Solving your relay requirements since 1922
HDOD Series Delay-On-Dropout Time Delay Relay
Solid state CMOS digital circuitry
True delay on dropout: Timing cycle after power removal
DPDT (2 form C) isolated 4 ampere relay contacts
Built-in timing adjust potentiometer
Numerous models from 0.1 seconds to hours
Timing Mode
Upon the application of input voltage the relay immediately
energizes. The timing cycle begins when input voltage is removed.
When the timing cycle is complete, the relay will de-energize
TIMING DIAGRAM:
CONTACT INFORMATION
Arrangement: 2 form C (DPDT)
Contact material: Gold Clad Silver Alloy
Rating: Maximum Switching Power - 1000 VA, 90W
(Resistive);
Maximum Switching Voltage - 250V AC, 48V DC
Maximum Switching Current - 4 Amperes
Nominal Switching Capacity - 4A 250V AC, 3A 30V DC
UL/CSA Rating - 4 A 1/20 HP 125, 250V AC, 3A 30V DC
Expected Life @ 25°C
Mechanical: 100 Million operations
Electrical 100,000 operation at 4A 250V AC
200,000 operations at 3A 30V DC
ENVIRONMENTAL INFORMATION
temperature Range: Ambient: - 40°C to 65°C (-40° to +149°F)
OUTLINE DIMENSIONS
Solving your relay requirements since 1922
Timing Specifications
Fixed timing: 0.1 seconds to hour, tolerance 5%
consult factory for availability.
Adjustable Timing Ranges: .1 to 1 sec; 1 to 10 sec;
10 to 100 sec; 1 to 10 min; 10 to 100 min.
Availability of long delay time depends upon voltage;
consult factory for details.
INITIAL DIELECTRIC STRENGTH:
Between open contacts: 750V RMS
Between adjacent contacts: 1000V RMS
Between contacts & coil: 1500V RMS
INPUT INFORMATION
Voltage: 12, 24, 48, 120 volts AC or DC
Custom voltages are available
Power requirements: 2 VA or Watts
Transient: protection: 1 Joule MOV
Polarity protection DC units
INPUT VOLTAGES & LIMITS:
Nominal Minimum Maximum
10V 11V 15V
24V 20V 28V
48V 20V 28V
110V 41V 55V
120V 95V 125V
WRING DIAGRAM
MECHANICAL INFORMATION
Termination: 1/4 inch quick-connect male terminals
Enclosure: 21/2 by 3/4 inch, epoxy sealed
Single 1/4 inch hole flat panel mounting.
Solving your relay requirements since 1922
Ordering Information
HDOD Series Time Delay Relay
Example:
A: Denotes nominal input voltage. Voltages: 12, 24 and120V AC;
12, 24, 48, and 110V DC.
B: Denotes type of input power: A = AC, D = DC
C & D: Denotes timing range if knob adjustability. See Standard ranges.
For fixed units specify a single number. Costume timing available.
E: Denotes unit of time delay: S = seconds; M = minutes
H = hours
F: Denotes Amperite HDOD Series DPDT 4 ampere
delay-on-dropout TDR.