https://www.phoenixcontact.com/us/products/2688048 I/O module - AXL F DO16/3 2F - 2688048 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline F digital output module, 16 outputs, 24 V DC, 500 mA, 2 or 3-wire connection method (including bus base module and connectors) Product description The module is designed for use within an AxiolineF station. It is used to output digital signals. The outputs are protected against short circuit and overload. Product Features 16 digital outputs 24 V DC, 500 mA Connection of actuators in 2 and 3-wire technology Minimum update time of < 100 s Device rating plate stored Diagnostic and status indicators Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 280.0 GRM Custom tariff number 85389091 Country of origin Germany Technical data Dimensions Width 53.6 mm Height 129.9 mm Depth 54 mm Note on dimensions The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715). 09/03/2014 Page 1 / 6 https://www.phoenixcontact.com/us/products/2688048 I/O module - AXL F DO16/3 2F - 2688048 Technical data Ambient conditions Ambient temperature (operation) -25 C ... 60 C Ambient temperature (storage/transport) -40 C ... 85 C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Connection data Designation Axioline F connector Connection method Push-in technology Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 1.5 mm Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 1.5 mm Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 16 Stripping length 8 mm General Weight 234 g Note on weight specifications with connectors and bus base module Mounting type DIN rail Protection class III, IEC 61140, EN 61140, VDE 0140-1 Test section 5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min 5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min 24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min Conformance with EMC directives Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 6100042/IEC 6100042 Criterion B; 6 kV contact discharge, 8 kV air discharge Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 6100043/IEC 6100043 Criterion A; Field intensity: 10 V/m Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 6100044/IEC 6100044 Criterion B, 2 kV Noise immunity test in accordance with EN 61000-6-2 Transient surge voltage (surge) EN 6100045/IEC 6100045 Criterion B; DC supply lines: 0.5 kV/0.5 kV (symmetrical/asymmetrical) Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 6100046/IEC 6100046 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B 09/03/2014 Page 2 / 6 https://www.phoenixcontact.com/us/products/2688048 I/O module - AXL F DO16/3 2F - 2688048 Technical data General Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Diagnostics messages I/O supply failure configurable Short-circuit / overload of the digital outputs Yes Interfaces Designation Axioline F local bus Connection method Bus base module Transmission speed 100 MBit/s Axioline potentials Communications power UBus 5 V DC (via bus base module) Current consumption from UBus max. 120 mA Supply of digital output modules UO 24 V DC Current consumption from UO max. 8 A (external fuse) Digital outputs Output name Digital outputs Connection method Push-in technology 2, 3-wire Number of outputs 16 Protective circuit Short-circuit protection, overload protection of the outputs Electronic Output voltage 24 V Nominal output voltage 24 V DC Maximum output current per channel 500 mA Maximum output current per module 8 A (external fuse) Nominal load, inductive max. 12 VA (1.2 H; 48 ; with nominal voltage) Nominal load, lamp max. 12 W (at nominal voltage) Nominal load, ohmic max. 12 W (48 ; with nominal voltage) Classifications eCl@ss eCl@ss 4.0 27240404 eCl@ss 4.1 27240404 eCl@ss 5.0 27242204 eCl@ss 5.1 27242604 eCl@ss 6.0 27242604 09/03/2014 Page 3 / 6 https://www.phoenixcontact.com/us/products/2688048 I/O module - AXL F DO16/3 2F - 2688048 Classifications eCl@ss eCl@ss 7.0 27242604 eCl@ss 8.0 27242604 ETIM ETIM 3.0 EC001599 ETIM 4.0 EC001599 ETIM 5.0 EC001599 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 39121311 UNSPSC 12.01 39121311 UNSPSC 13.2 39121311 Approvals Approvals Approvals UL Listed / cUL Listed / BSH / RINA / GL / DNV / BV / LR / GL-SW / ABS / cULus Listed / GL Ex Approvals Approvals submitted Approval details UL Listed cUL Listed 09/03/2014 Page 4 / 6 https://www.phoenixcontact.com/us/products/2688048 I/O module - AXL F DO16/3 2F - 2688048 Approvals BSH RINA GL DNV BV LR GL-SW ABS cULus Listed GL Drawings Dimensioned drawing 00 01 10 11 20 21 30 31 OUT 2 OUT 1 129,9 54 122,4 53,6 Connection diagram 09/03/2014 Page 5 / 6 https://www.phoenixcontact.com/us/products/2688048 I/O module - AXL F DO16/3 2F - 2688048 Diagram DO 9...16 OUT40 Output circuit 8x OUT46 OUT47 Energy consumption [J] Block diagram 0,4 Only with external free running circuit 0,35 0,3 0,25 0,2 0,15 0,1 0,05 1 = 0,5 A 2 = 0,4 A 3 = 0,3 A 4 = 0,2 A 5 = 0,1 A 1 2 3 4 5 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,4 40 46 47 56 57 Inductance [H] UBus 4x mC Axio bus D UO E1 00 06 07 16 17 OUT07 OUT06 Output circuit 8x OUT00 Maximum energy consumption of the outputs when switching off inductive loads The diagram shows the maximum amount of energy that may be fed back into the corresponding output groups (outputs 1 to 4, 5 to 8, 9 to 12, 13 to 16) for each switch off procedure when switching off an inductive load without external freewheeling circuit. The current data refers to the ohmic DC voltage component of the inductive load. Note: Restrict freewheeling voltage to a maximum of -15 V when using an external freewheeling circuit. The external freewheeling circuit has no function in the event of a higher negative voltage. DO 1...8 UO 24V Internal wiring of the terminal points Phoenix Contact 2014 (c) - all rights reserved http://www.phoenixcontact.com 09/03/2014 Page 6 / 6