SFH 5140 F
SFH 5141 F
Schmitt-Trigger IC im Mini-Sidelooker Gehäuse mit Linse
Schmitt-Trigger IC in Miniature Sidelooker Package with Lens
Lead (Pb) Free Product - RoHS Compliant
2007-04-03 1
Wesentliche Merkmale
Integrierter Schmitt-Trigger
•SFH 5140 F: Output active low
•SFH 5141 F: Output active high
Miniatur-Gehäuse
Anwendungen
Optischer Schalter
•Pulsformer
Zähler
Empfänger in Lichtschranken
Typ
Type
Bestellnummer
Ordering Code
SFH 5140 F Q62702P5112
SFH 5141 F Q62702P5113
Features
Built-in Schmitt Trigger circuit
•SFH 5140 F: Output active low
•SFH 5141 F: Output active high
Compact package
Applications
Optical threshold switch
•Pulseformer
Counter
Receiver in interrupters
2007-04-03 2
SFH 5140 F, SFH 5141 F
Zur Stabilisierung der Versorgung wird ein Stützkondensator (angeschlossen zwischen VCC und GND) von typ. 0.1 µF
empfohlen.
A bypass capacitor, 0.1 µF typical, connected between VCC and GND is recommended in order to stabilize power supply
line.
Grenzwerte (TA = 25 °C)
Maximum Ratings
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
Betriebs- und Lagertemperatur
Operating and storage temperature range
Top; Tstg – 40+ 85 °C
Versorgungsspannung
Supply voltage
VCC – 0.5+ 20 V
Ausgangsspannung
Output voltage
VO– 0.5+ 20 V
Ausgangsstrom
Output current
IO 50 mA
Verlustleistung
Power dissipation
Ptot 175 mW
Empfohlener Arbeitsbereich
Recommended Operating Conditions
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
Versorgungspannung
Supply voltage
VCC 4 … 18 V
Ausgangsstrom
Output current
IO< 16 mA
Kennwerte (TA = 25 °C, VCC = 5 V)
Characteristics
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
Ausgangsspannung „high“
Output voltage “high”
IO = 0
VOH VCC (> 4.0) V
Ausgangsspannung „low“
Output voltage “low”
IO = 16 mA
VOL 0.15 (< 0.4) V
SFH 5140 F, SFH 5141 F
2007-04-03 3
Stromaufnahme
Supply current
VCC = 5 V
VCC = 18 V
ICC
3.3 (< 5)
5.0
mA
Hysterese
Hysteresis
Ee, OFF/Ee, ON 0.6
(0.5 … 0.9)
Halbwinkel
Half angle
ϕ ± 12 Grad
degr.
Anstiegszeit 10% bis 90%
Rise time 10% to 90%
RL = 280 , Ee = 90 µW/cm2, λ = 950 nm
tr 100 ns
Abfallzeit 90% bis 10%
Fall time 90% to 10%
RL = 280 , Ee = 90 µW/cm2, λ = 950 nm
tf 100 ns
Ausgangsverzögerungszeit
Propagation delay time “H” “L”
RL = 280 , Ee = 90 µW/cm2, λ = 950 nm
tPHL 5 (< 15) µs
Ausgangsverzögerungszeit
Propagation delay time “L” “H”
RL = 280 , Ee = 90 µW/cm2, λ = 950 nm
tPLH 5 (< 15) µs
Die Schmitt-Trigger ICs werden nach ihrer Schaltschwelle gruppiert und mit arabischen Ziffern
gekennzeichnet.
The schmitt-triggers ICs are grouped according to their threshold and distinguished by arabian
figures.
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
1 2 3 4 5
Schaltschwelle, λ = 950 nm
Threshold
SFH 5140 F: “H” “L”
SFH 5141 F: “L” “H”
Ee, ON 4 ... 8 6.3 ...12.5 10 ... 20 16 ... 32 25 ... 50 µW/
cm2
Kennwerte (TA = 25 °C, VCC = 5 V)
Characteristics (cont’d)
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
2007-04-03 4
SFH 5140 F, SFH 5141 F
Figure 1 Block Diagram
Figure 2 Test Circuit for Switching and Response Time
Figure 3 Switching Time Definitions
OHF00518
-
+
Voltage
Regulator
CC
V
OUT
GND
+
-
Regulator
Voltage
GND
OUT
CC
V
10 k
10 k
SFH 5141 F (Active “High”) SFH 5140 F (Active “Low”)
OHF00520
CC
V
OUT
GND
R
= 47
Input
L
R
= 280
µF
C
= 0.1
CC
V
OUT
GND
= 5 V
SFH 5140 F
SFH 5141 F
SFH 5140 F (Active “Low”)
OHF00519
PHL
t tPLH
50%
t
ftr
50%
90%
10%
Input
Output Output
Input
t
PHL
50%
PLH
t
tr f
t
10%
50%
90%
SFH 5141 F (Active “High”)
SFH 5140 F, SFH 5141 F
2007-04-03 5
Relative Threshold
Ee,ON/Ee,ON (Vcc = 5 V) = f (VCC)
Output Voltage
VOL = f (IOUT, VCC)
OHF00507
0.5 0 5 10 15 20
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.5
V
E
V
CC
e, ON
E
e, ON_5 V
OHF00512
0010
20 30 40 50mA
5 V
OUT
I
0.5
1
1.5
2
2.5
3
3.5
OL
V
V
10 V
15 V
20 V
Supply Current
ICC = f (VCC)
Supply Current vs. Ambient
Temperature ICC = f (TA, VCC)
OHF00510
00 5 10 15 20
V
1
2
3
4
mA
6
CC
I
V
CC
OHF00514
0
-25
1
2
3
4
mA
6
CC
I
A
T
0 25 50 75 100˚C
CC
V
= 5 V
5
= 10 V
CC
V
= 20 V
V
CC
= 15 V
V
CC
Total Power Dissipation
Ptot = f (TA)
OHF00511
00
tot
P
A
T
20 40 60 80 ˚C 100
20
40
60
80
100
120
140
160
200
mW
2007-04-03 6
SFH 5140 F, SFH 5141 F
Maßzeichnung
Package Outlines
Maße in mm (inch) / Dimensions in mm (inch).
GEOY6001
2.9 (0.114)
3.1 (0.122)
(0.5 (0.020) x 45˚)
0.85 (0.033)
1.05 (0.041)3.9 (0.154)
4.1 (0.161) 17.27 (0.680)
17.77 (0.700)
1.27 (0.050)
2.54 (0.100)
0.4 (0.016)
0.6 (0.024)
GND OUT
VCC
V
0.66 (0.026)
0.86 (0.034)
0.84 (0.033)
1.04 (0.041)
0.9 (0.035)
0.7 (0.028)
1.4 (0.055)
1.6 (0.063)
1.3 (0.051)
1.1 (0.043)
R0.7 (0.028)
R0.9 (0.035)
(60˚)
2.5 (0.098)
1.27 (0.050)
0.5 (0.020)
0.3 (0.012)
0.5 (0.020)
3.0 (0.118)
2.8 (0.110)
2.2 (0.087)
2.0 (0.079)
SFH 5140 F, SFH 5141 F
2007-04-03 7
Lötbedingungen
Soldering Conditions
Wellenlöten (TTW) (nach CECC 00802)
TTW Soldering (acc. to CECC 00802)
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components 1 may only be used in life-support devices or systems 2 with the express written approval of OSRAM OS.
1 A critical component is a component used in a life-support device or system whose failure can reasonably be expected
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2 Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
OHLY0598
0
0
50 100 150 200 250
50
100
150
200
250
300
T
t
C
s
235 C
10 s
C... 260
1. Welle
1. wave
2. Welle
2. wave
5 K/s 2 K/s
ca 200 K/s
CC... 130100
2 K/s Zwangskühlung
forced cooling
Normalkurve
standard curve
Grenzkurven
limit curves