FieldIT Data Sheet SS/268XS_2 2600T Series Pressure Transmitters Model 268DS Differential Model 268PS Gauge Model 268VS Absolute maximum working pressure up to 21MPa, 3045psi TUV SIL2 certified to IEC 61508/ISA S84.01 - the smart solution in Safety loop application Base accuracy : 0.075% Span limits - 0.14 to 16000kPa; 0.56inH2O to 2320psi - 0.27 to 16000kPa abs; 2mmHg to 2320psia Reliable sensing system coupled with very latest digital technologies - provides large turn down ratio up to 100:1 Hardware and software redundancy with MTBF of over 100 years Comprehensive sensor choice - optimize in-use total performance and stability 5-year stability Flexible configuration facilities - via hand held terminal or PC configuration platform HART(R) communication - provides integration with HART(R) platforms Full compliance with PED Category IV - suitable for safety accessory application ABB 2600T Series Engineered solutions for all applications 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 Functional Specifications Range and span limits Sensor Code Lower Range Limit (LRL) Upper Range Limit (URL) 268DS differential 268PS gauge Minimum span 268VS absolute 268DS differential 268PS gauge B 4kPa 40mbar 16inH2O -4kPa -40mbar -16inH2O -4kPa -40mbar -16inH2O E 16kPa 160mbar 64inH2O -16kPa -160mbar -64inH2O -16kPa -160mbar -64inH2O 0.07kPa abs 0.7mbar abs 0.5mmHg 0.27kPa 2.7mbar 1.08inH2O 0.27kPa 2.7mbar 2mmHg F 40kPa 400mbar 160inH2O -40kPa -400mbar -160inH2O -40kPa -400mbar -160inH2O 0.07kPa abs 0.7mbar abs 0.5mmHg 0.4kPa 4mbar 1.6inH2O 0.67kPa 6.7mbar 5mmHg G 65kPa 650mbar 260inH2O -65kPa -650mbar -260inH2O -65kPa -650mbar -260inH2O 0.07kPa abs 0.7mbar abs 0.5mmHg 0.65kPa 6.5mbar 2.6inH2O 1.1kPa 11mbar 8mmHg H 160kPa 1600mbar 642inH2O -160kPa -1600mbar -642inH2O 1kPa abs 10mbar abs 0.15 psia 0.07kPa abs 0.7mbar abs 0.5mmHg 1.6kPa 16mbar 6.4inH2O 2.67kPa 26.7mbar 20mmHg M 600kPa 6bar 87psi -600kPa -6bar -87psi 1kPa abs 10mbar abs 0.15 psia 0.07kPa abs 0.7mbar abs 0.5mmHg 6kPa 0.06bar 0.87psi 10kPa 0.1bar 1.45psi P 2400kPa 24bar 348psi -2400kPa -24bar -348psi 1kPa abs 10mbar abs 0.15 psia 0.07kPa abs 0.7mbar abs 0.5mmHg 24kPa 0.24bar 3.5psi 40kPa 0.4bar 5.8psi Q 8000kPa 80bar 1160psi -8000kPa -80bar -1160psi 1kPa abs 10mbar abs 0.15 psia 0.07kPa abs 0.7mbar abs 0.5mmHg 80kPa 0.8bar 11.6psi 134kPa 1.34bar 19.4psi S 16000kPa 160bar 2320psi -16000kPa -160bar -2320psi 1kPa abs 10mbar abs 0.15 psia 0.07kPa abs 0.7mbar abs 0.5mmHg 160kPa 1.6bar 23.2psi 267kPa 2.67bar 38.7psi Span limits Maximum span = URL (can be further adjusted up to URL (TD = 0.5) for differential models, within the range limits) IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. 0.14kPa 1.4mbar 0.56inH2O Damping Selectable time constant : 0, 0.25, 0.5, 1, 2, 4, 8 or 16s. This is in addition to sensor response time Turn on time Operation within specification in less than 5s with minimum damping. Insulation resistance Zero suppression and elevation Zero and span can be adjusted to any value within the range limits detailed in the table as long as: - calibrated span minimum span 2 268VS absolute > 100M at 1000VDC (terminals to earth) 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 Operative limits Environmental limits Temperature limits C (F) : Electromagnetic compatibility (EMC) Ambient (is the operating temperature) Models 268DS - 268PS Model 268VS Sensors Sensors Sensors Sensor F to S B to E F to S code E Silicone -40 and +85 -25 and +85 -40 and +85 -15 and +70 (-40 and +185) (-13 and +185) (-40 and +185) (+5 and +158) oil -20 and +85 -10 and +85 -10 and +65 Inert not applicable (-4 and +185) (+14 and +185) (+14 and +150) Galden -20 and +85 -10 and +85 -10 and +65 Inert not applicable Halocarbon (-4 and +185) (+14 and +185) (+14 and +150) Filling Lower ambient limit for LCD indicators: -20C (-4F) Upper ambient limit for LCD indicators: +70C (+158F) Note : For Hazardous Atmosphere applications see the temperature range specified on the certificate/approval relevant to the aimed type of protection Comply with EN 61000-6-3 for emission and EN 61000-6-2 for immunity requirements and test; Radiated electromagnetic immunity level: (according to IEC 1000-4-3, EN61000-4-3) 30V/m Conducted electromagnetic immunity level : (according to IEC 1000-4-6, EN 61000-4-6) 30V Surge immunity level (with surge protector): (according to IEC 1000-4-5 EN 61000-4-5) 4kV Fast transient (Burst) immunity level: (according to IEC 1000-4-4 EN 61000-4-4) 4kV Pressure equipment directive (PED) Comply with 97/23/EEC Category IV Modules D and B. Humidity Relative humidity: up to 100% annual average Condensing, icing: admissible Process Lower limit - refer to lower ambient limits; -20C (-4F) for Viton gasket Vibration resistance Accelerations up to 2g at frequency up to 1000Hz (according to IEC 60068-2-26) Upper limit - Silicone oil: 121C (250F) (1) - Inert fluid: 100C (212F) (2) (1) 100C (212F) for application below atmospheric pressure (2) 65C (150F) for application below atmospheric pressure Shock resistance Acceleration: 50g Duration: 11ms (according to IEC 60068-2-27) Wet and dust-laden atmospheres Storage Lower limit: -50C (-58F); -40C (-40F) for LCD indicators Upper limit: +85C (+185F) Pressure limits Overpressure limits (without damage to the transmitter) 0.067kPa abs, 0.67mbar abs, 0.01psia (double with inert filling) to - 7MPa, 70bar, 1015psi for sensor code B - 16MPa, 160bar, 2320psi for sensor code E - 21MPa, 210bar, 3045psi for sensor codes F to S Static pressure Transmitters for differential pressure model 268DS operates within specifications between the following limits The transmitter is dust and sand tight and protected against immersion effects as defined by EN 60529 (1989) to IP 67 (IP 68 on request) or by NEMA to 4X or by JIS to C0920. Hazardous atmospheres With or without output meter - INTRINSIC SAFETY/EUROPE: ATEX/TUV approval II 1 G T50C, EEx ia IIC T5 (-40C Ta +40C) T95C, EEx ia IIC T4 (-40C Ta +85C) - FLAMEPROOF/EUROPE: ATEX/CESI approval II 1/2 GD T85C, EEx d IIC T6 (-40C Ta +75C) - FACTORY MUTUAL: - Explosionproof: Class I, Div. 1, Groups A, B, C, D - Dust ignitionproof : Class II, Div. 1, Groups E, F, G - Suitable for : Class II, Div. 2, Groups F, G; Class III, Div. 1, 2 - sensor code B: 1.3kPa abs,13mbar abs, 0.2psia and 7MPa, 70bar, 1015psi - sensor code E: 1.3kPa abs,13mbar abs, 0.2psia and 16MPa, 160bar, 2320psi - sensor codes F to S: 1.3kPa abs,13mbar abs, 0.2psia and 21MPa, 210bar, 3045psi Proof pressure The transmitter can be exposed without leaking to line pressure of up to 48MPa, 480bar, 6960psi. Meet ANSI/ISA-S 82.03 hydrostatic test requirements and SAMA PMC 27.1. 3 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 Electrical Characteristics and Options Optional surge protection HART digital communication and 4 to 20mA output Power Supply Up to 4kV - voltage 1.2 s rise time / 50 s delay time to half value - current 8 s rise time / 20 s delay time to half value The transmitter operates from 10.5 to 42VDC with no load and is protected against reverse polarity connection (additional load allows operations over 42VDC). For EEx ia and other intrinsically safe approval power supply must not exceed 30VDC. Output signal Two-wire 4 to 20mA, user-selectable for linear or square root output, power of 3/2 or 5/2, 5th order or two 2nd order switching point selectable programmable polynomial output. HART(R) communication provides digital process variable (%, mA or engineering units) superimposed on 4 to 20mA signal, with protocol based on Bell 202 FSK standard. Ripple 20mV max on a 250 load as per HART specifications Output current limits (to NAMUR standard) MINIMUM OPERATING VOLTAGES Overload condition no link on output indicator plugs - Lower limit: 3.8mA with CoMeter indicator and HART communication - Upper limit: 20.5mA with ProMeter output indicator Transmitter failure mode (to NAMUR standard) with optional surge protection The output signal can be user-selected to a value of 3.7 or 22mA on gross transmitter failure condition, detected by self-diagnostics. with optional output analog indicator In case of CPU failure the output is driven <3.7mA or >22mA. (volts) 10.7 12.3 12.5 13.3 15.3 Load limitations 4 to 20mA and HART total loop resistance : Supply voltage - min. operating voltage (VDC) --------------------------------------- 22.5 A minimum of 250 is required for HART communication. R(k) = Optional indicators Output meter CoMeter and Prometer LCD : 5-digit (99999 counts) programmable with 7.6mm. high (3in), 7-segment numeric characters plus sign and digital point for digital indication of output value in percentage, current or engineer unit; 10-segment bargraph display (10% per segment) for analog indication of output in percentage; 7-digit with 6mm. high (2.3in), 14-segment alphanumeric characters, for engineer units and configuration display Analog : 36mm (1.4in) scale on 90. 4 2600T Pressure Transmitters Model 268DS, 268PS, 268VS Performance specifications Stated at reference condition to IEC 60770 ambient temperature of 20C (68F), relative humidity of 65%, atmospheric pressure of 1013hPa (1013mbar), mounting position with vertical diaphragm and zero based range for transmitter with isolating diaphragms in AISI 316 L ss or Hastelloy and silicone oil fill and HART digital trim values equal to 4-20mA span end points, in linear mode. SS/268XS_2 Operating influences Ambient temperature per 20K (36F) change between the limits of -20C to +65C (-4 to +150F) : Model Unless otherwise specified, errors are quoted as % of span. Some performance data are affected by the actual turndown (TD) as ratio between Upper Range Limit (URL) and calibrated span. IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. Dynamic performance (according to IEC 61298-1 definition) Dead time: 40ms Time constant (63.2% of total step change): - sensors M to S: 70ms - sensor H: 100ms - sensor G: 130ms - sensor F: 180ms Response time (total) = dead time + time constant Accuracy rating % of calibrated span, including combined effects of terminal based linearity, hysteresis and repeatability. 268DS 268PS 268VS Sensor Code for TD up to E to S 15:1 (0.04% URL + 0.065% span) B E to S 10:1 10:1 (0.06% URL + 0.10% span) (0.08% URL + 0.13% span) Optional CoMeter and ProMeter ambient temperature Total reading error per 20K (36F) change between the ambient limits of -20 and +70C (-4 and +158F) : 0.15% of max span (16mA). Static pressure (zero errors can be calibrated out at line pressure) per 2MPa, 20bar or 290psi (sensor code B) per 7MPa, 70bar or 1015psi (sensor codes E to S) Model 268DS - zero error: 0.08% of URL - span error: 0.08% of reading Multiply by 2 the errors for sensor code E. Supply voltage Within voltage/load specified limits the total effect is less than 0.005% of URL per volt. Model 268DS, 268PS - 0.075% for TD from 1:1 to 15:1 (0.10% for sensor code B for TD from 1:1 to 10:1) Load URL - 0.005% x Span Radio frequency interference (0.01% x URL Span for TD from 15:1 to 60:1 (30:1 for sensor code E) for sensor code B for TD from 10:1 to 20:1) Models 268VS - 0.075% for TD from 1:1 to 10:1 URL - 0.0075% x Span for TD from 10:1 to 20:1 Within load/voltage specified limits the total effect is negligible. Total effect : less than 0.10% of span from 20 to 1000MHz and for field strengths up to 30V/m when tested with shielded conduit and grounding, with or without meter. Common mode interference No effect from 100Vrms @ 50Hz, or 50VDC Mounting position Rotations in plane of diaphragm have negligible effect. A tilt to 90 from vertical causes a zero shifts up to 0.5kPa, 5mbar or 2inH2O, which can be corrected with the zero adjustment. No span effect. Stability 0.10% of URL over a thirty-six-month period Vibration effect 0.10% of URL (according to IEC 61298-3) 5 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 Physical Specification Optional extras (Refer to ordering information sheets for variant availability related to specific model or versions code) Mounting brackets For vertical and horizontal 60mm. (2in) pipes or wall mounting. Materials Output indicator Process isolating diaphragms (*) plug-in rotatable type, LCD or analog. AISI 316 L ss; Hastelloy C276TM; Monel 400TM; Tantalum; Hastelloy C276TM on AISI 316 L ss gasket seat. Process flanges, adapters, plugs and drain/vent valves (*) AISI 316 L ss; Hastelloy C276TM; Monel 400TM. Blind flange (reference side of 268PS, 268VS) AISI 316 L ss. Sensor fill fluid Silicone oil (DC200); inert fill (HalocarbonTM 4.2 or GaldenTM). Mounting bracket (**) Zinc plated carbon steel with chrome passivation; AISI 316 L ss. Supplemental customer tag AISI 316 ss tag screwed/fastened to the transmitter for customer's tag data up to a maximum of 20 characters and spaces on one line for tag number and tag name, and up to a maximum of 3 spaced strings of 10 characters each for calibration details (lower and upper values plus unit). Special typing evaluated on request for charges. Surge protection Cleaning procedure for oxygen service Hydrogen or special service preparation Test Certificates (test, design, calibration, material traceability) Tag and manual language Communication connectors Gaskets (*) VitonTM; PTFE. Sensor housing AISI 316 L ss. Bolts and nuts AISI 316 ss bolts Class A4-80 and nuts Class A4-70 per UNI 7323 (ISO 3506); AISI 316 ss bolts and nuts Class A4-50 per UNI 7323 (ISO 3506), in compliance with NACE MR0175 Class II. Electronic housing and covers Barrel version - Copper-free content aluminium alloy with baked epoxy finish; - Low-copper content aluminium alloy with baked epoxy finish; - AISI 316 L ss. DIN version - Low-copper content aluminium alloy with baked epoxy finish. Covers O-ring Buna N. Local zero and span adjustments: Glass filled polycarbonate plastic (removable). Tagging AISI 316ss data plate attached to the electronics housing. Calibration Standard: at maximum span, zero based range, ambient temperature and pressure; Optional: at specified range and ambient conditions. 6 Process connections on flanges : 1/4in NPT on process axis on adapters : 1/2in NPT on process axis centre distance (268DS): 54mm (2.13in ) on flange; 51,54 or 57mm (2.01, 2.13 or 2.24in) as per adapters fittings fixing threads: 7/16in-20 UNF at 41.3mm centre distance Electrical connections Two 1/2 NPT or M20x1.5 or PG 13.5 or 1/2 GK threaded conduit entries, direct on housing. Special communication connector (on request) - HART : straight or angle Harting Han connector and one plug. Terminal block HART version: three terminals for signal/external meter wiring up to 2.5mm2 (14AWG) and three connection points for test and communication purposes. Grounding Internal and external 6mm2 (10AWG) ground termination points are provided. Mounting position Transmitter can be mounted in any position. Electronics housing may be rotated to any position. A positive stop prevents over travel. Mass (without options) 3.5kg approx (8lb); add 1.5kg (3.4lb) for AISI housing. Add 650g (1.5lb) for packing. Packing Carton 26 x 26 x 18cm approx (10 x 10 x 7in). 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 Configuration Transmitter with HART communication and 4 to 20 mA Standard configuration Transmitters are factory calibrated to customer's specified range. Calibrated range and tag number are stamped on the tag plate. If a calibration range and tag data are not specified, the transmitter will be supplied with the plate left blank and configured as follows: Engineering Unit Specify from table 4 mA Zero 20 mA Upper Range Limit (URL) Output Linear Damping 1 sec. Transmitter failure mode Upscale Software tag characters Blank Optional LCD indicator/display 0 to 100.0% linear Any or all the above configurable parameters, including Lower range-value and Upper range-value which must be the same unit of measure, can be easily changed using the HART hand-held communicator or by a PC running the configuration software SMART VISION with DTM for 2600T. The transmitter database is customized with specified flange type and material, O-ring and drain/vent materials and meter code option. Custom configuration (option) The following data may be specified in addition to the standard configuration parameters: Descriptor 16 alphanumeric characters Message 32 alphanumeric characters Date Day, month, year For any protocol available engineering units of pressure measure are : Pa, kPa, MPa inH2O@4C, mmH2O@4C, psi inH2O@20C, ftH2O@20C, mmH2O@20C inHg, mmHg, Torr g/cm2, kg/cm2, atm mbar, bar TM Hastelloy is a Cabot Corporation trademark TM Monel is an International Nickel Co. trademark TM DC 200 is a Dow Corning Corporation trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark TM Viton is a Dupont de Nemour trademark (*) Wetted parts of the transmitter. (**) U-bolt material: AISI 400 ss; screws material: high-strength alloy steel or AISI 316 ss. MOUNTING DIMENSIONS (not for construction unless certified) - dimensions in mm (in) Transmitter with flanges for vertical connection (Barrel housing) Adjustments 17 (0.67) Identification tag 127 (5.00) 36 (1.42) Electrical connections 86 (3.39) Barrel type housing 17 (0.67) Certification label N IO L ES C C I R IR C U S ON T S O I TS AL I V U S T E E CU T S I NS Min. clearance to remove the cover E RC L E B I E UV ER T N FER V I GH M CO E P CO T E Drain/vent Valve + 83 (3.27) Output meter housing 185 (7.28) G A RD ER KE L E T QU AN E' T H E N W ! Terminal side Electronic side 54 (2.13) 86 (3.39) 71 (2.80) 62 (2.44) 33 (1.30) Adapter 41.3 (1.63) 74 (2.91) Process connection 7 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 Transmitter with barrel aluminium housing on bracket for vertical or horizontal 60mm (2in) pipe mounting Adjustments 17 (0.67) 127 (5.00) Min. clearance to remove the cover 17 (0.67) 127 (5.00) 36 (1.42) 17 (0.67) Certification label 135 (5.31) Terminal side 135 (5.31) Output meter housing Drain/vent Valve + + 82 (3.23) Electronic side Identification tag Barrel type 36 (1.42) 17 (0.67) housing 82 (3.23) Process connection 54 (2.13) (*) 86 (3.39) 86 (3.39) 71 (2.80) Model 268VS 62 (2.44) 71 (2.80) 62 (2.44) (*) FOR MODEL 268DS 51 (2.01), 54 (2.13) or 57 (2.24) mm (in) according to 1/2in 14 NPT adapters fitting; 54 (2.13) mm (in) on 1/4in 18 NPT process flange FOR MODEL 268PS 54 (2.13) mm (in) with low pressure side flange without process connection (a filter is fitted) and drain/vent valve Electrical connections 86 (3.39) Covers locking screw N IO G A RD ER KE L 63 (2.48) 108 (4.25) E RC L E B I E UV ER T N FER V I GH M CO E P CO T E 167 (6.57) S ON T S O I TS AL I V U S T E E CU T S I E T QU AN E' T H E N W ! E RC L E B I E UV ER T N FER V I GH M CO E P CO T E G A RD ER KE L 11 (0.43) N IO L ES C C I R IR C U ! NS E T QU AN E' T H E N W L ES C C I R IR C U NS S ON T S O I TS AL I V U S T E E CU T S I Flange 102 (4.02) 41.3 (1.63) 66 (2.60) with plug 78 (3.07) with d/v valve Adapter 82 (3.23) 84 (3.31) 108 (4.25) NOTE : Process connection, gasket groove and gaskets are in accordance with DIN 19213. Bolting threads for fixing adapter or other devices (i.e. manifold etc.) on process flange is 7/16in - 20 UNF. 8 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 Transmitter on bracket for vertical or horizontal 60 mm (2in) pipe mounting (DIN housing) 179 (7.05) Electrical connections 63 (2.48) 41.3 (1.63) 108 (4.25) 17 (0.67) 148 (5.83) 36 (1.42) L ES C C I R IR C U E T QU AN E' T H E N W Covers locking screw Identification tag 16 (0.63) 17 (0.67) Electronic side G A RD ER KE L Certification label Harting Han connector S ON T S O U AL I VE S T E ! Flange I TS CU T S I N IO Adjustments 7 (0.28) NS Output meter housing 86 (3.39) 55 (2.17) max 33 Adapter 51 (2.01) (1.30) External ground E RC L E B I E UV ER T N FER V I GH M CO E P CO T E DIN type housing 142 (5.59) Terminal side 82 (3.23) Certification label Drain/vent Valve Transmitter with barrel AISI ss housing on bracket (flat type for box) for vertical or horizontal 60mm (2in) pipe mounting N IO L ES C C I R IR C U NS S ON T S O I TS AL I V U S T E E CU T S I G A RD ER KE L E T QU AN E' T H E N W ! E RC L E B I E UV ER T N FER V I GH M CO E P CO T E 84 (3.31) 70 (2.75) 204 (8.03) + 25 (0.98) 70 (2.75) 47 (1.85) 98 (3.86) 9 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 Transmitter on bracket for wall mounting (by four M8 screws) S ON T S O I TS AL I V U S T E E CU T S I G A RD ER KE L L ES C C I R IR C U 70 (2.75) 70 (2.75) 25 (1) ! E T QU AN E' T H E N W N IO E RC L E B I E UV ER T N FER V I GH M CO E P CO T E NS 70 (2.75) Electrical connections HART Version Internal ground termination point M+ - 0 2 3 4 7 6 5 9 60 40 20 0 Remote indicator 8 10 80 % 10 0 Kent-Taylor Line load M + 3 4 2 8 1 7 5 6 Harting pin (male) identification + + 250 ohm min GND TEST COMM - 691HT External ground termination point F1 F2 + Test points 4 to 20mA F3 CONF SERIAL LINK TRIM A B C Hand-held communicator - F4 PV REVIEW - + Power source D E F 2 3 M N O P Q R 4 5 6 S T U V W X Y Z # 7 8 9 @ % & / + - 0 Optional G H I 1 J K L Receiver HART hand-held communicator may be connected at any wiring termination point in the loop, providing the minimum resistance is 250 ohm. If this is less than 250 ohm, additional resistance should be added to allow communications 10 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 BASIC ORDERING INFORMATION model 268DS Safety Differential Pressure Transmitter Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required. BASE MODEL - 1st to 5th characters 2 6 8 D S X S X X X X X Safety Differential Pressure Transmitter - BASE ACCURACY 0.075% SENSOR - Span limits - 6th character 0.14 and 4kPa 1.4 and 40mbar 0.27 and 16 kPa 2.7 and 160mbar 0.4 and 40kPa 4 and 400mbar 0.65 and 65kPa 6.5 and 650mbar 1.6 and 160kPa 16 and 1600mbar 6 and 600kPa 0.06 and 6bar 24 and 2400kPa 0.24 and 24bar 80 and 8000kPa 0.8 and 80bar 160 and 16000kPa 1.6 and 160bar B E F G H M P Q S 0.56 and 16inH2O 1.08 and 64inH2O 1.6 and 160inH2O 2.6 and 260inH2O 6.4 and 642inH2O 0.87 and 87psi 3.5 and 348psi 11.6 and 1160psi 23.2 and 2320psi Use code - 7th character Diaphragm material / Fill fluid (wetted parts) - 8th character AISI 316 L ss Silicone oil Hastelloy C276TM (on AISI seat) Silicone oil Hastelloy C276TM Silicone oil Silicone oil Monel 400TM Silicone oil Tantalum AISI 316 L ss Inert fluid - Galden Hastelloy C276TM (on AISI seat) Inert fluid - Galden Inert fluid - Galden Hastelloy C276TM Monel 400TM Inert fluid - Galden Inert fluid - Galden Tantalum Inert fluid - Halocarbon AISI 316 L ss Hastelloy C276TM (on AISI seat) Inert fluid - Halocarbon Hastelloy C276TM Inert fluid - Halocarbon Inert fluid - Halocarbon Monel 400TM Tantalum Inert fluid - Halocarbon Process flanges/adapters material and connection (wetted parts) - 9th character AISI 316 L ss (Horizontal connection) AISI 316 L ss (Horizontal connection) Hastelloy C276TM (Horizontal connection) Hastelloy C276TM (Horizontal connection) Monel 400TM (Horizontal connection) Monel 400TM (Horizontal connection) AISI 316 L ss (Vertical connection) AISI 316 L ss (Vertical connection) Hastelloy C276TM (Vertical onnection) Hastelloy C276TM (Vertical connection) Monel 400TM (Vertical connection) Monel 400TM (Vertical connection) (Note 2) NACE NACE NACE NACE (Note 2) (Note 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) NACE NACE NACE NACE NACE NACE NACE NACE 1 /4in NPT-f direct (7/16in UNF U.S. drilling) /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE 1 S H K M T A B F C D L Q P 4 5 A B D E G H Q T M S U V Bolts/Gasket (wetted parts) - 10th character AISI 316 ss VitonTM AISI 316 ss PTFE AISI 316 ss (NACE) - (MWP = 16MPa) VitonTM AISI 316 ss (NACE) - (MWP = 16MPa) PTFE th Housing material and electrical connection - 11 character Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) (Note 1) NACE NACE (Note 1) 1 /2in NPT M20 x 1.5 (CM 20) Pg 13.5 1 /2in GK Harting Han connector 1 /2in NPT M20 x 1.5 (CM 20) Pg 13.5 1 /2in GK Harting Han connector 1 /2in NPT M20 x 1.5 (CM20) Pg 13.5 1 /2in GK M20 x 1.5 (CM 20) Pg 13.5 Harting Han connector (Note 3) (general purpose only) (Note 3) (general purpose only) (general purpose only) (general purpose only) (Note 3) (general purpose only) 1 2 3 4 A B D C E H L N M P S T V U J Y K Output/Additional options - 12th character HART digital communication and 4 to 20mA (SIL 2) HART digital communication and 4 to 20mA (SIL 2) No additional options Options requested (to be ordered by "Additional ordering code") (Note 4) S 4 11 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 ADDITIONAL ORDERING INFORMATION for model 268DS Add one or more 2-digit code(s) after the basic ordering information to select all required options XX XX XX XX XX XX XX XX XX XX XX XX XX Drain/vent valve (material and position) (wetted parts) AISI 316 L ss on process axis AISI 316 L ss on flange side top AISI 316 L ss on flange side bottom Hastelloy C276TM on process axis Hastelloy C276TM on flange side top Hastelloy C276TM on flange side bottom Monel 400TM on process axis Monel 400TM on flange side top Monel 400TM on flange side bottom Electrical certification ATEX Group II Category 1 G - Intrinsic Safety EEx ia ATEX Group II Category 1/2 GD - Flameproof EEx d Factory Mutual (FM) approval (only with 1/2in NPT, M20 and Output meter (Note (Note (Note (Note (Note (Note (Note (Note (Note 5) 6) 6) 7) 8) 8) 9) 10) 10) Pg 13.5 electrical connection) ProMeter, Standard calibration ProMeter, Special calibration Analog output indicator linear 0-100% scale Analog output indicator square root 0-10 scale Analog output indicator, special graduation (to be specified for linear scale) Analog output indicator, special graduation (to be specified for square root scale) Programmable signal meter and HART configurator (CoMeter) Programmable signal meter and HART configurator (CoMeter - customer configuration) Mounting bracket (shape and material) For pipe mounting (Not suitable for AISI housing) Carbon steel For pipe mounting (Not suitable for AISI housing) AISI 316 L ss For wall mounting (Not suitable for AISI housing) Carbon steel For wall mounting (Not suitable for AISI housing) AISI 316 L ss Flat type for box AISI 316 L ss Surge Surge/Transient Protector Operating manual German Italian French Labels & tag language German Italian French Additional tag plate Laser printing of tag on stainless steel plate NACE NACE NACE NACE NACE NACE NACE NACE NACE V1 V2 V3 V4 V5 V6 V7 V8 V9 E1 E2 E6 D1 D2 D3 D4 D5 D6 D7 D8 B1 B2 B3 B4 B5 S1 M1 M2 M4 T1 T2 T4 I2 Configuration Standard - Pressure = inH2O/psi at 20 C; Temperature = deg. F Standard - Pressure = inH2O/psi at 4 C; Temperature = deg. F Standard - Pressure = inH2O/psi at 20 C; Temperature = deg.C Standard - Pressure = inH2O/psi at 4 C; Temperature = deg. C Custom Preparation procedure Oxygen service cleaning (only available with inert fill and PTFE gasket) - Pmax =12MPa for Galden or 9MPa for Halocarbon; Tmax = 60 C/140 Hydrogen service preparation Special services preparation N2 N3 N4 N5 N6 F P1 P2 P4 Certificates Inspection certificate EN 10204-3.1.B of calibration (9-point) Certificate of compliance with the order EN 10204-2.1 of instrument design C1 C6 Material traceability Certificate of compliance with the order EN 10204-2.1 of process wetted parts Inspection certificate EN 10204-3.1.B of process wetted parts H1 H3 Connector Harting Han - straight entry Harting Han - angle entry 12 (Note 11) (Note 11) U3 U4 2600T Pressure Transmitters Model 268DS, 268PS, 268VS Note 1: Suitable for oxygen service Note 2: Not available with sensor code B Note 3: Select type in additional ordering code Note 4: Not available with Electronic Housing code P, E and K Note 5: Not available with Process flanges/adapters code D, E, G, H, Q, T, M, S, U, V Note 6: Not available with Process flanges/adapters code D, E, G, H, M, S, U, V Note 7: Not available with Process flanges/adapters code A, B, G, H, Q, T, M, S, U, V Note 8: Not available with Process flanges/adapters code A, B, G, H, Q, T, U, V Note 9: Not available with Process flanges/adapters code A, B, D, E, Q, T, M, S, U, V SS/268XS_2 Note 10: Not available with Process flanges/adapters code A, B, D, E, Q, T, M, S Note 11: Not available with Electronic housing code U, S, T, V, H, M, L, N, D, C, A, B, J, Y TM Hastelloy is a Cabot Corporation trademark TM Monel is an International Nickel Co. trademark TM Viton is a Dupont de Nemour trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark Standard delivery items (can be differently specified by additional ordering code) - Adapters supplied loose - Plug on axis of horizontal connection flange; nothing for vertical connection blind flange (no drain/vent valves) - General purpose (no electrical certification) - No meter/display, no mounting bracket, no surge protection - English manual and labels - Configuration with kPa and deg. C units - No test, inspection or material traceability certificates THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'S RESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING. 13 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 BASIC ORDERING INFORMATION model 268PS Safety Gauge Pressure Transmitter Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required. BASE MODEL - 1st to 5th characters 2 6 8 P S X S X X X X X Safety Gauge Pressure Transmitter - BASE ACCURACY 0.075% SENSOR - Span limits - 6th character 0.14 and 4kPa 1.4 and 40mbar 0.27 and 16 kPa 2.7 and 160mbar 0.4 and 40kPa 4 and 400mbar 0.65 and 65kPa 6.5 and 650mbar 1.6 and 160kPa 16 and 1600mbar 6 and 600kPa 0.06 and 6bar 24 and 2400kPa 0.24 and 24bar 80 and 8000kPa 0.8 and 80bar 160 and 16000kPa 1.6 and 160bar B E F G H M P Q S 0.56 and 16inH2O 1.08 and 64inH2O 1.6 and 160inH2O 2.6 and 260inH2O 6.4 and 642inH2O 0.87 and 87psi 3.5 and 348psi 11.6 and 1160psi 23.2 and 2320psi Use code - 7th character Diaphragm material / Fill fluid (wetted parts) - 8th character AISI 316 L ss Silicone oil Hastelloy C276TM (on AISI seat) Silicone oil Hastelloy C276TM Silicone oil Monel 400TM Silicone oil Silicone oil Tantalum AISI 316 L ss Inert fluid - Galden Hastelloy C276TM (on AISI seat) Inert fluid - Galden Inert fluid - Galden Hastelloy C276TM Monel 400TM Inert fluid - Galden Inert fluid - Galden Tantalum Inert fluid - Halocarbon AISI 316 L ss Hastelloy C276TM (on AISI seat) Inert fluid - Halocarbon Hastelloy C276TM Inert fluid - Halocarbon Inert fluid - Halocarbon Monel 400TM Tantalum Inert fluid - Halocarbon Process flanges/adapters material and connection (wetted parts) - 9th character AISI 316 L ss (Horizontal connection) AISI 316 L ss (Horizontal connection) Hastelloy C276TM (Horizontal connection) Hastelloy C276TM (Horizontal connection) Monel 400TM (Horizontal connection) Monel 400TM (Horizontal connection) AISI 316 L ss (Vertical connection) AISI 316 L ss (Vertical connection) Hastelloy C276TM (Vertical onnection) Hastelloy C276TM (Vertical connection) Monel 400TM (Vertical connection) Monel 400TM (Vertical connection) (Note 2) NACE NACE NACE NACE (Note 2) (Note 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) /4in NPT-f direct (7/16in UNF U.S. drilling) /2in NPT-f through adapter (7/16in UNF U.S. 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. NACE NACE NACE NACE NACE NACE NACE NACE 1 1 NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE drilling) drilling) drilling) drilling) drilling) drilling) S H K M T A B F C D L Q P 4 5 A B D E G H Q T M S U V Bolts/Gasket (wetted parts) - 10th character AISI 316 ss VitonTM AISI 316 ss PTFE AISI 316 ss (NACE) - (MWP = 16MPa) VitonTM AISI 316 ss (NACE) - (MWP = 16MPa) PTFE (Note 1) Housing material and electrical connection - 11th character Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) (Note 1) NACE NACE (Note 1) 1 /2in NPT M20 x 1.5 (CM 20) Pg 13.5 1 /2in GK Harting Han connector 1 /2in NPT M20 x 1.5 (CM 20) Pg 13.5 1 /2in GK Harting Han connector 1 /2in NPT M20 x 1.5 (CM20) Pg 13.5 1 /2in GK M20 x 1.5 (CM 20) Pg 13.5 Harting Han connector (Note 3) (general purpose only) (Note 3) (general purpose only) (general purpose only) (general purpose only) (Note 3) (general purpose only) 1 2 3 4 A B D C E H L N M P S T V U J Y K Output/Additional options - 12th character HART digital communication and 4 to 20mA (SIL 2) HART digital communication and 4 to 20mA (SIL 2) 14 No additional options Options requested (to be ordered by "Additional ordering code") (Note 4) S 4 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 ADDITIONAL ORDERING INFORMATION for model 268PS Add one or more 2-digit code(s) after the basic ordering information to select all required options XX XX XX XX XX XX XX XX XX XX XX XX XX Drain/vent valve (material and position) (wetted parts) AISI 316 L ss on process axis AISI 316 L ss on flange side top AISI 316 L ss on flange side bottom Hastelloy C276TM on process axis Hastelloy C276TM on flange side top Hastelloy C276TM on flange side bottom Monel 400TM on process axis Monel 400TM on flange side top Monel 400TM on flange side bottom Electrical certification ATEX Group II Category 1 G - Intrinsic Safety EEx ia ATEX Group II Category 1/2 GD - Flameproof EEx d Factory Mutual (FM) approval (only with 1/2in NPT, M20 and Output meter (Note (Note (Note (Note (Note (Note (Note (Note (Note 5) 6) 6) 7) 8) 8) 9) 10) 10) Pg 13.5 electrical connection) ProMeter, Standard calibration ProMeter, Special calibration Analog output indicator linear 0-100% scale Analog output indicator, special graduation (to be specified for linear scale) Programmable signal meter and HART configurator (CoMeter) Programmable signal meter and HART configurator (CoMeter - customer configuration) Mounting bracket (shape and material) For pipe mounting (Not suitable for AISI housing) Carbon steel For pipe mounting (Not suitable for AISI housing) AISI 316 L ss For wall mounting (Not suitable for AISI housing) Carbon steel For wall mounting (Not suitable for AISI housing) AISI 316 L ss Flat type for box AISI 316 L ss Surge Surge/Transient Protector Operating manual German Italian French Labels & tag language German Italian French Additional tag plate Laser printing of tag on stainless steel plate NACE NACE NACE NACE NACE NACE NACE NACE NACE V1 V2 V3 V4 V5 V6 V7 V8 V9 E1 E5 E6 D1 D2 D3 D5 D7 D8 B1 B2 B3 B4 B5 S1 M1 M2 M4 T1 T2 T4 I2 Configuration Standard - Pressure = inH2O/psi at 20 C; Temperature = deg. F Standard - Pressure = inH2O/psi at 4 C; Temperature = deg. F Standard - Pressure = inH2O/psi at 20 C; Temperature = deg.C Standard - Pressure = inH2O/psi at 4 C; Temperature = deg. C Custom Preparation procedure Oxygen service cleaning (only available with inert fill and PTFE gasket) - Pmax =12MPa for Galden or 9MPa for Halocarbon; Tmax = 60 C/140 Hydrogen service preparation Special services preparation N2 N3 N4 N5 N6 F P1 P2 P4 Certificates Inspection certificate EN 10204-3.1.B of calibration (9-point) Certificate of compliance with the order EN 10204-2.1 of instrument design C1 C6 Material traceability Certificate of compliance with the order EN 10204-2.1 of process wetted parts Inspection certificate EN 10204-3.1.B of process wetted parts H1 H3 Connector Harting Han - straight entry Harting Han - angle entry (Note 11) (Note 11) U3 U4 15 2600T Pressure Transmitters Model 268DS, 268PS, 268VS Note 1: Suitable for oxygen service Note 2: Not available with sensor code B Note 3: Select type in additional ordering code Note 4: Not available with Electronic Housing code P, E and K Note 5: Not available with Process flanges/adapters code D, E, G, H, Q, T, M, S, U, V Note 6: Not available with Process flanges/adapters code D, E, G, H, M, S, U, V Note 7: Not available with Process flanges/adapters code A, B, G, H, Q, T, M, S, U, V Note 8: Not available with Process flanges/adapters code A, B, G, H, Q, T, U, V Note 9: Not available with Process flanges/adapters code A, B, D, E, Q, T, M, S, U, V Note 10: Not available with Process flanges/adapters code A, B, D, E, Q, T, M, S Note 11: Not available with Electronic housing code U, S, T, V, H, M, L, N, D, C, A, B, J, Y TM Hastelloy is a Cabot Corporation trademark TM Monel is an International Nickel Co. trademark TM Viton is a Dupont de Nemour trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark Standard delivery items (can be differently specified by additional ordering code) - Adapters supplied loose - Plug on axis of horizontal connection flange; nothing for vertical connection blind flange (no drain/vent valves) - General purpose (no electrical certification) - No meter/display, no mounting bracket, no surge protection - English manual and labels - Configuration with kPa and deg. C units - No test, inspection or material traceability certificates THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'S RESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING. 16 SS/268XS_2 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 BASIC ORDERING INFORMATION model 268VS Safety Absolute Pressure Transmitter Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required. BASE MODEL - 1st to 5th characters 2 6 8 V S X S X X X X X Safety Absolute Pressure Transmitter - BASE ACCURACY 0.075% SENSOR - Span limits - 6th character 0.27 and 16 kPa 2.7 and 160mbar 0.67 and 40kPa 6.7 and 400mbar 1.1 and 65kPa 11 and 650mbar 2.67 and 160kPa 26.7 and 1600mbar 10 and 600kPa 0.1 and 6bar 40 and 2400kPa 0.4 and 24bar 134 and 8000kPa 1.34 and 80bar 267 and 16000kPa 2.67 and 160bar 2 and 120mmHg 5 and 300mmHg 8 and 480mmHg 20 and 1200mmHg 1.45 and 87psi 5.8 and 348psi 19.4 and 1160psi 38.7 and 2320psi E F G H M P Q S Use code - 7th character Diaphragm material / Fill fluid (wetted parts) - 8th character AISI 316 L ss Silicone oil Hastelloy C276TM (on AISI seat) Silicone oil Hastelloy C276TM Silicone oil AISI 316 L ss Inert fluid - Galden Hastelloy C276TM (on AISI seat) Inert fluid - Galden Hastelloy C276TM Inert fluid - Galden AISI 316 L ss Inert fluid - Halocarbon Hastelloy C276TM (on AISI seat) Inert fluid - Halocarbon Hastelloy C276TM Inert fluid - Halocarbon Process flanges/adapters material and connection (wetted parts) - 9th character AISI 316 L ss (Horizontal connection) AISI 316 L ss (Horizontal connection) Hastelloy C276TM (Horizontal connection) Hastelloy C276TM (Horizontal connection) Monel 400TM (Horizontal connection) Monel 400TM (Horizontal connection) AISI 316 L ss (Vertical connection) AISI 316 L ss (Vertical connection) Hastelloy C276TM (Vertical onnection) Hastelloy C276TM (Vertical connection) Monel 400TM (Vertical connection) Monel 400TM (Vertical connection) S NACE H NACE K A NACE B NACE F L NACE Q NACE P (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) (Notes 1, 2) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16inUNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE 1 A B D E G H Q T M S U V Bolts/Gasket (wetted parts) - 10th character AISI 316 ss VitonTM AISI 316 ss PTFE AISI 316 ss (NACE) - (MWP = 16MPa) VitonTM AISI 316 ss (NACE) - (MWP = 16MPa) PTFE Housing material and electrical connection - 11th character Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) Aluminium alloy copper-free (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) (Note 1) NACE NACE (Note 1) 1 /2in NPT M20 x 1.5 (CM 20) Pg 13.5 1 /2in GK Harting Han connector 1 /2in NPT M20 x 1.5 (CM 20) Pg 13.5 1 /2in GK Harting Han connector 1 /2in NPT M20 x 1.5 (CM20) Pg 13.5 1 /2in GK M20 x 1.5 (CM 20) Pg 13.5 Harting Han connector (Note 3) (general purpose only) (Note 3) (general purpose only) (general purpose only) (general purpose only) (Note 3) (general purpose only) 1 2 3 4 A B D C E H L N M P S T V U J Y K Output/Additional options - 12th character HART digital communication and 4 to 20mA (SIL 2) HART digital communication and 4 to 20mA (SIL 2) No additional options Options requested (to be ordered by "Additional ordering code (Note 4) S 4 17 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 ADDITIONAL ORDERING INFORMATION for model 268VS Add one or more 2-digit code(s) after the basic ordering information to select all required options XX XX XX XX XX XX XX XX XX XX XX XX XX Drain/vent valve (material and position) (wetted parts) AISI 316 L ss on process axis (Note 5) AISI 316 L ss on flange side top (Note 6) AISI 316 L ss on flange side bottom (Note 6) Hastelloy C276TM on process axis (Note 7) Hastelloy C276TM on flange side top (Note 8) Hastelloy C276TM on flange side bottom (Note 8) Monel 400TM on process axis (Note 9) Monel 400TM on flange side top (Note 10) Monel 400TM on flange side bottom (Note 10) Electrical certification ATEX Group II Category 1 G - Intrinsic Safety EEx ia ATEX Group II Category 1/2 GD - Flameproof EEx d Factory Mutual (FM) approval (only with 1/2in NPT, M20 and Pg 13.5 electrical connection) Output meter ProMeter, Standard calibration ProMeter, Special calibration Analog output indicator linear 0-100% scale Analog output indicator, special graduation (to be specified for linear scale) Programmable signal meter and HART configurator (CoMeter) Programmable signal meter and HART configurator (CoMeter - customer configuration) Mounting bracket (shape and material) For pipe mounting (Not suitable for AISI housing) Carbon steel For pipe mounting (Not suitable for AISI housing) AISI 316 L ss For wall mounting (Not suitable for AISI housing) Carbon steel For wall mounting (Not suitable for AISI housing) AISI 316 L ss Flat type for box AISI 316 L ss Surge Surge/Transient Protector Operating manual German Italian French Labels & tag language German Italian French Additional tag plate Laser printing of tag on stainless steel plate NACE NACE NACE NACE NACE NACE NACE NACE NACE V1 V2 V3 V4 V5 V6 V7 V8 V9 E1 E2 E6 D1 D2 D3 D5 D7 D8 B1 B2 B3 B4 B5 S1 M1 M2 M4 T1 T2 T4 I2 Configuration Standard - Pressure = inH2O/psi at 20 C; Temperature = deg. F N2 Standard - Pressure = inH2O/psi at 4 C; Temperature = deg. F N3 Standard - Pressure = inH2O/psi at 20 C; Temperature = deg.C N4 Standard - Pressure = inH2O/psi at 4 C; Temperature = deg. C N5 Custom N6 Preparation procedure Oxygen service cleaning (only available with inert fill and PTFE gasket) - Pmax = 12MPa for Galden or 9MPa for Halocarbon; Tmax =60 C/140 F P1 Hydrogen service preparation P2 Special services preparation P4 Certificates Inspection certificate EN 10204-3.1.B of calibration (9-point) Certificate of compliance with the order EN 10204-2.1 of instrument design C1 C6 Material traceability Certificate of compliance with the order EN 10204-2.1 of process wetted parts Inspection certificate EN 10204-3.1.B of process wetted parts H1 H3 Connector Harting Han - straight entry Harting Han - angle entry 18 (Note 11) (Note 11) U3 U4 2600T Pressure Transmitters Model 268DS, 268PS, 268VS Note 1: Suitable for oxygen service Note 2: Not available with sensor code E Note 3: Select type in additional ordering code Note 4: Not available with Electronic Housing code P, E and K Note 5: Not available with Process flanges/adapters code D, E, G, H, Q, T, M, S, U, V Note 6: Not available with Process flanges/adapters code D, E, G, H, M, S, U, V Note 7: Not available with Process flanges/adapters code A, B, G, H, Q, T, M, S, U, V Note 8: Not available with Process flanges/adapters code A, B, G, H, Q, T, U, V Note 9: Not available with Process flanges/adapters code A, B, D, E, Q, T, M, S, U, V SS/268XS_2 Note 10: Not available with Process flanges/adapters code A, B, D, E, Q, T, M, S Note 11: Not available with Electronic housing code U, S, T, V, H, M, L, N, D, C, A, B, J, Y TM Hastelloy is a Cabot Corporation trademark TM Monel is an International Nickel Co. trademark TM Viton is a Dupont de Nemour trademark TM Galden is a Montefluos trademark TM Halocarbon is a Halocarbon Products Co. trademark Standard delivery items (can be differently specified by additional ordering code) - Adapters supplied loose - Plug on axis of horizontal connection flange; nothing for vertical connection blind flange (no drain/vent valves) - General purpose (no electrical certification) - No meter/display, no mounting bracket, no surge protection - English manual and labels - Configuration with kPa and deg. C units - No test, inspection or material traceability certificates THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'S RESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING. 19 2600T Pressure Transmitters Model 268DS, 268PS, 268VS SS/268XS_2 The Company's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB has Sales & Customer Support expertise in over 100 countries worldwide Printed in Italy (01.04) www.abb.com/instrumentation SS/268XS_2 (c) ABB 2004 ABB Ltd Howard Road, St. Neots Cambridgeshire, PE19 3EU UK Tel: +44(0)1480 475321 Fax: +44(0)1480 217948 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB SACE spa Business Unit Instrumentation Via Statale 113 22016 Lenno (CO) Italy Tel: +39 0344 58111 Fax: +39 0344 56278