Range Summary Publication No: US-NP-RS-006 - June 2011 Sealed Rechargeable, Valve Regulated Lead-Acid Batteries GENERAL SPECIFICATIONS GENESIS(R) NPH BATTERY SERIES Type FR Type* NPH3.2-12 NPH3.2-12FR Volts Nominal Capacity (10hr rate-Ah) 12 3.2 Length Width Overall Height incl. Terminals Weight mm (in.) mm (in.) mm (in.) kgs. (lbs) 134 5.28 67 2.64 64 2.52 1.38 3.05 Layout Terminal Illustration 3 A/C Layout Terminal Illustration GENESIS(R) NP BATTERY SERIES Type FR Type* Volts Nominal Capacity (20hr rate-Ah) Length Width Overall Height incl. Terminals Weight mm (in.) mm (in.) mm (in.) kgs. (lbs) NP1-6 NP1-6FR 1.0 51 2.01 42 1.65 57 2.24 0.28 0.61 5 A NP1.2-6 NP1.2-6FR 1.2 97 3.82 25 0.98 56 2.20 0.30 0.67 1 A A/C NP2.8-6 NP2.8-6FR 2.8 67 2.64 33 1.30 105 4.13 0.59 1.30 5 NP3-6 NP3-6FR 3.0 134 5.28 33 1.30 67 2.64 0.69 1.53 1 A NP3.2-6 NP3.2-6FR 3.2 66 2.60 33 1.30 104 4.09 0.59 1.30 5 A NP3.8-6 NP3.8-6FR NP4-6 NP4-6FR 6 3.8 66 2.60 33 1.30 125 4.92 0.75 1.65 1 A 4.0 70 2.76 47 1.85 105 4.15 0.80 1.76 5 A/C NP4.5-6 NP4.5-6FR 4.5 70 2.76 47 1.85 105 4.15 0.86 1.90 5 A/C NP5-6 NP5-6FR 5.0 70 2.76 47 1.85 105 4.15 0.95 2.10 5 A/C NP7-6 NP7-6FR 7.0 151 5.95 33 1.30 100 3.94 1.28 2.83 1 A/C NP8.5-6 NP8.5-6FR 8.5 98 3.86 56 2.20 118 4.65 1.60 3.53 9 A/C NP10-6 NP10-6FR 10.0 151 5.95 50 1.97 101 3.98 1.99 4.38 1 A/C NP12-6 NP12-6FR 12.0 151 5.95 50 1.97 101 3.98 2.04 4.48 1 A/C H/I NP0.8-12 NP0.8-12FR 0.8 96 3.78 25 0.98 61 2.42 0.37 0.82 7 NP1.2-12 NP1.2-12FR 1.2 97 3.82 48 1.89 56 2.20 0.57 1.25 3 A NP2-12 NP2-12FR 2.0 150 5.91 20 0.79 89 3.50 0.70 1.54 8 B NP2-12-C NP2-12CFR 2.0 182 7.17 24 0.93 61 2.40 0.73 1.61 6 L NP2.3-12 NP2.3-12FR 2.3 178 7.01 35 1.38 67 2.64 1.02 2.15 1 A NP2.6-12 NP2.6-12FR 2.6 134 5.28 67 2.64 66 2.60 1.36 3.00 3 A NP2.9-12 NP2.9-12FR 2.9 79 3.11 56 2.20 105 4.13 1.24 2.73 1 A/C NP3-12 NP3-12FR 3.0 132 5.20 33 1.30 105 4.13 1.18 2.60 1 A/C NP3.4-12 NP3.4-12FR 3.4 134 5.28 67 2.64 67 2.64 1.39 3.06 3 A/C NP4-12 NP4-12FR 4.0 90 3.54 70 2.76 107 4.21 1.70 3.74 1 A/C NP4.5-12 NP4.5-12FR 4.5 90 3.54 70 2.76 107 4.21 1.76 3.88 1 A/C NP5-12 NP5-12FR 5.0 90 3.54 70 2.76 107 4.21 1.81 4.00 1 A/C NP7-12 NP7-12FR 7.0 151 5.95 65 2.56 100 3.94 2.59 5.72 4 A/C NP12-12 NP12-12FR 12.0 151 5.95 98 3.86 100 3.94 4.06 8.95 4 C NP18-12 NP18-12FR 17.2 181 7.13 76 3.00 167 6.57 6.17 13.60 2 D/E 12 NP24-12 NP24-12FR 24.0 166 6.54 175 6.89 125 4.92 9.07 20.00 2 C/D/E NP33-12 NP33-12FR 33.0 197 7.76 131 5.16 158+ 6.22+ 11.79 26.00 1 E/F NP35-12 NP35-12FR 35.0 198 7.80 132 5.20 170 6.69 12.61 27.80 1 F NP38-12 NP38-12FR 38.0 197 7.76 165 6.50 172 6.77 14.59 32.16 2 F/G M/E NP55-12 NP55-12FR 55.0 229 9.02 138 5.43 207+ 8.15+ 18.01 39.70 1 NP65-12 NP65-12FR 65.0 350 13.78 166 6.54 174 6.85 23.63 52.10 2 F/G NP75-12 NP75-12FR 75.0 259 10.20 169 6.65 208+ 8.19+ 26.50 58.42 1 M/G M/G NP90-12 NP90-12FR 90.0 304 11.97 168 6.61 229+ 9.02 31.18 68.74 1 NP100-12 NP100-12FR 100.0 329 12.95 174 6.85 214+ 8.43+ 32.94 72.62 1 J/G NP120-12 NP120-12FR 120.0 407 16.02 173 6.81 235 9.25 38.41 84.68 1 J/G NP150-12 NP150-12FR 150.0 483 19.02 170 6.69 241 9.49 47.13 103.90 1 J/G NP200-12 NP200-12FR 200.0 520 20.47 260 10.24 208 8.19 73.00 160.93 3 K/G Layout Terminal Illustration DATASAFE(R) NPX BATTERY SERIES Type FR Type* NPX-35-6 NPX-35-6FR NPX-50 NPX-50FR Volts 6 Watts/Cell to 1.67 End Voltage Nominal Capacity (20hr rate-Ah) Length Width Overall Height incl. Terminals Weight mm (in.) mm (in.) mm (in.) kgs. (lbs) 35W/Cell 8 151 5.95 33 1.30 100 3.94 1.43 3.15 1 A/C 50W/Cell 13 151 5.95 50 1.97 100 3.94 2.09 4.60 1 A/C NPX-25 NPX-25FR 23W/Cell 5 90 3.54 70 2.75 107 4.21 1.95 4.30 1 A/C NPX-35 NPX-35FR 35W/Cell 8 151 5.95 65 2.56 100 3.94 2.75 6.06 4 A/C NPX-80 NPX-80FR NPX-100 NPX-100FR 80W/Cell 20 181 7.13 76 2.39 167 6.57 6.35 14.00 2 D/E 95W/Cell 28 166 6.54 125 4.92 175 6.89 9.70 21.38 2 D/E NPX-135 NPX-150 NPX-135FR 135W/Cell 33 197 7.76 131 5.16 158+ 6.22 11.94 26.32 1 E/F NPX-150FR 150W/Cell 40 197 7.76 165 6.50 172 6.77 14.29 31.50 2 F/G 12 FOOTNOTES: Torque Specifications: * FR: UL94-VO, Flame Retardant Case and Cover (Oxygen index 28) + Height is top cover. Overall Height, including terminal is dependent on the terminal configuration Recognized by UL File No. MH16464 M5 bolt: 26.6 lbf.in (3Nm) +/- 5% M6 bolt: 44.31 lbf.in (5Nm) +/- 5% M5 receptacle: 35.4 lbf.in (4Nm) +/- 5% M6 receptacle: 65 lbf.in (6.8Nm) +/- 5% NOTE: All dimensions are +/- 0.08 inches (2mm); Weights are +/- 5% 2 www.enersys.com Publication No: US-NP-RS-006 - June 2011 Range Summary LAYOUT ILLUSTRATION 1 2 3 4 6 7 8 9 5 TERMINAL ILLUSTRATION A M5 E M5 Threaded Receptacle M F INCH = MM 0.806 20.47 0.760 19.30 0.690 17.53 0.630 16.00 0.394 10.01 0.335 8.50 INCH = MM 0.709 0.551 0.256 0.236 J M8 Bolt Fastened Terminal G M6 Threaded Receptacle K INCH = MM 1.024 26.01 0.910 23.11 0.430 10.92 0.335 8.51 0.315 8.00 INCH = MM 0.472 11.99 0.453 11.51 0.217 5.51 0.079 2.01 M5 Bolt Fastened Terminal M6 18.01 14.00 6.50 5.99 D INCH = MM 0.313 7.95 0.250 6.35 0.180 4.57 0.098 2.49 0.059 1.50 0.031 0.79 0.020 0.51 0.004 0.10 Faston Tab: 250 M6 Bolt Fastened Terminal INCH = MM 0.860 21.84 0.530 13.46 0.430 10.92 0.295 7.49 Tyco. 1-480318-0 M8 C INCH = MM 0.472 11.99 0.250 6.35 0.236 5.99 0.187 4.75 0.130 3.30 0.079 2.01 0.020 0.51 Faston Tab: 187 Faston Tab: 187 I B INCH = MM 0.250 6.35 0.187 4.75 0.124 3.15 0.098 2.49 0.059 1.50 0.031 0.79 0.020 0.51 0.004 0.10 H INCH = MM 0.530 13.46 0.420 10.67 0.310 7.87 0.230 5.84 0.160 4.06 JST No. VHR-2N INCH = MM 1.100 27.94 0.910 23.11 0.510 12.95 0.390 9.91 0.330 8.38 M10 Bolt Fastened Terminal L INCH = MM 0.870 22.01 0.550 13.97 0.430 10.92 0.230 5.84 "Camcorder" Terminal Note: Dimensions are in inches (mm) Tolerances are 0.02 in. for dimensions < 5mm 0.04 in. for dimensions 5mm 0.08 in. for all height dimensions unless otherwise specified. M8 "Universal" Bolt Fastened Terminal Charging Temperature *S tandby use: Apply constant voltage charging at 2.275 volts per cell (or 2.25-2.30VPC). *C yclic use: Apply constant voltage charging at 2.40-2.50 VPC. Initial charging current should be set at less than 0.25CA. *T op charge: Product in storage (ambient temperature 25C/77F) requires a top charge every six months. Apply constant voltage at 2.40 volts per cell, initial charging current should be set at less than 0.1CA for 15 to 20 hours. Discharge *S top operation when voltage has reached the minimum permissible voltage. Recharge immediately. * Do not operate at 6CA or more current continuously. Storage * Always store battery in a fully charged condition. * If battery is to be stored for a long period, apply a recovery top-charge every 6 months. *K eep within ambient temperatures of -15C to +50C for both charging and discharging. Incorporating battery into equipment * Encase battery in a well ventilated compartment. * Avoid installing battery near heated units such as a transformer. *H ouse the battery in the lowest section of the equipment enclosure or rack to prevent unnecessary battery temperature rise. Others * Avoid terminal short circuit. * DO NOT expose to open flame. *W ARNING - Avoid exposure of the battery to any type of oil, solvent, detergent, petroleum-based solvent or ammonia solution. These materials could potentially cause permanent damage to the battery jar and cover and will void the warranty. * Store batteries in a dry and cool location. 3 www.enersys.com Publication No: US-NP-RS-006 - June 2011 CHARGING CHARACTERISTICS RELATIONSHIP BETWEEN CHARGING VOLTAGE AND TEMPERATURE Charging Time (Hours) Ambient Temperature FLOAT SERVICE LIFE NP SERIES CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE NP SERIES TESTING CONDITIONS: FLOATING VOLTAGE: 2.25 TO 2.30V/CELL AMBIENT TEMPERATURE: 20C TO 22C (68F TO 72F) TESTING CONDITIONS: DISCHARGE CURRENT: 0.17C Amp. (F.V. 1.7V/CELL) CHARGING CURRENT: 0.09C Amp. CHARGING VOLUME: 125% OF DISCHARGED CAPACITY AMBIENT TEMPERATURE: 20 C (68F TO 77F) Life (Year) Number of Cycles Publication No: US-NP-RS-006 - June 2011 - Subject to revisions without prior notice E & OE DISCHARGE CHARACTERISTICS Curves at 25C (77F) NP SERIES EnerSys P.O. Box 14145 Reading, PA 19612-4145 USA Tel:+1-610-208-1991 +1-800-538-3627 www.enersys.com EnerSys Europe Zurich, Switzerland Tel: +41 (0) 44 215 74 10 EnerSys Asia Guangdong, China Tel: +86 755 2689 3639 Distributed by: (c) 2011 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates unless otherwise noted.