Ser GN SOLID STATE RELAYS FEATURES: = CE compliant (EMC and LVD) m@ UL and cUL recognized = Current ratings to 90A m@ AC or DC inputs = Dual back-to-back SCR @ Zero AC or random turn-on models @ Touch Safe m 4 kV optical isolation = LED status indicator DIMENSIONS mm ) > 7.60 3 4 #2 | 3 \ T - 10 + i k Yah mae 7 AC INPUT EQUIVALENT CIRCUIT 1 <28.00-__ 6.50> |___ 6.00 | ~*~ 60.60 90) | 45,00 > |=17.00->| |<17.00> | A I I 7 2 || + 4 || / o $ P YU U/ |S 2 ~a| Bat ik 8 tt a 4 2 | + g | 57.60. DC INPUT EQUIVALENT CIRCUIT Products and specifications subject to change without notice. Consult factory for application assistance. 3237 Commander, Carrollton, Texas 75006 / Tel: (972) 250-1647 / (800) 677-5311 / FAX: (972) 250-3865|Crouzet} SOLID STATE RELAYS OUTPUT (SCR) MODEL NUMBER OUTPUT CONTROL SPECIFICATIONS RATING ~ VOLTAGE l 84131001 | 84131101 | 10A ! 90-280 VAC 84131011 | 84131111 125A 1 90-280 VAC 84131021 | 84131121 1 50A ! 90-280 VAC 84131031 | 84131131 |! 75A ! 90-280 VAC ZERO VOLT 84131041 | 84131141 | 90A 1 90-280 VAC TURN-ON 84131000 | 84131100 | 10A : 432VDC 84131010 ! 84131110 ! 25A ! 4-32 VDC 84131020 ! 84131120 |! 50A \ 4-32 VDC 84131030 | 84131130 i 75A 4-32 VDC 84131040 1 84131140 + 9Q0A ' 4-32 VDC 84131201 | 84131301 | 10A { 90-280 VAC 84131211 | 84131311 ! 25A 1! 90-280 VAC 84131221 i 84131321 1 50A ! 90-280 VAC 84131231: 84131331 1. ..75A. | _ 90-280.VAC_| | 84131241 | 84131341 | 90A + 90-280 VAC | RANDOM -+|saT3T2z00 84131300 r Lue r 4232 VDOT TURN-ON 84131210 | 84131310 | 25A \ 4-32 VDC 84131220 | 84131320 | 50A 1 4-32 VDC 84131230 ' 84131330 ! 75A 4-32 VDC 84131240 | 84131340 | 90A \ 4-32 VDC Maximum line voltage (Vrms) \ 280 530 ' Minimum line voltage (Vrms) 24 i 36 Max. off-state voltage (vpeak)(2) ! +510 \ 1100 ! ! Max. off-state leakage (mArms){3) |! 2.0 i 4.0 I ' Static (off-state) dv/dt (V/us)(4) 1 500 ' 500 For higher current models consult factory INPUT SPECIFICATIONS: (1) PARAMETER AC CONTROL DC CONTROL Control Voltage 90-280 VAC 4-32 VDC Drop Out Voltage 10 Vrms 1 VDC Maximum Input Current (5) 9 mArms 10mA Normal Input Resistance Regulated Regulated -Turn-On Time 20 mS 8.33 mS (6) Turn-Off Time 30 mS 8.33 mS PARAMETER UNITS Maximum On-State Current (7) 10 25 50 75 90 Arms Minimum On-State Current 100 100 100 100 100 mArms Maximum 1-Cycle Surge (8) > 100 250 500 750 1000 Apeak Minimum 1-Second Surge (8) 40 75 135 200 280 Apeak On-State Voltage Drop (9) 1.6 1.6 1.6 1.6 1.6 Vpeak Pt (60 Hz, Half Cycle) 200 260 1040 . 2345 4165 Asec It (280 V Models) 200 260 2345 2345 4165 Asec Rjb 1.6 1.6 1.6 1.6 1.6 C/W GENERAL SPECIFICATIONS: PARAMETER All Devices Operating Temperature Range -20 to +80C Storage Temperature Range -40 to +100C Input to Output Isolation Voltage (10) ~ 4000 Vrms Input/Output to Ground Isolation Voltage 2500 Vrms Capacitance Input to Output (Typical) 8 pF Line Frequency Range 47 to 63 Hz Notes: (1) Specifications apply to Ta -30 to +80 unless otherwise noted (7) With relay properly mounted on an adequate heatsink. (2) One minute maximum duration If applied as a DC voltage. See G series thermal dissipation curves for proper heatsink size. (3) At Ta of 25C and maximum line voltage. (8) At Ta of 25C, non-repetitive resistive load. (4) Minimum dv/dt per EIA/NARM RS443, method RS397, 25C. (9) At Ta of 25C and maximum rated current. (8) At maximum input voltage (10) At Ta of 25C for one second, maximum 1 MA. (6) At 60 Hz 100 pS for random turn-on models (DC control only). Products and specifications subject to change without notice. Consult factory for application assistance. 3237 Commander, Carrollton, Texas 75006 / Tel: (972) 250-1647 / (800) 677-5311 / FAX: (972) 250-3865