POWER ENTRY MODULES / GERATESTECKER-KOMBIELEMENTE 5145 Power entry module Type 5145 - Panel mount: screw-on version, front-side - Appliance inlet, circuit breaker type TA 45 and line filter Standard or Medical filter 50 Characteristics * Circuit breaker with line switch, 2-pole, non-illuminated or illuminated * Combined with thermal overload protection * Optional with undervoltage- or remote trip release * All single elements wired Unwired versions available on request Technical data Rated voltage Rated currents In1) Filter TA 45 Leackage current, Standard Medical Test voltage (2 sec) Allowable ambient air temperatures Ta Climatic category Degree of protection (front-side) Protection class Terminals Panel thickness s Materials: Housing 125/250 VAC; 50/60 Hz 1-10 A; @Ta 40 C; SEV, VDE, Semko 1-15 A; @Ta 40 C; UL, CSA 0,1-10 A; VDE, see table 1 0,1-15 A; UL/CSA, see table 1 < 0,5 mA (250 V/60 Hz) < 5 A (250 V/60 Hz) 1,7 kVDC between L-N 2,7 kVDC between L/N-PE -10 C to +55 C 10/055/21 acc. to IEC/EN 60068-1 IP 40 acc. to IEC 60529 suitable for equipment with prot. cl. I, acc. to IEC 61140 quick-connect 6,3 x 0,8 mm max. 8 mm Thermoplastic, black, UL94 V-0 Appliance-inlet acc. to. IEC/EN 60320-1/C14, Protection class I, pin-temperature 70 C (cold condition) Circuit breaker acc. to IEC/EN 60934, UL 1077, type TA45 CSA 22.2 no. 235. 2-pole rocker switch, illuminated or non-illuminated. Optional with undervoltage- or remote trip release Short circuit capacity Icn: at In < 3 A / 240 VAC: 10 x In at In 3 A / 240 VAC: 300 A Line filter, standard and medical acc. to. IEC 60939, EN 133 200, UL 1283, CSA C 22.2 no. 8 Technical details see page 202 1) Application note The rated current of the line filter must be equal or higher than the rated current of the circuit-breaker. 126 www.schurter.com 75 100 POWER ENTRY MODULES / GERATESTECKER-KOMBIELEMENTE Technical data (continued) Circuit breaker Tripping characteristics In < 3 A Tripping characteristics In 3... 15 A [ min ] [ sec ] 10'000 [ min ] [ sec ] 10'000 Type / Typ TA45 Rated current / Nennstrom In < 3 A 1 pole protected 60 2 pole protected 30 60 2000 30 20 1000 10 +23 C Type / Typ TA45 Rated current / Nennstrom In 3 A .... 15 A 1 pole protected 2 pole protected 1'000 10 500 5 Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. 2'000 20 Ambient temp. Umgebungstemp. 5145 Ambient temp. Umgebungstemp. +23 C 500 5 200 200 100 1 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 Tripping time Tripping time Ambient temperature / Umgebungstemperatur [C] -10 -5 0 +23 +30 +40 +55 100 1 50 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 Multiple of rated current / Nennstrom-Vielfaches 0,89 0,91 0,92 1,00 1,03 1,08 1,16 0,3 0,2 0,1 10 1,05 1,32 [ x In ] 2 3 4 5 8 Multiple of rated current 1) Correction factor 10 [ x In ] Example Rated current at +23 C Correction factor / Korrekturfaktor 6,0 A 1,08 Chosen rated current at +40 C ambient temperature Ambient temperature +40 C +40 C Umgebungstemperatur 6 A x 1,08 = 6,5 A Dimensions 13,5 0 o6 R3 0-0,5 72 0 80 +0,1 6,3 x 0,8 mm 91,5 29 +0,2 Detail a 2 1 3,25 43 Detail a 80 0,1 36 6,3 x 0,8 mm Mounting screw torque 0,5 Nm M3 / o 3,6 50,7 67,5* * Version TA45 with undervoltage release Diagrams Standard version / Standardversion Line Panel cut-out Medical version Load Line Load Technical data of filter-components Rated current / Nennstrom (A) 1 2 3 4 6 8 10 15 1 2 3 4 6 8 10 15 Filter-Type / Filter-Typ Standard Medical Inductance / Induktivitaten L1/L2 (mH) 2 x 11 2x4 2 x 2,5 2 x 1,6 2 x 0,7 2 x 0,6 2 x 0,4 2 x 0,1 2 x 11 2x4 2 x 2,5 2 x 1,6 2 x 0,7 2 x 0,6 2 x 0,4 2 x 0,1 Capacitance / Kapazitaten R CX (nF) CY (nF) (M) 47 2 x 2,2 - 47 - 1 www.schurter.com 127 POWER ENTRY MODULES / GERATESTECKER-KOMBIELEMENTE Attenuation loss Standard version 5145 Medical version differential mode common mode 1A 6A 1A 6A 2A 8A 2A 8A 3A 10 A 3A 10 A 4A 15 A 4A 15 A Order code (Order example) Type Order code TA45 (2-pole rocker-switch without accessories) Wiring 0 Without 1 With Type of line filter 1 Standard 3 Medical 5145 . A B T W F 1 5 0 C 0 see table 1 . 0 0 1 Rated current of line filter 1 1 (A) 2 2 (A) 3 3 (A) 4 4 (A) 5 6 7 8 6 (A) 8 (A) 10 (A) 15 (A) Please note that Schurter will establish an internal part number for logistical use in additional to the order code. The format of this internal part number is, for example 5145.0031.001 Application note The rated current of the line filter must be equal or higher than the rated current of the circuit-breaker 128 www.schurter.com POWER ENTRY MODULES / GERATESTECKER-KOMBIELEMENTE Table 1 Selection for type TA45 Order example ABT W F 150 C0 * Line switch * 2-pole, rocker actuated * Quick connect terminal Other types on request 5 3 P1 5145 a Diagram without / ohne Thermal overload protection Without illumination With illumination / Mit Beleuchtung 220...240 V 110...120 V with 1-pole P2 P1 P2 6 5 6 with 2-pole P1 P2 P1 3 4 3 ABC ABT ABD A02 A04 A12 A14 A32 A34 } Colours Switch front / W B 6 Rocker black / schwarz black / schwarz black / schwarz white / weiss black / schwarz - - - orange transp. Rocker legend printed / bedruckt OFF OFF L printed / bedruckt O K Illustration / Colour of print l O printed / bedruckt Surface / black white P printed / bedruckt I O white black R printed / bedruckt I M printed / bedruckt O black white O l H F l embossed ON Illustration / Colour of print ON Surface / Position of the rocker legend e.g F Rated current : * Without thermal overload protection: code C00 }I n = 16 A * With thermal overload protection: rated current In (A) In Code In Code In Code In Code 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,5 J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 J25 2,8 3,0 3,5 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 9,0 J28 030 035 040 045 050 060 065 070 075 080 090 10,0 11,0 12,0 13,0 14,0 15,0 100 110 120 130 140 150 Without release: code C0 Undervoltage release P2 P1 U< Remote trip release P2 b U< P1 P2 ba P1 P2 c P1 U< Rated voltage Un U E Z A Code * * * * 2 240 V AC * * * * 3 230 V AC * * * * 4 120 V AC www.schurter.com 129