300 MHz Filter
Part Number
SF0300BA01973S
Micro Networks Corp., 324 Clark Street, Worcester, MA 01606, USA tel: 508-852-5400, fax:508-852-8456, www.micronetworks.com
Rev 1.1 26-Apr-02
Page 1 of 2
TYPICAL PERFORMANCE
Horizontal: 2 MHz/div Vertical (from top): 10 dB/div
1 dB/div
200 ns/div
SPECIFICATION
NOTE – All electrical specifications apply at room temperature (23 °C) only.
PARAMETER Min Typ Max Units
Center Frequency (FC) 1 299.935 300.010 300.085 MHz
Insertion Loss 2 15 19 dB
3dB Bandwidth 3 4 3.2 3.3 MHz
40dB Bandwidth 3 4 4.6 4.7 MHz
Ultimate rejection at FC +/-(6 to 40) MHz 445 50 dB
Average Passband Delay 1.67 1.8 µs
Passband Amplitude Ripple 3 5 0.75 1.0 dB p-p
Passband Group Delay Ripple 3 6 70 200 ns p-p
Passband Phase Linearity 3 6 310 deg p-p
Return Loss at Input and Output 3 6 10 dB
Triple Transit Suppression 40 46 dB
Source and Load Impedance 50 Ω
Frequency change with Temperature (TC ≈ 20 °C) -0.009(T-TC)2kHz / °C2
Operating Temperature Range -30 +70 °C
Storage Temperature Range -40 +85 °C
Notes:
1. Center frequency is defined as the mean of the upper and lower 3dB points. The typical room temperature center
frequency may be offset from 300 MHz to allow for frequency change with temperature.
2. Measured at the frequency at which the insertion loss is minimum.
3. All bandwidths are centered at FC.
4. Decibel level is relative to the insertion loss.
5. Over bandwidth FC +/- 1.2 MHz.
6. These parameters to be satisfied over the 3 dB bandwidth.