Indicator (Cylindrical 22/25-dia.) M22 CSM_M22_DS_E_3_1 Round Indicator Series with 22 dia. and 25 dia. (when using a ring) * Same type as the A22-series Pushbutton Switches. * Use 25-dia. ring to install in 25-dia. panel cutouts. * IP65 Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions for the A22. List of Models Appearance Flat Model Round M22-F Projection Square M22-C Model Number Structure Model Number Legend......Shipped as a set which includes the Display, Lamp, and Socket Unit. For information on combinations, refer to Ordering Information. M22 (1) (2) (3) - F G - 24A (1) Display Shape Code F C Description Round/Flat Square/Projection (2) Illumination Color (3) Light Source Without Voltage Reduction Unit Code Description R G Y W A Red Green Yellow White Blue Code 6A 12A 24A 5 12 24 Type LED Incandescent lamp Operating voltage 6 VAC/VDC 12 VAC/VDC 24 VAC/VDC 5 VAC/VDC 12 VAC/VDC 24 VAC/VDC With Voltage Reduction Unit Code T1 T2 Type LED Operating voltage 100 VAC 200 VAC * LED incorporates the 24-VAC/VDC type. 1 M22 Ordering Information Completely Assembled .... Shipped as a set which includes the Display, Lamp, and Socket Unit. Indicator Appearance Round/Flat without Voltage Reduction Unit M22-F Round/Flat with Voltage Reduction Unit M22-F Square/Projection without Voltage Reduction Unit M22-C Square/Projection with Voltage Reduction Unit M22-C Lighting LED Operating voltage Set 6 VAC/VDC M22-F@-6A 12 VAC/VDC M22-F@-12A 24 VAC/VDC M22-F@-24A 100 VAC M22-F@-T1 200 VAC M22-F@-T2 6 VAC/VDC M22-C@-6A 12 VAC/VDC M22-C@-12A 24 VAC/VDC M22-C@-24A 100 VAC M22-C@-T1 200 VAC M22-C@-T2 LED LED Illumination color R (red) Y (yellow) G (green) W (white) A (blue) LED Note: Insert a symbol indicating the color of the Operation Unit in the box in the model number above. Individual models: Refer to pages 3 to 4. Specifications: Refer to page 5. Dimensions: Refer to page 6. (The Display, Lamp, and Socket Unit can be ordered separately.) Accessories: Refer to the A22. 2 M22 Ordering Information Subassembled .......... The Display, Lamp, or Socket Unit can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts. * Ordering: Specify models on the following page. Display Lamp Lamp Incandescent lamp LED Socket Unit Without Voltage Reduction Unit Ordering set combinations: Refer to page 2. LED Socket Unit With Voltage Reduction Unit Specifications: Refer to page 5. Dimensions: Refer to page 6. Accessories: Refer to the A22. 3 M22 Ordering Information Subassembled .......... The Display, Lamp, or Socket Unit can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts. Display Sealing Appearance Round (Flat) Square (Projection) IP65 Color of Display Red Green Yellow White Blue Red Green Yellow White M22-FR M22-FG M22-FY M22-FW M22-FA M22-CR M22-CG M22-CY M22-CW Model Blue M22-CA Lamp LED Operating voltage Appearance AC/DC LED light Red Green Yellow * Blue AC and DC Red Green Yellow * Blue 6V 12 V Model -- -- -- -- A22-12AR A22-12AG A22-12AY A22-12AA A22-6AR A22-6AG A22-6AY A22-6AA -- -- -- -- 24 V -- -- -- -- A22-24AR A22-24AG A22-24AY A22-24AA Note: For voltage-reduction lighting, use the A22-24A@. Only 24-V LED lamps can be used. * Used when the Display color is yellow or white. Incandescent Appearance Operating voltage 5 VAC/VDC A22-5 12 VAC/VDC A22-12 24 VAC/VDC A22-24 Socket Unit Appearance Item Classification Without Voltage Reduction Unit Model M22-00 With Voltage Reduction Unit (110 VAC) M22-00-T1 With Voltage Reduction Unit (220 VAC) M22-00-T2 Note: For voltage-reduction lighting, use the A22-24A@. Only 24-V LED lamps can be used. Accessories, Replacements, and Tools The M22 uses the same accessories as the A22. Refer to the relevant information in the corresponding section for the A22. 4 M22 Specifications Ratings Characteristics LED Lamp Rated voltage 6 VAC/VDC 12 VAC/VDC 24 VAC/VDC Rated current 8 mA Operating voltage 6 VAC/VDC 5% 12 VAC/VDC 5% 24 VAC/VDC 5% Incandescent Lamp Rated voltage 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC Rated current 200 mA 80 mA 40 mA Operating voltage 5V 12 V 24 V Rated current 110 VAC 8 mA 220 VAC -20C to 55C 35% to 85%RH -40C to 70C IP65 Class II 175 3 (IEC60947-5-1) Approved Standard Ratings UL, cUL (File No. E41515) Input voltage: 120 V max. 2.6 W max. (A22-TN) 110 VAC (A22-T1) 200 VAC (A22-T2) Voltage-reduction Lighting Rated voltage Ambient operating temperature Ambient operating humidity Ambient storage temperature Degree of protection Electric shock protection class PTI (tracking characteristic) Degree of contamination Operating Applicable lamp voltage (BA9S/Base: 13) 100 VAC (95 to 115 V) LED lamp (A22-24@) 200 VAC (190 to 230 V) Note: Only Lamp Sockets are recognized by UL. CCC (GB14048.5) 24 VAC/VDC max. (Without Voltage Reduction Unit) 100 VAC (With Voltage Reduction Unit: M22-@@-T1) 200 VAC (With Voltage Reduction Unit: M22-@@-T2) Nomenclature Model Structure Display Available Colors Red, green yellow, white, blue Lock Ring Lamp Light Source LED lamp Incandescent lamp Socket Unit Lighting Method Lighted (without Voltage Reduction Unit) Lighted (with Voltage Reduction Unit) 5 M22 Dimensions (Unit: mm) Indicators Round M22-F Square M22-C 29.8 x 29.8 25.6 x 25.6 34 29.7 dia. 34 1.8 1.8 0.5 0.5 5.9 16 5.9 54.7 Terminal Arrangement (Bottom View) With/Without Voltage Reduction Unit 18 54.7 Terminal Connection Type Without Voltage Reduction Unit X1 With Voltage Reduction Unit X1 (+) 22 Terminal Connection X X2 X X2 (-) M3.5 screw Lamp Socket Note: The figure shows an example of the terminal arrangement when the Socket Unit is removed. Panel Cutouts 22.3 +0.4 dia. 0 25 +0.5 0 dia. Lock Ring is provided as a standard item. * When applying coating such as paint to the panel, the dimensions should be those after the application of coating. * Recommended panel thickness: 1 to 5 mm. * Use an A22Z-R25 Ring when mounting to a panel with 25-mm holes. Accessories Refer to the relevant information in the corresponding section for the A22. Safety Precautions Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions for the A22. 6 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.12 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: M22R-EG-12A M22R-EA-12A M22R-EY-12A M22R-EW-12A M22R-EA-T1 M22R-EY-T1 M22R-ER-12A M22REG-T1