Solid-State Timer H3CA 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat cycle, Signal Interval/OFF-delay, Signal-OFF delay (I and II), Interval, Cycle and Signal ON-delay/OFF-delay Selectable no-voltage start, reset, gate and check inputs expand capabilities Time remaining LCD bar graph and LCD output status indicator Panel mounting adapters, sockets, and accessories may be ordered separately Ordering Information TIMERS Add the supply voltage to the part number when you order ON-delay only timers H3CA-8 and H3CA-8H. For example, H3CA-8H-AC/100/110/120. Timing function Contact Time limit type Instantaneous Terminal form Part number Supply AC voltages DC 8 field-selectable functions SPDT SPDT - - 11-pin round socket Front mounted screw terminals H3CA-A H3CA-FA 24 to 240 V, 50/60 Hz or 12 to 240 V ON-delay only SPDT SPDT 8-pin round socket DPDT - H3CA-8H H3CA-8 Specify 24 V, 100/110/120 V, or 200/220/240 V; 50/60 Hz Specify 12 V, 24 V, 48 V or 110 V ACCESSORIES Description Sockets H3CA-A timer H3CA-8, H3CA-8H timers Panel mounting adapters Protective cover Mounting track H3CA 1 Bottom surface or track mounting, top screw terminals Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals Bottom surface or track mounting, top screw terminals Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals Fits behind panel, ideal for side by side installation. Use P3G- sockets. Installs through panel front; timer face fits bezel, rear of timer clips to adapter. Use P3G- sockets. Fits 65-66 mm (2.56 - 2.59 in) x 52-53 (2.04 x 2.09 in) panel cutout. Charcoal gray face plate measures 88 H x 58 W mm (3.46 x 2.28 in). Installs through panel front; timer face fits bezel, rear of timer clips to adapter. Use P3G- sockets. Fits 55 x 45 mm (2.17 x 1.77 in) panel cutout. Charcoal gray face plate measures 58 H x 50 W mm (2.28 x 1.97 in). Hard plastic cover; not for use with Y92F-70 or Y92F-71 panel adapters. Soft plastic cover; not for use with Y92F-70 or Y92F-71 panel adapters. DIN rail, 50 cm (1.64 ft) length DIN rail, 1 m (3.28 ft) length End plate Spacer Part number P2CF-11 P3GA-11 P2CF-08 P3G-08 Y92F-30 Y92F-70 Y92F-71 Y92A-48B Y92A-48D PFP-50N PFP-100N PFP-M PFP-S H3CA H3CA RANGE AND OPERATION MODE SELECTION Operation mode selector* Time unit selector Time unit Timing range 0.1 s s 0.1 m m 0.1 h h 10 h 0.1 to 99.9 seconds 1 to 999 seconds 0.1 to 99.9 minutes 1 to 999 minutes 0.1 to 99.9 hours 1 to 999 hours 10 to 9990 hours Time setting switches Note: Mode A B C D E F G H Operation ON-delay Repeat cycle Signal Interval/OFF-delay Signal OFF-delay I Interval Cycle Signal ON-delay/OFF-delay Signal OFF-delay II *Operation mode selector not included with ON-delay only models. Specifications Part number Supply voltage AC DC Operating voltage Power consumption AC DC Timing functions Start, reset, gate inputs Time limit Control Type output Instantaneous Max. load Min. load Repeat accuracy Setting error Resetting system Resetting time Indicators Materials Mounting Connections Weight Approvals Operating ambient temperature Humidity Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Variation due to voltage change Variation due to temperature change Insulation resistance Dielectric strength Service life 2 Mechanical Electrical H3CA-A H3CA-FA 24 to 240 V, 50/60 Hz 12 to 240 V H3CA-8H H3CA-8 24 V, 100/110/120 V, 200/220/240 V; 50/60 Hz 12 V, 24 V, 48 V, 110 V, (permissible ripple factor: 20% max. using single-phase, fullwave rectified power sources) 90 to 110% of rated voltage 3 VA 10 VA 3W 2W 8 field-selectable modes: ON-delay, Repeat ON-delay only cycle, Signal Interval/OFF-delay, Signal ON-/ OFF-delay, Signal OFF-delay (I and II), Interval and Cycle No voltage No voltage - - SPDT SPDT DPDT - SPDT - 3 A, 250 VAC (p.f. = 1) 10 mA, 5 VDC 0.3%, 0.05 sec (includes variation due to voltage and temperature changes) 0.5%, 0.05 sec Power-OFF, external and self-reset Power-OFF 0.5 sec max. 0.1 sec max. Time Remaining (LCD bar graph), Output Status (LCD message) Plastic case Panel, track, surface 11-pin round socket Terminal screws 8-pin round socket 110 g (3.9 oz) 190 g (6.7 oz) 110 g (3.9 oz) UL/CSA/SEV -10 to 55C (14 to 131F) 35 to 85% RH 10 to 55 Hz; 0.75 mm (0.03 in) double amplitude 10 to 55 Hz; 0.5 mm (0.02 in) double amplitude 100 G 10 G See "Repeat Accuracy" See "Repeat Accuracy" 100 M min. at 500 VDC 2,000 VAC, 50/60 Hz for 1 minute between current-carrying and non-current-carrying parts and between contact and control circuit 1,000 VAC, 50/60 Hz for 1 minute between non-continuous contacts 10 million operations minimum (under no load, at 1,800 operations/hour) 100,000 operations minimum at maximum ratings H3CA H3CA Engineering Data Electrical operations (thousands) ELECTRICAL SERVICE LIFE 10,000 7,000 5,000 3,000 1,000 700 24 VDC L/R = 7 ms 500 24 VDC p.f.= 1 300 100 70 50 250 VAC p.f.= 1 250 VAC p.f. = 0.4 0 1 2 3 Load current Timing Charts In the schematic diagrams, each thick line indicates the external wiring necessary for the selected operation. H3CA-A, H3CA-FA Mode A ON-Delay Power-ON Start/Power-OFF Reset The start terminals are connected. Timing starts when power is applied. The output is energized when the accumulated time equals the set time. The output remains energized until power is disconnected or a reset input is applied. Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Time-out indicator Remaining time indicator (AC/DC) Power t = set time Rt = reset time t-a = less than set time Signal Start Power is applied continuously. Timing starts at the leading edge of the start input. The output is energized when the accumulated time equals the set time. Subsequent start signals during or after timing will not be accepted. The output relay will remain energized until a reset input is applied or power is interrupted. Start signal Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Reset signal Time-out indicator Remaining time indicator (AC/DC) Power t = set time t-a = less than set time 3 H3CA H3CA In the schematic diagrams, each thick line indicates the external wiring necessary for the selected operation. Mode B Repeat Cycle Signal Start Power is continuously applied. The OFF/ON cycle is initiated at the leading edge of the start input. The output relay will be OFF for the set time and then ON for the set time. This cycle will be repeated until a reset input is applied or power is disconnected. Start signal Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Reset signal Time-out indicator Remaining time indicator (AC/DC) Power t = set time t-a = less than set time t = set time t-a = less than set time t = set time t-a = less than set time Power-ON Start/Power-OFF Reset The start terminals are connected. Timing starts when power is applied. The output relay will be OFF for the set time and then ON for the set time. This cycle will be repeated until a reset input is applied or power is disconnected. Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Time-out indicator (AC/DC) Mode C Remaining time indicator Power Signal Interval/OFF-Delay Power is continuously applied. Timing begins on both the leading and trailing edges of the start input. The output relay is energized during timing. Once the timer has timed out from the trailing edge, it resets and is ready for subsequent start inputs. Start signal Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Time-out indicator Remaining time indicator (AC/DC) Power 4 H3CA H3CA In the schematic diagrams, each thick line indicates the external wiring necessary for the selected operation. Mode D Signal OFF-Delay (I) Power is continuously applied. The output relay is energized at the leading edge of the start input. Timing starts at the trailing edge of the start input. The output relay is de-energized when the accumulated time equals the set time. Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Start signal Control 9 - 11 output NO (15-18) Time-out indicator (AC/DC) Mode E Remaining time indicator Power t = set time t-a = less than set time t = set time t-a = less than set time t = set time t-a = less than set time Interval Signal Start Power is applied continuously. Timing starts at the leading edge of the start input. The output relay is only energized during timing. The timer is reset when power is disconnected or a reset input is applied. Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Start signal Reset 3-7 (X-B1) Reset signal Control 9 - 11 output NO (15-18) Time-out indicator Remaining time indicator (AC/DC) Power Power-ON Start/Power-OFF reset The start terminals are connected. Timing starts when power is applied. The output relay is only energized during timing. The timer is reset when power is disconnected or a reset input is applied. Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Time-out indicator (AC/DC) Remaining time indicator Power 5 H3CA H3CA In the schematic diagrams, each thick line indicates the external wiring necessary for the selected operation. Mode F Cycle One-Shot Power-ON Short/Power-OFF Reset The start terminals are connected. Timing starts when power is applied. The output relay will be OFF for the set time and then ON for the set time. The timer is reset when power is disconnected or a reset input is applied. Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Time-out indicator (AC/DC) Remaining time indicator Power t = set time t-a = less than set time t = set time t-a = less than set time t = set time t-a = less than set time Signal Start Power is applied continuously. The OFF/ON cycle is initiated at the leading edge of the start input. The output relay will be OFF for the set time and then ON for the set time. The timer is reset when power is disconnected or a reset input is applied. Start signal Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Reset signal Time-out indicator Remaining time indicator (AC/DC) Mode G Power Signal ON-delay/OFF-delay Power is continuously applied. Timing begins on both the leading and trailing edges of the start input. The output relay is energized when the accumulated time from the leading edge equals the set time. It is also energized for the set amount of time from the trailing edge of the start input. Start signal Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Time-out indicator Remaining time indicator (AC/DC) 6 Power H3CA H3CA In the schematic diagrams, each thick line indicates the external wiring necessary for the selected operation. Mode H Signal OFF-Delay (II) Power is continuously applied. Timing starts at the trailing edge of the start input. The output relay is energized during timing. Start signal Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Reset 3-7 (X-B1) Control 9 - 11 output NO (15-18) Time-out indicator (AC/DC) Remaining time indicator Power t = set time t-a = less than set time H3CA-8 Power Timed contact Timed contact Power circuit (7 - 2) Time-limit contact NC Time-limit contact NO (1 - 4) (1 - 3) Time-limit contact NC (8 - 5) Time-limit contact NO (8 - 6) Remaining time indicator Time-out indicator t = set time Rt = reset time t = set time Rt = reset time H3CA-8H Power Instantaneous contact Timed contact Time-limit contact NC Time-limit contact NO (7 - 2) (8 - 5) (8 - 6) Instantaneous contact NC (1 - 4) Power circuit Instantaneous contact NO (1 - 3) Remaining time indicator Time-out indicator Dimensions Unit: mm (inch) Panel cutout TIMERS H3CA-A 11 5 6 89 (3.50) 78 63.7 45 (1.77) 0.7 13.6 44.8 (1.76) 48 (1.89) 48 (1.89) 75.4 (2.97) (1.97) 50 45 (1.77) 50 (1.97) Note: Recommended panel thickness is 1 to 3.2 mm. Panel cutout conforms to DIN 43700. 7 H3CA H3CA In the schematic diagrams, each thick line indicates the external wiring necessary for the selected operation. H3CA-FA 8.5 8.5 Mounting holes 5 7.5 7.5 60 (2.36) 35 75 58 (2.95) 35 (1.38) L Note: When mounting two or more timers next to one another, allow 10 mm (0.39 in) between timers (dimension L). 91 58 45 (1.77) 96 101 (3.98) H3CA-8, H3CA-8H 89 (3.50) 78 63.7 11 56 Panel cutout 0.7 13.6 44.8 (1.76) 48 (1.89) 45 (1.77) 50 (1.97) 45 (1.77) 50 (1.97) 75.4 (2.97) 48 (1.89) Note: Recommended panel thickness is 1 to 3.2 mm. Panel cutout conforms to DIN 43700. SOCKETS 11-Pin Sockets for H3CA-A P2CF-11 Bottom surface or track mounting socket Eleven M3.5 x 7.5 sems 3 4.5 7.8 Terminal arrangement Mounting holes Two 4.5 dia. socket mounting holes 74 max. (2.91) 4 35.4 (1.39) Two 4.5 dia. mounting holes 50 (1.97) max. 400.2 (1.57) 31.2 (1.23) max. (Top view) P3GA-11 Back Mounting Socket Terminal arrangement (1.007) 8 H3CA H3CA 8-Pin Sockets for H3CA-8, H3CA-8H P2CF-08 Bottom surface or track mounting Eight M3.5 x 7.5 sems 4.5 3 7.8 Terminal arrangement Mounting holes Two 4.5 dia. or two M4 socket mounting holes 70 (2.75) max. 35.4 (1.39) 400.2 Two 4.5 dia. mounting holes 50 (1.97) max. (Top view) 20 max. (0.79) P3G-08 Back mounting socket Terminal arrangement (1.77) (1.77) (Bottom view) (0.69) PANEL MOUNTING ADAPTERS For H3CA, H3CA-8, H3CA-8H Y92F-30 Mounting Adapter Adapter installs behind the panel. It is ideal for side by side installation. Use P3GA-11 or P3G-08 sockets. Panel cutout Mounting panel Y92F-30 15 0.5 R max. Socket 45 (1.77) 45 (1.77) 58 (2.28) Note: Recommended panel thickness is 1 to 3.2 mm. 48 (1.89) 11 91.4 (3.59) Y92F-70 Mounting Adapter Charcoal gray panel adapter installs through panel front. Timer fits bezel, rear of timer clips to adapter. Use P3GA-11 or P3G-08 sockets. Panel cutout Mounting panel Socket Two 4.5 diameter mounting holes for panel adapter 0.5 R max. 45 88 (3.46) 0.15 45 58 (2.28) 11 91.4 (3.59) Note: recommended panel thickness is 1 to 3.2 mm.. 9 H3CA H3CA Y92F-71 Mounting Adapter Charcoal gray panel adapter installs through panel front. Timer face fits bezel, rear of timer clips to adapter. Use P3GA-11 or P3G-08. Panel cutout Mounting panel 56 (2.2) Socket 55 (2.16) 68 (2.68) 58 45 (2.28) 45 (1.77) 0.5 R max. Note: Recommended panel thickness is 1 to 3.2 mm. 43 50 91.4 (3.59) 11 PROTECTIVE COVERS Y92A-48B Hard Plastic Cover Y92A-48D Soft Plastic Cover Hard plastic cover Y92A-48B and soft plastic cover Y92A-48D snap onto the front of the timer to protect against dust and water. The Y92A-48B hard plastic cover prevents accidental resetting. Y92A-48D soft plastic cover fits snugly over the front and allows settings to be changed. These covers are intended for use in areas where unusual service conditions do not exist. 50.5 (1.99) 50.5 (1.99) 16 (0.63 in) overall depth MOUNTING TRACK AND ACCESSORIES PFP-100N/PFP-50N DIN Rail PFP-M End Plate PFP-S Spacer Connections Part Input terminal numbers (no-voltage only) number Gate Start Reset Check COM H3CA-A 5 6 7 4 3 H3CA-FA D1 C1 B1 E1 X H3CA-8H - - - - - H3CA-8 10 - - - - - Power supply terminal numbers AC (common), DC- AC (hot), DC+ 2 10 A2 A1 2 7 2 7 Output terminal numbers Type COM Timed contact 11 Timed contact 15 Instantaneous 1 Timed contact 8 Timed contact 1 Timed contact 8 NC 8 16 4 5 4 5 NO 9 18 3 6 3 6 H3CA H3CA CONTACT SIGNAL INPUTS H3CA-A Input Signal Requirements Resistance Residual voltage Contact material 1 K max. 1 V max. when the contact makes Gold-plated contacts recommended H3CA-A * Start input contact between terminals 3 and 6. * Reset input contact between terminals 3 and 7. * Gate input contact between terminals 3 and 5. * Check input contact between terminals 3 and 4. H3CA-FA H3CA-FA * Start input contact between terminals X and C1. * Reset input contact between terminals X and B1. * Gate input contact between terminals X and D1. * Check input contact between terminals X and E1. * Reset * * input * * * * Check input Start input * * * Gate input * Power + - SOLID-STATE SIGNAL INPUTS Solid-State Inputs (Not Open Collector Type) Input Signal Requirements Input type Voltage when collector is OFF Saturated voltage when transistor is ON Collector current Input current between collector and base Resistance when transistor is ON Residual voltage when transistor is ON Resistance when transistor is OFF Proximity and photoelectric sensors often have NPN or PNP type solid-state output circuits and rated supply voltages ranging from 6 to 30 VDC. These signals are applied to the timer according to the diagram below. Open collector transistor 20 V min. 1 V max. 50 mA max. 0.5 A max. 1 K max. 1 V max. 200 K min. Solid-state circuit (proximity sensor, proximity sensor, etc.) (Connect Reset input between terminals 3 and 7, and Gate input between terminals 3 and 5.) H3CA-A and H3CA-FA Solid-state input terminal connections are the same as those for contact signal inputs. 0.1 mA Start input (Timer starts at Low level of this signal.) CUMULATIVE TIMING t1 + t2 = set time Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Gate 3-5 (X-D1) Reset 3-7 (X-B1) Control output NO 9 - 11 (15-18) Using the Gate Input with ON-Delay When the gate signal is closed, timing is temporarily stopped. When the gate signal opens, timing resumes at the point of interruption. The gate input terminal permits the timer to sum up times t1 and t2 as shown in the timing chart. +5 V Interruption 11 H3CA H3CA CHECK INPUT ON-Delay Operation When a no-voltage input signal is applied to the timer during the lapse of a set time, the remaining set time will become 0 and the timer will enter the next control state. Also, while the Check Signal is applied, the elapsed time measurement of the set time is not performed. The Check input is especially useful where ON-delay override may be desirable. t-a Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Check 3-4 (X-E1) Reset 3-7 (X-B1) Control output NO 9 - 11 (15-18) t - a = less than set time Repeat Cycle Operation The Check input signal in Repeat cycle mode allows the timer to be used like a binary flip-flop or alternating relay. Set an unattainable time, such as 999 hours. Apply the no-voltage Check input to shift output status from ON to OFF, or vice-versa. Jumper terminals 3 and 6 (X and C1) to short the start function. The Check input then controls the output relay like a flip-flop or alternating relay. This may be used to alternate wear on main and secondary equipment such as pumps. Power 2 - 10 (A1-A2) Start 3-6 (X-C1) Check 3-4 (X-E1) Reset 3-7 (X-B1) Control output NO 9 - 11 (15-18) t + set time t - a = less than set time Installation PROPER INPUT CONNECTIONS (H3CA-A, H3CA-FA) The neutral or common of the power supply is connected to terminal 2 (A2) of the timer. Terminal 10 (A1) should be connected to the "hot" or positive of the power supply. Do not apply voltage to Check, Gate, Start and Reset inputs. These are no-voltage type inputs. PROPER OUTPUT CONNECTIONS 2 (A2) Power supply AC or DC * Input contact H3CA-A (H3CA-FA) ** 4, 5, 6, 7 C, G, S, R 8 9 11 ......* * Load 10 (A1) Design your control circuit using the output relay contacts to switch the load. Never switch a load with the contact that is being used as an input signal. The timer's circuitry may be damaged. PARALLEL CONNECTIONS Parallel connection of two or more Omron Timers is possible as shown by the diagram to the right. This will allow the simultaneous start or restart of multiple timers using a single switch for the Start Input and a single switch for the Reset Input. Reset Start Com 8 9 2 1 11 6 5 Com 7 3 It is possible to wire only up to 4 timers in this manner. Wiring more than 4 results in poor performance due to excessive voltage drop. 10 8 3 9 1 H3CA-A Timer 7 4 2 12 6 5 4 11 10 H3CA-A Timer H3CA H3CA Operation SELECTING TIME RANGE Use the rightmost pushwheel switch to select the time range. Use the three center pushwheel switches to select the time setting between 000 and 999. For ranges with 0.1 time units, the decimal point is assumed to be between middle and right digits. Operation mode selector* Time unit selector Time unit Timing range 0.1 s s 0.1 m m 0.1 h h 10 h 0.1 to 99.9 seconds 1 to 999 seconds 0.1 to 99.9 minutes 1 to 999 minutes 0.1 to 99.9 hours 1 to 999 hours 10 to 9990 hours Time setting switches Note: *Operation mode selector not included with ON-delay timers. SELECTING OPERATION MODES (H3CA-A, H3CA-FA) The operation mode is selected by the leftmost pushwheel switch. Mode A B C D E F G H Operation ON-delay Repeat cycle Signal Interval/OFF-delay Signal OFF-delay I Interval Cycle Signal ON-delay/OFF-delay Signal OFF-delay II CAUTIONS Do not change the time unit or time range while the timer is in operation. Otherwise, the timer may malfunction or be damaged. Be sure to turn off the power supply to the timer before changing any of the selections. Mounting PANEL MOUNTING Using Y92F-30 Adapter Insert the timer through the panel cutout. Push the Y92F-30 adapter from the rear of the timer as far forward toward the panel as possible. Wire the P3G- socket, then push it onto the rear of the timer. Then, tighten the two retaining screws. To release the adapter, lift the tab at the rear of the adapter. Several timers may be mounted close together using Y92F-30 adapter as shown here. When mounting two or more timers in a vertical line, arrange the adapters so that their molded tabs are positioned on the right and left sides. When mounting two or more timers in a horizontal line, arrange the adapters so that their molded tabs are positioned on the top and bottom sides. Panel cutout for side-by-side mounting of two timers Molded tab Molded tab 13 H3CA H3CA Using Y92F-70 and Y92F-71 Adapters Install the H3CA timer, face first, into the back side of the Y92F-70 or Y92F-71 adapter so the bezel fits snugly. Be sure the retaining clips at the back of the adapter fit into the slots on either side of the timer. Compress the top and bottom tabs of the adapter then push the adapter through the front side of the panel cutout. Be sure the tabs extend after installation for a secure fit. To remove the timer from the adapter, unclip the two retaining clips at the back of the adapter. To remove the adapter and timer from the panel as a unit, compress the tabs behind the panel and push the unit out the front of the panel. Removal Installation Mounting tabs Panel Retaining clips for timer Mounting tabs TRACK MOUNTING H3CA-FA with Built-In Track Adapter Mounting Removal First hook part "A" on the rear of the timer onto an edge of the track. Then, press the timer in direction "B" until the latch on the bottom rear of the timer locks securely. Pull the latch "C" with a flat-blade screwdriver and remove the timer from the mounting track. P2CF- Socket For H3CA-A, H3CA-8 and H3CA-8H Mounting Removal The P2CF- socket has two hooks that secure the timer to the socket. Be sure to allow at least 20 mm (0.79 in) clearance above and below the socket to gain access and to release the hooks for servicing and maintenance. Insert timer into the socket. Latch hooks. Then clip rear of the socket to the track. Push the bottom onto the track until the latch hooks securely. Pull the latch on the socket with a flat-blade screwdriver and remove the timer and socket as one unit. NOTE: ALL DIMENSIONS ARE IN MILLIMETERS. To convert millimeters into inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC TI8 14 11/97 Specifications subject to change without notice. Printed in the U.S.A.