5.7" (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT Part Number Blower Data Unit of Measure Stages Standard Flow High Flow 117634 M* 117633 M 117632 M* 117637 M* 117636 M* 117635 M* 117640 E* 117639 E 117638 E* 117643 E* 117642 E* 117641 E* 1 2 3 1 2 3 Vacuum, Max. (Sealed Vacuum) in. H2O mBar 28 69 45 112 60 149 23 57 39 97 53 131 Pressure, Max. (Sealed Pressure) n. H2O mBar 30 74 51 126 70 174 25 62 45 112 61 151 Flow Rate, Max. (Open Flow) CFM L/sec 69 33 62 29 58 27 114 54 97 46 86 41 Inlet/Outlet Diameter (Dimension "D" above) inches mm 1.25 31.75 1.25 31.75 1.25 31.75 1.75 44.45 1.75 44.45 1.75 44.45 Length (Dimension "I" above) inches mm 2.53 64.26 1.25 31.75 2.14 54.36 .47 11.94 1.53 38.86 2.53 64.26 Length (Dimension "L" above) inches mm 5.08 129.03 5.99 152.15 6.89 175.01 5.22 132.59 6.27 159.26 7.28 184.91 Typical Performance Points Air Flow Pressure 0 CFM 10 CFM in. H2O in. H2O 30.3 27.9 51.0 44.2 69.9 59.9 24.8 23.6 44.6 41.0 61.5 55.8 20 CFM 30 CFM in. H2O in. H2O 26.2 23.6 41.8 35.9 52.8 44.1 22.6 21.5 39.8 35.8 51.5 46.0 40 CFM 50 CFM in. H2O in. H2O 19.0 13.3 27.8 16.6 32.1 18.1 19.5 17.9 32.0 28.0 40.1 34.2 60 CFM 70 CFM in. H2O in. H2O 7.0 3.7 3.7 16.1 13.8 23.9 17.9 28.2 19.6 80 CFM 90 CFM in. H2O in. H2O 12.0 8.7 12.1 0 8.1 100 CFM 110 CFM in. H2O in. H2O 6.7 0 *These part numbers are available through AMETEK Rotron distributors. NOTES: * Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz * Input current: 5 amps AC RMS maximum * Temperature: Working Air: 0C to 50C, Ambient Air: 0C to 50C, Storage Air: -40C to 85C * Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. * Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. 36 5.7" (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT * Maximum Approximate Weight: 6 lbs. * Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. R0097184. Underwriters Laboratories, Inc. Qualified per UL507 under File E-94403. Canadian Standards Association Qualified per C22.2#113 under File LR 43448. * Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp housing #1-480763-0 (to be supplied by customer), mates with post header assembly. IEC 801 testing has been completed, and specific data can be provided upon request. Mating harness available upon request. Refer to (page 84) for specific part numbers. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 37