Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog. Use the Interactive Catalog to access the most complete and up-to-date information available. The Interactive Catalog provides an extensive collection of product specifications, application data, and technical literature that can be searched based on criteria you select. Sensing and Control Interactive Catalog... Click this icon to try the Interactive Catalog. This PDF catalog information was published in November 2000. Sensing and Control Honeywell Inc. 11 West Spring Street Freeport, IL 61032 www.honeywell.com/sensing Limit and Enclosed Switches Weather-Sealed Explosion-Proof Switches FEATURES 1 Sealing - applicable portions of NEMA 1, 3, 4, 4X, 6, 6P, 7, 9, and 13 1 Watertight and dusttight for outdoor use 1 4-20 mA analog output available 1 UL Listed, file #E14274 1 Analog UL file #E68247 1 CSA Certified, file #LR57324 1 Rugged cast aluminum housing 1 Pretravel, overtravel, and actuating sequence can be field adjusted without tools (all basics individually) 1 Rotary types convert in seconds to clockwise, counterclockwise, or bothway operation CX switches are built especially for outdoor use in hazardous atmospheres. These enclosures are constructed to withstand the pressure of an internal explosion. Flame paths cool the exploded gases to a point less than the lowest safe operating temperature of the surrounding gas. O-ring seals make the enclosure weatherproof but are outside of required flame paths so explosion proof requirements are maintained. NEMA standards: 1, 3, 4, 4X, 6, 6P, 7, 9 and 13. UL listed: Class I, Div. 1, Groups B (14CX, 16CX, 24CX, 26CX, 36CX, and 84CX only), C and D; and Class II, Div. 1, Groups E, F and G. CSA certified: Class I, Div. 1, Groups B (14CX, 16CX, 24CX, 26CX, 36CX and 84CX only), C and D; and Class II, Groups E, F and G. For rapid response - off the shelf service, all bold face listings are normally stocked items. Analog output: either resistive or 4-20 mA is available. Operating temperature range is - 25 to +85C (-13 to 185F). Limit/Enclosed ROTARY ACTUATED SWITCHES CX Series ORDER GUIDE As factory assembled, all basic switches operate on clockwise and counterclockwise rotation. Actuating mechanism can be field adjusted for CW or CCW operation only. No tools are required. Catalog Listings Shaft Restoring Force To Center Short housing Description1 With W/O2 Housing Size Basic Switch(es)2 Electrical Ratings Short Short Standard Standard BZ(1) BZ(2) BZ(3) BZ(4) A A A A Short Short BA(1) BA(2) B B 15 amp. SPDT. 11CX1 11CX2 21CX4 11CX12 21CX13 21CX14 20 amp. SPDT. 12CX1 12CX2 12CX12 Standard BA(4) B Also UL listed for Class I. Group B (hydrogen atmospheres). 10 amp. DPDT. 14CX1 24CX2 14CX11 24CX12 24CX13 Short Standard Standard DT(1) DT(2) DT(3) C C C Actuators are not included with switch. Order them separately. Also UL listed for Class I, Group B (hydrogen atmospheres). 1 amp, SPDT. 16CX2 26CX4 16CX1 16CX12 26CX14 16CX11 Short Standard Short HS(2) HS(4) HS(1) D D D ROTARY LEVERS Analog position sensing.* Current output (4-20 mA). -- -- 18CX10 281CX12 284CX12 Short Standard Standard None BZ(2) DT(2) -- A C 1 amp, SPDT with gold contacts. 1172CX2 1172CX12 Short BZ(2) F 22CX4 Standard housing Lever Type Catalog Listing 1.5 in. lever, no roller .75 in. roller, front .75 in. roller, back LSZ51 LSZ51A LSZ51C 1.5-3.5 in. adjustable lever .75 in. roller 1.0 in. roller 1.5 in. roller LSZ52C LSZ52J LSZ52K 1.5 in. yoke roller .75 in. rollers, back .75 in. rollers, each side LSZ53S LSZ53E 5 in. rod lever Hub only LSZ54M LSZ54 1.5 in. offset lever, no roller .75 in. roller, back .75 in. roller, front LSZ55 LSZ55A LSZ55C * Where noted, BZ basic switches are 15 amp, SPDT; DT basic switchs are 10 amp DPDT. Refer to next page for analog position sensing specifications. MOUNTING HOLES Add the letter A to listings with side mounting holes tapped 5/16-18(8). Example: 11CX2A Add the letter B to listings with thru mounting holes tapped 3/8-24(4). Example: 11CX2B. Basic switches operate nearly simultaneously in multiple switch devices. 2 Shafts of devices without shaft restoring force can be rotated through 360. 1 Basic switches will be in operated mode through two 105 sections. Eight side mounting holes can be tapped 5/16N-18. Rollers are nylon. Non-sparking rollers must be used in hazardous locations. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A127 Limit and Enclosed Switches Weather-Sealed Explosion-Proof Switches CX Series REPLACEMENT BASIC SWITCH ASSEMBLIES These assemblies are factory adjusted to the same operating characteristics as a new CX switch. They include components subject to mechanical or electrical wear: basic switches, cam wheels and followers, and springs. ELECTRICAL RATINGS Circuitry Electrical Ratings A BZ Single-Pole Double-throw UL/CSA Rating: L96 15 amps, 120, 240 or 480 VAC, ind. and res. 18 Hp, 120 VAC; 14 Hp, 240 VAC. .5 amp, 125 VDC, .25 amp, 250 VDC., res. B BA Single-Pole Double-throw UL/CSA Rating: L23 20 amps, 120, 240 or 480 VAC, ind. and res. 1 Hp, 120 VAC; 2 Hp, 240 VAC. .5 amp, 125 VDC, .25 amp, 250 VDC res. C DT Double-pole Double-throw UL/CSA Rating: L59 10 amps, 120 or 240 VAC, ind. and res. .3 amp, 125 VDC, .15 amp, 250 VDC, res. D HS Single-Pole Double-throw UL/CSA Rating: L22 1 amp, 120 VAC, ind. and res. F BZ (Gold Contact) Single-Pole Double-throw To order, change the first number in the complete switch catalog listing to 9 for rotary switches and 10 for plunger switches with short housings. Example: Rotary switch 12CX5 Replacement J 92CX5 Plunger switch 36CX2 Replacement J 106CX2 Note: Basic switch assemblies for rotary actuated switches, with or without shaft restoring force, will be the same. For example: 11CX1 and 11CX11 use 91CX1. UL/CSA Rating: L22 1 amp, 125 VAC ANALOG POSITION SENSING SPECIFICATIONS Current Output (4-20 mA) Replacement PC Board Voltage compliance range: 12.5 to 40 VDC Maximum load resistance: RL, Max,-V Supply - 12.5 20 mA Current signal output: 4-20 mA Span: Adjustable from 15 to 90 of angular rotation. Null: 4 mA position may be set at any angular position. For current output devices 15PA261-CX OPERATING CHARACTERISTICS (All CX Switches) Rotary Actuation Plunger Actuation Basic Switch Type BZ BA DT HS Pretravel (max.)* 15 15 30 30 Differential Travel (max.) 10 10 25 20 .04 in./1.0 mm Overtravel (min.)* 90 90 75 75 .19 in./4,75 mm Operating Torque (max.) Operating Force (max.) BZ BA HS .10 in./2,5 mm 11.1 in. lb./1,25 Nm -- -- 8.82 lb./39,2 N LOW TEMPERATURE SWITCHES Add the letter C to listings for low temperature versions. Example: 21CX14C - 40F (- 40C) Rotary 36CX2C - 35F (- 37C) Plunger * May be modified in field to suit application requirements. N J Newtons Nm J Newton meters A128 Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Limit and Enclosed Switches Weather-Sealed Explosion-Proof Switches 80CX SWITCHES ALSO WITHSTAND CORROSIVE ENVIRONMENTS 80CX switches have rugged bronze housings which are resistant to salt water and other corrosive environments. They comply with the NEMA 4X requirement for protection against corrosion, in addition to NEMA enclosure standards met by other CX switches. O-ring seals make the enclosure weather-proof, but are outside of required flame paths so explosion-proof requirements are maintained. CX Series STAINLESS STEEL LEVER ACTUATORS These levers match the corrosion resistance of the 80CX housing. Non-sparking rollers must be used in hazardous locations. ORDER GUIDE STAINLESS STEEL LEVERS WITH NYLON ROLLERS Std. Roller Lever Radius (In.) Width In. Catalog Listing 1.5 .75 .25 LS2Z51A 1.5 .75 .25 LS2Z51 1.5-3.5 .75 .25 LS2Z52A Std. Lever w/o roller Adjustable Radius Dia. In. Limit/Enclosed Note: Refer to page A36 for lever dimensions. ROTARY ACTUATED SWITCHES ORDER GUIDE As factory assembled, all basic switches operate on clockwise or counterclockwise rotation. Actuating mechanism can be field adjusted for CW or CCW operation only. No tools are required. Catalog Listings Shaft Restoring Force To Center Actuators are not included with switches. Order them separately. MOUNTING HOLES Add the letter A to listings with side mounting holes tapped 5/16-18(8). Example: 82CX2A Add the letter B to listings with thru mounting holes tapped 3/8-24(4). Example: 81CX2B. Electrical Ratings Page A109 With Without2 15 amp. SPDT 81CX1 81CX2 81CX4 81CX11 81CX12 81CX14 Standard Standard Standard BZ(1) BZ(2) BZ(4) A A A 20 amp. SPDT 82CX2 82CX4 82CX12 82CX14 Standard Standard BA(2) BA(4) B B Also UL listed for Class I, Group B (hydrogen atmospheres). 10 amp. DPDT 84CX2 84CX12 Standard DT(2) C Description1 80CX switches available with standard housing only. Basic Switch(es) Housing Size Notes: Refer to page A127. MODIFIED SHAFT ENABLES DIRECT COUPLING CX switches are available with a 38 inch diameter by 34 inch long flatted shaft which conforms to standard NEMA motor shaft specifications. It accepts commercially available shaft couplers, permitting easy, direct coupling to most equipment actuators. MOUNTING BRACKET An aluminum mounting bracket is available for adapting CX switches to existing 2-hole mounting arrangements. To order, specify Catalog Listing 15PA148- CX. 15PA148-CX To specify a ``direct-couple'' CX switch, add -DO1 to catalog listings shown in the order guides, i.e. 11CX12-DO1. Pricing is the same as for unmodified versions. Flatted Shaft Version Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A129 Limit and Enclosed Switches Weather-Sealed Explosion-Proof Switches CX Series MOUNTING DIMENSIONS (For reference only) ROTARY Short housing PLUNGER Standard housing Short housing Standard housing THESE HOLES NOT FURNISHED ON 80CX SERIES LSZ52 LEVER ACTUATORS LSZ51 LSZ55 Front mounting Back mounting Front mounting Back mounting LSZ53 LSZ54 Both rollers Front mounting See order guides for roller dimensions. A130 Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada