www.clare.com
DS-CPC1961G-R02 1
CPC1961G
AC Solid State Relay
Part # Description
CPC1961G 8 Pin Dip (50/Tube)
CPC1961GS 8 Pin Surface Mount (50/Tube)
CPC1961GSTR 8 Pin Surface Mount (1000/Reel)
CPC1961G Units
Blocking Voltage 600 VP
Load Current 1200 mA
On State Voltage Drop 3.0 Vrms (at IL = 250mA)
1 One Pole Operating
Applications
Features
Description
Ordering Information
Pin Configuration
Programmable Control
Process Control
Power Control Panels
Remote Switching
Gas Pump Electronics
Contactors
Large Relays
Solenoids
Motors
Heaters
Load Current up to 200 mA
600V Blocking Voltage
5mA Sensitivity
Zero-Crossing Detection
DC Control, AC Output
Optically Isolated
TTL and CMOS Compatible
Low EMI and RFI Generation
High Noise Immunity
Machine Insertable, Wave Solderable
Flammability classification rating of V-0
The CPC1961G is a dual pole AC solid state switch
that uses optical coupling with dual monolithic SCR
outputs to produce an alternative to optocoupler and
triac circuits. The CPC1961G switches are robust
enough to provide a blocking voltage of up to 600V.
In addition, tightly controlled zero cross circuitry
ensures switching of AC loads without the generation
of transients. The input and output circuits are optically
coupled to provide 3750Vrms of isolation and noise
immunity between control and load circuits. As a
result the CPC1961G is well suited for industrial
environments where electromagnetic interference
would disrupt the operation of electromechanical
relays. The CPC1961G is offered in a space saving
8 pin DIP package with two independent switches.
Approvals
UL recognized; File #E69938
CPC1961G Pinout
– LED
+ LED
AC Load
AC Load
ZC
ZC
AC Load
AC Load
– LED
+ LED
1
2
3
4
8
7
6
5
www.clare.com
2
CPC1961G
Rev. 2
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings (@ 25˚ C)
Electrical Characteristcs
Parameter Ratings Units
Blocking Voltage 600 VP
Reverse Input Voltage 5 VP
Input Control Current
Peak (10ms)
50 mA
1 A
Input Power Dissipation 1150 mW
Total Package Dissipation 2800 mW
Isolation Voltage Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate Linearly 1.33 mW/˚C
2 Derate Linearly 6.67 mW/˚C
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Operating Voltage Range VT- 20 - 240 Vrms
Load Current 4VL=120-260Vrms, Continuous IL0.005 - 200 mArms
Non-repetitive Single Cycle Surge Current - ITSM - - 1.0 A
Off State Leakage Current VDRM ILEAK - - 1 mA
On-State Voltage Drop IL=250 mA - - 3.0 Vrms
Critical Rate of Rise 3- dv/dt 1000 - - V/µs
Switching Speeds
Turn-on IF=5 mA TON - - 0.5 cycles
Turn-off IF=5 mA TOFF - - 0.5 cycles
Zero-Cross Turn-On Voltage
1st half cycle - 5 20 V
Sub. half cycle - - - 5 V
Operating Frequency 1- 20 - 400 Hz
Load Power Factor for Guaranteed Turn-On 260 Hz PF 0.25 - - -
Input Characteristics @ 25°C
Input Control Current
For Normal Environment - IF5 - - mA
For High Noise Environment - IF10 - - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Input Drop-out Voltage - 0.8 - - V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics @ 25°C
Input to Output Capacitance - CI/O - 3 - pF
1 Zero Cross 1st half cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 Maximum current with one pole operating. Maximum continuous load current with both poles operating simultaneously is 110mA.
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product
descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clares Standard Terms and Conditions of Sale, Clare, Inc. assumes no
liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement
of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended
to support or sustain life, or where malfunction of Clares product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to
discontinue or make changes to its products at any time without notice.
Specification: DS-CPC1961G-R02
©Copyright 2005, Clare, Inc.
All rights reserved. Printed in USA.
2/23/04
For additional information please visit our website at: www.clare.com
MICHANICAL DIMENSIONS
7.239 TYP.
(0.285)
3.302
(0.130)
9.144 TYP.
(0.360)
8 Pin DIP Through Hole (Standard)
PC Board Pattern
(Top View)
8-0.800 DIA.
(8-0.031 DIA.)
Dimensions:
mm
(inches)
PC Board Pattern
(Top View)
3.302
(0.130)
0.254 TYP.
(0.010)
0.635 TYP.
(0.025)
8 Pin Surface Mount (“S” Suffix)
Tape and Reel Packaging for 8 Pin Surface Mount Package
User Direction of Feed
Embossment
Embossed Carrier
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
330.2 DIA.
(13.00 DIA.)
1 8
K1 = 4.20
(0.165)
Top Cover
Tape
K0 = 4.90
(0.193)
P = 12.00
(0.472)
W = 16.30 max
(0.642 max)
Bo = 10.30
(0.406)
Ao = 10.30
(0.406)
NOTE: Tape dimensions not shown, comply with JEDEC Standard EIA-481-2
Manufaturing Information
Soldering
Recommended soldering processes are limited to
245ºC component body temperature for 10 seconds.
Washing
Clare does not recommend ultrasonic cleaning or the
use of chlorinated solvents.