www.tracopower.com Page 2
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current (no load) 12 V in models 30 mA typ.
24 Vin models 20 mA typ.
48 Vin models 10 mA typ.
Input current (full load) 12 V in ; 3.3 Vout models: 915 mA typ.
12 Vin; 5 & ±5 Vout models: 1080 mA typ.
12 Vin; other output models: 1045 mA typ.
24 Vin; 3.3 Vout models: 435 mA typ.
24 Vin; 5 & ±5 Vout models: 530 mA typ.
24 Vin; other output models: 510 mA typ.
48 Vin; 3.3 Vout models: 215 mA typ.
48 Vin; 5 & ±5 Vout models: 260 mA typ.
48 Vin; other output models: 250 mA typ.
Start-up voltage / 12 Vin models 8.5 VDC / 8 VDC
under voltage shut down 24 Vin models 16.5 VDC / 16 VDC
48 Vin models 32.5 VDC / 32 VDC
Surge voltage 12 Vin models 25 V max.
(1 sec. max.) 24 Vin models 50 V max..
48 Vin models 100 V max.
Reverse voltage protection 1.0 A max.
Conducted noise (input) EN 55022 level A, FCC part 15, level A
Output Specifications
Voltage set accuracy ± 1 %
Regulation – Input variation Vin min. to V in max. ± 0.3 % max.
– Load variation 10 – 90 %
– single output models ± 0.5 % max.
– dual output models balanced load ± 1 % max.
– dual output models unbalanced load ± 3 % max.
Ripple and noise (20 MHz Bandwidth) 50 mVpk-pk max.
Temperature coefficient ± 0.02 % / °C
Output current limitation >110% of Iout max., constant current
Short circuit protection Hiccup mode, indefinite (automatic recovery)
Capacitive load – single output models 2200 µF max.
– dual output models 470 µF max.
General Specifications
Temperature ranges – Operating – 40 °C ... + 75 °C (no derating)
– Case temperature + 95 °C max.
– Storage – 40 °C ... + 125 °C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217 E) >1 Mio. h @ + 25 °C
Isolation voltage Input/Output 1‘500 VDC
Isolation capacity Input/Output 120 pF typ
Isolation resistance Input/Output (500 VDC) > 1‘000 M Ohm
DC/DC Conver ter
TEN 10 Series 10 Watt