85 ~ 100W Ultra Slim Step Shape DIN Rail HDR-100 series Bauar t gepruft Sicherheit egel ma ge od o s be wac g (Blank type only) UL508 UL62368-1 www. tuv.com ID 2000000000 EN61558 R33100 RoHS TPTC004 AS/NZS60950-1 IEC62368-1 Features Ultra slim design with 70mm(4SU) width Universal input 85~264VAC(277VAC operational) No load power consumption<0.3W Isolation class Pass LPS (Limited power source) for Blank type DC output voltage adjustable Protections : Short circuit / Overload / Over voltage Cooling by free air convection (working temperature:-30~+70C) DIN rail TS-35/7.5 or 15 mountable Over voltage category LED indicator for power on 3 years warranty Applications Household control system Building automation Industrial control system Factory automation Electro-mechanical apparatus Description HDR-100 is one economical ultra slim 100W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 70mm(4SU) in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 85VAC to 264VAC(277VAC operational) and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current. HDR-100 is designed with plastic housing that it can effectively prevent user from electric hazards. With working efficiency up to 90%, the entire series can operate at the ambient temperature between -30 and 70 under air convection. The complete protection functions and relevant certificates for home automations and industrial control apparatus ( IEC62368 - 1 , UL508, UL62368-1, EN61558-2-16) make HDR-100 a very competitive power supply solution for household and industrial applications. Model Encoding HDR - 100 - 12 N Performance difference Output voltage Rated wattage Series name Type Blank N Description 92W max, Pass LPS with a narrower output adjustable range 100W max, Non-LPS with a wider output adjustable range Note In stock In stock File Name:HDR-100-SPEC 2019-12-04 HDR-100 85 ~ 100W Ultra Slim Step Shape DIN Rail series SPECIFICATION HDR-100-12 HDR-100-12N HDR-100-15 HDR-100-15N HDR-100-24 HDR-100-24N HDR-100-48 HDR-100-48N MODEL OUTPUT DC VOLTAGE 12V RATED CURRENT 7.1A 7.5A 6.13A 6.5A CURRENT RANGE 0 ~ 7.1A 0 ~ 7.5A 0 ~ 6.13A RATED POWER 85.2W 90W 92W RIPPLE & NOISE (max.) Note.2 120mVp-p 12 ~ 13V VOLTAGE ADJ. Pass LPS RANGE 12~ 13.8V Non LPS VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION INPUT 1.0% 3.83A 4.2A 1.92A 2.1A 0 ~ 6.5A 0 ~ 3.83A 0 ~ 4.2A 0 ~1.92A 0 ~ 2.1A 97.5W 92W 100.8W 92.2W 100.8W 120mVp-p 15 ~ 17V 13.5 ~ 18V 1.0% 1.0% 150mVp-p 24 ~ 25.5V 21.6 ~ 29V 1.0% 1.0% 240mVp-p 48 ~ 48.7V 43.2 ~ 55.2V 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% SETUP, RISE TIME 500ms, 60ms/230VAC HOLD UP TIME (Typ.) 30ms/230VAC VOLTAGE RANGE 85 ~ 264VAC (277VAC operational ) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 88% 90% 89% 3A/115VAC 1.6A/230VAC COLD START 35A/115VAC 70A/230VAC HDR-100 : 102 ~ 110% rated output power ; HDR-100-xxN : 105 ~ 150% rated output power AC CURRENT (Typ.) INRUSH CURRENT (Typ.) OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY ENVIRONMENT TEMP. COEFFICIENT VIBRATION 500ms, 60ms/115VAC at full load 12ms/115VAC at full load 120 ~ 370VDC (390VDC operational ) 90% Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed 14.2 ~ 16.2V 18.8 ~ 22.5V Protection type : Shut down o/p voltage, re-power on to recover 56.5 ~ 64.8V 30 ~ 36V -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing 0.03%/ (0 ~ 50) RH non-condensing 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 OPERATING ALTITUDE 2000 meters OVER VOLTAGE CATEGORY ; According to E N 61558, EN50178,EN60664-1, EN62477-1 ; altitude up to 2000 meters SAFETY STANDARDS WITHSTAND VOLTAGE UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN62368-1 I/P-O/P:4KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Standard Parameter Conducted EMC EMISSION SAFETY & EMC (Note 5) Radiated Harmonic Current (Note 5) EMC IMMUNITY MTBF DIMENSION PACKING Test Level / Note EN55032(CISPR32), CNS13438 EN55032(CISPR32), CNS13438 Class B EN61000-3-2 Class A Class B ------- Voltage Flicker EN61000-3-3 EN55024, EN61000-6-2, EN61204-3 Parameter Standard Test Level /Note ESD Level 3, 8KV air; Level 2, 4KV contact, criteria A Radiated Susceptibility OTHERS 48V 24V 15V EFT/Burest Surge EN61000-4-2 EN61000-4-3 EN61000-4-4 Conducted Magnetic Field EN61000-4-5 EN61000-4-6 EN61000-4-8 Voltage Dips and interruptions EN61000-4-11 Level 3, criteria A Level 3, criteria A Level 4,2KV/L-N, criteria A Level 3, criteria A Level 4, criteria A 95% dip 0. 5 periods, 30% dip 25 periods, 95% interruptions 250 periods 856.5K hrs min. MIL-HDBK-217F (25) 70*90*54.5mm (W*H*D) 0.27Kg; 48pcs/14Kg/1.06CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1f & 47f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. NOTE 4. Harmonic current test at 90% load for HDR-100-xxN. 5. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:HDR-100-SPEC 2019-12-04 HDR-100 85 ~ 100W Ultra Slim Step Shape DIN Rail series Block Diagram RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING -V DETECTION CIRCUIT PWM CONTROL O.L.P. +V O.V.P. Output Derating VS Input Voltage Derating Curve VS Ambient Temperature 100 100 230VAC Input 90 80 80 110VAC Input 70 50 LOAD (%) LOAD (%) 60 40 20 -30 0 10 20 30 40 45 50 60 70 (VERTICAL) 60 50 40 85 95 100 110 115 120 140 160 180 200 220 240 277 (operational) AMBIENT TEMPERATURE (? ) INPUT VOLTAGE (VAC) 60Hz File Name:HDR-100-SPEC 2019-12-04 HDR-100 85 ~ 100W Ultra Slim Step Shape DIN Rail series Mechanical Specification (Unit: mm , tolerance 0.5mm) 58.4 70 70 54.5 1 2 45.15 90 1 63.65 3 4 5 6 3 4 5 6 2 35 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Terminal Pin No. Assignment Pin No. 1 2 Assignment Pin No. AC/L 3,4 AC/N 5,6 Assignment -V +V Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:HDR-100-SPEC 2019-12-04