DENSEI-LAMBDA
A153-01-01D MODEL ZWS10-3 ZWS10-5 ZWS10-12 ZWS10-15 ZWS10-24
ITEMS
1 Nominal Output Voltage V3.3 5 12 15 24
2 Minimum Output Current A00000
3 Maximum Output Current A2.0 2.0 0.85 0.7 0.45
4 Maximum Peak Output Current (*1) A2.4 2.4 1.02 0.84 0.54
5 Maximum Output Power W6.6 10.0 10.2 10.5 10.8
6 Maximum Peak Output Power (*1) W7.92 12.0 12.24 12.6 12.96
7 Efficiency (Typ) (*2) %62 70 70 71 71
8 Input Voltage Range (*3) -85 - 265VAC (47 - 440Hz) or 110 - 330VDC
9 Input Current(Typ) -0.30A at 100VAC, 0.15A at 200VAC
10 Inrush Current(Typ) -15A at 100VAC, 30A at 200VAC, Ta=25°C, Cold Start
11 Output Voltage Range -
-10%
12 Maximum Ripple & Noise 0 - +60°C mV 120 120 150 150 200
(*10) -10 - 0°C mV 160 160 180 180 200
13 Maximum Line Regulation (*4,10) mV 20 20 48 60 96
14 Maximum Load Regulation (*5,10) mV 40 40 96 120 150
15 Maximum Temperature Drift (*6) mV 60 60 140 180 280
16 Over Current Protection (*7) -125% -
17 Over Voltage Protection (*8) -140% -
18 Hold-up Time (Typ) (*2) -17ms at 100VAC, 10W, Ta=25°C
19 Parallel Operation - -
20 Series Operation (*9) - Possible
21 Operating Temperature (*11) --10°C - +50°C : 100%, +60°C : 70%
22 Operating Humidity - 30 - 90%RH
23 Storage Temperature --30°C - +85°C
24 Storage Humidity - 10 - 95%RH
25 Cooling -Convection Cooling
26 Withstand Voltage - Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
at 25°C and 70%RH Output - FG 500VDC
28 Vibration -10-55Hz (Sweep 1min) Less than 19.6m/s
X,Y,Z 1h each
29 Shock -Less than 196.1m/s
30 Safety -Approved by UL60950-1,CSA60950-1,EN60950-1. Built to meet DENAN
31 Conducted Noise -Built to meet EN55022-B, FCC-ClassB, VCCI-B
32 Weight (Typ) g 120
33 Size (WxHxD) mm 50 x 21 x 105
=NOTES=
*1. Operating time at peak output is less than
10 seconds. (Duty=0.35)
At 100VAC and maximum output current , Ta=25°C.
For cases where conformance to various safety
specs (UL,CSA) are required, to be described
as 100 - 240VAC, 50/60Hz on name plate.
From 85 - 265VAC and constant load.
From Min load - Full load (Maximum Power)
and constant input voltage.
From -10 - +50°C constant input voltage and load.
Current limiting with automatic recovery.
Avoid to operate over load or dead short for 30 seconds.
Over voltage clamping by Zener Diode.
Refer to Instruction Manual.
Please refer to Fig A for measurement of line
& load regulation and ripple voltage.
At standard mounting method, Fig B.