https://www.phoenixcontact.com/us/products/2313355 Router-PSI-MODEM-GSM/ETH-2313355 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Industrial GSM router with GPRS/EDGE for mounting on EN DIN rail. GSM and GPRS/EDGE. 850 + 900 + 1800 + 1900 MHz. Ethernet interface. Firewall and VPN support. 6 alarm inputs and 4 switching outputs. 24 V DC supply voltage. Your advantages Configuration via web-based management Up to three VPN tunnels simultaneously Can be used worldwide Starting of VPN via call High electromagnetic compatibility Starting of VPN via SMS Authentication with X.509 certificates Firewall Encryption of SIM card PINs Autocrossing 10/100 Mbps automatic detection IPsec and OpenVPN support NAT table 6 digital switching inputs: for sending freely configurable text messages (SMS, FAX, e-mail) and starting user-defined functions Four switching outputs: can be activated via SMS and Ethernet and for GSM and connection diagnostics Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356438827 Weight per Piece (excluding packing) 286.100 g Custom tariff number 85176200 04/20/2021Page1/8 https://www.phoenixcontact.com/us/products/2313355 Router-PSI-MODEM-GSM/ETH-2313355 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 35 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -25 C ... 60 C Ambient temperature (storage/transport) -40 C ... 75 C Permissible humidity (operation) 30 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 30 % ... 95 % (non-condensing) Altitude 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) Degree of protection IP20 Noise immunity EN 61000-6-2:2005 General Electrical isolation VCC // GSM // Ethernet // PE Test voltage data interface/data interface 500 V (50Hz, 1min.) Test voltage data interface/power supply 500 V (50Hz, 1min.) Electromagnetic compatibility Conformance with R&TTE directive 1999/5/EC Mounting type DIN rail mounting Net weight 291 g Housing material PA 6.6-FR Color green Power supply Nominal supply voltage 24 VDC 5% (as an alternative or redundant, via backplane bus contact and system current supply) Supply voltage range 10 VDC ... 30 VDC (via pluggable COMBICON screw terminal block) Typical current consumption < 360 mA (24VDC) < 90 mA (stand by) Interfaces Interface 1 Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3 Interface Ethernet Connection method RJ45 jack, shielded 04/20/2021Page2/8 https://www.phoenixcontact.com/us/products/2313355 Router-PSI-MODEM-GSM/ETH-2313355 Technical data Interfaces Transmission length 100 m (shielded twisted pair) Protocols supported TCP/IP, UDP/IP, FTP, HTTP Auxiliary protocols ARP, DHCP, PING (ICMP), SNMP V1, SMTP Serial transmission speed 10/100 Mbps, auto negotiation Wireless interface Interface description GSM / GPRS / EDGE Frequency 850 MHz (2 W (EGSM)) 900 MHz (2 W (EGSM)) 1800 MHz (1W (EGSM)) 1900 MHz (1W (EGSM)) Data rate 210 kbps (EDGE) Antenna 50 impedance SMA antenna socket SIM interface 1 1.8 volt, 3 volt GPRS Class 12, Class B CS1 ... CS4 EDGE Multislot Class 10 Network function 4 time slots for receiving data, 4 time slots for transmitting data. The PIN is saved in the modem. After a voltage interruption, there is automatic redialing into the network. Integrated TCP/IP stack, firewall and VPN support, independent connection establishment. Network check LED to show data signal quality Function Web-based management yes Management Web-based management, SNMP Number of VPN tunnels 3 Security functions Supported 3DES, AES-128, -192, -256 ESP tunnel X.509v3, PSK MD5, SHA-1 RFC 3706 IP, port, protocol Digital outputs Output name Digital output Number of outputs 4 Voltage output signal 10 VDC ... 30 VDC (depending on the operating voltage) Current output signal 50 mA (Short-circuit-proof) Digital inputs Description of the input Digital input Number of inputs 6 Voltage input signal 10 VDC ... 30 VDC 04/20/2021Page3/8 https://www.phoenixcontact.com/us/products/2313355 Router-PSI-MODEM-GSM/ETH-2313355 Technical data Standards and Regulations Electromagnetic compatibility Conformance with R&TTE directive 1999/5/EC Type of test Free fall in acc. with IEC 60068-2-32 Test result 1m Type of test Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6 Test result 5g, 150 Hz, 1.5 h, in XYZ direction Type of test Shock in acc. with EN60068-2-27/IEC60068-2-27 Test result Operation: 15g, 11 ms period, half-sine shock pulse Type of test Shock in acc. with EN60068-2-27/IEC60068-2-27 Test result Storage: 30g, 11 ms period, half-sine shock pulse Noise immunity EN 61000-6-2:2005 Standards/regulations EN 61000-4-2 Contact discharge 6 kV Standards/regulations EN61000-4-3 Frequency range 80 MHz ... 3 GHz Standards/regulations EN61000-4-4 Comments Criterion A Standards/regulations EN61000-4-5 EN61000-4-6 Frequency range 0.15 MHz ... 80 MHz Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings 04/20/2021Page4/8 https://www.phoenixcontact.com/us/products/2313355 Router-PSI-MODEM-GSM/ETH-2313355 Connection diagram Dimensional drawing + 120 35 PSI-MODEM-GSM/ETH Ord.-No. 23 13 355 ALR NET DCD SIM O1 O2 24V 0V I1 I2 ANT 99 VCC RD TD AA VPN ACT LNK LAN I3 I4 I5 I6 O3 O4 Switching inputs Schematic diagram 1 2 Schematic diagram 3 24 V 0 V PSI-MODEM-GSM/ETH Ord.-No. 23 13 355 24V 0V I1 I2 O1 O2 I3 I4 I5 I6 O3 O4 O 1 2 O I2 I1 0V V 24 4 3 O O VCC RD TD ALR NET DCD SIM I6 I5 I4 I3 ANT AA VPN ACT LNK 4 Device connections LAN 5 Front view 04/20/2021Page5/8 https://www.phoenixcontact.com/us/products/2313355 Router-PSI-MODEM-GSM/ETH-2313355 Schematic diagram NE T DC D SIM B AA VP N AC T LN K NE T DC D SIM AA VP N AC T LN K LA N C A LA N Insert the SIM card Classifications eCl@ss eCl@ss 4.0 27230207 eCl@ss 4.1 27230207 eCl@ss 5.0 27230207 eCl@ss 5.1 19030100 eCl@ss 6.0 19060500 eCl@ss 7.0 19060590 eCl@ss 9.0 19060590 ETIM ETIM 2.0 EC000310 ETIM 3.0 EC000310 ETIM 4.0 EC000740 ETIM 6.0 EC000740 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 04/20/2021Page6/8 https://www.phoenixcontact.com/us/products/2313355 Router-PSI-MODEM-GSM/ETH-2313355 Classifications UNSPSC UNSPSC 13.2 43222628 UNSPSC 19.0 43222628 Accessories Accessories Antenna Antenna-PSI-GSM/UMTS-QB-ANT-2313371 GSM UMTS antenna, with omnidirectional characteristic, 2 m antenna cable with SMA round connector Antenna-TC ANT MOBILE WALL 5M-2702273 Multiband cellular antenna with mounting bracket for outdoor installation, 5m antenna cable with SMA circular connector, suitable for LTE/4G and 5G Coaxial cable Antenna cable-PSI-CAB-GSM/UMTS- 5M-2900980 Cellular antenna cable, 5m in length, SMA (male) -> SMA (female), 50ohm impedance Antenna cable-PSI-CAB-GSM/UMTS-10M-2900981 Cellular antenna cable, 10m in length, SMA (male) -> SMA (female), 50ohm impedance 04/20/2021Page7/8 https://www.phoenixcontact.com/us/products/2313355 Router-PSI-MODEM-GSM/ETH-2313355 Accessories DIN rail connector DIN rail bus connectors-ME 17,5 TBUS 1,5/ 5-ST-3,81 GN-2709561 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos. Power supply Power supply unit-MINI-SYS-PS-100-240AC/24DC/1.5-2866983 Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A Surge protection for transceiver systems Surge protection device-CSMA-LAMBDA/4-2.0-BS-SET-2800491 Attachment plug with Lambda/4 technology as surge protection for coaxial signal interfaces. Connection: Male/female SMA connectors. Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 04/20/2021Page8/8