6kVDC Isolated 2W Dual Output DC/DC Converters
KDC_NMSC.5 Page 1 of 3
SELECTION GUIDE
Order Code
Nominal Input
Voltage
Output
Voltage Output Current Efficiency Isolation
Capacitance MTTF1
(V) (V) (mA) % pF kHrs
NMS0505C 5 ±5 ±200 74 1.8 747
NMS0509C 5 ±9 ±111 76 1.9 327
NMS0512C 5 ±12 ±83 77 2.0 169
NMS0515C 5 ±15 ±67 78 2.1 93
NMS1205C 12 ±5 ±200 78 1.9 365
NMS1209C 12 ±9 ±111 81 2.0 224
NMS1212C 12 ±12 ±83 82 2.1 136
NMS1215C 12 ±15 ±67 82 2.2 82
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range Continuous operation, 5V input types 4.5 5 5.5 V
Continuous operation, 12V input types 10.8 12 13.2
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated Power2TA=0°C to 70°C 2 W
Voltage Set Point Accuracy See tolerance envelope -7.5 10 %
Line regulation High VIN to low VIN 1.0 1.2 %/%
Load Regulation
10% load to rated load, 5V output types 10 15
%
10% load to rated load, 9V output types 6 15
10% load to rated load, 12V output types 6 15
10% load to rated load, 15V output types 6 15
Ripple and Noise BW=DC to 20MHz, all output types 200 mV p-p
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation test voltage Flash tested for 1 second 6000 VDC
Resistance Viso= 500VDC 10 GΩ
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Switching frequency All input types 35 kHz
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection31 second
Lead temperature 1.5mm from case for 10 seconds 300°C
Internal power dissipation 900mW
Input voltage VIN, NMS05 types 7V
Input voltage VIN, NMS12 types 15V
1. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2. See derating graph.
3. Supply voltage must be disconnected at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
nRoHS compliant
nUL1950 recognized
nEfficiency to 82%
nPower density up to 0.44W/cm3
nDual outputs
nLow profile package
nUL 94V-0 package material
nNo heatsink required
nFootprint 4.75cm2
n6kVDC isolation
n5V & 12V input
n5V, 9V, 12V and 15V output
nInternal SMD construction
nFully encapsulated with toroidal magnetics
nMTTF up to 747 kHrs
nPCB mounting
DESCRIPTION
The NMS series of DC/DC converters are UL1950
recognized which makes them ideal for all
telecom and safety applications where approved
isolation is required. The low profile package
allows mounting in rack systems without risk of
touching other boards. The output configuration
allows all of the rated power to be drawn from a
single pin provided the total load does not exceed
2 watts. The devices feature low noise and low
isolation capacitance suiltable for applications
in high noise environments, e.g. heavy electrical
machine interface.
www.cd4power.com
NMS SERIES
6kVDC Isolated 2W Dual Output DC/DC Converters
KDC_NMSC.5 Page 2 of 3
TEMPERATURE DERATING GRAPH
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specification All output types 0 70
°C
Storage -50 130
Case Temperature above ambient All output types 32
Cooling Free air convection
8060
4020
0
0
1.0
2.0
3.0
Safe Operating Area
70°C
Ambient Temperature (°C)
Output Power (W)
TOLERANCE ENVELOPE
+10%
Output Load Current (%)
Output Voltage
+5%
-7.5%
-2.5%
+2.5%
Typical Load Line
VNOM
100
75
50
25
10
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test
voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
C&D Technologies NMS series of dc/dc converters are all 100% production tested at their stated isolation voltage. This is 6kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NMS series has been recognized by Underwiters Laboratory to a working voltage of 300Vrms for Supplementary Insulation system and 150Vrms for Reinforced
Insulation systems.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on
materials, construction and environment. The NMS series have toroidal isolation transformers, with an additional insulation system between the enameled wire primary
and secondary windings. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the
number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be
reduced by 20% from specified test voltage.
www.cd4power.com
NMS SERIES
6kVDC Isolated 2W Dual Output DC/DC Converters
KDC_NMSC.5 Page 3 of 3
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS PIN CONNECTIONS
Pin Function
1 +VIN
2 -VIN
8 -VOUT
9 NC
10 OV
11 NC
12 +VOUT
13 +VOUT
14 NC
15 OV
16 NC
17 -VOUT
23 NC
24 NC
RECOMMENDED FOOTPRINT DETAILS TUBE OUTLINE DIMENSIONS
."9







 
."9



."9




/.4$
9::88J










/.4$
9::88J
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position. Weight: 7.5g
Unless otherwise stated all dimensions in inches ±0.01 (mm) ±0.5mm.
Tube length : 20.47±0.079 (520mm ±2mm). Tube Quantity : 15













C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing
process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the
current and complete specification for your product before use.
© C&D Technologies (NCL) Limited 2006 KDC_NMSC.5
No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any way including,
but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D
Technologies (NCL) Limited. Instructions for use are available from www.cd4power.com
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS
soldering systems with a peak wave solder
temperature of 300ºC for 10 seconds. The
pin termination finish on this product series
is Matte Tin over Nickel Preplate. The series
is backward compatible with Sn/Pb soldering
systems.
For further information, please visit www.cd4power.com/rohs
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North
Milton Keynes MK14 5BU, UK
Tel: +44 (0)1908 615232
Fax: +44 (0)1908 617545
email: mk@cdtechno.com
Unless otherwise stated all dimensions in inches ±0.01 (mm) ±0.5mm.
C&D Technologies, Inc.
11 Cabot Boulevard, Mansfield,
MA 02048-1151, USA
Tel: +1 (508) 339-3000
Fax: +1 (800) 233-2765
email: sales@cdtechno.com