FN 2000 SERIES single-phase chassismounting filters Your number one name for EMC SCHAFFNER Schaffner's worldwide sales, distribution and production network HEADQUARTERS Schaffner EMV AG Nordstrasse 11 CH-4542 Luterbach Switzerland Tel: (032) 6816 626 Fax: (032) 6816 641 EUROLOGISTICS CENTER Schaffner 1A, avenue de Suisse F-68311 Illzach France Tel: (03) 89 31 04 00 Fax: (03) 89 31 04 01 FACTORIES Schaffner EMV AG Nordstrasse 11 CH-4542 Luterbach Switzerland Tel: (032) 6816 626 Fax: (032) 6816 641 Schaffner Ltd National Technological Park Castletroy Limerick Ireland Tel: (061) 332233 Fax: (061) 332584 Schaffner EMC Co Ltd 67 Moo 4 Tambol Ban Klang Amphur Muang PO Box 14 Lamphun 51000 Thailand Tel: (053) 581 104 Fax: (053) 581 019 SALES SUBSIDIARIES Schaffner Beijing Liaison Office Room 911, Bright China Chang An Building No. 7 Jianguomennei Dajie Beijing 100005 China Tel: (10) 6510 1761 Fax: (10) 6510 1763 Schaffner SA 43 rue Michel Carre F-95103 Argenteuil France Tel: (01) 34 34 30 60 Fax: (01) 39 47 02 28 Rhone Alpes F-38560 Champ sur Drac Tel: (04) 76 68 64 00 Fax: (04) 76 68 63 70 Rennes F-35510 Cesson-Sevigne Tel: (02) 99 22 70 00 Fax: (02) 99 22 70 07 Schaffner EMV GmbH Schoemperlenstrasse 12B D-76185 Karlsruhe Germany Tel: (0721) 56 910 Fax: (0721) 56 9110 DISTRIBUTORS Northern Germany D-59581 Warstein Tel: (02902) 97 56 10 Fax: (02902) 97 56 80 Czech Republic Energo Praga Ltd. Tel: 2 6111 2665 Schaffner EMC Srl Via Galileo Galilei, 47 I-20092 Cinisello Balsamo (MI) Italy Tel: (02) 66 04 30 45 Fax: (02) 61 23 943 Finland Electro Ferrum Oy Tel: 19 326 616 Schaffner EMC KK 2-31-6 Kamiuma Setagaya-Ku Tokyo 154-0011 Japan Tel: (03) 3418 5822 Fax: (03) 3418 3013 Schaffner EMC Pte Ltd 1200 Depot Road 06-01 Singapore 109675 Singapore Tel: 377 3283 Fax: 377 3281 Schaffner EMC AB Turebergstorg 1,6 S-19186 Sollentuna Sweden Tel: (08) 921121 Fax: (08) 929690 Schaffner Altrac AG Muhlehaldenstrasse 6 CH-8953 Dietikon Switzerland Tel: (01) 744 61 11 Fax: (01) 744 61 61 Schaffner EMC Ltd Ashville Way Molly Millar's Lane Wokingham Berks RG41 2PL UK Tel: (0118) 9770070 Fax: (0118) 9792969 Schaffner EMC Inc 9-B Fadem Road Springfield, NJ 07081 USA Toll free: (800) 367 5566 Tel: (973) 379 7778 Fax: (973) 379 1151 West Coast Irvine, CA 92718 Tel: (949) 457 9400 Fax: (949) 457 9510 Austria Eurodis Electronics GmbH Tel: 1 610 620 Belgium SEI Belgium Tel: 456 0747 Denmark Avnet Nortec A/S Tel: 44 88 08 00 Netherlands SEI Benelux B.V. Tel: 76 57 22 500 Norway Avnet Nortec A/S Tel: 66 77 36 00 Poland Astat Sp. Tel: 61 8488 871 Spain Selco S.A. Tel: 91 637 1011 Sweden Avnet Nortec AB Tel: 8 629 1400 Turkey Artest Elektronik Tel: 216 478 1757 Australia Westek Industrial Products Pty Ltd. Tel: 3 9369 8802 Brasil Teknikao Ind e Com Ltda Tel: 11 834 5544 Hong Kong Denetron (HK) Ltd. Tel: 2 707 9132 India Vishal Agencies Tel: 40 711 2079 Israel RDT Components Ltd. Tel: 3 645 0707 Japan Nemic Lambda K.K. Tel: 3 3447 4411 SSR Engineering Co. Ltd. Tel: 3 3493 6613 Unidux Inc Tel: 422 32 4500 Korea Power EMC TEK Tel: 2 501 5852 New Zealand MHS Technologies Ltd. Tel: 4 567 7016 Republic of South Africa Electronic Building Elements Tel: 12 803 7680 Taiwan Bandtek Int. Co. Ltd. Tel: 2 2747 3733 SCHAFFNER Compact single-phase filters for general-purpose applications Schaffner's FN 2000 series single-phase filters provide an extremely cost-effective solution for a wide range of general-purpose filtering requirements. Employing high performance magnetic and capacitive components, the filters have a very compact form factor, making them particularly suitable for applications where space is at a premium. All FN 2000 Series filters are provided in chassis-mounting metal housings, with a choice of fast-on, wire or screw feed-through connectors for ease of system integration. Designed for operation at up to 250VAC, the filters can handle supply frequencies from DC to 400Hz. This filter range is available in many different standard forms in addition to those shown by the electrical schematics in this shortform catalogue. The multi-stage filters, for example, can be supplied with capacitors connected to the load side, in order to present the best impedance mismatch between equipment and filter. Further information can be obtained from our headquarters in Switzerland, or any subsidiary. Rapid selection Using the current rating and attenuation performance indicators, this table allows you to quickly identify a filter which is potentially suitable for your application, for subsequent detailed investigation on the pages shown. 0 5 10 Current rating (A) 0 Family standard middle 15 20 25 30 Attenuation high CONTENTS very high 100 Mechanical data for FN 20X0 . . . . . . . 12 FN 2010 FN 2010 electrical specification . . . . . . 2 FN 2020 FN 2020 electrical specification . . . . . . 4 FN 2060 FN 2060 electrical specification . . . . . . 6 FN 2070 FN 2070 electrical specification . . . . . . 8 FN 2080 FN 2080 electrical specification . . . . .10 1 SCHAFFNER FN 2010 General-purpose filter The FN 2010 family is designed to provide an economic solution for a wide variety of general-purpose filtering requirements. Available in 15 standard versions, with current ratings from 1 to 30A and a choice of three different connector styles, individual application requirements are easily and economically matched. * * * * * current ratings from 1 to 30A general-purpose filtering performance three choices of connector style optional medical versions (B types) optional safety versions (A types) See Mechanical Data on pages 12 - 13 for full details of housings and connections. Filter selection table Approvals Choose the filter FN xxxx-x with the required current rating and features, and add /?? to determine input/output (line/load) connection style. Example: FN 2010-10/06 is a 10A filter with fast-on connections. Filter Connections V DE EN 133200 Current ratings Inductance A at 40C (25) L mH Capacitance Cx F Cy nF Resistance R M Housing Weight g FN 2010-1 /?? /06 /07 - 1 (1.15) 12 0.1 4.7 1 F3 65 FN 2010-3 /?? /06 /07 - 3 (3.45) 2.5 0.1 4.7 1 F3 65 FN 2010-6 /?? /06 /07 - 6 (6.9) 1 0.1 4.7 1 F3 65 FN 2010-10 /?? /06 /07 - 10 (11.5) 0.8 0.1 4.7 1 F2 85 FN 2010-12 /?? /06 /07 - 12 (13.8) 0.7 0.1 4.7 1 F2 85 FN 2010-16 /?? /06 /07 - 16 (18.4) 0.65 0.1 4.7 1 H2 140 FN 2010-20 /?? /06 - /08 20 (23) 0.6 0.1 4.7 1 K1 210 FN 2010-30 /?? - - /08 30 (34.5) 0.67 0.47 10 1 P 470 Additional specifications and options Filter type Maximum operating voltage VAC Hz Operating frequency Hipot test voltage PN VDC Per Mil-HB-217F at 40C 230V Maximum leakage Hz PNE VAC MTBF hours mA/phase Standard types 250 50/60 DC to 400 2000 1700 800 000 0.4* B medical types (no Y capacitors) 250 50/60 DC to 400 2500 1700 800 000 0.002 A safety types (lower capacitance) 250 50/60 DC to 400 2500 1700 800 000 0.040 * 1mA for 30A version 2 Insertion loss Per CISPR 17; A = 50/50 sym, B = 50/50 asym, C = 0.1/100 sym, D = 100/0.1 sym dB dB 70 70 60 60 50 10 A -10 -20 50 100k 1M 30 20 20 10 10 0 0 -10 -10 10M 100k 1M 10M 16A types dB dB 70 70 A 10k 600 50 500 40 30 20 20 C D 10 300 100 0 00 -10 -10 -100 -20 10k 100k 1M 10M 10k 100k 1M B 200 C D 10 C D 400 B 0 -20 10M 700 A 50 30 1M dBB 60 40 100k 20A types 60 B C D -20 10k 10A types (12A*) B 40 C D -20 10k A 60 B 30 C B 70 A 40 20 0 dB 50 D 40 30 6A types 3A types 1A types 10M -200 A 10k 100k 1M 10M 30A types dB 70 60 50 40 C D 30 B 20 10 A 0 -10 -20 10k 100k 1M 10M * attenuation performance of the 12A version is similar to the 10A component. Electrical schematics FN 2010 R L P' N N' LOAD LINE Cx P E Cy Cy See tables for component values. 3 SCHAFFNER FN 2020 General-purpose filter Similar to FN 2010, but with additional phase-to-neutral capacitance for improved differential mode performance, the FN 2020 family is designed to provide an economic solution for many general-purpose filtering requirements. Available in 15 standard versions, with current ratings from 1 to 30A, individual application requirements are easily and economically matched. * * * * * current ratings from 1 to 30A high differential mode attenuation three choices of connector style optional medical versions (B types) optional safety versions (A types) See Mechanical Data on pages 12 -13 for full details of housings and connections. Filter selection table Approvals Choose the filter FN xxxx-x with the required current rating and features, and add /?? to determine input/output (line/load) connection style. Example: FN 2020-10/06 is a 10A filter with fast-on connections. Filter V DE EN 133200 Current ratings Inductance A at 40C (25) L mH Cx F Cy nF R M Connections Capacitance Resistance Housing Weight g FN 2020-1 /?? /06 /07 - 1 (1.15) 12 0.15 4.7 1 F2 80 FN 2020-3 /?? /06 /07 - 3 (3.45) 2.5 0.15 4.7 1 F2 80 FN 2020-6 /?? /06 /07 - 6 (6.9) 1 0.15 4.7 1 F2 80 FN 2020-10 /?? /06 /07 - 10 (11.5) 0.8 0.15 4.7 1 F2 85 FN 2020-12 /?? /06 /07 - 12 (13.8) 0.7 0.15 4.7 1 F2 85 FN 2020-16 /?? /06 /07 - 16 (18.4) 0.65 0.15 4.7 1 H2 140 FN 2020-20 /?? /06 - /08 20 (23) 0.6 0.15 4.7 1 K1 210 FN 2020-30 /?? - - /08 30 (34.5) 0.67 0.47 10 0.47 P 470 Additional specifications and options Filter type Maximum operating voltage VAC Hz Operating frequency Hipot test voltage PN VDC Per Mil-HB-217F at 40C 230V Maximum leakage Hz PNE VAC MTBF hours mA/phase Standard types 250 50/60 DC to 400 2000 1700 600 000 0.4* B medical types (no Y capacitors) 250 50/60 DC to 400 2500 1700 600 000 0.002 A safety types (lower capacitance) 250 50/60 DC to 400 2500 1700 600 000 0.040 * 1mA for 30A version 4 Insertion loss Per CISPR 17; A = 50/50 sym, B = 50/50 asym, C = 0.1/100 sym, D = 100/0.1 sym 6A types 3A types 1A types dB 70 C dB dB 70 70 60 60 50 50 40 30 20 B 10 A 20 B 30 10 0 0 -10 -10 -10 -20 100k 1M 10M dB 70 70 A D 50 100k 40 B 10k 60 50 50 B 20 20 0 0 -10 -10 -10 -20 -20 10M D C 30 0 1M 10M 40 D 10 100k 1M 70 A 10 10k 100k 20A types 60 30 C 20 10M dB 40 30 1M 16A types dB 60 -20 10k 10A types (12A*) C 20 A 10 10k B 40 C 0 -20 D 50 40 D 30 A 60 D 10 C A B -20 10k 100k 1M 10M 10k 100k 1M 10M 30A types dB 70 D 60 50 40 C 30 20 A 10 B 0 -10 -20 10k 100k 1M 10M * attenuation performance of the 12A version is similar to the 10A component. LINE FN 2020 Cx R L Cx P P' N N' LOAD Electrical schematics E Cy Cy See tables for component values. 5 SCHAFFNER FN 2060 Multi-stage general-purpose filter Similar to FN 2020, but with additional inductance stages for higher common mode attenuation, the FN 2060 family is designed to provide an economic solution for many general-purpose filtering requirements. Available in 16 standard versions, with current ratings from 1 to 30A, individual application requirements are easily and economically matched. * * * * * current ratings from 1 to 30A high differential and common mode attenuation three choices of connector optional medical versions (B types) optional safety versions (A types) See Mechanical Data on pages 12 - 13 for full details of housings and connections. Filter selection table Approvals Choose the filter FN xxxx-x with the required current rating and features, and add /?? to determine input/output (line/load) connection style. Example: FN 2060-10/08 is a 10A filter with screw feed-throngh connections. Filter V DE EN 133200 Current ratings Inductance A at 40C (25) L mH Cx F Cy nF R M 12 0.22 4.7 1 H2 120 Connections Capacitance Resistance Housing Weight g FN 2060-1 /?? /06 /07 - 1 (1.15) FN 2060-3 /?? /06 /07 - 3 (3.45) 2.5 0.22 4.7 1 H2 120 FN 2060-6 /?? /06 /07 - 6 (6.9) 0.97 0.22 4.7 1 H2 120 FN 2060-10 /?? /06 /07 - 10 (11.5) 0.8 0.47 4.7 0.47 K1 190 FN 2060-12 /?? /06 /07 - 12 (13.8) 0.58 0.47 4.7 0.47 K1 190 FN 2060-16 /?? /06 /07 /08 16 (18.4) 0.65 0.33 4.7 1 K2 260 FN 2060-20 /?? /06 - /08 20 (23) 0.6 1 4.7 0.22 P 480 FN 2060-30 /?? - - /08 30 (34.5) 0.6 1 10 0.22 L2 950 Additional specifications and options Filter type Maximum operating voltage VAC Hz Operating frequency Hipot test voltage PN VDC Per Mil-HB-217F at 40C 230V Maximum leakage Hz PNE VAC MTBF hours mA/phase Standard types 250 50/60 DC to 400 2000 1700 450 000 0.4* B medical types (no Y capacitors) 250 50/60 DC to 400 2500 1700 450 000 0.002 A safety types (lower capacitance) 250 50/60 DC to 400 2500 1700 450 000 0.040 * 1mA for 30A version 6 Insertion loss Per CISPR 17; A = 50/50 sym, B = 50/50 asym, C = 0.1/100 sym, D = 100/0.1 sym 6A types 3A types 1A types dBB dB dB 700 70 70 600 60 A 500 50 400 40 300 B 20 100 10 1M 10M 0 C -10 dBB 700 700 600 600 500 500 00 -100 -100 C -200 10k 100k 1M 600 B 1M 10M B 500 400 D C D A 300 200 100 C 00 -100 -200 10k 10M 100k 700 A 100 00 10k dBB 200 D 100 10M 20A types 300 A 200 1M 400 B 300 100k 16A types dBB 400 C -20 10k 10A types (12A*) D 10 -20 100k A 20 D -10 -200 10k B 30 A 0 C -100 50 40 30 D 200 00 60 B 100k 1M 10M -200 10k 100k 1M 10M 30A types dB A 70 60 50 40 C D B 30 20 10 0 -10 -20 10k 100k 1M 10M * attenuation performance of the 12A version is similar to the 10A component. Electrical schematics LINE Cx L R L Cx P P' N N' LOAD FN 2060 E Cy Cy See tables for component values. 7 SCHAFFNER FN 2070 Multi-stage performance filter Similar to FN 2060, but with even higher inductance and capacitance values for excellent differential and common mode attenuation especially at high frequencies - the FN 2070 family is designed to provide a cost-effective solution for broadband filtering requirements. Available in 13 standard versions, with current ratings from 1 to 16A, the filters are ideal for use with precision instrumentation, switched-mode power supplies and motor drives. * * * * * * current ratings from 1 to 16A very high differential and common mode attenuation good high-frequency attenuation three choices of connector optional medical versions (B types) optional safety versions (A types) See Mechanical Data on pages 12 - 13 for full details of housings and connections. Filter selection table Approvals Choose the filter FN xxxx-x with the required current rating and features, and add /?? to determine input/output (line/load) connection style. Example: FN 2070-10/06 is a 10A filter with fast-on connections. Filter V DE EN 133200 Current ratings Inductance A at 40C (25) L mH Cx F Cy nF R M 4.7 1 K1 190 Connections Capacitance Resistance Housing Weight g FN 2070-1 /?? /06 /07 - 1 (1.15) 22 0.33 FN 2070-3 /?? /06 /07 - 3 (3.45) 9.8 0.47 4.7 0.47 K2 250 FN 2070-6 /?? /06 /07 - 6 (6.9) 7.8 1 4.7 0.22 P 450 FN 2070-10 /?? /06 /07 - 10 (11.5) 4.5 1 4.7 0.22 Q 730 FN 2070-12 /?? /06 /07 - 12 (13.8) 3.25 1 4.7 0.22 Q 730 FN 2070-16 /?? /06 /07 /08 16 (18.4) 2.8 1 4.7 0.22 L2 1000 Additional specifications and options Filter type Maximum operating voltage VAC Hz Operating frequency Hipot test voltage PN VDC Per Mil-HB-217F at 40C 230V Maximum leakage Hz PNE VAC MTBF hours mA/phase Standard types 250 50/60 DC to 400 2000 1700 400 000 0.4 B medical types (no Y capacitors) 250 50/60 DC to 400 2500 1700 400 000 0.002 A safety types (lower capacitance) 250 50/60 DC to 400 2500 1700 400 000 0.040 8 Insertion loss Per CISPR 17; A = 50/50 sym, B = 50/50 asym, C = 0.1/100 sym, D = 100/0.1 sym 6A types 3A types 1A types dBB dBB D dBB 700 700 C 700 D 600 600 600 500 500 500 400 400 400 300 300 B C 300 200 200 100 A 00 100 00 -100 -100 -200 -200 10k 100k 1M 10M 100k 1M 10M -200 10k 100k 1M 10M D B 700 D C A 600 500 C 400 400 300 B 200 100 -100 B dB 600 300 100 A 00 B 16A types dBB 500 C B 200 A 10k 10A types (12A*) 700 D 200 A 100 00 0 -100 -100 -200 -200 10k 100k 1M 10M 10k 100k 1M 10M * attenuation performance of the 12A version is similar to the 10A component. Electrical schematics LINE Cx L R L Cx P P' N N' LOAD FN 2070 E Cy Cy See tables for component values. 9 SCHAFFNER Multi-stage high-performance filter FN 2080 Similar to FN 2070, but employing independent differential mode chokes rather than common mode chokes in the second stage, the FN 2080 family of filters provides excellent broadband attenuation, including low frequencies. Available in 13 standard versions, with current ratings from 1 to 16A, the filters are ideal for protecting against very high levels of interference, such as in noisy power supplies. * * * * * * current ratings from 1 to 16A very high differential and common mode attenuation good low-frequency attenuation three choices of connector optional medical versions (B types) optional safety versions (A types) See Mechanical Data on pages 12 -13 for full details of housings and connections. Filter selection table Approvals Choose the filter FN xxxx-x with the required current rating and features, and add /?? to determine input/output (line/load) connection style. Example: FN 2080-10/06 is a 10A filter with fast-on connections. Filter Connections Current ratings Inductance L A at 40C (25) L1 mH V DE EN 133200 Capacitance Resistance Housing Weight Cx F Cy nF R M 4.7 1 K1 200 g FN 2080-1 /?? /06 /07 - 1 (1.15) 22 0.49 0.33 FN 2080-3 /?? /06 /07 - 3 (3.45) 9.8 0.16 0.47 4.7 0.47 K2 270 FN 2080-6 /?? /06 /07 - 6 (6.9) 7.8 0.11 1 4.7 0.22 P 470 FN 2080-10 /?? /06 /07 - 10 (11.5) 4.5 0.06 1 4.7 0.22 Q 750 FN 2080-12 /?? /06 /07 - 12 (13.8) 3.25 0.05 1 4.7 0.22 Q 750 FN 2080-16 /?? /06 /07 /08 16 (18.4) 2.8 0.043 1 4.7 0.22 L2 1020 Additional specifications and options Filter type Maximum operating voltage VAC Hz Operating frequency Hipot test voltage PN VDC Per Mil-HB-217F at 40C 230V Maximum leakage Hz PNE VAC MTBF hours mA/phase Standard types 250 50/60 DC to 400 2000 1700 350 000 0.4 B medical types (no Y capacitors) 250 50/60 DC to 400 2500 1700 350 000 0.002 A safety types (lower capacitance) 250 50/60 DC to 400 2500 1700 350 000 0.040 10 Insertion loss Per CISPR 17; A = 50/50 sym, B = 50/50 asym, C = 0.1/100 sym, D = 100/0.1 sym 6A types 3A types 1A types dBB B 700 A D dB C dB 70 D 70 600 60 60 500 50 50 400 40 C 300 40 B 30 30 200 20 100 10 10 00 0 0 -100 -10 -10 -200 10k -20 100k 1M 10M A 700 20 A 100k B dB D 1M 10M 10k 100k 1M 10M 600 D A 700 C 600 500 500 400 400 300 B 200 A 16A types C 300 B -20 10k 10A types (12A*) dBB D C 200 100 B 100 00 0 -100 -100 -200 -200 10k 100k 1M 10M 10k 100k 1M 10M * attenuation performance of the 12A version is similar to the 10A component. Electrical schematics LINE Cx L R L1 Cx P P' N N' LOAD FN 2080 E Cy Cy See tables for component values. 11 Mechanical Data Housing style F2 SCHAFFNER F3 H2 64 0.3 35 A B C D F J K L M N P S 29.3 K1 71 46.6 29.3 50.5 61 21 10.8/8.3 19.3 24.3 43.5 54 21 8.3/9.3 15.3 5.3 6.3 0.7 85 54 30.3 40.3 64.8 75 27 12.3/8.3 20.8/23.3 5.3 6.3 0.7 19.9/34.9/21.4 20.1/30.5 All dimensions in mm; 1 inch = 25.4mm. K2 with with /07 connections 29.8 11.4/34.9 S C C P L K K J J P TOP M N N M B A F D D F B A Housings F2 and F3 12 0.5 0.5 0.5 0.5 0.3 0.2 0.5 0.5 0.1 0.1 0.1 0.5 * Measurements share this common tolerance unless otherwise stated. /08 connections SIDE L Tol.* mm Housings H2, K1 and K2 I/O connections P Q 113.5 A B C D F J K L M N P Q R S 156 119 0.5 85.5 57.6 98.5 109 40 15.6/8.6 57.5 45.4 1.2 94 103 130.5 143 25 12.4/8.4 32.4 5.3 4.4 Tol.* mm L2 1 1 1 1 0.3 0.2 0.5 0.5 0.1 0.1 0.1 0.3 0.2 0.5 4.4 7.4 1.2 66 51 6 0.9 15.5/38 All dimensions in mm; 1 inch = 25.4mm. with /07 connections These are the standard types of input and output connections available for Schaffner's range of filter families. Schaffner can also produce filters with other popular output connectors, or user-specific interfaces, to custom order. Please call your local sales office to discuss requirements. Dimensions in mm. 1 inch = 25.4mm P/N E 12.3 Housing style 10.8 Mechanical Data * Measurements share this common tolerance unless otherwise stated. SIDE Type /06 Industry-standard size fast-on which may also be used as a solder lug, 6.3 x 0.8mm. S P/N/E C C L J P P 140 +5 -0 K K J Type /07 Insulated wire, stripped ready for soldering. Wire gauge varies according to filter. TOP N M N F A D F P/N E 13.9 A M D Type /08 M4 screw B R Q B Housings P and Q Housing L2 Cross reference list AWG to copper area in mm2 Current ratings 1-3A 6-10A 12-16A AWG number 20 18 16 Cu mm2 (approx) 0.54 0.83 1.34 13 SCHAFFNER 690-407E Schaffner EMV AG CH-4542 Luterbach, Switzerland Tel: [+41] (32) 6816 626 Fax: [+41] (32) 6816 641 www.schaffner.com Benteli Hallwag/January 1999 (c) 1995 Schaffner EMV. Specifications subject to change without notice. All trademarks recognised. Certified ISO 9001 supplier Schaffner is an ISO-registered company. Its products are designed and manufactured under the strict quality requirements of the ISO 9001 standard. This document has been carefully checked. However, Schaffner does not assume any liability for errors or inaccuracies.