-139LD3
WLGCA2-139 NC wiring WLGCA2-139LD2
NO wiring WLGCA2-139LD3
Molded terminal -140
15±5° WLCA2-140-N --- ---
20° max. WLCA2-2N140-N --- ---
10° WLG2-140 NC wiring WLG2-140LD2
NO wiring WLG2-140LD3
Molded terminal -141
15±5° WLCA2-141-N NC wiring WLCA2-141LD2-N
NO wiring WLCA2-141LD3-N
10° WLG2-141 NC wiring WLG2-141LD2
NO wiring WLG2-141LD3
WLGCA2-141 NO wiring WLGCA2-141LD3
+2°
-1
+2°
+2°
-1°
+2°
+2°
-1°
+2°
+2°
-1°
+2°
-1
+2°
0
+2°
-1°
+2°
0
+2°
-1°
+2°
-1°
+2°
0
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
37
Plunger
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
Apperance
Actuator Terminal shape Built-in switch specification/
Temperature Specifications
Pretravel
(PT)
Without operation
indicator
Model
Adjustable
roller lever
(R25 to 89
mm)
Screw terminals
(Conduit size: G
1
/
2
)
Heat-resistant type
15±5° WLCA12-TH-N
25±5° WLCA12-2TH-N
20° max. WLCA12-2NTH-N
10° WLG12-TH
Cold-resistant type
15±5° WLCA12-TC-N
25±5° WLCA12-2TC-N
20° max. WLCA12-2NTC-N
10° WLG12-TC
Corrosion-resistant type 15±5° WLCA12-RP-N
10° WLG12-RP
Weather-resistant type 15±5° WLCA12-P1-N
10° WLG12-P1
Direct-wire cable
Coolant-resistant type 15±5° WLCA12-RP60-N
Molded terminal -139 15±5° WLCA12-139-N
Molded terminal -140 15±5° WLCA12-140-N
Molded terminal -141 15±5° WLCA12-141-N
Apperance
Actuator Terminal shape Built-in switch specification/
Temperature Specifications Pretravel (PT) Without operation indicator
Model
Sealed top-roller plunger
Screw terminals
(Conduit size: G1/2)
Heat-resistant type
1.7 mm max.
WLD28-TH-N
Cold-resistant type WLD28-TC-N
Corrosion-resistant type WLD28-RP-N
Direct-wire cable
Coolant-resistant type WLD28-RP60-N
Molded terminal -139 WLD28-139-N
Molded terminal -140 WLD28-140-N
Top-roller plunger
Screw terminals
(Conduit size: G1/2)Heat-resistant type WLD2-TH-N
Direct-wire cable Coolant-resistant type WLD2-RP60-N
Molded terminal -139 WLD2-139-N
Horizontal plunger
Screw terminals
(Conduit size: G1/2)
Heat-resistant type
2.8 mm max.
WLSD-TH-N
Cold-resistant type WLSD-TC-N
Corrosion-resistant type WLSD-RP-N
Direct-wire cable Coolant-resistant type WLSD-RP60-N
Molded terminal -139 WLSD-139-N
Horizontal-roller plunger
Screw terminals
(Conduit size: G1/2)
Heat-resistant type WLSD2-TH-N
Cold-resistant type WLSD2-TC-N
Corrosion-resistant type WLSD2-RP-N
Direct-wire cable
Coolant-resistant type WLSD2-RP60-N
Molded terminal -139 WLSD2-139-N
Molded terminal -140 WLSD2-140-N
+2°
-1°
+2°
-1°
+2°
-1°
+2°
-1°
WL-N/WL
38
Flexible Rod
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
Apperance
Actuator Terminal shape Built-in switch specification/
Temperature Specifications Pretravel (PT) Without operation indicator
Model
Coil spring (6.5 dia.)
Screw terminals
(Conduit size: G1/2)
Heat-resistant type
20±10 mm
WLNJ-TH-N
Cold-resistant type WLNJ-TC-N
Corrosion-resistant type WLNJ-RP-N
Direct-wire cable
Coolant-resistant type WLNJ-RP60-N
Molded terminal -139 WLNJ-139-N
Molded terminal -140 WLNJ-140-N
Resin rod (8 dia.)
Screw terminals
(Conduit size: G1/2)Corrosion-resistant type 40±20 mm WLNJ-2RP-N
Direct-wire cable
Coolant-resistant type
40±20 mm
WLNJ-2RP60-N
Molded terminal -139 WLNJ-2139-N
Molded terminal -140 WLNJ-2140-N
Adjustable rod lever
(25 to 140 mm)
Screw terminals
(Conduit size: G1/2)
Heat-resistant type
15±5° WLCL-TH-N
25±5° WLCL-2TH-N
20° max. WLCL-2NTH-N
10° WLGL-TH
Cold-resistant type
15±5° WLCL-TC-N
25±5° WLCL-2TC-N
20° max. WLCL-2NTC-N
10° WLGL-TC
Corrosion-resistant type 15±5° WLCL-RP-N
10° WLGL-RP
Weather-resistant type 15±5° WLCL-P1-N
10° WLGL-P1
Direct-wire cable
Coolant-resistant type 15±5° WLCL-RP60-N
Molded terminal -139 15±5° WLCL-139-N
Molded terminal -140 15±5° WLCL-140-N
+2°
-1°
+2°
-1°
+2°
-1°
+2°
-1°
WL-N/WL
39
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
Specifications
Ratings
Screw terminals
Without Operation Indicator
With Operation Indicator (LED)
With Operation Indicators (Neon Lamps)
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Allowable Inrush Current/ Minimum applicable load
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC
125 10 3 1.5 5 --- 10 5 2.5 --- ---
250 10 2 1 5 --- 10 3 1.5 --- ---
500 10 1.5 0.8 --- --- 3 1.5 0.8 --- ---
DC
810 6 3 --- --- 10 6 --- ---
14 10 6 3 --- --- 10 6 --- ---
30 6 4 3 --- --- 6 4 --- ---
125 0.8 0.2 0.2 0.4 --- 0.8 0.2 --- ---
250 0.4 0.1 0.1 0.2 --- 0.4 0.1 --- ---
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 115 10 3 1.5 5 --- 10 5 2.5 --- ---
DC
12 10 6 3 --- --- 10 6 --- ---
24 6 4 3 --- --- 6 4 --- ---
48 3 2 1.5 --- --- 3 0.2 --- ---
115 0.8 0.2 0.4 --- 0.8 0.1 --- ---
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 5 --- 10 5 2.5 --- ---
250 10 2 1 5 --- 10 3 1.5 --- ---
Operating characteristics type Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Inrush current NC 30 A max. 15 A max.
NO 20 A max. 10 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
WL-N/WL
40
Direct-wire cable
Connector DC Specifications: With Operation Indicators (LEDs)
Connector AC Specifications: With Operation Indicators (LEDs)
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Allowable Inrush Current/ Minimum applicable load
Operation Indicator
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
DC
12 3 3 --- --- 3 3 --- ---
24 3 3 --- --- 3 3 --- ---
48 4 2 1.5 --- --- 3 2 --- ---
115 0.8 0.2 0.2 0.4 --- 0.8 0.2 --- ---
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 115 3 3 1.5 3 --- --- 3 3 2.5 --- --- ---
Operating characteristics type Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Inrush current NC 3 A max.
NO 3 A max.
Minimum applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
Operation indicator type LED Neon lamp
Model
WL-LD-N
WL-LW-N
WL-LD
WL-LE-N
WL-LE
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current (Reference value) Approx. 0.4 mA at 10 VAC/DC; Approx. 0.5 mA at 115 VAC/DC Approx. 0.6 mA at 125 VAC; Approx. 1.9 mA at 250 VAC
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
41
Characteristics
Note: The above figures are initial values.
*1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON
sales representative for more detailed information on other operating environments.
*2. Weather-proof models is 50 mΩ or less (default value, built-in switch only).
*3. Except Switches with Flexible Rod Actuators.
*4. 500,000 operations min. for Weather-resistant models.
*5. For low-temperature models this is -40°C to +40°C (with no icing). For heat-resistant models the range is +5°C to 120°C.
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WL)
Permissible operating
frequency
Mechanical 120 operations/minute
Electrical 30 operations/minute
Permissible operating speed 1 mm/s to 1 m/s (in case of WLCA2-N)
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ or less (default value, built-in switch only) *2
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude *3
Shock Destruction 1,000 m/s2 max.
Malfunction 300m/s2 max. *3
Durability *1 Mechanical 15,000,000 operations min. 10,000,000 operations min. *4
Electrical 750,000 operations min. (3 A at 250 VAC, resistive load) 500,000 operations min. (3 A at 250 VAC, resistive load)
Ambient operating temperature -10 to +80°C (with no icing) *5
Ambient operating humidity 35 to 95%RH
Degree of protection IP67
Weight Approx. 250 g (for WLCL-TH-N) Approx. 250 g (for WLCL-TH-N)
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WL)
Wiring Specifications Screw terminals
Direct-wire connector and
Pre-wired Connector
Models
Screw terminals
Direct-wire connector and
Pre-wired Connector
Models
Dielectric
strength
Between terminals
of the same polarity 1,000 VAC, 50/60 Hz for 1 min 600 VAC, 50/60 Hz for 1 min 600 VAC, 50/60 Hz for 1 min 600 VAC, 50/60 Hz for 1 min
Between
currentcarrying
metal part and
ground
2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Between each
terminal and non-
current-carrying
metal part
2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
WL-N/WL
42
Circuit Configuration/Terminal Connection Diagram
*Light-ON when not operating means the operation indicator is lit when the actuator is free and is not lit when the actuator rotates or is pushed
down, and the Switch contacts contact to NO.
The above shows details of the switch interior. External wires (external resistances) are not shown. For details, refer to Operation on page 18.
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
Connector Pin Layout Diagram
* The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.
Operating characteristics type Basic models (WL-N)
Wiring Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Without operation indicator
Operation indicator
(Light-ON when Not Operating *)
Operating characteristics type High-sensitivity and High-precision models (WL)
Wiring Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Without operation indicator
Operation indicator
(Light-ON when Not Operating *)
13(NO)
12(NC)
14(NO)
11(NC)
Za
NONCNCNO
4--- --- 3
4
2 core
1 2 3
NONCNCNO
4--- --- 3
4 --- --- 1
3--- ---2
4 1 2 3
AC DC
Za Za
4 core 2 core
4 core
indicate the connector
pin number.
1 2 3 4
1 2 3 4
indicate the connector
pin number.
13(NO)
12(NC)
14(NO)
11(NC)
Internal
circuits
Za
NONCNCNO NONCNCNO
AC DC
Za Za
4 --- --- 3
4
2 core
1 2 3
4 --- --- 3
4 --- --- 1
3--- ---2
4
2 core
4 core
1 2 3
4 core
Internal
circuits
Internal
circuits
12 3 4
indicate the connector
pin number.
1 2 3 4
indicate the connector
pin number.
13(NO)
12(NC)
14(NO)
11(NC)
Za
NONCNCNO
4--- --- 3
4 1 2 3
NONCNCNO
4--- ---
--- ---
3
3
4
4
1
3 2
2
4 1 2 3
Za Za
DC
2 core
4 core
indicate the connector
pin number.
1 2 3 4
1 2 3 4
indicate the connector
pin number.
2 core
4 core
3 core
--- ---
---
AC
13(NO)
12(NC)
14(NO)
11(NC)
Za
Internal
circuits
1 2 3 4
indicate the connector
pin number.
NONCNCNO NONCNCNO
AC DC
Za Za
4 3
4 1 2 3
4--- 3
3
4
4
1
3 2
2
4 1 2 3
Internal
circuits
Internal
circuits
12 3 4 indicate the connector
pin number.
2 core
4 core 2 core
3 core
4 core
---
--- ---
---
---
---
--- ---
3
4
1
2
13
2
4
AC DC
Positioning piece * Positioning piece *
WL-N/WL
43
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
Structure and Nomenclature
Mold Specifications
Prevent entry of foreign objects from
conduit
Prevent entry of foreign objects from
conduit cover
Prevent entry of foreign objects from
head and conduit cover
WL@-139-N WL@-140-N WL@-141-N
WLG@-139 WLG@-140 WLG@-141
Prevent entry of metal powder from
head and conduit
Prevent entry of metal powder from
conduit cover
Prevent entry of metal powder from
head and conduit cover
WL@-145-N WL@-RP40-N WL@-RP60-N *1
WLG@-145 WLG@-RP40 WLG@-RP60 *1
Model Cable specifications Connector specifications
WL@-139-N
WLG@-139
Standard 5-m VCT cable. Finished outer diameter:
11.5 mm, 4 conductors. Resin cap
*1. Fluorine rubber is used for all rubber parts.
*2. The connector can be removed, so it is
possible to use flexible conduit for the cable.
WL@-140-N
WLG@-140
WL@-141-N
WLG@-141
WL@-145-N
WLG@-145
Standard 5-m VCT cable, with high flexibility and good
anti-oil properties attached. Finished outer diameter:
11.5 mm, 4 conductors.
Metal connector
WL@-RP40-N
WLG@-RP40 Resin connector *2
WL@-RP60-N
WLG@-RP60 Resin cap
: Molded parts
Standard
built-in switch Airtight
built-in switch
Airtight
built-in switch
Oil seal
Head cap
Standard
built-in switch
Airtight
built-in switch
Airtight
built-in
switch
Oil seal for
protection
against
cutting powder
X-ring
Airtight
built-in switch
Oil seal
Head cap
Airtight
built-in switch
Airtight
built-in switch
Oil seal for
protection against
cutting powder
X-ring
Airtight
built-in
switch
O-ring Airtight
built-in
switch
Airtight
built-in
switch
WL-N/WL
44
Dimensions (Unit: mm)
Roller Lever
Screw terminals
Operating characteristics
Model
WLCA2-TH-N
WLCA2-TC-N
WLCA2-RP-N
WLCA2-P1-N
WLCA2-2TH-N
WLCA2-2TC-N
WLCA2-2NTH-N
WLCA2-2NTC-N
WLG2-TH
WLG2-TC
WLG2-RP
WLG2-P1
WLGCA2-TH
WLGCA2-TC
WLGCA2-RP
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
9.81 N
0.98 N
10°
65°
13.34 N
1.47 N
40°
17.5×7 dia. *
(125)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R38
Four, 5.2 dia. holes
2-M3.5
Three, M4
* Stainless sintered roller
5
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
M5
Allen-head bolt
JIS B 0202 G1/2
68.7
21.6
53.2±0.8
42 max.
29.2±1.2
Four, M6
Depth: 15 min.
25.4
25.4
13.1
Roller lever R38
Heat-resistant type
WLCA2-TH-N
WLCA2-2TH-N
WLCA2-2NTH-N
Cold-resistant type
WLCA2-TC-N
WLCA2-2TC-N
WLCA2-2NTC-N
Weather-resistant type
WLCA2-P1-N
Corrosion-resistant type
WLCA2-RP-N
Note: The body color is yellow.
Note: The photo shows the WLCA2-TH-N model.
Three, M4
* Stainless sintered roller
Four, 5.2 dia.
holes
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
(125)
R38
4-M3.5
17.5×7 dia. *
M5
Allen-head bolt
JIS B0202 G1/2
Four, M6
Depth: 15 min.
60 max.
25.4
68.7
12.7
25.4
13.1
40
±1.5
41.5
±1.5
53±1.5
42 max.
53.2±0.8
29.2
21.6
±1.2
Roller lever R38
Heat-resistant type
WLG2-TH
WLGCA2-TH
Cold-resistant type
WLG2-TC
WLGCA2-TC
Corrosion-resistant type
WLG2-RP
WLGCA2-RP
Weather-resistant type
WLG2-P1
Note: 1. The body color is yellow.
2. The photo shows the WLGCA2-RP model.
+2°
-1°
+2°
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
45
Direct-wire cable
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLCA2-RP60-N
WLCA2-2RP60-N
WLCA2-139-N
WLCA2-2139-N
WLCA2-2N139-N
WLCA2-140-N
WLCA2-141-N
WLG2-RP60
WLG2-139
WLG2-140LD2
WLG2-140LD3
WLG2-141LD2
WLG2-141LD3
WLCA2-2N140-N WLGCA2-141LD3
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
13.34 N
1.18 N
20° max.
70°
10°
13.34 N
1.47 N
40°
17.5×7 dia. *
(125)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R38
Four, 5.2 dia. holes
2-M3.5
Three, M4
5
M5
Allen-head bolt
60 max.
12.7
41.5±1.5
40±1.5
25.4
53±1.5
13.1
68.7
21.6
53.2±0.8
42 max.
29.2±1.2
25.4
Vinyl cabtire cable (VCT
JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
* Stainless sintered roller
Four, M6
Depth: 15 min.
Roller lever R38
Coolant-resistant type
WLCA2-RP60-N
WLCA2-2RP60-N
Molded terminal-139
WLCA2-139-N
WLCA2-2139-N
WLCA2-2N139-N
Note: The photo shows the WLCA2-139-N model.
17.5×7 dia. *
(125)
(4.9) (15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R38
5
Vinyl cabtire cable (VCT
JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
* Stainless sintered roller
Four, 5.2 dia. holes
4-M3.5
Three, M4
M5
Allen-head bolt
60 max.
12.7
41.5±1.5
40±1.5
25.4
53±1.5
13.1
68.7
53.2±0.8
42 max.
29.2±1.2
25.4
Four, M6
Depth: 15 min.
21.6
Roller lever R38
Coolant-resistant type
WLG2-RP60
Molded terminal -139
WLG2-139
60 max.
12.7
40
±1.5
41.5
±1.5
53
±1.5
25.4
13.1
68.7
Four, M6
Depth: 15 min.
25.4
21.6
53.2
±0.8
42 max.
29.2
±1.2
Four, 5.2 dia. holes
Three, M4
M5
Allen-head bolt
17.5×7 dia. *
(125)
(20)
58.7
±0.2
14.7
R38
5
(4.9) (15.1)
40
±0.7
30.2
±0.2
* Stainless sintered roller
2-M3.5
SC-3M
Vinyl cabtire cable (VCT
JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
Roller lever R38
Molded terminal-140
WLCA2-140-N
WLCA2-2N140-N
Molded terminal-141
WLCA2-141-N
Note: The photo shows the WLCA2-141-N model.
60 max.
12.7
40
±1.5
41.5
±1.5
53
±1.5
25.4
13.1
68.7
Four, M6
Depth: 15 min.
25.4
21.6
42 max.
53.2
±0.8
29.2
±1.2
Four, 5.2 dia. holes
Three, M4
M5
Allen-head bolt
17.5×7 dia. *
(125)
58.7
±0.2
14.7
R38
5
(4.9) (15.1)
40
±0.7
30.2
±0.2
* Stainless sintered roller
4-M3.5
Vinyl cabtire cable (VCT
JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
SC-1M
Roller lever R38 With operation indicator
Molded terminal -140
WLG2-140LD2
WLG2-140LD3
Molded terminal -141
WLG2-141LD2
WLG2-141LD3
WLGCA2-141LD3
+2°
-1°
+2°
WL-N/WL
46
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLCA2-141LD2-N
WLCA2-141LD3-N
WLCA2-139LD2-N
WLCA2-139LD3-N
WLG2-139
WLG2-140
WLG2-141
WLG2-RP60LD2
WLG2-RP60LD3
WLG2-139LD3
WLCA2-RP60LD2-N
WLCA2-RP60LD3-N
WLCA2-2RP60LD2-N
WLCA2-2RP60LD3-N
WLCA2-2139LD2-N
WLCA2-2139LD3-N
WLGCA2-RP60LD2
WLGCA2-RP60LD3
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.47 N
40°
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
25.4
13.1
68.7
Four, M6
Depth: 15 min.
25.4
21.6
53.2±0.8
42 max.
29.2±1.2
Four,
5.2 dia. holes
Three, M4
SC-3M
M5
Allen-head bolt
17.5×7 dia. *
(125)
58.7±0.2
14.7
R38
5
(4.9) (15.1)
40±0.7
30.2±0.2
* Stainless sintered roller
2-M3.5
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50), 4 cores
Strip length: 5 mm
(20)
Roller lever R38 With operation indicator
Molded terminal -141
WLCA2-141LD2-N
WLCA2-141LD3-N
Note: The photo shows the WLCA2-141LD2-N model.
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
25.4
13.1
68.7
Four, M6
Depth: 15 min.
25.4
21.6
53.2±0.8
42 max.
29.2±1.2
Four, 5.2 dia. holes
Three, M4
SC-1M
M5
Allen-head bolt
17.5×7 dia. *
(125)
58.7±0.2
14.7
R38
5
(4.9) (15.1)
40±0.7
30.2±0.2
* Stainless sintered roller
4-M3.5
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50), 4 cores
Strip length: 5 mm
Roller lever R38
Molded terminal -140
WLG2-140
Molded terminal -141
WLG2-141
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50), 4 cores
Strip length: 5 mm
17.5×7 dia. *
(125)
(4.9)
(15.1)
40±0.7
30.2±0.2
58.7±0.2
14.7
R38
Four, 5.2 dia. holes
2-M3.5
Three, M4
* Stainless sintered roller
5
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
M5
Allen-head bolt
68.7
21.6
53.2±0.8
42 max.
29.2±1.2
Four, M6
Depth: 15
25.4
25.4
13.1
Roller lever R38 With operation indicator
Coolant-resistant specifications
WLCA2-RP60LD2-N
WLCA2-RP60LD3-N
WLCA2-2RP60LD2-N
WLCA2-2RP60LD3-N
Molded terminal -139
WLCA2-139LD2-N
WLCA2-139LD3-N
WLCA2-2139LD2-N
WLCA2-2139LD3-N
Note: The photo shows the WLCA2-RP60LD3-N model.
M5
Allen-head bolt
Three, M4
Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2 dia.
holes
60 max.
25.4
68.7
12.7
25.4
13.1
40
±1.5
41.5
±1.5
53±1.5
14.7
(125)
30.2
±0.2
40±0.7
(4.9)
(15.1)
58.7±0.2
5
R38
4-M3.5
17.5×7 dia. *
42 max.
53.2±0.8
29.2±1.2
21.6
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50), 4 cores
Strip length: 5 mm
Roller lever R38 With operation indicator
Coolant-resistant specifications
WLG2-RP60LD2
WLG2-RP60LD3
WLGCA2-RP60LD2
WLGCA2-RP60LD3
Molded terminal -139
WLG2-139LD3
+2°
-1°
+2°
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
47
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Note: The operating characteristics are measured at the lever length of 38 mm.
Model
WLCA12-TH-N
WLCA12-TC-N
WLCA12-P1-N
WLCA12-RP-N
WLCA12-2TH-N
WLCA12-2TC-N
WLCA12-2NTH-N
WLCA12-2NTC-N
WLG12-TH
WLG12-TC
WLG12-P1
WLG12-RP
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
13.34 N
1.18 N
25±5°
60°
16°
13.34 N
1.18 N
20° max.
70°
10°
9.81 N
0.98 N
10°
65°
17.5×7 dia. *
(4.9) (15.1)
40±0.7
30.2±0.2
58.7
±0.2
14.7
2-M3.5
Three, M4
Four, 5.2 dia.
holes
* Stainless sintered roller
5
Adjustable
range:
25 to 89
67 max.
12.7
41.5±1.5
60±1.5
M5
Allen-head
bolt
JIS B 0202 G1
/
2
68.7
65.2±0.8
42 max.
21.6
29.2±1.2
Four, M6
Depth: 15 min.
25.4
25.4
13.1
Adjustable Roller Lever (R25 to 89 mm)
Heat-resistant type
WLCA12-TH-N
WLCA12-2TH-N
WLCA12-2NTH-N
Cold-resistant type
WLCA12-TC-N
WLCA12-2TC-N
WLCA12-2NTC-N
Weather-resistant type
WLCA12-P1-N
Corrosion-resistant type
WLCA12-RP-N
Note: The photo shows the WLCA12-TH-N model.
Three, M4
* Stainless sintered roller
Four, 5.2 dia.
holes
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
(125)
R38
4-M3.5
17.5×7 dia. *
M5
Allen-head bolt
JIS B0202 G1/2
Four, M6
Depth: 15 min.
60 max.
25.4
68.7
12.7
25.4
13.1
40
±1.5
41.5
±1.5
53±1.5
42 max.
53.2±0.8
29.2
21.6
±1.2
Adjustable Roller Lever (R25 to 89 mm)
Heat-resistant type
WLG12-TH
Cold-resistant type
WLG12-TC
Weather-resistant type
WLG12-P1
Corrosion-resistant type
WLG12-RP
+2°
-1°
WL-N/WL
48
Direct-wire cable
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Note: The operating characteristics are measured at the lever length of 38 mm.
Model
WLCA12-RP60-N
WLCA12-139-N
WLCA12-140-N
WLCA12-141-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
min.
max.
13.34 N
1.18 N
15±5°
70°
12°
17.5×7 dia. *
(4.9)
(15.1)
40
±0.7
30.2
±0.2
58.7
±0.2
14.7
2-M3.5
Three, M4
Four, 5.2 dia.
holes
* Stainless sintered roller
5
Adjustable range:
25 to 89
67 max.
12.7
41.5
±1.5
60
±1.5
M5
Allen-head
bolt
68.7
65.2
±0.8
42 max.
21.6
29.2±1.2
Four, M6
Depth: 15 min.
25.4
25.4
13.1
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
Adjustable Roller Lever (R25 to 89 mm)
Coolant-resistant specifications
WLCA12-RP60-N
Molded terminal -139
WLCA12-139-N
17.5×7 dia. *
Adjustable range:
25 to 89
58.7±0.2
14.7
5
(4.9)
(15.1)
* Stainless sintered roller
40±0.7
30.2±0.2
Three, M4
Four, 5.2 dia.
holes
M5
Allen-head
bolt
2-M3.5
68.7
Four, M6
Depth: 15 min.
25.4
12.7
41.5±1.5
60±1.5
25.4
13.1
67 max.
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm2 (0.18/50),
4 cores
Strip length: 5 mm
SC-3M
65.2±0.8
42 max.
21.6
29.2
±1.2
Adjustable Roller Lever (R25 to 89 mm)
Molded terminal -140
WLCA12-140-N
Molded terminal -141
WLCA12-141-N
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
49
Plunger Actuators
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLD28-TH-N
WLD28-TC-N
WLD28-RP-N
WLD2-TH-N
WLSD-TH-N
WLSD-TC-N
WLSD-RP-N
WLSD2-TH-N
WLSD2-TC-N
WLSD2-RP-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
26.67 N
8.92 N
1.7 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
Operating position
Total travel position
OP
TTP max.
44±0.8 mm
39.5 mm
44±0.8 mm
39.5 mm
40.6±0.8 mm
---
54.2±0.8 mm
---
PT
Three, M4
Four, 5.2 dia.
holes
2-M3.5
30.2±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP
13.1
12.9
21.6
Four, M6
Depth: 15 min.
29.2±1.2
42 max.
68.7
* Stainless sintered roller
14.3×5 dia. *
JIS B0202 G1/2
Sealed top-roller plunger
Heat-resistant specifications
WLD28-TH-N
Cold-resistant specifications
WLD28-TC-N
Corrosion-resistant specifications
WLD28-RP-N
Note: The photo shows the WLD28-TH-N model.
Four, 5.2 dia.
holes
17×4.6 dia.
*
PT
30.2±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP 4-M3.5
Three, M4
13.1
12.9
21.6
29.2±1.2
42 max.
68.7
28.4
Four, M6
Depth: 15 min.
* Stainless sintered roller JIS B0202 G1/2
Top-roller plunger
Heat-resistant specifications
WLD2-TH-N
Three, M4
Four, 5.2 dia.
holes
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.7
21.6
JIS B0202 G
½
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
27.5
46.6±0.8
OP
PT
*1
.
Stainless steel plunger
*2. Cosmetic nuts
25 dia. *2
Two, M3.5
17.8
(96.2)
25.4
R1
9.3 dia. *1
Horizontal plunger
Heat-resistant specifications
WLSD-TH-N
Cold-resistant specifications
WLSD-TC-N
Corrosion-resistant specifications
WLSD-RP-N
Note: The photo shows the WLSD-TH-N model.
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.7
21.6 Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
55.7±0.8
*1. Stainless sintered roller
*2. Cosmetic nuts
25 dia. *2
2-M3.5
17.8
(96.2)
25.4
PT OP
17×4.6 dia. *1
27.5
JIS B0202 G1/2
Note: The photo shows the WLSD2-TH-N model.
Horizontal-roller plunger
Heat-resistant specifications
WLSD2-TH-N
Cold-resistant specifications
WLSD2-TC-N
Corrosion-resistant specifications
WLSD2-RP-N
WL-N/WL
50
Direct-wire cable
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLD28-RP60-N
WLD28-139-N
WLD28-140-N
WLD2-RP60-N WLSD-139-N
WLSD2-RP60-N
WLSD2-139-N
WLSD2-140-N
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
26.67 N
8.92 N
1.7 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1mm
Operating position
Total travel position
OP
TTP max.
44±0.8 mm
39.5 mm
44±0.8 mm
39.5 mm
40.6±0.8 mm
---
54.2±0.8 mm
---
PT
(4.9)
5
58.7±0.2
OP
Three, M4
30.2±0.2
40±0.7
(15.1)
* Stainless sintered roller
Four, 5.2 dia.
holes
2-M3.5
14.3×5 dia. *
13.1
12.9
21.6
29.2
±1.2
42 max.
68.7
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
Four, M6
Depth: 15 min.
Sealed top-roller plunger
Coolant-resistant specifications
WLD28-RP60-N
Molded terminal -139
WLD28-139-N
Note: The photo shows the WLD28-139-N model.
PT
Three, M4
Four, 5.2 dia.
holes
2-M3.5
30.2±0.2
40±0.7
(4.9)
5
(20)
58.7±0.2
(15.1)
OP
13.1
12.9
21.6
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
* Stainless sintered roller
14.3×5 dia. *
SC-3M
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
Sealed top-roller plunger
Molded terminal -140
WLD28-140-N
Four, 5.2 dia.
holes
17×4.6 dia.
*
PT
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
OP 4-M3.5
Three, M4
13.1
12.9
21.6
29.2
±1.2
42 max.
68.7
28.4
Four, M6
Depth: 15 min.
* Stainless sintered roller
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
Top-roller plunger
Coolant-resistant specifications
WLD2-RP60-N
Three, M4
Four, 5.2 dia.
holes
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.7
21.6
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
27.5
46.6±0.8
OP
PT
*1. Stainless sintered roller
*2. Cosmetic nuts
25 dia. *2
2-M3.5
17.8
(96.2)
25.4
9.3 dia. *1
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm2 (0.18/50),
4 cores
Strip length: 5 mm
Horizontal plunger
Molded terminal -139
WLSD-139-N
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.7
21.6
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
55.7±0.8
*1. Stainless sintered roller
*2. Cosmetic nuts
25 dia. *2
2-M3.5
17.8
(96.2)
25.4
PT OP
17×4.6 dia. *1
27.5
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm2 (0.18/50),
4 cores
Strip length: 5 mm
Horizontal-roller plunger
Coolant-resistant specifications
WLSD2-RP60-N
Molded terminal -139
WLSD2-139-N
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40±0.7
(4.9)
5
(20)
58.7
±0.2
(15.1)
13.1
12.7
21.6
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
55.7±0.8
*1. Stainless sintered roller
*2. Cosmetic nuts
25 dia. *2
Two, M3.5
17.8
(96.2)
25.4
PT OP
17×4.6 dia. *1
27.5
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
SC-3M
Horizontal-roller plunger
Molded terminal -140
WLSD2-140-N
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
51
Flexible Rod
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Note: These values are for the top end of the spring, rod, or wire.
Model
WLNJ-TH-N
WLNJ-TC-N
WLNJ-RP-N
WLNJ-2RP-N
Operating force
Pretravel
OF
PT
max. 1.47 N
20±10 mm
1.47 N
40±20 mm
Three, M4
Four, 5.2 dia.
holes
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
13.1
12.9
21.6 Four, M6
Depth: 15 min.
29.2
±1.2
42 dia.
68.7
Two, M3.5
*3
PT
*1
*2
(107)
33.7±0.8
140±2.5
6.5 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
JIS B0202
Coil spring
Heat-resistant specifications
WLNJ-TH-N
Cold-resistant specifications
WLNJ-TC-N
Corrosion-resistant
specifications
WLNJ-RP-N
Note: The photo shows
the WLNJ-TH-N
model.
26 dia.
Three, M4
Four, 5.2 dia.
holes
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
13.1
12.9
21.6 Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(95.4)
44.6
±0.8
140
±2.5
8 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
JIS B0202
Resin rod
Corrosion-resistant specifications
WLNJ-2RP-N
WL-N/WL
52
Direct-wire cable
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Note: These values are for the top end of the spring, rod, or wire.
Model
WLNJ-RP60-N
WLNJ-139-N
WLNJ-140-N
WLNJ-2RP60-N
WLNJ-2139-N
WLNJ-2140-N
Operating force
Pretravel
OF
PT
max. 1.47 N
20±10 mm
1.47 N
40±20 mm
Three, M4
Four, 5.2 dia.
holes
5
58.7
±0.2
13.1
12.9
21.6
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(107)
33.7
±0.8
140
±2.5
6.5 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
30.2
±0.2
40
±0.7
(15.1)
(4.9)
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
Coil spring
Coolant-resistant specifications
WLNJ-RP60-N
Molded terminal -139
WLNJ-139-N
Note: The photo shows
the WLNJ-RP60-N
model.
Three, M4
Four, 5.2 dia.
holes
5
58.7
±0.2
13.1
12.9
21.6
Four, M6
Depth: 15 min.
29.2
±1.2
42 max.
68.7
Two, M3.5
*3
PT
*1
*2
(107)
33.7
±0.8
140
±2.5
6.5 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
(20)
30.2
±0.2
40
±0.7
(15.1)
(4.9)
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm
2
(0.18/50),
4 cores
Strip length: 5 mm
SC-3M
Coil spring
Molded terminal -140
WLNJ-140-N
(4.9)
30.2
±0.2
Three, M4
Four, 5.2 dia.
holes
40
±0.7
5
(15.1)
13.1
12.9
Four, M6
Depth: 15 min.
Two, M3.5
26 dia.
*1 PT 8 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
58.7
±0.2
*3
68.7
42 max.
29.2
±1.2
21.6
*2
44.6
±0.8
140
±2.5
(95.4)
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm2 (0.18/50),
4 cores
Strip length: 5 mm
Resin rod
Coolant-resistant specifications
WLNJ-2RP60-N
Molded terminal -139
WLNJ-2139-N
Note: The photo shows
the WLNJ-2RP60-N
model.
Vinyl cabtire cable
(VCT JIS C 3312)
Nominal cross-section:
1.25 mm2 (0.18/50),
4 cores
Strip length: 5 mm
30.2
±0.2
Three, M4
SC-3M
Four, 5.2 dia.
holes
40±0.7
5
(15.1)
(20)
13.1
12.9
Four, M6
Depth: 15 min.
Two, M3.5
26 dia.
*1
*2 PT 8 dia.
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
58.7±0.2
*3
68.7
42 max.
29.2
±1.2
21.6
44.6
±0.8
140±2.5
(95.4)
(4.9)
Resin rod
Molded terminal -
140
WLNJ-2140-N
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
53
Spatter-prevention Switches
WL-N/WL
Uses stainless steel and plastic
materials that prevent the adhesion
of spatter, helping reduce problems
caused by zinc power generated
during welding.
Excellent Performance on Arc Welding Lines or Sites with
Spattering Cutting Powder
In addition to screw terminals types, Pre-wired connector
types are available.
Standard configuration includes operation indicators
•Includes baking finish for easy peeling of any spatter
adhering to lever
Stainless steel materials are used for the screws, rollers,
and other parts for reducing spatter adhesion during
welding process
Degree of Protection; IP67
Features
Structure designed for use in spattering environments from welding
(Typical model: WLCA2-LDS-N)
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on pages 81 to 86 and
Safety Precautions for All Limit Switches.
Screws
Externally visible screws on the head
and cover are made of stainless steel to
prevent spatter adherence.
Roller Lever Bolt
Stainless steel construction to
prevent spatter adherence.
Double nut models are also
available.
Head Cap
Using fluororesin prevents spatter from
adhering.
* Spatter means the zinc powder
produced when welding.
Adhering spatter to the Limit Switch
may cause malfunction of lever or
lamp cover.
The lack of gap prevents spatter
powder from clogging.
Using stainless steel prevents
spatter from adhering.
Roller, Roller Axis
A baking finish is applied to the
surface so that any adhering spatter
is easily removed.
Operating Lever
Actuator
Main unit
Head
WL-N/WL
54
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Basic models
(1) Actuator and Property Specifications
(2) Built-in Switch Specifications
(3) Indicator Specifications
* Cannot be combined with the pre-wired connector type.
(4) Lever Type *
* (5) Wiring Specifications Cannot be combined with pre-wired
connector type.
(5) Wiring Specifications
High-sensitivity and High-precision Models
(1) Actuator and Property Specifications
(2) Built-in Switch Specifications
(3) Indicator Specifications
* (5) Wiring Specifications Cannot be combined with pre-wired
connector type.
(4) Lever Type *
* (5) Wiring Specifications Cannot be combined with pre-wired
connector type.
(5) Wiring Specifications
WL@-@@@S@-N
(1) (2) (3) (4) (5)
Code Type Pretravel
(PT)
CA2 Roller lever Roller lever: R38 mm 15±5°
D28 Plunger
Actuators Sealed top-roller plunger 1.7 mm max.
Code Specifications
None Standard built-in switch
Code Specifications
LD LED (10 to 115 VAC/DC)
LE Neon lamp (125 to 250 VAC) *
Code Specifications Lever type
None Roller lever: R38 mm Allen-head lever
ARoller lever: R38 mm Double nut lever
Code Specifications Lever type
None
Screw terminals
(Conduit size:
G½)
--- --- --- ---
-M1J-1
Pre-wired
connectors
Threaded
(M12)
DC NO only NO:
-M1GJ-1 DC NO only NO:
-DGJS DC NC+NO NC:
NO:
-DTGJS
Smartclick
DC NC+NO NC:
NO:
3 4
1 4
1 2
3 4
1 2
3 4
WLG@-@@@S@
(1) (2) (3) (4) (5)
Code Type Pretravel
(PT)
2Roller lever Roller lever: R38 mm
High-sensitivity Models 10°
CA2 Roller lever Roller lever: R38 mm
High-precision Models
Code Specifications
None Standard built-in switch
55 Airtight built-in switch
Code Specifications
LD LED (10 to 115 VAC/DC)
LE Neon lamp (125 to 250 VAC) *
+2°
-1°
+2°
Code Specifications Lever type
None Roller lever: R38 mm Allen-head lever
ARoller lever: R38 mm Double nut lever
Code Terminal shape
Connector
shape
Voltage Wiring
locations
Connector
pin No.
None
Screw terminals
(Conduit size:
G½)
--- --- --- ---
-M1J-1
Pre-wired
connectors
Threaded
(M12)
DC NO only NO:
-M1GJ-1 DC NO only NO:
-DGJS03 DC NC+NO NC:
NO:
-M1TGJ
Smartclick
DC NO only NO:
-DTGJS03
DC NC+NO NC:
NO:
3 4
1 4
1 2
3 4
1 4
1 2
3 4
WL-N/WL
55
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
Ordering Information
Roller Lever
Standard built-in switch
Screw terminals
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
Pre-wired Connectors
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
Airtight Built-in Switch
Pre-wired Connector types
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
Appearance Actuator Pretravel (PT) Lever type
With operation indicator
Indicator *
LED Neon lamp
Wiring
Specifications
Model Model
Roller lever: R38 mm
15±5°
Double nut
Lever
NO wiring
WLCA2-LDAS-N WLCA2-LEAS-N
Allen-head
Lever WLCA2-LDS-N WLCA2-LES-N
10°
Double nut
Lever WLG2-LDAS WLG2-LEAS
Allen-head
Lever
WLG2-LDS WLG2-LES
WLGCA2-LDS WLGCA2-LES
Appearance Actuator Pretravel (PT) Lever type
Connector
shape
Usage
Voltage
Wiring
locations
Connector
pin No.
With operation indicator
LED
Indicator *
Wiring Specifications
Roller lever: R38 mm
15±5°
Allen-head
Lever
Threaded
(M12)
DC
NO only NO:
NO wiring
WLCA2-LDS-M1J-1-N
NC+NO
NO:
NC: WLCA2-LDS-DGJS-N
10°
NO:
NC: WLG2-LDS-DGJS03
NO only
NO:
NC: WLG2-LDS-DK1EJ03
NO: WLG2-LDS-M1J-1
NO: WLG2-LDS-M1GJ-1
NO: WLGCA2-LDS-M1J-1
NO: WLGCA2-LDS-M1GJ-1
15±5°
Smartclick
NC+NO NO:
NC: WLCA2-LDS-DTGJS-N
10° NO only NO: WLG2-LDS-DTGJS03
Appearance Actuator Pretravel (PT) Lever type
Connector
shape
Usage
Voltage
Wiring
locations
Connector
pin No.
With operation indicator
Indicator *
LED
Wiring
Specifications
Model
Roller lever: R38 mm 10° Allen-head
Lever
Threaded
(M12) DC
NO only NO:
NO wiring
WLG2-55LDS-M1J-1
NO: WLG2-55LDS-M1GJ-1
NC+NO
NO:
NC: WLG2-55LDS-DGJS03
Smartclick
NO:
NC: WLG2-55LDS-M1TGJ
+2°
-1°
+2°
3 4
3 4
1 2
+2°
-1°
3 4
1 2
3 4
2
3 4
1 4
+2°
3 4
1 4
3 4
1 2
+2°
-1°
1 4
+2°
-1°
3 4
1 4
3 4
1 2
3 4
1 2
WL-N/WL
56
Plunger Actuators
Standard built-in switch
Screw terminals
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
Pre-wired Connectors
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring). (However, Three-core and Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
Note: The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths.
Appearance Actuator Pretravel (PT)
With operation indicator
Indicator * LED Neon lamp
Wiring
Specifications Model Model
Sealed top-roller plunger 1.7 mm max. NO wiring WLD28-LDS-N WLD28-LES-N
Appearance Actuator Pretravel (PT) Connector
shape Voltage Wiring
locations
Connector
pin No.
With operation indicator
Indicator * LED
Wiring
Specifications Model
Sealed top-roller plunger 1.7 mm max.
Threaded
(M12)
DC NO only NO: NO wiring WLD28-LDS-M1J-1-N
DC NO only NO: NO wiring WLD28-LDS-M1GJ-1-N
DC NC+NO NO:
NC: NO wiring WLD28-LDS-DGJS-N
Smartclick DC NC+NO NO:
NC: NO wiring WLD28-LDS-DTGJS-N
3 4
1 4
3 4
1 2
3 4
1 2
WL-N/WL
57
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
Specifications
Ratings
Screw terminals
With Operation Indicator
With Operation Indicators (Neon Lamps)
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Allowable Inrush Current/Minimum Applicable Load
Pre-wired connectors
Connector DC Specifications: With Operation Indicators (LEDs)
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Allowable Inrush Current/Minimum Applicable Load
Operation Indicator
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 115 10 3 1.5 5 --- 10 5 2.5 --- ---
DC
12 10 6 3 --- --- 10 6 --- ---
24 6 4 3 --- --- 6 4 --- ---
48 3 2 1.5 --- --- 3 0.2 --- ---
115 0.8 0.2 0.4 --- 0.8 0.1 --- ---
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 125 10 3 1.5 5 --- 10 5 2.5 --- ---
250 10 2 1 5 --- 10 3 1.5 --- ---
Operating
characteristics
type
Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Inrush
current
NC 30 A max. 15 A max.
NO 20 A max. 10 A max.
Minimum
applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
DC
12 3 3 --- --- 3 3 --- ---
24 3 3 --- --- 3 3 --- ---
48 4 2 1.5 --- --- 3 2 --- ---
115 0.8 0.2 0.2 0.4 --- 0.8 0.2 --- ---
Operating
characteristics
type
Basic models (WL-N) High-sensitivity and
High-precision Switches (WL)
Inrush
current
NC 3 A max.
NO 3 A max.
Minimum
applicable load 5 VDC 1 mA, resistive load, P level 5 VDC 1 mA, resistive load, P level
Operation
indicator type LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current
(Reference value)
Approx. 0.4 mA at 10 VAC/DC;
Approx. 0.5 mA at 115 VAC/DC
Approx. 0.6 mA at 125 VAC;
Approx. 1.9 mA at 250 VAC
WL-N/WL
58
Characteristics
Note: The above figures are initial values.
* The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON
sales representative for more detailed information on other operating environments.
*Excluding those with operation indicators.
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WL)
Permissible
operating
frequency
Mechanical 120 operations/minute
Electrical 30 operations/minute
Rated frequency 50/60 Hz
Permissible operating speed 1 mm/s to 1 m/s (for WLCA2-LDS-N)
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-in switch)
Vibration
resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Durability * Mechanical 15,000,000 operations min. 10,000,000 operations min.
Electrical 750,000 operations min. (3 A at 250 VAC, resistive load) 500,000 operations min. (3 A at 115 VAC, resistive load)
Ambient operating temperature -10 to +80°C (with no icing)
Ambient operating humidity 35 to 95%RH
Degree of protection IP67
Weight Approx. 255 g (in case of WLCA2-LDS-N) Approx. 270 g (in case of WLGCA2-LDS)
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision Switches (WL)
Wiring Specifications Screw terminals
Direct-wire connector and
Pre-wired Connector Mod-
els
Screw terminals
Direct-wire connector and
Pre-wired Connector Mod-
els
Dielectric
strength
Between terminals
of the same polarity
1,000 VAC, 50/60 Hz for 1 min *
600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min *
Between current carrying
metal part and ground
2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Between each terminal
and non-current carrying
metal part
2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
59
Terminal Connection Diagram
* Light-ON when not operating means the operation indicator is lit when the actuator is free and is not lit when the actuator rotates or is pushed
down, the Switch contacts contact NO.
The above shows details of the switch interior. External wires (external resistances) are not shown. For details, refer to Operation on page 18.
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
Connector Pin Layout Diagram
* The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.
Operating characteristics type Basic models (WL-N)
Wiring Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Without operation indicator
With Operation Indicator
(Light-ON When Not Operating *)
Operating characteristics type High-sensitivity and High-precision Switches (WL)
Wiring Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Without operation indicator
With Operation indicator
(Light-ON when Not Operating *)
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
NONCNCNO
4--- --- 3
4 --- --- 1
3--- ---2
4
2 core
4 core
1 2 3
Za
12 3 4 indicate the connector pin number.
DC
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
Internal circuits
NONCNCNO
Za
4 3
4 1
3 2
4 1 2 3
DC
--- ---
--- ---
--- ---
Internal circuits
2 core
4 core
1 2 3 4
indicate the connector pin number.
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
NONCNCNO
43
3
4
4
1
3 2
2
4 1 2 3
Za
--- ---
---
---
---
--- ---
DC
2 core
3 core
4 core
1 2 3 4indicate the connector pin number.
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
Internal circuits
NONCNCNO
Internal circuits
DC
Za
4 --- --- 3
3
4 ---
4---
--- 1
3--- ---2
2
4
2 core
4 core
3 core
1 2 3
1 2 3 4 indicate the connector pin number.
3
4
1
2
13
2
4
AC DC
Positioning piece * Positioning piece *
WL-N/WL
60
Structure and Nomenclature
Spatter-prevention Models (WLCA2-LES-N)
Screws
Externally visible screws on the head
and cover are made of stainless steel to
prevent spatter adherence.
Roller Lever Bolt
Stainless steel construction to
prevent spatter adherence.
Double nut models are also
available.
Head Cap
Using fluororesin prevents spatter from
adhering.
* Spatter means the zinc powder
produced when welding.
Adhering spatter to the Limit Switch
may cause malfunction of lever or
lamp cover.
The lack of gap prevents spatter
powder from clogging.
Using stainless steel prevents
spatter from adhering.
Roller, Roller Axis
A baking finish is applied to the
surface so that any adhering spatter
is easily removed.
Operating Lever
Actuator
Main unit
Head
WL-N/WL
61
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
Dimensions (Unit: mm)
Roller Lever
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLCA2-LDAS-N
WLCA2-LEAS-N
WLCA2-LDS-N
WLCA2-LES-N
WLG2-LDAS
WLG2-LDS
WLG2-LEAS
WLG2-LES
WLGCA2-LDS
WLGCA2-LES
Operating force OF max.
Release force RF min.
Pretravel PT
Overtravel OT min.
Movement Differential
MD max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
13.34 N
1.47 N
40°
(125)
(4.9) (15.1)
40±0.7
30.2±0.2
R38
58.7±0.2
14.7
5
Two, M5 Allen-head
nut and arm
set screw
68.7
21.6
53.2±0.8
25.4
12.7
40±1.5
41.5±1.5
53±1.5
25.4
13.1
29.2
±1.2
17.5×7 dia. *
Two, M3.5
Three, M4
Four, 5.2 dia. holes
* Stainless sintered roller
Fluorine
resin cap
JIS B 0202 G½
42 max.
Four, M6
Depth: 15 min.
60 max.
Roller lever R38
Double nut lever
With operation indicator (LED)
WLCA2-LDAS-N
With operation indicator (neon lamp)
WLCA2-LEAS-N
Note: The photo shows the WLCA2-LDAS-N model.
Three, M4
Four, M6
Depth: 15 min.
* Stainless steel roller
60 max.
25.4
68.7
12.7
25.4
13.1
53±1.5
41.5±1.5
40±1.5
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
(125)
R38
Four, M3.5
17.5×7 dia. *
42 max.
53.2±0.8
29.2
21.6
±1.2
Fluorine resin cap
Four, 5.2 dia.
holes
JIS B 0202 G½
Two, M5 Allen-head
nut and arm
set screw
Roller lever R38
Double nut lever
With operation indicator (LED)
WLG2-LDAS
With operation indicator (neon lamp)
WLG2-LEAS
17.5×7 dia. *
(125)
(4.9) (15.1)
40±0.7
30.2±0.2
R38
Two, M3.5
Three, M4
Four, 5.2 dia. holes
* Stainless sintered roller
58.7±0.2
14.7
5
M5
Allen-head bolt
Fluorine
resin cap
JIS B 0202 G½
68.7
21.6
53.2±0.8
42 max.
29.2±1.2
Four, M6
Depth: 15 min.
25.4
60 max.
12.7
40±1.5
41.5±1.5
53±1.5
25.4
13.1
Roller lever R38
Allen-head lever
With operation indicator (LED)
WLCA2-LDS-N
With operation indicator (neon lamp)
WLCA2-LES-N
Note: The photo shows the WLCA2-LDS-N model.
Three, M4
Four, M6
Depth: 15 min.
* Stainless steel roller
60 max.
25.4
68.7
12.7
25.4
13.1
53±1.5
41.5
±1.5
40±1.5
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
(125)
R38
Four, M3.5
17.5×7 dia. *
42 max.
35
29.2
21.6
±1.2
Fluorine resin cap
Four, 5.2 dia.
holes
JIS B 0202 G½
M5
Allen-head bolt
Roller lever R38
Allen-head lever
With operation indicator (LED)
WLG2-LDS
WLGCA2-LDS
With operation indicator (neon lamp)
WLG2-LES
WLGCA2-LES
+2°
-1°
+2°
WL-N/WL
62
Pre-wired connector (threaded) Pre-wired connector type (Smartclick)
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLCA2-LDS-M1J-1-N
WLCA2-LDS-DGJS-N
WLCA2-LDS-DTGJS-N
WLG2-LDS-DGJS03
WLG2-LDS-DK1EJ03
WLG2-55LDS-M1J-1
WLG2-55LDS-M1GJ-1
WLG2-55LDS-DGJS03
WLG2-LDS-M1J-1
WLG2-LDS-M1GJ-1
WLG2-LDS-DTGJS03
WLG2-55LDS-M1TGJ
WLGCA2-LDS-M1J-1
WLGCA2-LDS-M1GJ-1
Operating force OF max.
Release force RF min.
Pretravel PT
Overtravel OT min.
Movement Differential
MD max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
13.34 N
1.47 N
40°
R38
Four, M6
Depth: 15 min.
40±0.7
30.2±0.2
* Stainless sintered roller
53.2±0.8
42 max.
68.7
25.4
60 max.
41.5±1.5
40±1.5
300
53±1.5
25.4
13.1
12.7
17.5×7 dia. *
SC-1M
(125)
(4.9)
(15.1)
58.7±0.2
14.7
Two, M3.5
M5
Allen-head
bolt
Three, M4
Four, 5.2 dia. holes
5
XS2H-D421
+100
-50
29.2±1.2
Fluorine
resin cap
Roller lever R38
Allen-head lever
With operation indicator (LED)
WLCA2-LDS-M1J-1-N
WLCA2-LDS-DGJS-N
Note: The photo shows the
WLCA2-LDS-M1J-1-N
model.
R38
Four, M6
Depth: 15 min.
40±0.7
30.2±0.2
* Stainless sintered roller
53.2±0.8
42 max.
68.7
25.4
60 max.
41.5±1.5
40±1.5
300
53±1.5
25.4
13.1
12.7
17.5×7 dia. *
SC-1M
(125)
(4.9)
(15.1)
58.7
±0.2
14.7
Two, M3.5
M5
Allen-head
bolt
Three, M4
Four, 5.2 dia. holes
5
XS5H-D421
+100
-50
29.2±1.2
Fluorine
resin cap
Roller lever R38
Allen-head lever
With operation indicator (LED)
WLCA2-LDS-DTGJS-N
M5
Allen-head bolt
Three, M4
Four, M6
Depth: 15 min.
* Stainless steel roller
Four, 5.2 dia. holes
60 max.
25.4
68.7
12.7
25.4
13.1
40±1.5
41.5
±1.5
53±1.5
30.2±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
(125)
14.7
5
R38
Four, M3.5
17.5×7 dia. *
42 max.
53.2±0.8
35
29.2
21.6
±1.2
XS2H-D421
SC-1M
Fluorine resin cap
SC-1M
300 +100
-50
Roller lever R38
Allen-head lever
Threaded (M12)
With operation indicator (LED)
WLG2-LDS-DGJS03
WLG2-LDS-DK1EJ03
WLG2-55LDS-M1J-1
WLG2-55LDS-M1GJ-1
WLG2-55LDS-DGJS03
WLG2-LDS-M1J-1
WLG2-LDS-M1GJ-1
WLGCA2-LDS-M1J-1
WLGCA2-LDS-M1GJ-1
M5
Allen-head bolt
Three, M4
Four, M6
Depth: 15 min.
* Stainless steel roller
Four, 5.2 dia. holes
60 max.
25.4
68.7
12.7
25.4
13.1
40±1.5
41.5±1.5
53±1.5
14.7
(125)
(4.9)
(15.1)
30.2±0.2
40±0.7
58.7
±0.2
300+100
-50
5
R38
Four, M3.5
17.5×7 dia. *
42 max.
53.2±0.8
29.2
21.6
±1.2
XS5H-D421
SC-1M
Fluorine
resin cap
Roller lever R38
Allen-head lever
Smartclick
With operation indicator (LED)
WLG2-LDS-DTGJS03
WLG2-55LDS-M1TGJ
+2°
-1°
+2°
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
63
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLD28-LDS-N
WLD28-LES-N
WLD28-LDS-M1J-1-N
WLD28-LDS-M1GJ-1-N
WLD28-LDS-DGJS-N
WLD28-LDS-DTGJS-N
Operating force OF max.
Release force RF min.
Pretravel PT max.
Overtravel OT min.
Movement Differential
MD max.
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
Operating Position
OP
Total travel Position
TTP max.
44. 5±0.8 mm
39.5 mm
PT
* Stainless sintered roller
14.3×5 dia. *
Two, M3.5
OP
42 max.
13.1
12.9
21.6
JIS B0202 G½
29.2±1.2
68.7
Rubber cap
(fluorine rubber)
Three, M4
Four, 5.2 dia. holes
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
Depth: 15 min.
Four, M6
Sealed top-roller plunger
With operation indicator
LED
WLD28-LDS-N
Neon lamp
WLD28-LES-N
Note: The photo shows the
WLD28-LDS-N model.
* Stainless sintered roller
42 max.
13.1
12.9
Depth: 15 min.
Four, M6
29.2±1.2
68.7
Rubber cap
(fluorine rubber)
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
Three, M4
XS2H-D421
14.3×5 dia. *
Two, M 3.5
Four, 5.2 dia. holes
SC-1M
-
50
+100
300
PT
OP
Sealed top-roller plunger
Threaded (M12)
WLD28-LDS-M1J-1-N
WLD28-LDS-M1GJ-1-N
WLD28-LDS-DGJS-N
Smartclick
WLD28-LDS-DTGJS-N
Note: The photo shows the
WLD28-LDS-M1J-1-N
model.
64
Long-life Switches
WL-N/WL
A mechanical durability of over 30
Million Operations
Long life has been achieved by increasing the resistance
to friction and creating better sliding properties in the
head mechanism
•Direct-wire Connector and Pre-wired Connector Models
in the lineup
Operation indicators (LED) installed in all the Long-life
Switches.
Features
Mechanical structure featuring mechanical durability of more than 30 million
operations (WLMCA2-N)
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on pages 81 to 86 and
Safety Precautions for All Limit Switches.
Head Cap
The head cap helps prevent the entry of cutting
chips.You can use the protrusion on the cap to
confirm the set position.
PEEK resin is used. It provides superior
resistance to wear. You can change the
mounting direction to use any one of the three
operating directions (both sides, left side, or
right side).
Operating Plunger
High sealing performance is achieved. The seal
also serves as a spacer.
There is no troublesome insulating paper,
making it easy to work with the Switch.
Cover Seal
Built-in Switch
Built-in switch with an
SPST-NO+NC contact form.
Terminal Screws
Four, M3.5 screws.
Conduit Opening
In addition to parallel threads for G½ tubing,
direct-wired and pre-wired connector types are available.
Cover Setscrew
You can remove the two screws to
mount the head in any of the four
possible directions.
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Actuator
Roller
The roller is made of self-lubricating sintered
stainless steel.
It provides superior resistance to wear.
Lever
The lever is forged from anti-corrosive
aluminum alloy. It provides superior corrosion
resistance and outstanding strength. With a
roller lever actuator, the actuator position can
be set anywhere within 360°. (The lever
cannot be mounted in the opposite direction.)
Cover
Shield Structure
A head cap and oil seal form a double-seal structure.
Excellent durability and reliability are ensured.
Oil seal
Head cap
Main unit
Head
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
65
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Basic models
(1) Actuator and Property Specifications
(2) Indicator Specifications
(3) Wiring Specifications
*1. Refer to Connector Pin Layout Diagram on pages 69 for details on
connector pin numbers.
*2. The standard cable length for a pre-wired connector is 0.3 m.
High-sensitivity and High-precision Switches
(1) Actuator and Property Specifications
(2) Indicator Specifications
(3) Wiring Specifications
*1. Refer to Connector Pin Layout Diagram on pages 69 for details on
connector pin numbers.
*2. The standard cable length for a pre-wired connector is 0.3 m.
WLM@-LD@-N
(1) (2) (3)
Code Type Pretravel (PT)
CA2 Roller lever Roller lever: R38 mm 15±5°
Code Specifications
LD LED (10 to 115 VAC/DC)
Code Terminal shape
Connector
shape Voltage
Wiring
locations
Connector
pin No. *1
None
Screw terminals
(Conduit size: G½)
--- --- --- ---
K13A
Direct-wire
connector
Threaded
(M12)
AC NO only NO:
K13 DC NO only NO:
K43A AC NC+NO NC:
NO:
K43 DC NC+NO NC:
NO:
-M1J
Pre-wired
connectors *2
Threaded
(M12)
DC NO only NO:
-AGJ AC NC+NO NC:
NO:
-DGJ DC NC+NO NC:
NO:
-DTGJ Smartclick DC NC+NO NC:
NO:
3 4
3 4
1 2
3 4
1 2
3 4
3 4
1 2
3 4
1 2
3 4
1 2
3 4
WLMG@-LD@
(1) (2) (3)
Code Type Pretravel (PT)
2Roller lever Roller lever: R38 mm
High-sensitivity Models 10°
CA2 Roller lever Roller lever: R38 mm
High-precision Models
Code Specifications
LD LED (10 to 115 VAC/DC)
+2°
-1°
+2°
Code Terminal shape
Connector
shape
Voltage
Wiring
locations
Connector
pin No. *1
None
Screw terminals
(Conduit size: G½)
--- --- --- ---
K13A
Direct-wire
connector
Threaded
(M12)
AC NO only NO:
K13 DC NO only NO:
K43A AC NC+NO NC:
NO:
K43 DC NC+NO NC:
NO:
-M1J
Pre-wired
connectors *2
Threaded
(M12)
DC NO only NO:
-DGJ03 DC NC+NO NC:
NO:
-DTGJ03 Smartclick DC NC+NO NC:
NO:
3 4
3 4
1 2
3 4
1 2
3 4
3 4
1 2
3 4
1 2
3 4
WL-N/WL
66
Ordering Information
Roller Lever
Screw terminals
Direct-wire connector
Pre-wired connectors
*1. The default setting is for light-ON when not operating. Turn the lamp holder by 180° to change the setting to light-ON when operating. (However,
Four-core Switches cannot be switched to light-ON when operating (NC wiring).
*2. The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths.
Appearance
Actuator Pretravel
(PT)
With operation indicator
Indicator *1 LED
Wiring
Specifications
Model
Roller lever: R38 mm
15±5°
NO wiring
WLMCA2-LD-N
10° WLMG2-LD
5° WLMGCA2-LD
Appearance
Actuator Pretravel
(PT) Voltage Wiring
locations Connector pin No.
With operation indicator
Indicator *1 LED
Wiring
Specifications
Model
Roller lever: R38 mm
15±5°
AC NO only NO:
NO wiring
WLMCA2-LDK13A-N
NC+NO NO: NC: WLMCA2-LDK43A-N
DC NO only NO: WLMCA2-LDK13-N
NC+NO NO: NC: WLMCA2-LDK43-N
10°
AC NO only NO: WLMG2-LDK13A
NC+NO NO: NC: WLMG2-LDK43A
DC NO only NO: WLMG2-LDK13
NC+NO NO: NC: WLMG2-LDK43
AC NO only NO: WLMGCA2-LDK13A
NC+NO NO: NC: WLMGCA2-LDK43A
DC NO only NO: WLMGCA2-LDK13
NC+NO NO: NC: WLMGCA2-LDK43
Appearance
Actuator Pretravel
(PT) Voltage Connector
shape
Wiring
locations
Connector
pin No.
With operation indicator
Indicator *1 LED
Wiring
Specifications
Model
Roller lever: R38 mm
15±5°
AC Threaded
(M12)
NO only NO:
NO wiring
WLMCA2-LD-M1J-N
NC+NO
NO:
NC: WLMCA2-LD-AGJ-N
DC
NO:
NC: WLMCA2-LD-DGJ-N
Smartclick NC+NO NO:
NC: WLMCA2-LD-DTGJ-N
10°
Threaded
(M12)
NO only NO: WLMG2-LD-M1J
NC+NO
NO:
NC: WLMG2-LD-DGJ03
Smartclick NO:
NC: WLMG2-LD-DTGJ03
Threaded
(M12) NO only NO: WLMGCA2-LD-M1J
Smartclick NC+NO NO:
NC: WLMGCA2-LD-DTGJ03
+2°
-1°
+2°
3 4
3 4
1 2
3 4
3 4
1 2
+2°
-1°
3 4
3 4
1 2
3 4
3 4
1 2
+2°
3 4
3 4
1 2
3 4
3 4
1 2
3 4
3 4
1 2
3 4
1 2
3 4
1 2
+2°
-1°
3 4
3 4
1 2
3 4
1 2
+2°
3 4
3 4
1 2
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
67
Specifications
Ratings
Screw terminals
With Operation Indicator
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Allowable Inrush Current/Minimum Applicable Load
Direct-wire connector and Pre-wired Connector Models Type
DC Connector: With Operation Indicators (LEDs)
AC Connector: With Operation Indicators (LEDs)
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Allowable Inrush Current/Minimum Applicable Load
Operation Indicator
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 115 10 3 1.5 5 --- 10 5 2.5 --- ---
DC
12 10 6 3 --- --- 10 6 --- ---
24 6 4 3 --- --- 6 4 --- ---
48 3 2 1.5 --- --- 3 0.2 --- ---
115 0.8 0.2 0.4 --- 0.8 0.1 --- ---
Operating
characteristics type Basic models (WL-N) High-sensitivity models (WL) High-precision models (WL)
Inrush
current
NC 30 A max. 15 A max. 15 A max.
NO 20 A max. 10 A max. 10 A max.
Minimum applicable
load
5 VDC 1 mA, resistive load,
P level
5 VDC 1 mA, resistive load,
P level
5 VDC 160 mA, resistive load,
N level reference value
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
DC
12 3 3 --- --- 3 3 --- ---
24 3 3 --- --- 3 3 --- ---
48 4 2 1.5 --- --- 3 2 --- ---
115 0.8 0.2 0.2 0.4 --- 0.8 0.2 --- ---
Ratings
Non-inductive load (A) Inductive load (A)
Basic models (WL-N) High-sensitivity and
High-precision models (WL) Basic models (WL-N) High-sensitivity and
High-precision models (WL)
Resistive load Lamp load Resistive load Lamp load Inductive load Motor load Inductive load Motor load
Voltage (V) NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO
AC 115 3 3 1.5 3 --- --- 3 3 2.5 --- --- ---
Operating
characteristics type Basic models (WL-N) High-sensitivity models (WL) High-precision models (WL)
Inrush
current
NC 3 A max.
NO 3 A max.
Minimum applicable
load
5 VDC 1 mA, resistive load,
P level
5 VDC 1 mA, resistive load,
P level
5 VDC 160 mA, resistive load,
N level, reference value
Operation indicator type
LED Neon lamp
Rated voltage 10 to 115 VAC/DC 125 to 250 VAC
Leakage current
(Reference value)
Approx. 0.4 mA at 10 VAC/DC;
Approx. 0.5 mA at 115 VAC/DC
Approx. 0.6 mA at 125 VAC;
Approx. 1.9 mA at 250 VAC
WL-N/WL
68
Characteristics
* The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON
sales representative for more detailed information on other operating environments.
Note: The above figures are initial values.
*Excluding those with operation indicators.
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision models (WL)
Permissible
operating
frequency
Mechanical 120 operations/minute
Electrical 30 operations/minute
Rated frequency 50/60 Hz
Permissible operating speed 1 mm/sec to 1 m/sec
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value for the built-in switch)
Vibration
resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Durability *
Mechanical 30,000,000 operations min.
Electrical 30,000,000 operations min. (10 mA at 24 VAC, resistive load)
750,000 operations min. (3 A at 115 VAC, resistive load) 500,000 operations min. (3 A at 115 VAC, resistive load)
Ambient operating temperature -10 to +80°C (with no icing)
Ambient operating humidity 35 to 95%RH
Degree of protection IP67
Weight Approx. 255 g (in case of WLMCA2-LD-N) Approx. 270 g (in case of WLMGCA2-LD)
Operating characteristics type Basic models (WL-N) High-sensitivity and High-precision Switches (WL)
Wiring Specifications Screw terminals
Direct-wire connector and
Pre-wired Connector Models
Screw terminals
Direct-wire connector and
Pre-wired Connector Models
Dielectric
strength
Between terminals
of the same polarity
1,000 VAC, 50/60 Hz for 1 min *
600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min * 600 VAC, 50/60 Hz for 1 min *
Between current-
carrying metal part
and ground
2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Between each
terminal and non-
current-carrying
metal part
2,200 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
69
Terminal Connection Diagram
* Light-ON when not operating means the operation indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close
when the actuator rotates or is pushed down. The above shows details of the switch interior. External wires (external resistances) are not shown.
For details, refer to Operation on pages 18.
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website.
Connector Pin Layout Diagram
* The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight
connector.
Operating
characteristics type
Basic models (WL-N)
Wiring
Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Operation indicator
(Light-ON when Not
Operating *)
Operating
characteristics type
High-sensitivity models (WL)
Wiring
Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Operation indicator
(Light-ON when Not
Operating *)
Operating
characteristics type
High-precision models (WL)
Wiring
Specifications Screw terminals Direct-wire connector and Pre-wired Connector Models
Operation indicator
(Light-ON when Not
Operating *)
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
Internal circuits
NONCNCNONONCNCNO
Za Za
4 3
4 1 2 3
4 3
4 1
3 2
4 1 2 3
AC DC
--- --- --- ---
--- ---
--- ---
Internal circuits Internal circuits
2 core
4 core 2 core
4 core
41 2 3 indicate the connector
pin number.
1 2 3 4 indicate the connector pin number.
13 (NO)
12 (NC)
14 (NO)
11 (NC)
Za
Internal circuits
NONCNCNONONCNCNO
Za Za
4 3
4 1 2 3
4 3
3
4
4
1
3 2
2
4 1 2 3
AC DC
--- --- --- ---
---
---
---
--- ---
Internal circuits Internal circuits
2 core
2 core
3 core
4 core
4 core
1 2 3 4 indicate the connector
pin number.
1 2 3 4 indicate the connector pin number.
3 (NO)
2 (NC)
4 (NO)
1 (NC)
Za
Internal circuits
NONCNCNONONCNCNO
Za Za
4 3
4 1 2 3
4 3
3
4
4
1
3 2
2
4 1 2 3
AC DC
--- --- --- ---
---
---
---
--- ---
Internal circuits Internal circuits
2 core
2 core
3 core
4 core
4 core
1 2 3 4 indicate the connector
pin number.
1 2 3 4 indicate the connector pin number.
13
2
4
AC
3
4
1
2
DC
Positioning
piece * Positioning piece *
WL-N/WL
70
Structure and Nomenclature
WLMCA2-N
Head Cap
The head cap helps prevent the entry of cutting
chips.You can use the protrusion on the cap to
confirm the set position.
PEEK resin is used. It provides superior
resistance to wear. You can change the
mounting direction to use any one of the three
operating directions (both sides, left side, or
right side).
Operating Plunger
High sealing performance is achieved. The seal
also serves as a spacer.
There is no troublesome insulating paper,
making it easy to work with the Switch.
Cover Seal
Built-in Switch
Built-in switch with an
SPST-NO+NC contact form.
Terminal Screws
Four, M3.5 screws.
Conduit Opening
In addition to parallel threads for G½ tubing,
direct-wired and pre-wired connector types are available.
Cover Setscrew
You can remove the two screws to
mount the head in any of the four
possible directions.
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Actuator
Roller
The roller is made of self-lubricating sintered
stainless steel.
It provides superior resistance to wear.
Lever
The lever is forged from anti-corrosive
aluminum alloy. It provides superior corrosion
resistance and outstanding strength. With a
roller lever actuator, the actuator position can
be set anywhere within 360°. (The lever
cannot be mounted in the opposite direction.)
Cover
Shield Structure
A head cap and oil seal form a double-seal structure.
Excellent durability and reliability are ensured.
Oil seal
Head cap
Main unit
Head
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
71
WLMGCA2
Set Position Marker Plate
The set position is easy to view.
The stroke is indicated in fluorescent color that
is visible from the slit in the rubber cap.
In addition to parallel threads for G½ tubing,
direct-wired and pre-wired connector types are
available.
Roller
The roller is made of self-lubricating stainless
sintered and boasts high resistance to wear.
Lever
The lever forged of anti-corrosive aluminium
alloy features high corrosion resistance and
outstanding ruggedness. With roller lever
models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
Cover Seal
By using a packing seal as the
cover seal, an optimum squeeze
can be obtained and high sealing
properties are assured as well.
Separator
The separator has outstanding
insulation properties and prevents
the generation of any gases which
may corrode the internal parts.
Cover Mounting Screw
A combination Phillips-slotted
screws are used to ensure ease
of use.
Terminal Screws
Cover
Four, M4 screws
Operational Plunger
Fluorescent paint
Requires maintenance (excessive overtravel)
Requires maintenance (excessive overtravel)
Requires maintenance (insufficient overtravel)
Proper range
Proper range
Actuator
Head
The Head can be mounted in any of the
four directions by removing the screws
at the four corners of the Head.
Release Plunger
Hardening method changed for greater
abrasion resistance.
Shaft Section Seal
By fitting a double seal consisting of
an oil seal and an X-ring to the
rotary shaft, even greater sealing
properties are achieved.
Smoother Movement
A grease holder is provided on the shaft
to prevent the grease from running out.
Smooth movement is achieved using
olefin grease. (Standard models use
molybdenum disulfide grease.)
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Bearing
The bearing smooths the plunger
movement.
X-ring
Oil seal
Grease holder
Long-life Model
Standard Model
Long-life Model
Standard Model
Sintered
alloy
Stainless
steel +
Hardening
Head
Mounting
Screws
Conduit Opening
WL-N/WL
72
Dimensions (Unit: mm)
Roller Lever
Screw terminals
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model WLMCA2-LD-N WLMG2-LD WLMGCA2-LD
Operating force OF max.
Release force RF min.
Pretravel PT
Overtravel OT min.
Movement Differential
MD max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
13.34 N
1.47 N
40°
42 max.
13.1
12.7
Depth: 15 min.
JIS B 0202 G½
Four, M6
29.2
±1.2
68.7
30.2
±0.2
40
±0.7
(4.9)
5
58.7
±0.2
(15.1)
14.7
60 max.
53
±1.5
41.5
±1.5
53.2
±0.8
* Stainless sintered roller
Two, M 3.5
Three, M4
Four, 5.2 dia. holes
17.5×7 dia. *
M5
Allen-head bolt
Fluorine
resin cap
25.4
25.4
40
±1.5
R38
21.6
Roller lever R38
With operation indicator (LED)
WLMCA2-LD-N
M5
Allen-head bolt
Three, M4
JIS B0202 G½
Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2 dia. holes
60 max.
25.4
68.7
12.7
25.4
13.1
40
±1.5
41.5
±1.5
53
±1.5
14.7
30.2
±0.2
40
±0.7
(4.9) (15.1)
58.7
±0.2
5
R38
Four, M3.5
17.5×7 dia. *
42 max.
53.2
±0.8
29.2
21.6
±1.2
Rubber cap
(125)
Roller lever R38
With operation indicator (LED)
WLMG2-LD
M5 (length: 12)
Allen-head bolt
Three, M4
(length: 13)
JIS B0202 G½
Effective thread:
4 threads min.
Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2+0.2 dia.
holes 0
60 max.
25.4
68.7
12.7
25.4
13.1
40±1.5
41.5±1.5
53±1.5
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
R38
Four, M3.5
(length: 26.5)
17.5×7 dia. *
42 max.
53.2±0.8
35
29.2
21.6
±1.2
Rubber cap
Lamp cover
Roller lever R38
With operation indicator (LED)
WLMGCA2-LD
+2°
-1°
+2°
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
73
Direct-wire connector
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLMCA2-LDK13A-N
WLMCA2-LDK43A-N
WLMCA2-LDK13-N
WLMCA2-LDK43-N
WLMG2-LDK13A
WLMG2-LDK43A
WLMG2-LDK13
WLMG2-LDK43
WLMGCA2-LDK13A
WLMGCA2-LDK43A
WLMGCA2-LDK13
WLMGCA2-LDK43
Operating force OF max.
Release force RF min.
Pretravel PT
Overtravel OT min.
Movement Differential
MD max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
13.34 N
1.47 N
40°
42 max.
13.1
12.7
Depth: 15 min.
Four, M6
29.2±1.2
68.7
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
14.7
60 max.
53±1.5
41.5±1.5
53.2±0.8
* Stainless sintered roller
Two, M3.5
Three, M4
M12×1
Four, 5.2 dia. holes
17.5×7 dia. *
M5 Allen-head bolt
Fluorine resin cap
25.4
25.4
40±1.5
R38
12.5
Roller lever R38
With operation indicator (LED)
WLMCA2-LDK13A-N
WLMCA2-LDK43A-N
WLMCA2-LDK13-N
WLMCA2-LDK43-N
Note: The photo shows the WLMCA2-LDK13-N model.
M5
Allen-head bolt
Three, M4
JIS B0202 G½
Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2 dia. holes
60 max.
25.4
68.7
12.7
25.4
13.1
40±1.5
41.5±1.5
53±1.5
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
12.5
Four, M3.5
17.5×7 dia. *
42 max.
53.2±0.8
29.2
21.6
±1.2
Rubber cap
SC-2FD
M12 x 1
Roller lever R38
With operation indicator (LED)
WLMG2-LDK13A
WLMG2-LDK43A
WLMG2-LDK13
WLMG2-LDK43
M5 (length: 12)
Allen-head bolt
Three, M4
(length: 13)
JIS B0202 G½
Effective thread:
4 threads min.
Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2+0.2 dia.
holes 0
60 max.
25.4
68.7
12.7
25.4
13.1
40±1.5
41.5±1.5
53±1.5
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
12.5
R38
Four, M3.5
(length: 26.5)
17.5×7 dia. *
42 max.
53.2±0.8
35
29.2
21.6
±1.2
Rubber cap
Lamp cover
SC-2FD
M12×1
Roller lever R38
With operation indicator (LED)
WLMGCA2-LDK13A
WLMGCA2-LDK43A
WLMGCA2-LDK13
WLMGCA2-LDK43
+2°
-1°
+2°
WL-N/WL
74
Pre-wired connectors
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Operating characteristics
Model
WLMCA2-LD-M1J-N
WLMCA2-LD-AGJ-N
WLMCA2-LD-DGJ-N
WLMCA2-LD-DTGJ-N
WLMG2-LD-M1J
WLMG2-LD-DGJ03
WLMG2-LD-DTGJ03
WLMGCA2-LD-M1J
WLMGCA2-LD-DTGJ03
Operating force OF max.
Release force RF min.
Pretravel PT
Overtravel OT min.
Movement Differential
MD max.
13.34 N
1.18 N
15±5°
70°
12°
9.81 N
0.98 N
10°
65°
13.34 N
1.47 N
40°
42 max.
13.1
12.7
Depth: 15 min.
Four, M6
29.2±1.2
68.7
30.2±0.2
40±0.7
(4.9)
5
58.7±0.2
(15.1)
14.7
60 max.
53±1.5
41.5±1.5
53.2±0.8
* Stainless sintered roller
Two, M3.5
17.5×7 dia. *
M5 Allen-head bolt
Fluorine resin cap
25.4
25.4
40±1.5
R38
SC-1M
XS2H-D421
Three, M4
Four, 5.2 dia. holes
50
+100
300
Roller lever R38
With operation indicator (LED)
Threaded (M12)
WLMCA2-LD-M1J-N
WLMCA2-LD-AGJ-N
WLMCA2-LD-DGJ-N
Smartclick
WLMCA2-LD-DTGJ-N
Note: The photo shows the
WLMCA2-LD-M1J-N
model.
M5
Allen-head bolt
Three, M4
Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2 dia. holes
60 max.
25.4
68.7
12.7
25.4
13.1
40±1.5
41.5±1.5
53±1.5
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
R38
Four, M3.5
17.5×7 dia. *
42 max.
53.2±0.8
29.2
21.6
±1.2
Rubber cap
(125)
SC-1M
XS2H-D421
50
+100
300
Roller lever R38
With operation indicator (LED)
Threaded (M12)
WLMG2-LD-M1J
WLMG2-LD-DGJ03
50
+100
300
M5 (length: 12)
Allen-head bolt
Three, M4
(length: 13)
Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2+0.2 dia.
holes 0
60 max.
25.4
68.7
12.7
25.4
13.1
40±1.5
41.5±1.5
53±1.5
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
(20)
R38
Four, M3.5
(length: 26.5)
17.5×7 dia. *
42 max.
53.2±0.8
35
29.2
21.6
±1.2
XS2H-D421
6 dia.
Lamp cover
Rubber cap
44.7
Roller lever R38
With operation indicator (LED)
Threaded (M12)
WLMGCA2-LD-M1J
Smartclick
WLMGCA2-LD-DTGJ03
M5
Allen-head bolt
Three, M4
(length: 13)
Four, M6
Depth: 15 min.
* Stainless sintered roller
Four, 5.2 dia. holes
60 max.
25.4
68.7
12.7
25.4
13.1
40±1.5
41.5±1.5
53±1.5
14.7
30.2
±0.2
40±0.7
(4.9) (15.1)
58.7±0.2
5
R38
Four, M3.5
17.5×7 dia. *
42 max.
53.2±0.8
29.2
21.6
±1.2
6 dia.
Rubber cap
XS5H-D421
50
+100
300
SC-1M
Roller lever R38
With operation indicator (LED)
Smartclick
WLMG2-LD-DTGJ03
+2°
-1°
+2°
WL-N/WL
75
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
Specifications
Approved Standards
Approved Standard Ratings
UL/cUL, CSA (UL508, CSA C22.2 No.14) A600 Authentication conditions
C300 Authentication conditions
A300 Authentication conditions
A150 Authentication conditions
C150 Authentication conditions
TÜV (EN 60947-5-1)
(Certification only for Direct-wire cable type switches and Pre-wired
DC switches with connectors)
CCC (GB14048.5)
Common Specifications
General-purpose/Environment-resistant/Spatter-prevention/Long-life Switches
Agency Standard File No. Approved models
UL UL508
Contact your OMRON
representative for
information
Contact your OMRON representative for information
CSA cUL CSA C22.2 No.14
TÜV Rheinland EN60947-5-1
CCC (CQC) GB14048.5
Specifications Approved
Standards
Operation
Indicator
Sensor I/O
connectors Item
No
indicator
No connector
Basic models A600
1 A, 125 VDC
High-sensitivity and
High-precision models A600
Pre-wired
connector (AC)
Basic, High-sensitivity or
High-precision models
C300
3 A, 250 VAC
Pre-wired
connector (DC)
Direct-wire
connector (DC)
Basic models 1 A, 125 VDC
High-sensitivity and
High-precision models
0.8 A,
125 VDC
Neon lamp
No connector
Basic models A300
10 A, 250 VAC
High-sensitivity and
High-precision models
Pre-wired
connector (AC)
Basic, High-sensitivity or
High-precision models
C300
3 A, 250 VAC
LED
No connector
Basic models
A150
10 A, 115 VAC
1 A, 115 VDC
High-sensitivity and
High-precision models
A150
10 A, 115 VAC
0.8 A, 115
VDC
Pre-wired con-
nector (AC)
Basic, High-sensitivity or
High-precision models
C150
3 A, 115 VAC
Pre-wired
connector (DC)
Direct-wire
connector (DC)
Basic models 1 A, 115 VDC
High-sensitivity and
High-precision models
0.8 A, 115
VDC
Rated
voltage
Carrying
current
Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
10 A
60
30
15
12
6
3
1.5
1.2
7,200 720
Rated
voltage
Carrying
current
Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC
240 VAC 2.5 A 15
7.5
1.5
0.75 1,800 180
Rated
voltage
Carrying
current
Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC
240 VAC 10 A 60
30
6
37,200 720
Rated
voltage
Carrying
current
Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
Rated
voltage
Carrying
current
Current (A) Volt-ampere (VA)
Make Break Make Break
120 VAC 2.5 A 15 1.5 1,800 180
Authentication
conditions
Specifications
Direct-wire cable type
With Pre-
wired DC
connector
model
No indicator
Neon
lamp
LED
Working load category
AC-15 DC-12 AC-15 AC-15 DC-12
DC-12
Rated working voltage (Ue)
250 V 48 V 250 V 115 V 48 V
48 V
Rated working current (Ie)
2 A
Conditional
short-circuit current 100 A
Short-circuit
protective device (SCPD)
10 A, fuse type gG
Rated insulation voltage (Ui)
250 V 48 V
Rated impulse dielectric
strength (Uimp)
4 kV 800 V
Pollution degree 3
Protection against
electric shock Class I Class III
Authentication
conditions
Specifications
No
indicator
Neon
lamp LED
With Pre-
wired DC
connector
model
With Pre-
wired AC
connector
model
Working load
category
AC-15 DC-13
AC-15
AC-15 DC-13
DC-13 AC-15
Rated working
voltage (Ue)
250 V 48 V
250 V
250 V 48 V
48 V 250 V
Rated working
current (Ie) 2 A
Conditional
short-circuit
current
1000 A
Short-circuit
protective
device (SCPD)
10 A, fuse type gG
Rated
insulation
voltage (Ui)
250 V
76
WL-N/WL
Ordering Information
Single-item ordering models
General-purpose Models
Spatter-prevention Models
* The actuator is identical for the WL and WL-N models.
Common Accessories (Sold Separately)
Actuator Pretravel (PT) Set Model Numbers Switches without levers Heads (with Actuators) Actuator *
Model Model Model
Roller lever: R38 mm
15±5° WLCA2-N WLRCA2-N WL-1H1100-N
WL-1A100
25±5° WLCA2-2-N WLRCA2-2-N WL-3H1100-N
20° max. WLCA2-2N-N WLRCA2-2N-N WL-1H1100-N
10° WLG2 --- WL-2H1100
Adjustable roller lever
(R25 to 89 mm)
15±5° WLCA12-N WLRCA2-N WL-1H2100-N
WL-2A100
25±5° WLCA12-2-N WLRCA2-2-N WL-3H2100-N
20° max. WLCA12-2N-N WLRCA2-2N-N WL-1H2100-N
10° WLG12 WLRG2 WL-2H2100
Adjustable rod lever:
(25 to 140mm)
15±5° WLCL-N WLRCL-N WL-4H4100-N
WL-4A100
25±5° WLCL-2-N WLRCA2-2-N WL-3H4100-N
20° max. WLCL-2N-N WLRCA2-2N-N WL-1H4100-N
10° WLGL WLRG2 WL-2H4100
Sealed top plunger 1.7 mm max. WLD18-N --- WL-7H100-N ---
Sealed top-roller plunger 1.7 mm max. WLD28-N --- WL-7H400-N ---
Sealed top-ball plunger 1.7 mm max. WLD38-N --- WL-7H300-N ---
Horizontal plunger 2.8 mm max. WLSD-N --- WL-8H100-N ---
Horizontal-roller plunger 2.8 mm max. WLSD2-N --- WL-8H200-N ---
Horizontal-ball plunger 2.8 mm max. WLSD3-N --- WL-8H300-N ---
Coil spring (6.5 dia.) 20±10 mm WLNJ-N --- WL-9H100-N ---
Coil spring (4.8 dia.) 20±10 mm WLNJ-30-N --- WL-9H200-N ---
Flexible rod: Resin rod
(8 dia.) 40±20 mm WLNJ-2-N --- WL-9H300-N ---
Flexible rod: Steel wire
(1 dia.) 40±20 mm WLNJ-S2-N --- WL-9H400-N ---
Fork Lock Lever (1) 55° max. WLCA32-41-N
WLRCA32-N
WL-5H5100-N WL-5A100
Fork Lock Lever (2) 55° max. WLCA32-42-N WL-5H5102-N WL-5A102
Fork Lock Lever (3) 55° max. WLCA32-43-N WL-5H5104-N WL-5A104
Fork Lock Lever (4) 55° max. WLCA32-44-N WL-5H5104-N WL-5A104
Actuator Lever type Indicator Pretravel (PT) Set Model Numbers Switches without levers Actuator *
Model Model
Roller lever:
R38 mm
Double nut lever
LED 15±5° WLCA2-LDAS-N WLRCA2-LDS-N
WL-1A105S
Neon lamp WLCA2-LEAS-N WLRCA2-LES-N
LED 10° WLG2-LDAS WLRG2-LDS
Allen-head lever
LED 15±5° WLCA2-LDS-N WLRCA2-LDS-N
WL-1A103S
Neon lamp WLCA2-LES-N WLRCA2-LES-N
LED 10° WLG2-LDS WLRG2-LDS
. . . . . . . . . . . . Switches without levers, heads, and actuators can be ordered separately. Use by combining with models that are
not available as a set. You can also use them as maintenance parts for inventory management.
+2°
-1°
+2°
-1°
+2°
-1°
+2°
-1°
+2°
-1°
WL-N/WL
77
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
Connector (Conduit size: JIS B0202G1/2)
Note: 1. Please use sealling tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape
is not necessary to ensure a proper seal. The SC-6 and SC-P2 models are made of resin. If higher sealing performance is required, use
one of SC-1M to SC-5M, which have metal connectors.
2. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
* mark dimensional table
Appearance
Dimensions
(Unless otherwise indicated, a tolerance of ±0.4 mm applies to
all dimensions.)
Application/
Specifications
Inner
diameter
(D) of seal
rubber
External
diameter
of cable Model
Applicable
limit switch
models
min.
max.
Cabtire cable
(Metal)
7 dia. 5.5
dia.
7.5
dia. SC-1M
WL@-N
WLG@
Wiring
Specifications:
Screw
terminals
9 dia. 7.5
dia.
9.5
dia. SC-2M
12.5 dia. 11
dia.
13
dia. SC-3M
14 dia. 12
dia.
14
dia. SC-4M
11 dia. 9
dia.
11
dia. SC-5M
Cabtire cable
(Metal, with
O-ring)
7 dia. 5.5
dia.
7.5
dia. SC-21
9 dia. 7.5
dia.
9.5
dia. SC-22
12.5 dia. 11
dia.
13
dia. SC-23
14 dia. 12
dia.
14
dia. SC-24
11 dia. 9
dia.
11
dia. SC-25
Cabtire cable
(Resin)
9 dia. 7.5
dia.
9
dia. SC-6
10.6 dia. 8.5
dia.
10.5
dia. SC-P2
Model
Inner diameter (D)
of sealed rubber
Internal
diameter (E) of
washer
Applicable
cable
SC-21, -1M, -1PT 7 dia. 10.4 dia. 5.5 dia. to 7.5
dia.
SC-22, -2M, -2PT 9 dia. 13.2 dia. 7.5 dia. to 9.5
dia.
SC-23, -3M, -3PT 12.5 dia. 14.6 dia. 11 dia. to 13 dia.
SC-24, -4M, -4PT 14 dia. 14.6 dia. 12 dia. to 14 dia.
SC-25, -5M, -5PT 11 dia. 13.2 dia. 9 dia. to 11 dia.
SC-6 9 dia. 10 dia. 7.5 dia. to 9 dia.
14 dia.
14.6 dia.
30
29.3
*E 15 59
(34)
27
JIS B 0202 G
½
*D
Sealing rubber
(nitrile rubber)
Connector
(zinc die-cast and
zinc plating)
Washer (stainless steel)
Ball head lock nut
(zinc die-cast and zinc plating)
Sealing rubber (nitrile rubber)
*D
Sealing rubber
(nitrile rubber)
Connector
(brass and nickel plating)
Washer (stainless steel)
Ball head lock nut
(brass and nickel plating)
27.729.3
15 4.89
24
14 dia.
14.6 dia.
*E
(34)
JIS B 0202 G½
22.5
26
9
G
1
½
5
12
9
10
(30.6)
12
9
*D
Sealing rubber (nitrile rubber)
Connector
(polyacetal resin)
M20×1.5
Washer
(ferrous metal and
zinc plating)
Ball head lock nut
(polyacetal resin)
22
25.4
15
12.6 dia. 10.6 dia.
18 dia.
1 4.5
18 dia.
5
JIS B 0202
G
1
½
Hexagonal nut
(polyacetal resin) Conduit washer
(ferrous metal and zinc plating)
Ring (chloroprene rubber)
78
WL-N/WL
Sensor I/O connectors
Note: For details, refer to the data sheet for XS2 Round Water-resistant Connectors (M12 Threads) or XS5 Round Water-resistant Connectors
(M12 Smartclick).
*1. The default setting is for light-ON when not operating. Turn the lamp holder by 180° to change the setting to light-ON when operating.
*2. The Color Universal Design structure is certified by an NPO. Certification conditions: Ambient illumination of 500 lx max. (JIS Z 9110)
Appearance AC/DC
type
Number of cable
cores Cable length (m) Cable model Compatible model
M12 Screw (Straight)
for AC
22XS2F-A421-DB0-F WL@-@K13A-N
WLG@-@K13A
5XS2F-A421-GB0-F
4
2XS2F-A421-D90-F WL@-@K43A-N
WL@-@-AGJ-N
WLG@-@K43A
WLG@-@-AGJ03
5XS2F-A421-G90-F
for DC
2
2XS2F-D421-DD0 WL@-@K13-N
WL@-@-M1J-N
WLG@-@K13
WLG@-@-M1J
5XS2F-D421-GD0
2XS2F-D421-DA0-F WL@-@-M1GJ@-N
WLG@-@-M1GJ@
5XS2F-D421-GA0-F
4
2XS2F-D421-D80-F
WL@-@K43-N
WL@-@-M1JB-N
WL@-@-DGJ-N
WL@-@-DK1EJ-N
WLG@-@K43
WLG@-@-M1JB
WLG@-@-DGJ03
WLG@-@-DK1EJ03
5XS2F-D421-G80-F
M12 Smartclick
(Straight)
for DC 4
2XS5F-D421-D80-F
WL@-@-M1TJ-N
WL@-@-M1TGJ-N
WL@-@-M1TJB-N
WL@-@-DTGJ-N
WL@-@-DTK1EJ-N
WLG@-@-M1TJ
WLG@-@-M1TGJ
WLG@-@-M1TJB
WLG@-@-DTGJ03
WLG@-@-DTK1EJ03
5XS5F-D421-G80-F
Type Compatible model Remarks Model
Cover with indicator lamps
*1
WL-N/WLG
General-purpose models
Long-life models
(Basic models, High-sensitivity Switches)
Indicator *1
LED Color: Red WL-LD-N
Color: YellowWL-LW-N *2
Neon lamp Color: Orange WL-LE-N *2
Spatter Prevention models LED Color: Red WL-LDS-N
Neon lamp Color: Orange WL-LES-N
Long-life models
(High-precision Switches)
LED Color: Red WL-LD
Neon lamp Color: Orange WL-LE
Terminal Plate
WL@-N
Change from bipolar to monopolar (contact C).
Use in basic and high-sensitivity switches that
are general-purpose, environment-resistant,
spatter-prevention, and long-life.
WL-N
TERMINAL PLATE
WL Change from bipolar to monopolar (contact C).
Use in long-life high-sensitivity switches.
WL
TERMINAL PLATE
Side mounting plate WL@-2N-N --- WLN-P001
Color Universal Design was developed in consideration of people with various types of color vision to allow information to be
accurately conveyed to as many individuals as possible.
WL-N/WL
79
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
Dimensions (Unit: mm)
Wiring Diagram
XF2F
XF5F
AC/DC Type Two-core model Four-core model
Model Wiring Diagram Model Wiring Diagram
AC XS2F-A421-DB0-F
XS2F-A421-GB0-F
XS2F-A421-D90-F
XS2F-A421-G90-F
DC
XS2F-D421-DD0
XS2F-D421-GD0
XS2F-D421-D80-F
XS2F-D421-G80-F
XS2F-D421-DA0-F
XS2F-D421-GA0-F
AC/DC Type Four-core model
Model Wiring Diagram
DC XS5F-D421-D80-F
XS5F-D421-G80-F
Sensor I/O connectors
XS2F-A421-@@0-F
XS2F-D421-@D0
XS2F-D421-@@0-F
6 dia.
40.7
14.9 dia.
L50
30 5
45°
5 dia.
M12×1 45°
5 dia.
M12×1
for DC for AC
XS5F-D421-@80-F
40.7
L (Cable length)
50
30 5
M12×1
14.9 dia.
1
2
3
4
Brown
Blue
Terminal No. Cable color of
core sheath
1
2
3
4Blue
Black
Brown
White
Terminal No. Cable color of
core sheath
1
2
3
4
Blue
Brown
Terminal No. Cable color of
core sheath
1
2
3
4
Brown
Blue
Terminal No. Cable color of
core sheath
1
2
3
4Blue
Black
Brown
White
Terminal No. Cable color of
core sheath
4
R0.5
7.5
14.7
7.9
3.7±0.1 dia.
3.7±0.1 dia.
12.5
Terminal Plate
WL-N TERMINAL PLATE
9
2.5
+0.2
0
4.2
R2.1 3.5
7R2
R3
7.1
+0.1
0
9
±0.2
16
COM
±0.15
23
±0.4
t = 0.6 Brass plate
Terminal Plate
WL Terminal Plate
Side mounting plate
WLN-P001
23
64
30.2
58.7
WL@-2N
Mounting Plate
Replacing a Switch
with the WL@-2N-N
Mounting Plate
Set
contents
Plate mounting
bolts (2)
Plate (1)
Switch mounting
bolts (2)
80
WL-N/WL
Actuator
General-purpose Models
Actuator
Spatter-prevention Models
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
11.4
17.5 dia. × 7,
stainless sintered roller
7.3-dia.
mounting
holes 38
16 M5
Allen-head bolt
54.8
17.9
12.6
WL-1A100
16
12
17.5 dia. × 7,
stainless sintered roller
Adjustable lever:
stainless steel
7.3-dia.
mounting
holes M5
Allen-head
bolt
Adjustable
range:
25 to 89
24.9
±0.8
23
19.7
±0.8
105.75
WL-2A100
WL-4A100
3-dia. stainless
steel rod
7.3-dia. mounting
holes
M5
Allen-head
bolt
Adjustable
from
25 to 140
160
9
19
11
M8
Allen-head
set screw
WL-5A100 has a plastic roller
Two, 17.5 dia. × 7,
plastic roller
M5 × 16
Allen-head bolt 11
1.3
6.7 17.7
54.8
90°
R38
7.3 dia.
12.4
WL-5A100
WL-5A102 has a plastic roller
Two, 17.5 dia. × 7,
plastic roller
M5 × 16
Allen-head bolt 11
1.3
17.7
54.8
90°
R38
7.3 dia.
6.7
12.4
WL-5A102
WL-5A104 has a plastic roller
Two, 17.5 dia. × 7,
plastic roller
M5 × 16
Allen-head bolt 11
17.7
12.4
54.8
90°
R38
7.3 dia.
WL-5A104
11.4
17.5 dia. × 7
stainless steel roller
7.3-dia.
mounting
holes 38
16 M5
Allen-head bolt
54.8
17.9
12.6
WL-1A103S
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
81
Safety Precautions
For the Safety Precautions for All Limit Switches, refer to the OMRON website.
Meanings of Warning Signal Text
•Be sure to ground. Otherwise electric shock may result.
Do not touch charged switch terminals while the switch has carry
current, Otherwise electric shock may result.
Do not disassemble the limit switch or touch inside of it under
supplying power, Otherwise electric shock may result.
Do not disassemble or touch the inside while the power is turned
on. Otherwise electric shock may result.
Do not touch the wire or rod type actuator in order to prevent injury.
Doing so may result in injury.
Connect a fuse which has 1.5 to 2 times higher breaking current
than the switch rated current to the switch in series in order to
prevent the switch from short-circuit damage.
On the occasion when using the switch with EN/IEC/GB ratings,
use a 10 A fuse that complies IEC60269, either type gG.
The durability of switch is depends on the operating condition Be
sure to check the condition with actual using condition before
using, and use with the number of times of operating without a
performance problem.
Otherwise, there is the possibility of spoiling the normal operation.
Do not drop the switch.
Do not connect a Single Limit Switch to two power supplies that are
different in polarity or type. Risk of interference.
•Be sure to keep the load current less than the rated value.
Otherwise, there is the possibility that the switch may be damage
and/or burnout.
Do not use the Switch by itself in atmospheres containing
flammable or explosive gases. Arcs and heating resulting from
switching may cause fire or explosion.
•Be sure to prevent the foreign materials such like a scrapped cable
intrusion in to the switch when wiring. Otherwise, there is the
possibility of spoiling the normal operation.
•Never wire to the wrong terminals.
Using the Switch in a pressed-in state for an extended period of
time can accelerate part deterioration and also lead to failure to
return to the original position. Check the Switch beforehand, and
perform periodic inspection and replacement.
Do not store or use the switch with following place.
Where the temperature fluctuates greatly.
Where the humidity is very high and condensation may occur.
Where the vibration is too much.
Where receiving direct sunshine.
Where receiving salty wind.
Where exposed to cutting powder, machining chips, oil, and
chemicals inside the protective doors.
Where exposed to cleansers, thinners, and other solvents
Do not use or store the Switch in locations with corrosive gas, such
as sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas
(HNO3), or chlorine gas (Cl2), or high temperature and humidity.
Otherwise, contact failure or corrosion damage may result.
Do not disassemble and/or modify the switch at anytime.
Otherwise, there is the possibility of spoiling the normal operation.
Do not apply the force such like deformation and/or degeneration
to the switch.
If the Switch will not be switched ON or OFF for an extended period of
time, contact reliability may degrade due to oxidation of the contact
points, resulting in inadequate conductivity, which could lead to an
accident.
Operating Environment
•This switch is only for indoor use. If it is used in outdoor, it may be
cause of switch failure.
Take special care to use where there is fine powder, mud and/or
foreign materials stacking. And check the condition with actual
using condition before using. Then use without a performance
problem.
Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
•Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near
the Switch, suppress arcing with contact protective circuits (surge
suppressor) or remove the source of silicon gas.
Installing the Switch
To install the Switch, make a mounting panel, as shown in the
following diagram, and tighten screws using the appropriate
tightening torque.
Precautions
for Safe Use Indicates an action that must be performed or
avoided for safe use of this product.
Precautions
for Correct
Use
Indicates an action that must be performed or
avoided for preventing operation failure or
malfunction of the product or adverse impact
on performance or functionality.
Precautions for Safe Use
Precautions for Correct Use
Not Suitable Suitable
±0.15
30.2
58.7±0.15
+0.2
0
+0.2
0
Front Mounting : Four, 5.2 dia. holes
or M5 tapped holes
Rear Mounting : Four, 6.2 dia. holes
WL-N/WL
82
Appropriate Tightening Torque
If screws are too loose they can lead to
an early malfunction of the Switch, so
ensure that all screws are tightened
using the appropriate tightening
torque.
In particular, when changing the
direction of the Head, make sure that
all screws are tightened again to the
appropriate tightening torque. Do not
allow foreign objects to fall into the
Switch.
Using Switches for Micro Loads
•The switch contacts can be used both for standard loads and
microloads, but once a contact has been used to open and close a
load it can no longer be used for lower loads. Doing so will damage
the contact surface and reduce contact reliability.
If an inrush current or other sudden load occurs during a switch
operation, the switch will begin to degrade severely which can
result in reduced durability. Use a contact protection circuit if
required.
For the WL-N, the P level is at the min. operating load of 5 VDC and
1 mA resistive load.
Note: The P level indicates the standard malfunction level at a
reliability level of 60% (λ60). (JISC5003) λ60 = 0.1×10-6/
operations indicates that the estimated malfunction rate is less
than 1/10,000,000 operations with a reliability level of 60%.
Wiring
In the case of mounting screw
Basic models
Use M3.5-nylon insulation covered crimp terminals (round type) for wiring.
Ex.) N1.25-M3.5 (RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.)
Appropriate wire size is AWG16 (1.25 mm2).
Do not supply electric power when wiring. Otherwise electric shock
may result.
Do not pull out the wires with excessive force. It may cause of
coming off the wire.
•Avoid connecting the wires directly to the terminal. Instead, attach
using a crimp terminal.
In the case of indicator unit, to avoid interference
between lump unit and crimp terminals, wire
according to right wiring figure.
Attach the indicator unit spring to terminal screw
certainly, otherwise it's possible to be destroyed or
shorted.
The ground terminal is only installed on models
with ground terminals.
In the case of prewired connector and direct
connector
Holding the connector certainly when pulling connector.
Don’t pull the cable holding it.
How to handle
Changing direction of the head
•By removing two head screws or four head screws, mounting in
any of four orientations is possible. Be sure to change the plunger
for internal operations at the same time.
Built-in Switch
Do not remove or replace the built-in switch. Risk of
malfunctioning.
Overtravel Markers
•All Switches with Roller Lever Actuators except for Switches with
Fork Lock Levers and Low-temperature Switches have a set
position marker plate.
To allow the roller lever type actuator to travel properly, set the
roller lever according to the dog or cam stroke so that the
arrowhead of the lever is positioned within the overtravel markers
(pages 15, 16). This enables usage in the optimum state.
No.
Item Torque Screw type
(1) Head mounting screw0.78 to 0.88 N·m M3.5 screw
(2) Cover mounting screw1.18 to 1.37 N·m M4 screw
(3)
Allen-head bolt
(for securing the roller
lever)
4.90 to 5.88 N·m M5 Allen-head
bolt
(3)
Allen-head bolt
(for securing the roller
lever)
0.88 to 1.08 N·m M8 hexagon
socket set screw
(4) Terminal screw0.59 to 0.78 N·m
M3.5 screw
(WL-N model), M4
screw (WL model)
(5) Connectors 1.77 to 2.16 N·m G1/2 or Pg13.5 or
M20 or 1/2-14NPT
(6) Unit mounting screw4.90 to 5.88 N·m M5 screw
Back mounting screws 4.90 to 5.88 N·m M6 screw
(3)
(4)
(2)
(1)
(6)
(5)
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
83
Conduit opening preparation
The connector must be tightened at a suitable tightening torque
(1.77 to 2.16 N). Tightening with excessive torque could damage
the case.
Select the connector based on the sealed rubber inner diameter for
matching the cable outer diameter. For details, refer to
Accessories (Sold Separately) - Connector (Conduit size: JIS
B0202G1/2) on page 77.
When mounting the connector, use seal tape (not needed if the
connector includes an O-ring) on the threaded section of the
connector to ensure sealing performance.
To ensure compliance of this Switch with the CSA standards, use
of a waterproof connector compliant with the CSA is
recommended.
Using an inappropriate connector or assembling Switches
incorrectly (assembly, tightening torque) can result in malfunction,
leakage current, or fire, so be sure to read the connector instruction
manual thoroughly beforehand.
•Even when the connector is assembled and set correctly, the end
of the cable and the inside of the Switch may come in contact. This
can lead to malfunction, leakage current, or fire, so be sure to
protect the end of the cable from splashes of oil or water and
corrosive gases.
The following wiring is recommended for preventing the entry of
fluids from the conduit opening.
Microload Applications
The WL-N basic model, WL high-sensitivity model, and high-
precision model contacts can be used both for standard loads and
microloads, but once a contact has been used to open and close a
load, it can no longer be used for lower loads. Doing so will damage
the contact surface and reduce contact reliability.
If an inrush current or other sudden load occurs during a switch
operation, the switch will begin to degrade severely which can
result in reduced durability. Use a contact protection circuit if
required.
Operaition indicator
Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the indicator
circuit and may cause load's malfunction. Leakage current may cause
load malfunction (i.e., the load may remain ON). Make sure that the
load operating current is higher than the leakage current. For
countermeasures, refer to technical support on your OMRON
website.
Terminal Plate
By using the Terminal Plate (sold separately), as shown in the
following diagram, the Switch can be used as a single-polarity double-
break switch.
Use in basic and high-sensitivity switches that are
general-purpose, environment-resistant, spatter-
prevention, and long-life
WL-N TERMINAL PLATE
Use in long-life high-sensitivity switches
WL Terminal Plate
For details, refer to page 79.
To customers using the WL@-2N series model in a side-
mounted configuration
We provide a special mounting plate (sold separately) that features
mounting compatibility when replacing with the WL@-2N-N series. If
you use the Mounting Plate, the Switch mounting holes and actuator
position will be compatible. Note: The position of the dog remains
unchanged.
(1) Connector tube
contains internal
stranded wire
(2) Connector tube
contains internal
stranded wire and
external jacket
(3) Connector tube
contains external
jacket
Terminal Plate
Attach the Terminal Plate
so that the “COM” mark is
oriented as shown on the left.
Terminal Plate Mounting Diagram
(with Two Terminal Screws Removed)
23
64
30.2
58.7
WL@-2N
side-mounted
Replacing a Switch
with the WL@-2N-N
Mounting Plate
Set
contents
Plate mounting
bolts (2)
Plate (1)
Switch mounting
bolts (2)
WL-N/WL
84
Operation Procedures
Operation
Carefully determine the position and shape of the dog or cam so
that the actuator will not abruptly snap back, thus causing shock.
In order to operate the Limit Switch at a comparatively high speed,
use a dog or cam that keeps the Limit Switch turned ON for a
sufficient time so that the relay or valve will be sufficiently
energized.
The method of operation, the shape of the cam or dog, the
operating frequency, and the travel after operation have a large
influence on the durability and operating accuracy of the Limit
Switch. The cam or dog must be smooth in shape.
Appropriate force must be imposed on the actuator by the cam or
dog in both rotary operation and linear operation. If the dog
touches the lever as shown below, the operating position will not
be stable.
Unbalanced force must not be imposed on the actuator. Otherwise,
wear and tear on the actuator may result.
With a roller actuator, the dog must touch the actuator at a right
angle. The actuator or shaft may deform or break if the dog touches
the actuator (roller) at an oblique angle.
•M
ount so that the actuator travel after operation (OT) is not
exceeded. If the travel after operation (OT) exceeds the limit,
switch failure could result. When mounting the Limit Switch, be
sure to adjust the Limit Switch carefully while considering the
whole movement of the actuator.
The Limit Switch may soon malfunction if the OT is excessive.
Therefore, adjustments and careful consideration of the position of
the Limit Switch and the expected OT of the operating body are
necessary when mounting the Limit Switch.
When using a pin-plunger actuator, make sure that the stroke of
the actuator and the movement of the dog are located along a
single straight line.
Others
If the Switch will be left in a location outside the storage
environment conditions, if condensation has formed, or after long-
term storage exceeding one year, at the minimum, check the
operating characteristics, contact resistance, insulation resistance,
and dielectric strength, and conduct a check under the operating
conditions.
If using normal open (NO), be sure to fully press in the actuator. The
proper press-in depth is about 60% to 80% of the entire motion (TT).
Conduct periodic inspection on a regular schedule.
Incorrect Correct
Snapped
back
Abruptly
actuated
Incorrect Correct
Snapped
back Abruptly
actuated
Incorrect
Dog Dog
Correct
Incorrect Correct
RollerRoller
Dog Dog
CorrectIncorrect
Dog
Dog
Operating
body
Install a stopper.
PT (Pretravel)
FP (Free position)
OP (Operating position)
OT (Overtravel)
TTP (Total travel position)
Reference line
70% of
rated OT 100% of
rated OT
Distance to the
optimum setting range.
Optimum setting range
Correct
Stopper
Incorrect Correct
Operating
body
Operating
body
WL-N/WL
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches Accessories Safety Precautions
85
Using the Switches
Item Applicable models and Actuators Details
Changing the Installation Position of the
Actuator
By loosening the Allen-head bolt on the ac-
tuator lever, the position of the actuator can
be set anywhere within the 360°.
With Operation Indicator-equipped Switch-
es, the actuator lever comes in contact with
the top of the indicator cover, so use caution
when rotating and setting the lever. When
the lever only moves forwards and back-
wards, it will not contact the lamp cover.
(This does not apply to Long-life Models.)
Roller lever:
(WLCA2-N, WLCA2-2-N, WLCA2-2N-N,
WLG2, WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N, WLMG2,
WLMGCA2)
Adjustable roller lever
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12)
Adjustable rod lever
(WLCL-N, WLCL-2-N, WLCL-2N-N,
WLGL, WLCAL4-N, WLCAL5-N)
Changing the Orientation of the Head
By removing the head screws (two or four
screws), mounting in any of four orientations
is possible. Be sure to change the plunger
for internal operations at the same time.
The roller plunger can be set in either of two
positions at 90°.
Roller lever:
(WLCA2-N, WLCA2-2-N, WLCA2-2N-N,
WLG2, WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N, WLMG2,
WLMGCA2)
Adjustable roller lever
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12)
Adjustable rod lever
(WLCL-N, WLCL-2-N, WLCL-2N-N,
WLGL, WLCAL4-N, WLCAL5-N)
Horizontal plunger
(WLSD@-N)
Top-roller plunger
(WLD2-N)
Sealed top-roller plunger
(WLD28-N)
Fork lock lever (WLCA32-4@-N)
Note: Does not include -RP60 Series or
-141 Series
Changing the Operating Direction
By removing the Head on models which can
operate on one-side only, and then changing
the direction of the operational plunger, one
of three operating directions can be select-
ed.
The tightening torque for the screws on the
Head is 0.78 to 0.88 N·m.
Roller lever:
(WLCA2-N, WLCA2-2-N, WLCA2-2N-N,
WLCA2-7-N, WLCA2-8-N, WLMCA2-N)
Adjustable roller lever
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N)
Adjustable rod lever
(WLCL-N, WLCL-2-N, WLCL-2N-N,
WLCAL4-N, WLCAL5-N)
Roller lever:
(WLGCA2, WLMGCA2)
Loosen the Allen-head bolt, set
the actuator's position and then
tighten the bolt again.
Head Loosen the screws.
Operating Operating Operating
Not operating
Operating Not operating
Operation in both
directions
Clockwise operation Counterclockwise
operation
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
One-side Operation for General Models
The output of the Switch will
only be changed when the lever
is pushed in one direction.
Operating Operating
Operation in both
directions
OperatingNot operating
Clockwise operation
Operating Not operating
Operational
plunger
Counterclockwise
operation
One-side Operation for High-precision Switches
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
The output of the Switch will
only be changed when the lever
is pushed in one direction.
WL-N/WL
86
Operation of Fork Lock Levers
A Switch with a Fork Lock Lever is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after
the dog moves on. If the dog then pushes the lever from the opposite direction, the lever will return to its original position.
Installing the Roller on the Inside
By installing the roller lever in the opposite
direction, the roller can be installed on the in-
side. (Set so that operation can be complet-
ed within a 180° level range.)
Roller lever:
(WLCA2-N, WLCA2-2-N, WLCA2-2N-N,
WLG2, WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N, WLMG2,
WLMGCA2)
Fork lock lever
(WLCA32-4@-N)
Adjusting the Length of the Rod or Lever
The length of the rod or lever can be adjust-
ed by loosening the Allen-head bolt.
Adjustable roller lever
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12)
Adjustable rod lever
(WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL,
WLCAL4-N)
Selecting the Roller Position
There are four types of Switches with Fork
Lock Levers for use depending on the roller
position.
Fork lock lever:
(WLCA32-4@-N)
An explanation of the operation of fork lock levers is provided
after this table.
Item Applicable models and Actuators Details
Loosen the
Allen-head bolt.
Loosen this
Allen-head bolt
and adjust the
length of the rod.
Adjustment
range radius:
R25 to R89 mm
Adjustable Roller Levers: Adjustable Rod Levers:
Loosen this
Allen-head bolt
and adjust the
length of the
lever.
Adjustment
range radius:
25 to 140 mm
WLCA32-41-N WLCA32-43-N
WLCA32-42-N WLCA32-44-N
NC terminal: ONNO terminal: ONNO terminal: ON
Example
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. C151-E1-03 0319 (1217)
© OMRON Corporation 2017-2019 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
CSM_1_13_0619