Technical Data 4399
Effective October 2017
Supersedes June 2017
Product features
•PolyTron™ radial leaded thru-hole PTC device
•Maximum 16 V
•Current ratings from 0.9 A to 15 A
•Fast time-to-trip
•Low resistance
•Halogen free, lead free, RoHS compliant
Applications
•Medical equipment
•Telecommunications
•White goods
•Computers and peripherals
Agency information
•cURus: Recognized Card: File E343021 (Ihold 3A-15 A)
•TUV File: J 50194729
Ordering information/
part number system
PTR016V
16 Volt DC radial leaded, PolyTron™ PTC devices
Pb
HALOGEN
HF
FREE
PT R 016V 0090 -TR
PolyTron™ PTC Device Series
Radial Leaded
Maximum Voltage
Current Holding (Ihold)
Packaging and Lead Type Code
Lead Codes: TR & BK - Straight Leads, TR1 & BK1 - Kinked Leads
TR & TR1 On Reels BK & BK1 In Poly Bags
• 0.9-1.60 A - 1000 devices
• 1.85-9.00 A - 500 devices
• 10.00-15.00 A - 250 devices
• 0.9-1.85 A - 3000 devices
• 2.5-4 A - 2500 devices
• 5-7 A - 1500 devices
• 8-15 A - 1000 devices
Ihold Itrip PdTime to Resistance (Ω) Agency
Catalog Vmax Imax
@ +23 °C @ +23 °C
Typ. Trip (Max.) Initial (R
i) Post Trip (R
1) Information
Number (Vdc)
(A) (A) (A)
(W)
(A) (sec)
Min. Max. Max. cURus TUV
PTR016V0090 16 40 0.90 1.80 0.60 8.00 1.20 0.070 0.120 0.180 X
PTR016V0110 16 40 1.10 2.20 0.70 8.00 2.30 0.050 0.095 0.140 X
PTR016V0135 16 40 1.35 2.70 0.80 8.00 4.50 0.040 0.074 0.120 X
PTR016V0160 16 40 1.60 3.20 0.90 8.00 9.00 0.030 0.061 0.110 X
PTR016V0185 16 40 1.85 3.70 1.00 8.00 10.00 0.030 0.051 0.090 X
PTR016V0250 16 40 2.50 5.00 1.20 8.00 40.00 0.020 0.036 0.070 X
PTR016V0300 16 100 3.00 5.10 2.30 15.00 1.00 0.038 0.065 0.098 X X
PTR016V0400 16 100 4.00 6.80 2.40 20.00 1.70 0.021 0.038 0.060 X X
PTR016V0500 16 100 5.00 8.50 2.60 25.00 2.00 0.010 0.023 0.034 X X
PTR016V0600 16 100 6.00 10.20 2.80 30.00 3.30 0.006 0.018 0.028 X X
PTR016V0700 16 100 7.00 11.90 3.00 35.00 3.50 0.006 0.013 0.020 X X
PTR016V0800 16 100 8.00 13.60 3.00 40.00 5.00 0.005 0.011 0.018 X X
PTR016V0900 16 100 9.00 15.30 3.30 45.00 5.50 0.005 0.009 0.014 X X
PTR016V1000 16 100 10.00 17.00 3.60 50.00 6.00 0.004 0.007 0.010 X X
PTR016V1100 16 100 11.00 18.70 3.70 55.00 7.00 0.003 0.006 0.009 X X
PTR016V1200 16 100 12.00 20.40 4.20 60.00 7.50 0.003 0.006 0.009 X X
PTR016V1300 16 100 13.00 22.10 4.60 65.00 8.50 0.002 0.006 0.008 X X
PTR016V1400 16 100 14.00 23.80 4.60 70.00 9.00 0.002 0.005 0.007 X X
PTR016V1500 16 100 15.00 25.50 4.60 75.00 10.00 0.002 0.005 0.007 X X
Notes: IIhold – Hold current: Maximum current device will pass without interruption in +23 °C still air.
Itrip – Trip current: Minimum current that will switch the device from low resistance to high resistance in +23 °C still air.
Vmax: Maximum continuous voltage device can withstand without damage at rated current.
Imax: Maximum fault current device can withstand without damage at rated voltage.
Pd: Power dissipated from device when in the tripped state in +23 °C still air.
Ri (min.): Minimum resistance of device as supplied at +23 °C unless otherwise specified.
R1(max.): Maximum resistance of device when measured one hour post reflow (SMD) or one hour post trip (radial-leaded device) at +23 °C unless otherwise specified.