2.5
2.0
1.5
1.0
0.5
0.0
Capacity to 2 Volts / Ah
0.01 0.1 1 10 100 1000
Current / mA
Available Capacity
1
2
34
5
1:
2:
3:
4:
5:
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
Operating Voltage
Temperature / °C
Voltage / V
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
−50 −35 −20 −5 10 25 40 55 70 85 100
1:
2:
3:
4:
5:
20 mA
6 mA
2 mA
0.2 mA
0.02 mA
1
2
3
4
5
Typical Discharge Curves at +25 °C
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Voltage / V
0.1 1 10 102103104105
Time / h
1 2 3 4 5 6 7
1:
2:
3:
4:
5:
6:
7:
180 Ω
560 Ω
1.8 kΩ
5.6 kΩ
18 kΩ
56 kΩ
180 kΩ
~20 mA
~6 mA
~2 mA
~0.6 mA
~0.2 mA
~0.06 mA
~0.02 mA
1.5 Ah
2.1 Ah
2.4 Ah
2.4 Ah
2.3 Ah
2.1 Ah
1.9 Ah
+
4545
Ø 0.8
Ø 0.8
50.5
−1.5
1
−0.1
1
−0.1
3.17
0.15 thick
0.2 thick0.2 thick
Ø 4.2−0.3
+0.2
0.7±0.3
7±0.5
3.5
3.5
10.16
4+0,5
4+0,5
Ø 14.7–1.2
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC13Eng
8
LTC Batteries
Performance Data
(Typical values for batteries stored at +25 °C for one year)
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
SL-360 Size: AA
System Lithium Thionyl Chloride
Nominal voltage 3.6 V
Nominal capacity 2.4 Ah
Nominal current 2 mA
Max. continuous discharge current 20 mA
Anode surface area 14 cm2
Lithium content 0.65 g
Weight 18 g
Volume 8 cm3
Temperature range −55 °C ... +85 °C
Available Terminations Catalogue No.
SL-360/S Standard 11 1 03601 00
SL-360/T Tags 11 1 03602 00
SL-360/P Pins 11 1 03603 00
SL-360/PR Pins radial 11 1 03606 00
SL-360/PT Polarized tags 11 1 03608 00
SL-360/S SL-360/T
SL-360/P
SL-360/PTSL-360/PR
Standard use and stand-by