LITE-ON TECHNOLOGY CORP.
Property of Lite-on Only
ISOLATION CHARACTERISTICS
PARAMETER SYMBOL MIN. TYP. MAX. UNIT CONDITIONS
6 Isolation Resistance ( Input-output ) RI-O — 1012 —
Ta=25℃, RH<45%,
VI-O=500V DC
6 Capacitance ( Input-output ) CI-O — 0.6 — pF f=1MHz
** All typical at TA = 25℃
Notes,
1. AC For 1 Minute, R.H. = 40 ~ 60%
Isolation voltage shall be measured using the following method.
(1) Short between anode and cathode on the primary side and between collector and
emitter on the secondary side.
(2) The isolation voltage tester with zero-cross circuit shall be used.
(3) The waveform of applied voltage shall be a sine wave.
2. For 10 Seconds
3. Current Transfer Ratio (CTR) is defined as the ration of output collector current, Io,
to the forward LED input current, IF, times 100%.
4. Add a 0.1uF bypass capacitor connected between pin5 and pin8 is recommended.
5. Common transient immunity in logic high level is the maximum tolerance (positive)
dVCM/dt on the leading edge of the common mode pulse signal, VCM, to assure that the
output will remain in a logic high state (i.e., Vo>2.0V). Common mode transient
immunity in a logic low level is the m aximum tolerance (negative) dVCM/dt on the teailing
edge of the common mode pulse signal, VCM, to assure that the output will remain in a
logic low state (i.e., Vo<0.8V).
6. Device considered a two terminal device. Pins 1, 2, 3 and 4 shorted together and Pins 5, 6,
7 and 8 shorted together.
7. The 4.1 kΩ load represents 1 LSTTL unit load of 0.36mAand 6.1 kΩ pull up resistor.
8. The 1.9 kΩ load represents 1 TTL unit load of 1.6mAand 5.6 kΩ pull up resistor.
Part No. : 6N135 / 6N136 Series (Preliminary Date Sheet) Page : 9 of 10
BNS-OD-C131/A4