1© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6005_S01 • 3/7/2014
One world. One KEMET
Benets
16 – 80 V working voltage
Individually balanced cells
IP–54 rated
Threaded, protected terminals
• Operatingtemperaturerangeof-40˚Cto+65˚C
Optional voltage and over temperature signal
Cycle life > 500,000 cycles
RoHS Compliant
Made in USA
Overview
KEMET S01 Series Supercapacitors are bank modules in which
the cells are encased in a plastic holder.
Applications
Typical applications include wind turbine pitch control, starting
systems, automotive subsystems, backup power/UPS, ride
through/power conditioning, and renewable energy systems.
Bank Module Supercapacitors
S01 Series, Molded Plastic Cell Module
Part Number System
S01 P M 5805 K16 AUxxx
Series Conguration
Code Balancing
CongurationCode
Capacitor Type
Capacitance Code
(µF)
Capacitance
Tolerance
Rated Voltage
(VDC)
Termination
Code
C-Spec
Supercapacitor,
Bank Module,
Molded Plastic
Holder
P = Passive
without
clamping
M = Snap-in,
multi-pin style
First three digits
representsignicant
gures.Fourthdigit
speciesnumberof
zeros.
K = ±10%
R = -0%
016 = 16 V
080 = 80 V
A=Therst
mechanical
conguration
of a
particular
part number
Blank = No monitor
U808 = Digital Overvoltage
and analog over temperature
monitor
U809 = Digital Overvoltage
and digital over temperature
monitor
U810 = Overvoltage and
Overtemperature monitor
through CAN Bus
2© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6005_S01 • 3/7/2014
Bank Module Supercapacitors – S01 Series, Molded Plastic Cell Module
Dimensions – Millimeters
S01PM5805K016A
S01PM1205R080A
S01PM1205R080AU809
Part Number
L
W
H
Nominal Tolerance Nominal Tolerance Nominal Tolerance
S01PM5805K016A 225.37 +/-1.0 50.8 +/-1.0 75.19 +/-1.0
S01PM1205R080A 238 +/-1.0 247 +/-1.0 74 +/-1.0
S01PM1205R080AU809 238 +/-1.0 247 +/-1.0 74 +/-1.0
3© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6005_S01 • 3/7/2014
Bank Module Supercapacitors – S01 Series, Molded Plastic Cell Module
Performance Characteristics
Item Performance Characteristics
Rated Voltage 16 – 81 VDC
Surge Voltage 17 – 85 VDC
Isolation Voltage/High Potential 2,500 V
Capacitance Range 12 – 58 F
Capacitance Tolerance ±10%, -0%
Temperature Range -40°Cto+65°C
Storage Temperature Range -40°Cto+70°C
Temperature Characteristics
CapacitanceChange:Within±5%ofinitialspeciedvalue
InternalResistance(ESR):Within100%ofinitialspeciedvalue
Life, DC
10 years, rated voltage, 25°C
ΔC<30%decrease,ESR<100%increase
Life, Endurance
1,000 hours, rated voltage, 65°C
ΔC<30%decrease,ESR<100%increase
Life, Shelf
1,000 hours, no voltage, 70°C
ΔC<20%decrease,ESR<100%increase
Life, Cycle
> 500,000 cycles, rated to half rated voltage, 25°C
ΔC<30%decrease,ESR<100%increase
Maximum Number in Series 40 (750 V)
Standards Compliance RoHS, UL810a
Approvals
Series / Partnumber Test Type Test Standard
S01PM5805K016A
Vibration IEC 60068-2-6
January 2011
Mechanical shock IEC 60068-2-27
Underwriters Laboratory UL810A March 2011
SAE Safety And Abuse SAE J2464 pending Q1 2014
S01PM1205R080A
S01PM1205R080AU809
S02AT5006R016AU808
S02AT1656R048AU808
pending pending Q1 2014
4© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6005_S01 • 3/7/2014
Bank Module Supercapacitors – S01 Series, Molded Plastic Cell Module
Environmental Compliance
All KEMET supercapacitors are RoHS Compliant.
Table 1 – Ratings & Part Number Reference
Part Number S01PM5805K016A S01PM1205R080A1S01PM1205R080AU8091
Parameter
Capacitance (F) 58 11.6 11.6
Capacitance Tolerance ±10% -0% -0%
Rated Voltage (V) 16 81 81
Surge Voltage (V) 17 85 85
Impedance[AC1kHz](mΩ) ≤15 ≤80 ≤80
ESR[DC](mΩ) ≤23 ≤90 ≤90
Leakage Current [72 h] (mA) <25 125 125
Continuous Current Rating (A) 19 10 10
Maximum Peak Current 1 s (A) 200 200 200
Short Circuit Peak Current (A) 1,000 700 700
Cell Management Passive Passive Passive
Overvoltage & Over Temperature
Monitor
No No Yes
Energy/Power
Maximum Stored Energy (Wh) 2.1 10.6 10.6
Energy Density (Wh/kg) 2.8 2.7 2.7
Energy Density (Wh/L) 3.6 3.5 3.5
Power Density (kW/kg) 5.8 6.3 6.3
Power Density (kW/L) 7.4 2.3 2.3
Maximum Power (kW/kg) 1.8 3 3
Physical
CongurationCode
PM
PM
PM
L x W x H (mm) 225 x 51 x 76 238 x 247 x 74 238 x 247 x 74
Weight (kg) 0.76 3 3
Volume (ml) 594 3900 3900
1Preliminary (See Prototype Sample Disclaimer)
5© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6005_S01 • 3/7/2014
Bank Module Supercapacitors – S01 Series, Molded Plastic Cell Module
Mounting
Specicusersguidewithmountinginstructionsshipwithmodule.
Packaging Quantities
Part Number Capacitance
(F)
Rated
Voltage
Package
Type
Package
Quantity
Box
Weight
Box
Length
Box
Width
Box
Height
S01PM5805K016A 58 16 Box 1 2 lbs (0.9 kgs) 10.0" (254 mm) 6.0" (153 mm) 3.5" (89 mm)
S01PM1205R080A 12 80 Carton 1 7 lbs (3.2 kgs) 11.0" (279 mm) 8.5" (216 mm) 3.5" (89 mm)
S01PM1205R080AU809 12 80 Carton 1 7 lbs (3.2 kgs) 11.0" (279 mm) 8.5" (216 mm) 3.5" (89 mm)
Standard Marking
KEMET logo
Rated voltage
Rated capacitance
Terminal markings
6© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6005_S01 • 3/7/2014
Bank Module Supercapacitors – S01 Series, Molded Plastic Cell Module
KEMET Corporation
World Headquarters
2835 KEMET Way
Simpsonville, SC 29681
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Corporate Of ces
Fort Lauderdale, FL
Tel: 954-766-2800
North America
Southeast
Lake Mary, FL
Tel: 407-855-8886
Northeast
Wilmington, MA
Tel: 978-658-1663
Central
Novi, MI
Tel: 248-306-9353
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Europe
Southern Europe
Paris, France
Tel: 33-1-4646-1006
Sasso Marconi, Italy
Tel: 39-051-939111
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Kamen, Germany
Tel: 49-2307-438110
Northern Europe
Bishop’s Stortford, United Kingdom
Tel: 44-1279-460122
Espoo, Finland
Tel: 358-9-5406-5000
Asia
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Shenzhen, China
Tel: 86-755-2518-1306
Beijing, China
Tel: 86-10-5829-1711
Shanghai, China
Tel: 86-21-6447-0707
Taipei, Taiwan
Tel: 886-2-27528585
Southeast Asia
Singapore
Tel: 65-6586-1900
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
7© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com S6005_S01 • 3/7/2014
Bank Module Supercapacitors – S01 Series, Molded Plastic Cell Module
Disclaimer
All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are
not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use. The Information is intended for use only
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all productrelated warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
Prototype Sample Disclaimer
The Customer acknowledges the following limitations of the prototype samples:
(1) Prototype samples are manufactured from preliminary designs and manufacturing processes, may not represent nal designs, have not been released for
commercial use and are not subject to the same quality control procedures applicable to released products;
(2) Prototype samples are not qualied parts and are provided as-is by KEMET Electronics Corporation, which specically disclaims any and all warranties and
guarantees, explicit or implied, including without limitation the warranties of merchantability and tness for a particular purpose or use;
(3) Prototype samples are not intended for commercial use, are provided for engineering evaluation only and are not recommended for use in the Customer’s
production line; and
(4) The Customer assumes the risk of any and all uses that the Customer makes of the prototype samples.
Prototype Copyright Notice
COPYRIGHT KEMET ELECTRONICS CORPORATION 2013, all rights reserved
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
KEMET:
S01PM1205R080A