HD160C Data Sheet Heavy-Duty Digital Multimeter Rugged autoranging meter with true-rms Key features: Highest voltage capability, measuring to 1500 Vdc and 1000 Vac CAT IV 1000 V rated Special sealing for environment and water resistance. IP67 rated Constructed with drop-resistant housing and PCB mounting Measures 1500 VDC CAT IV 1000 V IP67 Rated Temperature, Frequency & Capacitance Measures capacitance, temperature and frequency Magne-GripTM holster with magnetic hanging strap Superior 10,000 count resolution with bar graph Magne-GripTM holster, frees both hands for work No hassle warranty Includes high voltage test leads with threaded alligator clips Temperature measurement built-in Frequency and capacitance No waiting. Digi-GloTM bright backlight No shipping charges. The HD160C is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. The meter is made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistance to at least eight feet. Model HD160C has an extended voltage measurement capability of 1500 V dc and 1000 V ac, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive "No Hassle" warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. Amprobe(R) Test Tools HD160C N10140 www.Amprobe.com Data Sheet HD160C Technical Specifications General Specifications Display Polarity Indication Input overload indication 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph. Automatic OL, -OL. Low Battery Indication Display Update Rate Oper. Temp. Storage Temp. Altitude Temperature coefficient Fuse Power Auto Power-Down Battery Life (typical) B; less than 50 hours battery life remain, accuracy is no longer guaranteed Dimensions, without holster (H x W x D) Weight (incl. battery) Accessories Case material Safety EMC 2/sec, nominal; 20/sec for bargraph. 0 C to +50 C @ 0 to 75 % R.H. -20 C to 60 C @ 0 to 80 % RH, battery removed 2000 meters - indoor use 0.1 x (spec. accuracy)/C (0 C to 18 C and 28 C to 50 C) F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA - Amprobe p/n FP700 Standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 Meter powers down after approximately 30 minutes of inactivity. Not in Min/Max function. 150 hours, alkaline. Backlight usage consumes extra power and will decrease battery life significantly. Backlight auto-off after approx. 60 seconds. 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in) 642 g (22 oz) Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Temperature Adaptor (TA1A) and User Manual. Reinforced, high-impact, fire retardant thermoplastic Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67 Meets EN 61326-1 Electrical Specifications (Accuracy at 23 C 5 C, <75 % RH, guaranteed for one year.) Function DC Volts Ranges Resolution Accuracy Input Impedance CMRR NMRR OL Protection Transient protection AC Volts True rms Ranges Resolution Accuracy Input Impedance Conversion type Crest factor OL Protection Transient protection Amprobe(R) Test Tools Range Accuracy 1000 mV, 10 V, 100 V, 1500 V 0.1 mV in 1000 mV range (0.1 % rdg + 5 dgt) 10 M >120 dB up to 1500 V dc >60 dB at 50 or 60 Hz 1500 V dc or 1000 V ac rms. 12 kV impulse (1.2 S/50 S) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V/1500V dc product. This product should not be used in installations where transients exceed 12 kV. 1000 mV, 10 V, 100 V, 1000 V 0.1 mV in 1000 mV range 1000 mV (45 Hz to 400 Hz) (1.2 % rdg + 10 dgt) 10 V, 100 V (45 Hz to 500 Hz) (1.2 % rdg + 10 dgt) 10 V, 100 V (500 Hz to 2 kHz) (2.0 % rdg + 10 dgt) 1000 V (45 Hz to 1 kHz) (2.0 % rdg + 10 dgt) 10 M True rms, ac coupled 5 % to 100 % of range 3 1500 V dc or 1000 V ac rms 12 kV impulse (1.2 S/50 S) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV Data Sheet HD160C Technical Specifications (continued) Function DC Current Ranges Resolution Accuracy Input protection Burden voltage OL Protection AC Current True rms Ranges Resolution Accuracy (45 Hz to 1kHz) Voltage burden Conversion type Crest factor OL protection Resistance Ranges Resolution Accuracy Overload protection, all ranges Continuity Test Audible indication Response time Overload protection Capacitance Ranges Resolution Accuracy Test voltage Test Frequency Overload protection Temperature Ranges Resolution Accuracy Overload protection Range Accuracy 100 A, 1000 A, 10mA, 100mA, 400mA, 2A (Auto/Manual ranging) 0.01A in 100 A range 100 A range (0.5% rdg + 10 dgts) 1000 A to 400 mA ranges (0.5% rdg + 5 dgts) 2 A range (1.5% rdg + 10 dgts) 2 A/1500 V fast blow ceramic fuse 8x65 mm on A input , FP700 A range of 1 mV/1 A, mA range of 10 mV/1 mA, 2A range of 500 mV/1A, 500 mV max. (2 V max. on 1000 A, 100 mA, 400 mA, 2 A ranges) A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) 100 A, 1000 A, 10 mA, 100 mA, 400 mA, 2 A 0.01 A in 100 A range 100 A to 100 mA 400 mA 2A see DC Current True rms ac coupled 10 to 100% of range 3 see DC Current (1.5 % + 10 dgts) (2.0 % + 10 dgts) (2.5 % + 20 dgts) 1000 , 10 k, 100 k, 1000 k, 10 M, 40 M 0.1 in 1000 range 1000 to 1000 k ranges (0.5 % rdg + 8 dgts) 10 M range (1.0 % rdg + 10 dgts) 40 M range (2.0 % rdg + 10 dgts) 1500 V dc or 1000 V ac rms Less than 40 100 ms 1500 V dc or 1000 V ac rms 40 F, 400 F, 4 F, 40 F, 400 F (3999 counts) (Auto/Manual ranging) 0.01 F 40 F, 400 F ranges (3.0% rdg +10 dgts) 400 F to 40 F ranges (3.0% rdg +5 dgts) <1V 1.3 Hz on 40 F to 40 F ranges; 0.7 Hz on 400 F range 1500 V dc or 1000 V ac rms -20 C ~ 1300 C (-4 F ~ 2372 F) 1 C, 1 F -20 C ~ 10 C 10 C ~ 200 C 200 C ~ 1300 C -4 F ~ 50 F 50 F ~ 400 F 400 F ~2372 F 1500 V dc or 1000 V ac rms 3999 counts (2.0% rdg + 4 C) (1.0% rdg + 3 C) (2.0% rdg + 2 C) (2.0% rdg + 8 F) (1.0% rdg + 6 F) (2.0% rdg + 4 F) (continued on next page) www.Amprobe.com Data Sheet HD160C Technical Specifications (continued) Function Range Frequency Ranges Resolution Accuracy Sensitivity Minimum input range Minimum pulse width Duty cycle limits Overload protection Accuracy 100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz 0.01 Hz on 100 Hz range (0.1% rdg + 5 dgts) 3 Hz to 1 MHz >2.5 V ac rms 1MHz to 10MHz >2.5 V ac rms, <5 V ac rms 100 Hz range >3 Hz; 1000 Hz range >30 Hz > 25 ns > 30 % and < 70 % 1500 V dc or 1000 V ac rms Included Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Temperature Adaptor (TA1A) and User Manual. Optional Accessories TL1500 CT235A CT237A CT238A VC221B DC205C DC207C Cat IV 1000 V Test Leads with Alligator Clips 1000 A ac/dc Clamp 200 A ac/dc Current Clamp 20 A ac/dc Current Clamp Padded Vinyl Case. Fits meter & holster. Deluxe Hard-Shell Carry Case Large Deluxe Hard-Shell Carry Case with extra space for accessories HV231-10A High Voltage Probe FP700 Replacement Fuse, 2 A/1500 V, pack of two TA-1A K-type thermocouple, temperature adapter Amprobe(R) Test Tools website: www.Amprobe.com email: info@amprobe.com 6920 Seaway Blvd. Everett, WA 98203 tel: 877-AMPROBE Amprobe(R) Test Tools Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands (c)2007 Amprobe Test Tools. All rights reserved. 3/2007 PN: 1646298 Rev C Amprobe(R) Test Tools www.Amprobe.com