Description
Encapsulated Through Hole Design
Isolation between Pri and Sec of 3750 Volts
Materials meet UL Class B
Applications
Feedback elements linking the output and pulse control
circuitry
Switch Mode Power Supplies: PFC, Half-bridge,
Full-bridge, Forward
Off-Line
Telecom
Part Inductance Turns +/-1% Current Range DCR ()+/-15% Recommended Frequency
Number (mH) AMPS @ 20°C Terminating Range
Resistor
CS-1050-R 5.6 50 1-10 0.60 50 ohms 20k-200kHz
CS-1100-R 22.4 100 2-20 1.3 100 ohms 20k-200kHz
CS-1200-R 89.7 200 4-40 3.3 200 ohms 20k-100kHz
1) Test Parameters: 10kHz, 0.25 Vrms
2) Dimensions in Millimeters
3) Output Voltage is 1v/A with the terminating resistor and is linear over the
specified range
4) Hipot is 3750 Volts from winding to test wire A-B
5) Materials meet UL Class B
6) Polarity Indicator Dot: (This lead is in phase with lead A of conductor A-B)
CS Series
Current Sense
Current Sense Inductors
Mechanical Diagrams
2
0.81
4.57Dia
12.70
17.15
11.74
20.32
1
wwllyy R
CS-xxx
4.77
6.35
9.53
AB
1
2
A
B
Visit us on the Web at www.cooperbussmann.com
1225 Broken Sound Pkwy. Suite F Boca Raton, FL 33487
Tel: +1-561-998-4100 Toll Free: +1-888-414-2645 Fax: +1-561-241-6640
This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Electronic
Technologies reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper
Electronic Technologies also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been
selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Electronic Technologies does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when
properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.
PM-4123 3/07
© Cooper Electronic
Technologies 2007
xxx = Inductance value
wwllyy = Date code R = Revision level
RoHS
2002/95/EC