1209 FIBER SENSORS Pulse Air-gun Ionizer EC-G02 Related Information High-frequency AC Method General terms and conditions.............. F-3 Glossary of terms.......................... P.1591 Selection guide............................ P.1155~ General precautions...................... P.1595 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS panasonic.net/id/pidsx/global Air-gun type ionizer that can remove dust in a single burst using pulsed ion air Three discharge modes White LED illumination Pulse air mode FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Static Removers Pulse Air-gun The EC-G02 features two pulse air modes in addition to the standard continuous mode. Cleaning Box Electrostatic Sensor EC-G02 The EC-G02 features a highbrightness white LED above the ionized air outlet, allowing you to target and spray dust revealed by the light with a stream of ionized air. Improved dust removal effectiveness thanks to pulse (intermittent) air Since pulse air causes dust to oscillate and lifts it up, even difficult-to-dislodge dust inside concave pockets can be easily removed. The EC-G02 can deliver greater dust removal effectiveness than continuous airflow models. Pulse air Compact, highly usable design A high-voltage power supply circuit and solenoid valve are built into the air gun, providing a high level of usability and eliminating the need to install an external controller or route thick, highvoltage cables. Additionally, since the lightweight unit weighs just 270 g, it reduces stress on the operator, even when used for extended periods of time. External input External input allows the unit to be used in combination with a foot switch or other device. No-oil compliance All parts along the air path (air nozzle, solenoid valve, joints, etc.) are no-oil compliant. Pulse Air-gun Ionizer ORDER GUIDE Type Gun type EC-G02 1210 OPTIONS Charge removal time (1,000 V 100 V) Model No. 0.5 sec. approx. or less (Note) EC-G02 Note: Typical value for pulse air mode: CONT at 100 mm 3.937 in from the front of discharge nozzle at an applied air pressure of 0.50 MPa. FIBER SENSORS Designation Model No. Description LASER SENSORS Discharge needle EC-GANT For replacement (1 pc.) Solenoid valve EC-GAV For replacement (1 pc.) PHOTOELECTRIC SENSORS SPECIFICATIONS Item AREA SENSORS Type Gun type Model No. EC-G02 CE marking directive compliance SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS EMC Directive, RoHS Directive Charge removal time Air (dried clean air) (Note 3) 300 /min. (ANR) or less Supplied air flow Power consumption 0.05 to 0.50 MPa Accessory AC adapter INPUT: 100-240 V AC 10 % 50/60 Hz (OUTPUT: 24 V DC) 30 VA or less Discharge method High-frequency AC method Supply voltage Pulse air mode LED illumination mode External input Ambient temperature INDUCTIVE PROXIMITY SENSORS 0.5 sec. approx. or less (1,000 V 100 V) (Note 2) Applicable fluid Air pressure range MICRO PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Pulse 1 (long) / Pulse 2 (short) / CONT (continuous) selectable by switch WIRE-SAVING SYSTEMS ON (always ON) / SYNC (synchronized with trigger) / OFF (always OFF) Ionized air emission operation ON/OFF using OR control with trigger switch Ionized air emission operation ON: Short-circuited to COM (-) Ionized air emission operation OFF: Open 0 to +50 C +32 to +122 F (No dew condensation allowed), AC adapter: 0 to +40 C +32 to +104 F Ambient humidity MEASUREMENT SENSORS STATIC CONTROL DEVICES 35 to 65 % RH (No dew condensation allowed) 270 g approx. (main unit only) Weight AC adapter: 1pc. Exclusive intermediate cable (oil-resistant, heat-resistant, bending-resistant type) length 2 m 6.562 ft: 1 pc. Straight joints Accessories * Tube outer diameter o8-o8 mm o0.315-o0.315 in compatible type: 1 pc. (Note 4) * Tube outer diameter o8-o6 mm o0.315-o0.236 in compatible type: 1 pc. * Connector connection terminal (Manufactured by Molex): 3 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Typical value for pulse air mode: CONT at 100 mm 3.937 in from the front of discharge nozzle at an applied air pressure of 0.50 MPa. 3) Dried clean air is the air passing through air dryer (dew point -20 C -4 F approx.) and air filter (mesh size 0.01 m 0.0004 mil approx.) 4) At the time of shipment from the factory, o8-o8 mm o0.315-o0.315 in type is attached. PRECAUTIONS FOR PROPER USE * This product includes precision components, so do not drop it or hit it against other objects. If this is not observed, accidents or problems with operation may occur. * Never use this product in a device for personnel protection. * Do not use this product in places where there may be danger of flammable or combustible items being present. * High voltages are applied to the discharge needle, so never touch the discharge needle while the power for the product is turned on, otherwise electric shocks may result. * Since the tip of the discharge needle is sharp, take sufficient care in handling the discharge needle, or injuries may result. * If this product is used in an airtight room, ozone emitted from this product may be detrimental. Therefore, in order for this product to be used in an airtight room, be sure to keep the room ventilated. * Do not direct ionized air toward the face. Ozone may cause irritation to places such as the nose and throat. * Do not look directly into the white LED spotlight. It may cause injury to the eyes. The CAD data can be downloaded from our website. EC-G02 PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS DIMENSIONS (Unit: mm in) Refer to p.1595 for general precautions. LASER MARKERS UV CURING SYSTEMS Ionizer main unit Selection Guide ( ) 14 0.551 144 5.670 (12.5 0.492) White LED ( ) 10 0.394 Static Removers 51 2.026 (4 0.157) Pulse Air-gun Cleaning Box Electrostatic Sensor Nozzle Mode select switches Trigger Cable connector (Note) Straight joint 173 6.811 ( ) 185 7.283 (31 1.220) Solenoid valve EC-G02 indicator 8 (0.315 ) (31 1.220) Note: An exclusive intermediate cable (oil-resistant, heat-resistant, bendingresistant type, o3.7 mm o0.146 in, 2 m 6.562 ft long) is attached.