Application
Specification
114-20021
Rev. D12
FASTIN-FASTON* Connectors, .110”, .250”, .312” & .375” srs.
TAB & RECEPTACLE CONTACTS
D12 UPDATED H.Y. 23 FEB 2009 G.T. 23 FEB 2009
D11 UPDATED H.Y. 13 DEC 2006 G.T. 13 DEC 2006
D10 ADDED P/N 293212 H.Y. 10 AUG 2006 G.T. 10 AUG 2006
D9 UPDATED H.Y. 18 JAN 2006 G.T. 18 JAN 2006
D8 UPDATED H.Y. 31 MAR 2005 G.T. 31 MAR 2005
rev letter rev. record DR Date CHK Date
DR. DATE
APVD DATE
H. YAALI 30 AUGUST 2001
C. TARTARI 30 AUGUST 2001
This specification is a controlled
document.
This information is confidential and is
disclosed to you on condition that no
further disclosure is made by you to other
than AMP personnel without written
authorization from AMP Italia.
Page 1 of 4
* Trademark of AMP Incorporated
LOC I
FTEC174 rev. 2 - July 99
1. SCOPE
This specification covers the requirements for application of .110”, .250”, .312” and .375” series FASTIN-
FASTON* Tab & Receptacle contacts. These requirements are applicable to automatic machine crimping
tools.
For specific wire and insulation ranges relative to the products covered in this specification, see Figure 4.
1.1 Reference Specification
For applicable performance requirements, see AMP Product Specification 108-20020.
2. NOMENCLATURE
Figure 1
3. CRIMP AND DIMENSIONAL REQUIREMENTS
3.1 Wire Preparation
A- Strip Length: Insulation shall be stripped as indicated in Figure 4.
B- Workmanship: Reasonable care shall be taken not to nick, scrape or cut any strands during the
stripping operation.
3.2 Carrier Cutoff Tab and Burr.
A- Cutoff Tab: Cutoff tab shall not exceed .015.
B- Burr: Burr on cutoff shall not exceed .005.