1
SCHRACK
General Purpose Relays
PCB Relays
Power PCB Relay RZ
Coil Data
Coil voltage range 3 to 48VDC
Operative range, IEC 61810 2
Coil insulation system according UL1446 class F
Coil versions, DC coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
D003 3 2.1 0.3 22 410
D005 5 3.5 0.5 60 420
D006 6 4.2 0.6 90 400
D009 9 6.3 0.9 200 400
D012 12 8.4 1.2 360 400
D015 15 10.5 1.5 562 410
D024 24 16.8 2.4 1440 400
D048 48 33.6 4.8 5730 400
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Insulation Data
Initial dielectric strength
between open contacts 1000Vrms
between contact and coil 5000Vrms
Clearance/creepage
between contact and coil ≥10/10mm
Material group of insulation parts IIIa
Tracking index of relay base PTI250V
n 1 pole 12/16 A, 1 form C (CO) or 1 form A (NO) contact
n DC coil 400 mW
n 5kV/10mm coil-contact, reinforced insulation
n Ambient temperature 85°C (clear cover: 70°C)
n Product in accordance to IEC 60335-1
Typical applications
Household appliances, boiler control, timers, garage door control, POS
automation
Approvals
VDE REG.-Nr. C693, UL E214025 CQC: CQC12002066685
Technical data of approved types on request
Contact Data 12A 16A
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage 250VAC
Max. switching voltage 400VAC
Rated current 12A 16A
Limiting making current (form A contact)
max. 4s, duty factor 10% 30A
max. 20ms (incandescent lamp); AgSnO2 80A
Breaking capacity max. 3000VA 4000VA
Contact material AgNi 90/10 or AgSnO2
Frequency of operation, with/without load 360/72000h-1
Operate/release time max. 8/6ms
Bounce time max., form A/form B 4/6ms
Contact ratings
Type Contact Load Cycles
IEC 61810
RZ03-1A. A (NO) 16A, 250VAC, 85°C 50x103
RZ03-1C4 C (CO) 16A, 250VAC, 85°C 10x103
RZ01-1A3 A (NO) 12A, 250VAC, 85°C 100x103 1)
RZ01-1A4 A (NO) 12A, 250VAC, 85°C 50x103
RZ01-1C4 C (CO) 12A, 250VAC, 85°C 30x103
RZ01-1.4 A (NO) 12A, 250VAC, 70°C 100x103
RZ0.-1A4 A (NO) 10A, 250VAC, 85°C 250x103
UL 508
RZ03-1A. A (NO) 16A, 250VAC, 85°C 50x103
RZ03-1A4 A (NO) 12A, 250VAC, 85°C 150x103
RZ01-1A3 A (NO) 12A, 250VAC, 85°C 50x103
RZ03-1.4 A (NO) B300, R300, 85°C 6x103
RZ03-1.4 A (NO) 12A, 250VAC, 85°C 100x103
RZ03-1.4 A (NO) 1/2hp, 125VAC, 85°C 6x103
RZ03-1A. A (NO) 1hp, 277VAC, 85°C 30x103
Mechanical endurance >10x106 operations
1) planned rating