If you need detailed product information, or help choosing the right
product for your application, see our Interactive Catalog. Use the
Interactive Catalog to access the most complete and up-to-date
information available.
The Interactive Catalog provides an extensive collection of product
specifications, application data, and technical literature that can be
searched based on criteria you select.
This PDF catalog information was published in November 2000.
Sensing and Control
Honeywell Inc.
11 West Spring Street
Freeport, IL 61032 www.honeywell.com/sensing
Sensing and Control
Interactive
Catalog...
Click this icon to try
the Interactive Catalog.
Interactive Catalog Supplements Catalog PDFs
Limit and Enclosed Switches CX Series
Weather-Sealed Explosion-Proof Switches
Honeywell1Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA127
FEATURES
1Sealing - applicable portions of NEMA 1,
3, 4, 4X, 6, 6P, 7, 9, and 13
1Watertight and dusttight for outdoor use
14-20 mA analog output available
1UL Listed, file #E14274
1Analog UL file #E68247
1CSA Certified, file #LR57324
1Rugged cast aluminum housing
1Pretravel, overtravel, and actuating
sequence can be field adjusted without
tools (all basics individually)
1Rotary types convert in seconds to
clockwise, counterclockwise, or both-
way operation
CX switches are built especially for outdoor
use in hazardous atmospheres. These en-
closures are constructed to withstand the
pressure of an internal explosion. Flame
paths cool the exploded gases to a point
less than the lowest safe operating temper-
ature of the surrounding gas.
O-ring seals make the enclosure weather-
proof but are outside of required flame paths
so explosion proof requirements are main-
tained.
Analog output: either resistive or 4-20 mA is
available.
Operating temperature range is –25°to
+85°C (–13°to 185°F).
NEMA standards: 1, 3, 4, 4X, 6, 6P, 7, 9 and
13.
UL listed: Class I, Div. 1, Groups B (14CX,
16CX, 24CX, 26CX, 36CX, and 84CX only), C
and D; and Class II, Div. 1, Groups E, F and
G. CSA certified: Class I, Div. 1, Groups B
(14CX, 16CX, 24CX, 26CX, 36CX and 84CX
only), C and D; and Class II, Groups E, F and
G.
For rapid response – off the shelf service,
all bold face listings are normally stocked
items.
ROTARY ACTUATED SWITCHES
Short housing
Standard housing
Actuators are not included with switch. Or-
der them separately.
ROTARY LEVERS
Catalog
Lever Type Listing
1.5 in. lever, no roller LSZ51
.75 in. roller, front LSZ51A
.75 in. roller, back LSZ51C
1.5-3.5 in. adjustable lever
.75 in. roller LSZ52C
1.0 in. roller LSZ52J
1.5 in. roller LSZ52K
1.5 in. yoke roller
.75 in. rollers, back LSZ53S
.75 in. rollers, each side LSZ53E
5 in. rod lever LSZ54M
Hub only LSZ54
1.5 in. offset lever, no roller LSZ55
.75 in. roller, back LSZ55A
.75 in. roller, front LSZ55C
Rollers are nylon. Non-sparking rollers must
be used in hazardous locations.
ORDER GUIDE
As factory assembled, all basic switches
operate on clockwise and counterclockwise
rotation. Actuating mechanism can be field
adjusted for CW or CCW operation only. No
tools are required.
Catalog Listings
Shaft Restoring
Force To Center
Housing Basic Electrical
Description1With W/O2Size Switch(es)2Ratings
15 amp. SPDT.11CX1 ShortBZ(1)A
11CX211CX12ShortBZ(2)A
21CX13StandardBZ(3)A
21CX4 21CX14 Standard BZ(4) A
20 amp. SPDT.12CX1 ShortBA(1)B
12CX2 12CX12 Short BA(2) B
22CX4 StandardBA(4)B
Also UL listed for Class I. 14CX1 14CX11 Short DT(1) C
Group B (hydrogen atmospheres).24CX224CX12StandardDT(2)C
10 amp. DPDT. 24CX13StandardDT(3)C
Also UL listed for 16CX2 16CX12 Short HS(2) D
Class I, Group B 26CX4 26CX14 Standard HS(4) D
(hydrogen atmospheres). 16CX1 16CX11 Short HS(1) D
1 amp, SPDT.
Analog position sensing.* 18CX10 Short None
Current output (4-20 mA). 281CX12 Standard BZ(2) A
284CX12 Standard DT(2) C
1 amp, SPDT with1172CX21172CX12ShortBZ(2)F
gold contacts.
* Where noted, BZ basic switches are 15 amp, SPDT; DT basic switchs are 10 amp DPDT. Refer to next page for
analog position sensing specifications.
1Basic switches operate nearly simultane-
ously in multiple switch devices.
2Shafts of devices without shaft restoring
force can be rotated through 360°.
Basic switches will be in operated mode
through two 105°sections.
Eight side mounting holes can be tapped
5/16N-18.
MOUNTING HOLES
Add the letter A to listings with side mount-
ing holes tapped 5/16-18(8).
Example: 11CX2A
Add the letter B to listings with thru mount-
ing holes tapped 3/8-24(4).
Example: 11CX2B.
Limit/ Enclosed
Limit and Enclosed Switches CX Series
Weather-Sealed Explosion-Proof Switches
A128Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
ELECTRICAL RATINGS
Circuitry Electrical Ratings
A UL/CSA Rating: L96
BZ 15 amps, 120, 240 or 480 VAC, ind. and res.
Single-Pole 18Hp, 120 VAC; 14Hp, 240 VAC.
Double-throw .5 amp, 125 VDC, .25 amp, 250 VDC., res.
B UL/CSA Rating: L23
BA 20 amps, 120, 240 or 480 VAC, ind. and res.
Single-Pole 1 Hp, 120 VAC; 2 Hp, 240 VAC.
Double-throw .5 amp, 125 VDC, .25 amp, 250 VDC res.
C UL/CSA Rating: L59
DT 10 amps, 120 or 240 VAC, ind. and res.
Double-pole .3 amp, 125 VDC, .15 amp, 250 VDC, res.
Double-throw
D UL/CSA Rating: L22
HS 1 amp, 120 VAC, ind. and res.
Single-Pole
Double-throw
F UL/CSA Rating: L22
BZ (Gold Contact) 1 amp, 125 VAC
Single-Pole
Double-throw
ANALOG POSITION SENSING SPECIFICATIONS
Current Output (4-20 mA)Replacement PC Board
Voltage compliance range: 12.5 to 40 VDC
Maximum load resistance:
RL, Max,–V Supply - 12.5
20 mA
Current signal output: 4-20 mA
Span: Adjustable from 15°to 90°of angular
rotation.
Null: 4 mA position may be set at any angular
position.
For current output devices 15PA261-CX
OPERATING CHARACTERISTICS (All CX Switches)
Rotary Actuation Plunger Actuation
Basic Switch Type BZ BA DT HS BZ BA HS
Pretravel (max.)* 15°15°30°30°.10 in./2,5 mm
Differential Travel (max.) 10°10°25°20°.04 in./1.0 mm
Overtravel (min.)* 90°90°75°75°.19 in./4,75 mm
Operating Torque (max.) 11.1 in. lb./1,25 Nm
Operating Force (max.) 8.82 lb./39,2 N
REPLACEMENT BASIC SWITCH
ASSEMBLIES
These assemblies are factory adjusted to
the same operating characteristics as a new
CX switch. They include components sub-
ject to mechanical or electrical wear: basic
switches, cam wheels and followers, and
springs.
To order, change the first number in the
complete switch catalog listing to 9 for ro-
tary switches and 10 for plunger switches
with short housings.
Example:
Rotary switch 12CX5
Replacement J92CX5
Plunger switch 36CX2
Replacement J106CX2
Note: Basic switch assemblies for rotary ac-
tuated switches, with or without shaft restor-
ing force, will be the same.
For example:
11CX1 and 11CX11 use 91CX1.
* May be modified in field to suit application requirements.
N JNewtons
Nm JNewton meters
LOW TEMPERATURE SWITCHES
Add the letter C to listings for low temperature versions.
Example: 21CX14C –40°F (–40°C) Rotary
36CX2C –35°F (– 37°C) Plunger
* May be modified in field to suit application requirements.
N JNewtons
Nm JNewton meters
LOW TEMPERATURE SWITCHES
Add the letter C to listings for low temperature versions.
Example: 21CX14C –40°F (–40°C) Rotary
36CX2C –35°F (– 37°C) Plunger
Limit and Enclosed Switches CX Series
Weather-Sealed Explosion-Proof Switches
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA129
80CX SWITCHES ALSO WITHSTAND
CORROSIVE ENVIRONMENTS
80CX switches have rugged bronze hous-
ings which are resistant to salt water and
other corrosive environments. They comply
with the NEMA 4X requirement for protec-
tion against corrosion, in addition to NEMA
enclosure standards met by other CX
switches. O-ring seals make the enclosure
weather-proof, but are outside of required
flame paths so explosion-proof require-
ments are maintained.
STAINLESS STEEL LEVER ACTUATORS
These levers match the corrosion resistance of the 80CX housing. Non-sparking rollers
must be used in hazardous locations.
ORDER GUIDE STAINLESS STEEL LEVERS WITH NYLON ROLLERS
Std. Roller Lever
Radius (In.) Dia. In. Width In. Catalog Listing
1.5 .75 .25 LS2Z51A
Std. Lever w/o roller 1.5 .75 .25 LS2Z51
Adjustable Radius
1.5-3.5 .75 .25 LS2Z52A
Note: Refer to page A36 for lever dimensions.
ROTARY ACTUATED SWITCHES
80CX switches available with standard
housing only.
Actuators are not included with switches.
Order them separately.
MOUNTING HOLES
Add the letter A to listings with side
mounting holes tapped 5/16-18(8).
Example: 82CX2A
Add the letter B to listings with thru
mounting holes tapped 3/8-24(4).
Example: 81CX2B.
ORDER GUIDE
As factory assembled, all basic switches
operate on clockwise or counterclockwise
rotation. Actuating mechanism can be field
adjusted for CW or CCW operation only. No
tools are required.
Catalog Listings
Shaft Restoring Electrical
Force To Center Housing Basic Ratings
Description1With Without2Size Switch(es) Page A109
15 amp. SPDT 81CX1 81CX11 Standard BZ(1) A
81CX2 81CX12 Standard BZ(2) A
81CX481CX14StandardBZ(4)A
20 amp. SPDT82CX282CX12StandardBA(2)B
82CX482CX14StandardBA(4)B
Also UL listed for Class I,84CX2 84CX12StandardDT(2)C
Group B (hydrogen
atmospheres). 10 amp. DPDT
Notes: Refer to page A127.
MODIFIED SHAFT ENABLES
DIRECT COUPLING
CX switches are available with a 38inch
diameter by 34inch long flatted shaft which
conforms to standard NEMA motor shaft
specifications. It accepts commercially
available shaft couplers, permitting easy,
direct coupling to most equipment actua-
tors.
To specify a ‘‘direct-couple’’ CX switch, add
-DO1 to catalog listings shown in the order
guides, i.e. 11CX12-DO1. Pricing is the same
as for unmodified versions.
Flatted
Shaft
Version
MOUNTING BRACKET
An aluminum mounting bracket is available
for adapting CX switches to existing 2-hole
mounting arrangements.
To order, specify Catalog Listing 15PA148-
CX.
15PA148-CX
Limit/ Enclosed
Limit and Enclosed Switches CX Series
Weather-Sealed Explosion-Proof Switches
A130Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
MOUNTING DIMENSIONS (For reference only)
ROTARY Short housing Standard housing
PLUNGER Short housing Standard housing
THESE HOLES NOT FURNISHED ON 80CX SERIES
LEVER ACTUATORS
LSZ51 LSZ55
LSZ52
Front
mounting
Back
mounting
Front
mounting
Back
mounting
LSZ53
LSZ54
Both rollers
Front mounting