4
2401 Stanwell Drive, Concord Ca. 94520 Ph: 925-687-4411 Fax: 925-687-3333 www.calex.com Email: sales@calex.com
ECO 141118-1, 150722-1, 170530-3, 171030-1
75 WATT WDE SERIES
DIGITAL DC/DC CONVERTERS
General Specications
All Models Units
ON/OFF Function
Converter - ON
HIGH Logic Level / Leave
ON/OFF Pin Open (11)
MIN 3.0 V
External Leakage Current
Allowed for Logic High (7) MAX 10 µA
Converter - OFF
LOW Logic Level / Tie
ON/OFF Pin to -INPUT (11)
MAX 1.0 V
Sinking Current for Logic
Low MAX 500 µA
Idle Current
(Module is OFF) TYP 40 mA
Turn-on Time to 1% error TYP 40 ms
Output Voltage Remote Sensing (12)
Maximum Voltage Drops
on Leads MAX 750 mV
Line Regulation under
remote sensing
TYP
MAX
0.2
1%
Load Regulation under
remote sensing
TYP
MAX
0.2
1%
Output Voltage Trim (12)
Trim Range MIN
TYP
-20
+10 % of Vout
Input Resistance TYP 47.5 kΩ
Open Circuit Voltage TYP 2.0 V
Trim Limit
Maximum Output Voltage TYP 110 % of Vout
Isolation
Input to Output Isolation
10µA Leakage MAX 1544 VDC
Input to Output Resistance MIN 10 MΩ
Input to Output
Capacitance TYP 3300 pF
Environmental
MTBF
Telcordia (Bellcore)
standard SR-332, issue
2, using Method 1.
50% electrical stress, 40ºC
Components
10.9 Million hours
Case Operating
Temperature Range
MIN
MAX
-55
+100 ºC
Storage Temperature MIN
MAX
-55
+120 ºC
Thermal Impedance (8) TYP 9 ºC/W
Thermal Shutdown Internal
Temperature (Auto Restart) TYP 110 ºC
General
Unit Weight 55 g
Case Dimension 2.5” x 1.1” x 0.50”
Designed to meet UL/cUL 60950, IEC/EN 60950-1
Notes:
(1) All parameters measured at Tc=+25ºC ambient, Vin = Vnom,
maximum rated load, unless otherwise noted. Refer to CALEX
Application Notes for denition of terms, measurement circuits
and other information.
(2) External fusing should be used for system protection in the event
of a catastrophic failure. See CALEX Application Note 9 in the
Calex DC/DC Catalog to determine the correct fuse.
(3) Output noise is measured with a 10µF ceramic capacitor and a
1µF ceramic capacitor connected across the output pins. The
fundamental component of noise is at the switching frequency.
Using smaller value capacitors will make the output noise slightly
higher. Bandwidth limit is 20 MHz. In system board design high-
voltage capacitors between input and output from 1000pF to
6800pF can be used to reduce common-mode noise.
(4) Load Transient Overshoot is the output voltage peak amplitude,
referenced to the nal value, due to a step load change from
50% of maximum load to 75% of maximum load. “Load Transient
Overshoot” and “Dynamic Response” are the same specication.
Load Transient Recovery Time is the time it takes the output
to return to the specied voltage error band centered around
the nal value. Transient response may degrade at low load
currents.
(5) Temperature coefcient is dened for case temperatures. Output
voltage deviation is calculated as the maximum resulting from
either 1) 25ºC case to maximum operating case temperature, or
2) 25ºC case to minimum operating case temperature.
(6) Load regulation is dened as the output voltage change resulting
from a load current change from minimum to maximum. The
voltage is measured at the output pins.
(7) When an external ON/OFF switch is used, such as an open
collector switch, logic high requires the switch to be high-
impedance. Switch leakage currents greater than 10µA may be
sufcient to trigger the ON/OFF to the logic-low state.
(8) Thermal impedance is tested with the converter mounted
vertically and facing another printed circuit board 1/2 inch away.
Thermal impedance is approximately 9ºC/W.
(9) Water washability - Calex DC/DC converters are designed
to withstand most solder/wash processes. Careful attention
should be used when assessing the applicability in your specic
manufacturing process. Converters are not hermetically sealed.
(10) The input impedance on these units must be kept to a maximum of
100mΩ. In order to support this requirement, this converter needs
55µF of capacitance (low ESR) for every 1.0µH of inductance
between the power source and the DC/DC converter.
(11) The range between 1V as maximum turn off voltage and 3V as
minimum turn on voltage is considered the dead-band. Operation
in the dead-band is not recommended.
(12) Refer to Calex Application Note 4 for methods to apply Remote
Sense and Trim.
(13) Specications subject to change without notice.
(14) RoHS Compliance:
See Calex Website www.calex.com/RoHS.html for the complete
RoHS Compliance statement.
The RoHS marking is as follows.