36
Part Number
Standard Flow High Flow
Blower Data Unit of
117634 M*117633 M 117632 M*117637 M*117636 M*117635 M*
Measure
117640 E*117639 E 117638 E*117643 E*117642 E*117641 E*
Stages 1 2 3 1 2 3
Vacuum, Max. (Sealed Vacuum) in. H2O2845 60233953
mBar 69 112 149 57 97 131
Pressure, Max. (Sealed Pressure) n. H2O3051 70254561
mBar 74 126 174 62 112 151
Flow Rate, Max. (Open Flow) CFM 69 62 58 114 97 86
L/sec 33 29 27 54 46 41
Inlet/Outlet Diameter inches 1.25 1.25 1.25 1.75 1.75 1.75
(Dimension “D” above) mm 31.75 31.75 31.75 44.45 44.45 44.45
Length (Dimension “I” above) inches 2.53 1.25 2.14 .47 1.53 2.53
mm 64.26 31.75 54.36 11.94 38.86 64.26
Length (Dimension “L” above) inches 5.08 5.99 6.89 5.22 6.27 7.28
mm 129.03 152.15 175.01 132.59 159.26 184.91
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 30.3 51.0 69.9 24.8 44.6 61.5
10 CFM in. H2O 27.9 44.2 59.9 23.6 41.0 55.8
20 CFM in. H2O 26.2 41.8 52.8 22.6 39.8 51.5
30 CFM in. H2O 23.6 35.9 44.1 21.5 35.8 46.0
40 CFM in. H2O 19.0 27.8 32.1 19.5 32.0 40.1
50 CFM in. H2O 13.3 16.6 18.1 17.9 28.0 34.2
60 CFM in. H2O 7.0 3.7 16.1 23.9 28.2
70 CFM in. H2O 3.7 13.8 17.9 19.6
80 CFM in. H2O 12.0 12.1 8.1
90 CFM in. H2O8.70
100 CFM in. H2O6.7
110 CFM in. H2O0
5.7” (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C
Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
*These part numbers are available through AMETEK Rotron distributors.
37
5.7” (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
Maximum Approximate Weight: 6 lbs.
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. R0097184.
Underwriters Laboratories, Inc. Qualified per UL507 under File E-94403. Canadian Standards Association Qualified per C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles.
Amp housing #1-480763-0 (to be supplied by customer), mates with post header assembly.
IEC 801 testing has been completed, and specific data can be provided upon request.
Mating harness available upon request. Refer to (page 84) for specific part numbers.