1
2017.2
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
FH64MA Series
Features
1. Super low profile, top contact
This top contact connector has a very thin structure with
an overall connector height of 0.5mm. (Fig.1)
2. Space-saving design
A thorough space-saving design on a 0.25mm pitch,
3.15mm depth (Locked status of actuator) produces a
thorough space-saving function. (Fig.1)
3. Smooth FPC insertion
Mating guide on the connector allows for smooth FPC
insertion in spite of the super low profile. (Fig.2)
4. High FPC retention force
The notches on both sides of FPC are held by metal
tabs, generating a high FPC retention force in spite of
the small size. (Fig.3)
5. Easy-to-manufacture FPC in spite of
the narrow pitch
In spite of the narrow pitch of P=0.25mm, similar pull-out
deviation tolerance of P=0.3mm creates the narrow pitch
without increasing the cost. (Fig.4)
6. Detects unmated FPC by means of the
proprietary mechanism.
Correct FPC insertion can be checked with FPC pattern
and mis-insertion can be detected. (Fig.5)
7. Halogen free
*AS defined by IEC 61249-2-21.
Br : 900ppm max, Cl : 900ppm max,
Br+Cl : 1,500ppm max
A thoroughly space-saving design with a super
low profile, a narrow pitch and a narrow depth
Fig.1
Smooth FPC insertion
0.25× (number of pos.-1)+2.2mm
High FPC retention force
General tolerance of FPC
Fig.2
Fig.3
Fig.4
3.15mm
0.5mm
FPC mis-mating detected
Fig.5
Pitch Pull-out
deviation X
FPC
cost
0.3mm ±0.07mm
0.25mm ±0.07mm
0.2mm ±0.05mm
*The FPC cost is an example image.
Pull-out deviation ±Xmm
Metallockingarms
preventsFPCtofall-off!!
Matingguidessurelyalign
FPCinspiteofinsertionfrom
theobliqueupperdirection!
Mating guide
In cases where the application will demand a high level of reliability, such as automotive,
please contact a company representative for further information.
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
2
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
Product Specifications
Rating
Current rating
0.2A
Operating Temperature Range
-55 to +85°C (Note 1)
Storage Temperature Range
-10 to +50°C (Note 2)
Voltage rating
AC/DC
30Vrms
Operating Humidity Range
Relative humidity 90% RH
or less (no condensation)
Storage Humidity Range
Relative humidity 90% RH
or less (no condensation)
Recommended
FPC SPC t=0.12±0.02 Gold plated
Items Specifications Conditions
1. Insulation
Resistance 50Mø min 100V DC
2.
Withstanding
Voltage
No flashover or insulation breakdown 90Vrms AC/1min
3. Contact
Resistance
200mø max
*Including FPC conductor resistance 1mA AC
4. Mechanical
Operation
Contact resistance : 200mø max
No damages, cracks and looseness of parts 10 times insertions and extractions.
5. Vibration
Resistance
Contact resistance : 200mø max
No damages, cracks and looseness of parts
Frequency : 10 to 55Hz, half amplitude : 0.75mm,
for 10 cycles in 3 axial directions.
6. Shock
Resistance
No electrical discontinuity of 1µs or longer
Contact resistance : 200mø max
No damages, cracks and looseness of parts
Acceleration : 981m/s2, duration 6ms, half-sine wave,
at 3 times in 3 axial directions
7. M oistur e
Resistance in
steady state
Contact resistance : 200mø max
Insulation resistance : 50Mø min
No damages, cracks and looseness of parts
96 hours at 40ç and humidity of 90 to 95%
8.
Temperature
Cycles
Contact resistance : 200mø max
Insulation resistance : 50Mø min
No damages, cracks and looseness of parts
Temperature : -55+15 to +35+85+15 to +35ç
Time : 30 2 to 3 30 2 to 3minutes
5 cycles with above conditions
9.
Resistance to
Soldering Heat
No deformation of case or excessive
looseness of the terminals
Reflow : See recommended temperature profile (page 6)
Manual soldering : 3510°C, 5seconds
Note 1 : Including temperature rise caused by current fl ow.
Note 2 : The term “storage” refers to the long-term storage condition of unused products before PCB mounting.
For no-electrifi cation state after PCB mounting, the operating temperature and humidity are applied.
Materials / Finish
Parts Material Finish/Color UL Regulation
Insulator LCP Beige UL94V-0
PA Black
Contact Phosphor bronze Nickel barrier gold plated
Metal fitting Phosphor bronze Pure tin reflow plated
Product Number Structure
Refer to the chart below when determining the product specifications from the product number.
Please select from the product numbers listed in this catalog when placing orders.
Terminal Type
SHWSMT horizontal staggered mounting type
Specifications
None : Regular(5000 pcs/reel)
(99) : 500 pcs/reel
Series Name : FH
Series No. : 64MA
No. of Contacts : 11
Contact Pitch : 0.25mm
FH 64MA 11S 0.25 SHW (99)
❹❺
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
3
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
Connector Dimensions
Units : mm
Part No. HRS No. No. of Contacts A B C D E
FH64MA-7S-0.25SHW(**) 580-4610-0 ** 7 3.7 2.5 1.5 1 3.23
FH64MA-9S-0.25SHW(**) Under planning (Note 1) 9 4.2 3 2 1.5 3.73
FH64MA-11S-0.25SHW(**) 580-4612-0 ** 11 4.7 3.5 2.5 2 4.23
FH64MA-13S-0.25SHW(**) Under planning (Note 1) 13 5.2 4 3 2.5 4.73
FH64MA-15S-0.25SHW(**) 580-4608-0 ** 15 5.7 4.5 3.5 3 5.23
FH64MA-17S-0.25SHW(**) Under planning (Note 1) 17 6.2 5 4 3.5 5.73
FH64MA-19S-0.25SHW(**) Under developing (Note 1) 19 6.7 5.5 4.5 4 6.23
FH64MA-21S-0.25SHW(**) Under planning (Note 1) 21 7.2 6 5 4.5 6.73
Note 1 : Contact positions without HRS No. are currently under planning and developing.
Please contact hirose for detailed information about product variation.
7
(E)
1.455±0.1(Vacuum pick up area)
(0.12)
(0.1)
(0.1)
D±0.15
C±0.15
A±0.15
B±0.15
(FPC : t=0.12)
(0.07)
0.3±0.1
0.14±0.15
(3.15 : Actuator close)
Contact
point
Contact
point
a
-
a
Contact No.1
Contact No.2
Lot No.
Polarization mark
HRS markCavity No.
No. of contacts
a
2.67±0.1
2.92±0.1
a
0.5±0.1
0.5±0.1
(0.25)
(1.2)
0.5±0.05
0.33±0.1 2.15±0.15
(1.165)
(1)
(0.45)
(90˚)
(0.18)
Note
1 : The dimension in parentheses are for reference.
2 : Lead co-planarity including reinforced chucking metals shall be 0.1 max.
3 : To be delivered with tape and reel packages.
See the packaging specifications for details.
4 : Note that preventive hole for sink mark or slit could be added for improvement.
5 : The quality remains good, even with the dark spots, which could occasionally occur on molded plastic.
6 : This product satisfies halogen free requirements defined as 900ppm maximum chlorine,
900ppm maximum bromine, and 1500ppm maximum total of chlorine and bromine.
7 Shows hook part of the chucking metal.
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
4
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
󱽧Recommended PCB Mounting Pattern
󱽧Recommended Stencil Pattern
Units : mm
Part No. HRS No. No. of Contacts B C D
FH64MA-7S-0.25SHW(**) 580-4610-0 ** 7 2.5 1.5 1
FH64MA-9S-0.25SHW(**) Under planning (Note 1) 9 3 2 1.5
FH64MA-11S-0.25SHW(**) 580-4612-0 ** 11 3.5 2.5 2
FH64MA-13S-0.25SHW(**) Under planning (Note 1) 13 4 3 2.5
FH64MA-15S-0.25SHW(**) 580-4608-0 ** 15 4.5 3.5 3
FH64MA-17S-0.25SHW(**) Under planning (Note 1) 17 5 4 3.5
FH64MA-19S-0.25SHW(**) Under developing (Note 1) 19 5.5 4.5 4
FH64MA-21S-0.25SHW(**) Under planning (Note 1) 21 6 5 4.5
Note 1 : Contact positions without HRS No. are currently under planning and developing.
Please contact hirose for detailed information about product variation.
Connector image
X
0.5
0.5
D
0.53±0.02
(0.25)
(0.05)
((n+1)/2)×
0.02 X
0.02 X
((n-1)/2)×
0.02 X
2.05±0.02 0.55±0.02
0.55±0.022.05±0.02
C±0.02
0.27±0.02
0.25±0.02
B
Contact No.1
Contact No.2
0.25±0.02
((n+1)/2)×
0.02 Y
0.02 Y
((n-1)/2)×
0.02 Y
(0.25)
2.36±0.01
(0.16)
0.44±0.01
B
C±0.02
0.5
0.23±0.01
0.25±0.01
D
0.5
0.44±0.01
0.41±0.01 2.36±0.01
0.23±0.01
(Land pattern image)
Note 8 : 'n' shows the number of contacts.
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
5
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
󱽧Recommended FPC Dimensions
󱽧FPC Configuration (Reference example)
9
9
9
9
11
10 H
1.115±0.1
0.51±0.1
0.25±0.02
0.1±0.02
F±0.05
0.24±0.03
2.63±0.3 (Stiffener)
0.97±0.05
1.63±0.3 (Exposed conductor)
0.58±0.05
(0.07)
0.85±0.07
0.25
0.07±0.02
0.07±0.02
0.24±0.03
0.1±0.02
0.13±0.1
0.43±0.1
1.27±0.1
1.17±0.1
0.61±0.1
0.85±0.07
C±0.02
G±0.05
F±0.05
0.12±0.02
0.1±0.02
0.1±0.02
0.1±0.02
D
0.345±0.02
R0.15±0.1
(R0.1)
R0.1±0.1
R0.1±0.1
R0.1±0.1
R0.1±0.1
(R0.05)
Z
12
12
Contact No.1
Contact No.2
((n+1)/2)×
0.02 Z
((n-1)/2)×
0.02 Z
Units : mm
Part No. HRS No. No. of Contacts C D F G
FH64MA-7S-0.25SHW(**) 580-4610-0 ** 7 1.5 1 3.2 2.18
FH64MA-9S-0.25SHW(**) Under planning (Note 1) 9 2 1.5 3.7 2.68
FH64MA-11S-0.25SHW(**) 580-4612-0 ** 11 2.5 2 4.2 3.18
FH64MA-13S-0.25SHW(**) Under planning (Note 1) 13 3 2.5 4.7 3.68
FH64MA-15S-0.25SHW(**) 580-4608-0 ** 15 3.5 3 5.2 4.18
FH64MA-17S-0.25SHW(**) Under planning (Note 1) 17 4 3.5 5.7 4.68
FH64MA-19S-0.25SHW(**) Under developing (Note 1) 19 4.5 4 6.2 5.18
FH64MA-21S-0.25SHW(**) Under planning (Note 1) 21 5 4.5 6.7 5.68
Note 1 : Contact positions without HRS No. are currently under planning and developing.
Please contact hirose for detailed information about product variation.
Note
9 Shows recommended dimensions when lead for plating is required.
10 Dimension H must be 0.5mm minimum.
11 Indicated tolerance is applicable to the exposed conductor.
12 Both end sides of contact pad on FPC cannot be used for signal transmission.
MATERIAL NAME
MATERIAL
THICKNESS (µm)
Covering film layer
Polyimide 1mil 25
Cover adhesive 25
Surface treatment
1µm to 6µm nickel underplated
0.2µm gold plated
(4)
Copper foil Cu 1/2oz 18
Base adhesive Heat-hardened adhesive
No adhesion
material
Base film Polyimide 1mil 25
Reinforcement
material adhesive Heat-hardened adhesive 30
Stiffener Polyimide 2mil 50
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
6
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
50
100
150
245
200
120±5 sec.
20 to 40
sec.
150
220
60 to 90 sec.
0
Time sec.
Soldering time
Peak temperature
Preheating time
MAX250
180
Start
25
Temperature (℃
Directionofunreeling
(MReelouterwidth)
(LReelinnerwidth)
(Ø380)
(Ø80)
(Ø13)
Directionofunreeling
Topcovertape
Embossedcarriertape
160mmMIN
400mmMIN(Leader)
100mmMIN
(emptycomponents)
(Trailer,emptycomponents)
󱽧Packaging Specifications
Direction of unreeling
K±0.1
(1.35)
(0.3)
Ø1.5
0
0.1
C
L
8±0.1
(2)
4±0.1
J+0.2
_0.1
1.75±0.1
Embossed Carrier Tape Dimensions
Reel Dimensions Leader, Trailer Dimensions
Units : mm
Part No. HRS No. No. of Contacts J K L M
FH64MA-7S-0.25SHW(**) 580-4610-0 ** 7 16 7.5 17.4 21.4
FH64MA-9S-0.25SHW(**) Under planning (Note 1) 9 16 7.5 17.4 21.4
FH64MA-11S-0.25SHW(**) 580-4612-0 ** 11 16 7.5 17.4 21.4
FH64MA-13S-0.25SHW(**) Under planning (Note 1) 13 16 7.5 17.4 21.4
FH64MA-15S-0.25SHW(**) 580-4608-0 ** 15 16 7.5 17.4 21.4
FH64MA-17S-0.25SHW(**) Under planning (Note 1) 17 16 7.5 17.4 21.4
FH64MA-19S-0.25SHW(**) Under developing (Note 1) 19 16 7.5 17.4 21.4
FH64MA-21S-0.25SHW(**) Under planning (Note 1) 21 24 11.5 25.4 29.4
Note 1 : Contact positions without HRS No. are currently under planning and developing.
Please contact hirose for detailed information about product variation.
󱽧Temperature Profile
Applicable Conditions
Reflow method : IR/Hot air
Reflow environment : Room air
Solder : Paste type Sn/3.0Ag/0.5Cu
(M705-GRN360-K2-V made by Senju
Metal Industry Co.)
Test PCB : PCB material and size
Glass epoxy 32.85×15.7×1mm
Land size, per recommended on page 4.
Metal mask : Thickness and opening size
Per recommended on page 4.
This temperature profile is based on the above conditions.
It may vastly depending on solder paste type, manufacturer,
PCB size and mounting materials. Please use only after
checking the mounting conditions.
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
7
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
[Operation method]
PCB
Actuator [Closed]
―Incorrect operation―
󱽧Operation Methods of Connectors and Precautions
1. Initially delivered state
The actuator is delivered in the open state, It does not need to operated before inserting FPC.
[Caution]
Do not close the actuator while FPC is not inserted. If the actuator is closed without the FPC inserted, the
FPC insertion force could increase due to the narrower contact gap.
Do not operate the connector while it is not mounted on the board.
2. How to insert FPC
Insert FPC to the end placed horizontal to the board surface. (Example 1)
[Caution]
Do not insert FPC while the actuator is closed. (Example 2)
When FPC is inserted, do not move it in vertical, lateral or diagonal directions.
3. Check the inserted state of FPC
When FPC is completely inserted, visually inspect the inserted status of FPC. (Example 3)
[Caution]
FPC is not inserted deep enough or in a diagonal direction. (Example 4)(Example 5)
As this connector is a small-sized, thin product, care needs to be taken when handling.
Check the following before use.
―Correct operation
Actuator [Open]
PCB
Metal locking guide of FPC is
hidden in the insulated case.
Insulation case
Metal locking guide of FPC is
visible from the insulated case.
Insulation case
Metal locking guide of FPC is
visible from the insulated case.
Insulation case
FPC (shallow)
Incorrect operation
Incorrect operation
Correct operation
FPC [diagonal]
OK
OK
NG
NG NG
(Example 1)
(Example 3) (Example 4) (Example 5)
(Example 2)
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
8
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
[Operation method]
󱽧Operation Methods of Connectors and Precautions
4. Actuator locking mechanism
Actuator rotates around the actuator rotation axis.
After inserting FPC, operate the actuator rotating 90°.
[Caution]
Operate the actuator around the center when locked. (Example 6)
Do not operate the actuator on one side only when locked. (Example 7)
Do not operate the actuator by pushing in the vertical direction. (Example 8)
Do not apply excessive force to the housing during operation. (Example 9)
Correct operation ―― Incorrect operation
Operate the actuator around the center. Operate the actuator on one side.
Actuator
Incorrect operation
PCB
Incorrect operation
Apply an excessive force to the housing.
PCB
Actuator Actuator
PCB
Correct operation
Operate the actuator on one side.
Operate the actuator around the center.
Incorrect operation
Correct operation
A load is applied to the actuator
in the opposite direction.
PCB
Incorrect operation
Actuator
PCB
Incorrect operation
OK NG
NG
NG
(Example 6)
(Example 8)
(Example 10)
(Example 11)
(Example 13)
(Example 7)
(Example 9)
(Example 12)
(Example 14)
5. How to unlock the actuator
Push the actuator up slowly and release the lock. (Example 10)
[Caution]
Operate the actuator around the center when unlocked. (Example 11)
Do not operate the actuator on one side only when unlocked. (Example 12)
The actuator cannot be opened to over 90°, Do not open it over this angle. (Example 13)
This connector adopts a back-flip design, and there is difference between the FPC insertion direction and
the direction of the actuator. Do not try to open FPC from its insertion side. (Example 14)
NG NG
NG
OK
OK
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
9
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
[Operation method]
󱽧Operation Methods of Connectors and Precautions
6. How to remove FPC
After releasing the actuator lock , remove the FPC in the horizontal direction. (Example 15)
[Caution]
When pulling out FPC, don't apply load in the upward or lateral direction. (Example 16)
Don't pull out FPC while the actuator is locked. (Example 17)
PCB PCB
Correct operation ―― Incorrect operation
Actuator [Open] Actuator [Open]
FPC [diagonal]
Incorrect operation
PCB
Actuator [Closed]
7. Routing of FPC
Depending on the routing of FPC to mate, a load may be applied to the connector, which could lead to a
failure. In order to prevent failure, please consider the following concerning the mechanism design.
[Caution]
When routing FPC, please be careful that FPC is not pulled and routing is carried out with a margin.
Please check that the stiffener is placed horizontal to the board surface. (Example 18)
Please insure there is no load is applied to the connector in the pulling, inserting or lateral direction.
(Example 19)(Example 20)
When routing the FPC , carry out the routing operation in a manner that no direct load is applied to the
connector. Please take some caution such as to fix FPC etc. (Example 19)
Don't place any parts under the FPC that will interfere with FPC. (Example 21)
(Example 15)
(Example 17)
(Example 16)
OK NG
NG
The state where a load
is applied to FPC
Stiffener
PCB
Parts interfering with FPC
The state where a load
is applied to FPC
Stiffener
Stiffener
PCB
PCB
(Example 18)
(Example 20)
(Example 19)
(Example 21)
NG
NG
NG
OK
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
10
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
[Cautions when Mounting PCB]
SWarp of PCB
Minimize warp of the PCB as much as possible.
Lead co-planarity including reinforced metals is 0.1mm or less.
Too much wrap of the PCB may result in a soldering failure.
SFlexible board design
Please make sure to put a stiffener on the backside of the flexible board.
We recommend a glass epoxy material with the thickness of 0.3mm MIN.
SLoad to Connector
Do not add 0.5N or greater external force when unreel or pick and place the connector etc,
or it may get broken.
In addition, do not insert the FPC or operate the connector before mounting.
SLoad to PCB
Splitting a large PCB into several pieces
Screwing the PCB
Avoid the handling described above so that no force is
exerted on the PCB during the assembly process.
Otherwise, the connector may become defective.
SInstructions on manual soldering
Follow the instructions shown below when soldering
the connector manually during work, etc.
qDo not perform manual soldering with the FPC inserted into the connector.
wDo not heat the connector excessively. Be very careful not to let the soldering iron contact any parts other than connector
leads. Otherwise, the connector may be deformed or melt.
eDo not supply excessive solder (or flux).
If excessive solder (or flux) is supplied on the terminals, solder or flux may adhere to the contacts or rotating parts of the
actuator, resulting in poor contact or a rotation failure of the actuator.
Supplying excessive solder to the chucking metals may hinder actuator rotation, resulting in breakage of the connector.
Connector
FPC
(For connectormounting)
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
11
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
MEMO
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.
12
FH64MA Series
0.25mm Pitch, 0.5mm High, Top Contact, Back Flip Super Low Profile FPC Connector
2-6-3,Nakagawa Chuoh,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN
TEL: +81-45-620-3526 Fax: +81-45-591-3726
http://www.hirose.com
http://www.hirose-connectors.com
®
The characteristics and the specifications contained herein are for reference purpose. Please refer to the latest customer drawings prior to use.
The contents of this catalog are current as of date of 02/2017. Contents are subject to change without notice for the purpose of improvements.
USA:
HIROSE ELECTRIC (U.S.A.), INC. SAN JOSE OFFICE
2841 Junction Ave, Suite 200
San Jose, CA. 95134
Phone : +1-408-253-9640
Fax : +1-408-253-9641
http://www.hirose.com/us/
USA:
HIROSE ELECTRIC (U.S.A.), INC. DETROIT OFFICE (AUTOMOTIVE)
17197 N. Laurel Park Drive, Suite 253,
Livonia, MI 48152
Phone : +1-734-542-9963
Fax : +1-734-542-9964
http://www.hirose.com/us/
USA:
HIROSE ELECTRIC (U.S.A.), INC. BOSTON OFFICE
300 Brickstone Square Suite 201,
Andover, MA 01810
Phone : +1-978-662-5255
USA:
HIROSE ELECTRIC (U.S.A.), INC. HEADQUARTERS CHICAGO OFFICE
2300 Warrenville Road, Suite 150,
Downers Grove, IL 60515
Phone : +1-630-282-6700
http://www.hirose.com/us/
CHINA:
HIROSE ELECTRIC TECHNOLOGIES (SHENZHEN) CO., LTD.
Room 09-13, 19/F, Office Tower Shun Hing Square, Di Wang Commercial Centre,
5002 Shen Nan Dong Road, Shenzhen City, Guangdong Province, 518008
Phone : +86-755-8207-0851
Fax : +86-755-8207-0873
http://www.hirose.com/cn/
KOREA:
HIROSE KOREA CO.,LTD.
143, Gongdan 1-daero, Siheung-si,
Gyeonggi-do, 15084, Korea
Phone : +82-31-496-7000
Fax : +82-31-496-7100
http://www.hirose.co.kr/
GERMANY:
HIROSE ELECTRIC EUROPE B.V. NUREMBERG OFFICE
Neumeyerstrasse 22-26, 90411 Nurnberg
Phone : +49-911 32 68 89 63
Fax : +49-911 32 68 89 69
http://www.hirose.com/eu/
GERMANY:
HIROSE ELECTRIC EUROPE B.V. HANOVER OFFICE
Bayernstr. 3, Haus C 30855 Langenhagen, Germany
Phone : +49-511 97 82 61 30
Fax : +49-511 97 82 61 35
http://www.hirose.com/eu/
GERMANY:
HIROSE ELECTRIC EUROPE B.V. GERMAN BRANCH
Schoenbergstr. 20, 73760 ostfildern
Phone : +49-711-456002-1
Fax : +49-711-456002-299
http://www.hirose.com/eu/
FRANCE:
HIROSE ELECTRIC EUROPE B.V. PARIS OFFICE
130 Avenue Joseph Kessel, Bat E, 78960
Voisins le Bretonneux, France
Phone : +33-1-85764886
Fax : +33-1-85764823
http://www.hirose.com/eu/
THE NETHERLANDS:
HIROSE ELECTRIC EUROPE B.V.
Hogehillweg #8 1101 CC Amsterdam Z-O
Phone : +31-20-6557460
Fax : +31-20-6557469
http://www.hirose.com/eu/
UNITED KINGDOM:
HIROSE ELECTRIC EUROPE BV (UK BRANCH)
4 Newton Court, Kelvin Drive, Knowlhill,
Milton Keynes, MK5 8NH
Phone : +44-1908 202050
Fax : +44-1908 202058
http://www.hirose.com/eu/
CHINA:
HIROSE ELECTRIC (SHANGHAI) CO., LTD.
18, Enterprise Center Tower 2, 209# Gong He
Road, Jing’an District, Shanghai, CHINA 200070
Phone : +86-21-6391-3355
Fax : +86-21-6391-3335
http://www.hirose.com/cn/
CHINA:
HIROSE ELECTRIC (SHANGHAI) CO.,LTD. BEIJING BRANCH
A1001, Ocean International Center, Building 56# East 4th
Ring Middle Road, ChaoYang District, Beijing, 100025
Phone : +86-10-5165-9332
Fax : +86-10-5908-1381
http://www.hirose.com/cn/
TAIWAN:
HIROSE ELECTRIC TAIWAN CO., LTD.
103 8F, No.87, Zhengzhou Rd., Taipei
Phone : +886-2-2555-7377
Fax : +886-2-2555-7350
http://www.hirose.com/tw/
HONG KONG:
HIROSE ELECTRIC HONGKONG TRADING CO., LTD.
Room 1001, West Wing, Tsim Sha Tsui Centre, 66
Mody Road, Tsim Sha Tsui East, Kowloon, Hong Kong
Phone : +852-2803-5338
Fax : +852-2591-6560
http://www.hirose.com/hk/
INDIA:
HIROSE ELECTRIC SINGAPORE PTE. LTD. DELHI LIAISON OFFICE
Office NO.552, Regus-Green Boulevard, Level5, Tower C,
Sec62, Plot B-9A, Block B, Noida, 201301, Uttar Pradesh, India
Phone : +91-12-660-8018
Fax : +91-120-4804949
http://www.hirose.com/sg/
SINGAPORE:
HIROSE ELECTRIC SINGAPORE PTE. LTD.
03, Anson Road, #20-01, Springleaf Tower,
Singapore 079909
Phone : +65-6324-6113
Fax : +65-6324-6123
http://www.hirose.com/sg/
INDIA:
HIROSE ELECTRIC SINGAPORE PTE. LTD. BANGALORE LIAISON OFFICE
Unit No-403, 4th Floor, No-84, Barton Centre, Mahatma
Gandhi (MG) Road, Bangalore 560 001, Karnataka, India
Phone : +91-80-4120 1907
Fax : +91-80-4120 9908
http://www.hirose.com/sg/
MALAYSIA:
PENANG REPRESENTATIVE OFFICE
73-3-1, Ideal@The One, Jalan Mahsuri, Bayan
Lepas Penang, 11950, Malaysia
Phone : +604-648-5536
http://www.hirose.com/sg/
THAILAND:
BANGKOK OFFICE (REPRESENTATIVE OFFICE)
Unit 4703, 47th FL., 1 Empire Tower, South Sathorn
Road, Yannawa, Sathorn, Bangkok 10120 Thailand
Phone : +66-2-686-1255
Fax : +66-2-686-3433
http://www.hirose.com/sg/
Jul.1.2020Copyright2020HIROSEELECTRICCO.,LTD.AllRightsReserved.