SIDACtor Device SIDACtor Device DO-214AA SIDACtor solid state protection devices protect telecommunications equipment such as modems, line cards, fax machines, and other CPE. SIDACtor devices are used to enable equipment to meet various regulatory requirements including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A (formerly known as FCC Part 68). Electrical Parameters Part Number * VDRM Volts VS Volts VT Volts IDRM Amps IS mAmps P0080S_ 6 25 4 5 800 P0220S_ 15 32 4 5 800 P0300S_ 25 40 4 5 800 P0640S_ 58 77 4 5 P0720S_ 65 88 4 5 P0900S_ 75 98 4 P1100S_ 90 130 P1300S_ 120 P1500S_ 140 P1800S_ IT Amps IH mAmps CO pF 2.2 50 100 2.2 50 50 2.2 50 110 800 2.2 150 50 800 2.2 150 50 5 800 2.2 150 50 4 5 800 2.2 150 40 160 4 5 800 2.2 150 40 180 4 5 800 2.2 150 40 170 220 4 5 800 2.2 150 30 P2300S_ 190 260 4 5 800 2.2 150 30 P2600S_ 220 300 4 5 800 2.2 150 30 P3100S_ 275 350 4 5 800 2.2 150 30 P3500S_ 320 400 4 5 800 2.2 150 30 * For individual "SA", "SB", and "SC" surge ratings, see table below. General Notes: * All measurements are made at an ambient temperature of 25 C. IPP applies to -40 C through +85 C temperature range. * IPP is a repetitive surge rating and is guaranteed for the life of the product. * Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities. * VDRM is measured at IDRM. * VS is measured at 100 V/s. * Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request. * Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias and is a typical value for "SA" and "SB" product. "SC" capacitance is approximately 2x the listed value. The off-state capacitance of the P0080SB is equal to the "SC" device. Surge Ratings Series IPP 2x10 s Amps IPP 8x20 s Amps A 150 150 90 50 45 20 500 B 250 250 150 100 80 30 500 C 500 400 200 150 100 50 500 http://www.littelfuse.com +1 972-580-7777 IPP 10x160 s Amps IPP 10x560 s Amps 2-4 IPP 10x1000 s Amps ITSM 60 Hz Amps di/dt Amps/s (c) 2004 Littelfuse, Inc. SIDACtor(R) Data Book and Design Guide SIDACtor Device Thermal Considerations Symbol TJ Operating Junction Temperature Range -40 to +150 C TS Storage Temperature Range -65 to +150 C 90 C/W RJA Parameter Value Thermal Resistance: Junction to Ambient Unit IPP - Peak Pulse Current - %IPP +I +I IITT ISS IH IDRM -V -V +V +V V VTT V VDRM DRM V VS S Peak Value 100 tr = rise time to peak value td = decay time to half value Waveform = tr x td 50 Half Value 0 0 tr td t - Time (s) -I -I V-I Characteristics tr x td Pulse Wave-form IH 8 6 25 C 4 2 IH (TC = 25 C) 10 Ratio of Percent of VS Change - % 14 12 0 -4 2.0 1.8 1.6 1.4 25 C 1.2 1.0 0.8 0.6 0.4 -40 -20 0 -6 -8 -40 -20 0 20 40 60 80 100 120 140 160 Case Temperature (TC) - C 20 40 60 80 100 120 140 160 Junction Temperature (TJ) - C Normalized VS Change versus Junction Temperature (c) 2004 Littelfuse, Inc. SIDACtor(R) Data Book and Design Guide Normalized DC Holding Current versus Case Temperature 2-5 http://www.littelfuse.com +1 972-580-7777 Data Sheets Package DO-214AA