CT (ACT)
2ds_61205_en_ct: 010113J
2. Specifications
Notes:
*1.This value can change due to the switching fr equency , environmental cond itions, and desired reliability level, therefor e it is recommended to check this with the actual load.
*2.The upper operation ambie nt temperature limit is the maximum temperature that can satisfy the coil temperature rise value. R efer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F).
*3.Depends on connection cond itions. Also, this does not guarantee repeated switching. We recommend that you conf irm operation under actual conditions.
If the relay is used continuously f or long periods of time with coils on both side s in an ene rgized co ndition, breakdo wn might occur due to abn ormal heating depending on
the carrying condition. Therefore, please inquire when using with a circuit that causes an energized condition on both sides simultaneously.
REFERENCE DATA
Characteristics Item Specifications
Contact Arrangement 1 Form C 2, 1 Form C
Contact resistance (Initial) N.O.: Typ 7m, N.C.: Typ 10m (By voltage drop 6V DC 1A)
Contact material Ag alloy (Cadmium free)
Rating
Nominal switching capacity (resistive load) N.O.: 20 A 14V DC, N.C.: 10 A 14V DC
Max. carrying current (14V DC)*3N.O.: 25 A for 1 hou r, 35 A for 2 minutes at 20C 68F
20 A for 1 hour, 30 A for 2 minutes at 85C 185F
Nominal operating power 800 mW
Min. switching capacity (resistive load)*11 A 14V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100 M (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
Breakdown voltage
(Initial) Between open contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contacts and coil 500 Vrms for 1 min. (Detection current: 10mA)
Operate time (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)
Release time (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)
Mechanical
characteristics
Shock resistance Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s)
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
Vibration resistance Functional 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5 G} (Dete ction time: 10s)
Destructive 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G},
T i me of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected life
Mechanical Min. 107 (at 120 cpm)
Electrical
<Resistive load>
Min. 105 (at nominal switching capacity, operating frequency: 1s ON, 9s OFF)
<Motor load>
N.O. side: Min. 2 105 (at Inrush 25A, Steady 5A 14 V DC),
Min. 105 (at 25A 14 V DC motor lock condition)
N.C. side: Min. 2 105 (at brake current 20A 14 V DC) (operating frequen cy: 0.5s ON, 9.5s
OFF)
Conditions Conditions for operation, transport and storage*2Ambient temperature: –40C to +85C –40F to +185F,
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 6 cpm (at nominal switching capacity )
Mass Twin type: approx. 8 g .28 oz, 1 Fo rm C type: approx. 4 g .14 oz