LPM/LPX 1000
The LP 10 0 0 Series wet/wet differential pressure
transmitter is ideally suited for use in clean-room
HVAC monitoring and control. The device offers
several improvements over traditional sensors such
as user accessible damping, excellent long term
stability, and wet/wet differential operation where
conductive fluids may be exposed to the
measurement diaphragms. For applications where
the pressure transmitter will be installed within one
of the pressure zones, the LPM/LPX 1000 is
available in a wet/wet gauge pressure configuration
where the second pressure port is eliminated,
venting the sensor directly to the atmosphere.
The LP 10 0 0 Series offers a dramatic improvement
in reliability with improved stability and the ability
to tolerate condensing atmospheres. The design
has been field proven for more than 10 years in
applications where high humidity and condensing
atmospheres are daily occurrences. The damping
adjustment feature allows the user to slow the
response time to eliminate nuisance trips of alarms
when doors are opened and closed.
LLPPMM//LLPPXX 11000000 SSeerriieess
Ultra Low Differential Pressure Transmitter
!
Ranges: ±0.1 to ±6 inH20
!
Accuracy:
±0.5% FS BSL (±0.25% FS optional)
!
NIST calibration certificate option
!Gauge or wet/wet differential pressure
!
User accessible damping
!Unidirectional or bidirectional operation
!Current or voltage output
!Optional local display
AASSSSOOCCIIAATTEEDD PPRROODDUUCCTTSS
LDI 1001 - DIN mountable LED local display
DPI 280 Series -Panel mount indicator
LPX 1000 LCD - Low differential pressure
transmitter with integral
LCD displays
LPM/LPX 200 0 -Low pressure differential sensors
LPM/LPX 500 0 -Ultra low pressure differential
sensors
LPM/LPX 800 0 -Low pressure differential sensors
LPM/LPX 900 0 -Low pressure high accuracy
differential sensors
DDrruucckk IInnccoorrppoorraatteedd
4 Dunham Drive
New Fairfield, CT 06812
Tel: (203) 746-040 0
Fax: (203) 746-2494
E-mail: usa.sales@druck.com
www.druck.com
www.pressure.com
Representative
PDS-A079 1/02
IINNSSTTAALLLLAATTIIOONN DDRRAAWWIINNGGSS:: Dimensions in inches
!!"
SSTTAANNDDAARRDD SSPPEECCIIFFIICCAATTIIOONN
Operating Ranges
Pressure Media
Fluids compatible with Iridited Aluminum,
Beryllium Copper and Brass
Transduction Principle
Variable inductance
Combined Non-linearity, Hysteresis, and
Repeatability
±0.5% of calibrated range
Option A, improved performance ±0.25% of
calibrated range
Temperature Effects
Temperature effects including both zero and span
over the temperature range 32° to 122°F
±0.01 inH2O for ranges above 0.5 and below
±0.02 inH2O for ranges above 0.5 inH2O up to 1inH2O
±0.06 inH2O for ranges above 1 inH2O up to 3 inH2O
±0.12 inH2O for ranges above 3 inH2O up to 6 inH2O
Note: Typical temperature shift of 10°F results in a
typical change in reading of 0.001 inH2O
Resolution
Infinite
Relative Humidity
0 to 10 0%; sensor will operate with condensing
moisture as well as conductive fluids applied to
the measuring diaphragms
Adjustment Range
Unit calibrated in the "wall-mount" orientation with
the connector positioned as in the installation
drawing below. Zero adjustment is sufficient for
all specified conditions via non-interacting, user
accessible potentiometers.
Span adjustment - ±5% FS
!!"
LLPPMM//LLPPXX 11000000 SSeerriieess
Ultra Low Differential Pressure Transmitter
Operating Temperature Range
-5°F to +185°F Process
+32°F to +122°F Compensated
Long-term Stability
±0.5%FS/YR
Power Supply Effect
±0.05% FS/Vdc
Output / Input
Response Time
User adjustable from 10 msec to
2 seconds
Insulation Resistance
10 0 Megohms @ 50 Vdc
Mechanical Characteristics
Sensor Housing
Iridited aluminum
Measurement Diaphragm
Beryllium copper with brass t arget
Pressure Port
10-32 UNF with barbed fitting
Electrical Connection
DIN connector 43650A
Weight
Gauge pressure - 16 oz.
Differential Pressure - 21 oz.
Safety
CE Marked
Ingress
Nema 3 (IP64)
Nominal measurement Overpressure Max line pressure
Range in inH2O (psig) (psig)
0.1
0.25
0.5
0.75
1
2
2.5
3
4
5
6
3
3
3
3
3
15
15
15
15
15
15
30
30
30
30
30
30
30
30
30
30
30
Unidirectional Supply Recommended Load
4-20mA, 2-wire
0-2.5 Vdc, 3-wire
0-5 Vdc, 3-wire
0-1 0 Vdc, 3-wire
1 -5 Vdc, 3-wire
1 0-30 Vdc
1 0-30 Vdc
1 0-30 Vdc
1 5-30 Vdc
1 0-30 Vdc
Rc(in K) (Vs-10) / 20
5000 Ohms Min
5000 Ohms Min
5000 Ohms Min
5000 Ohms Min
Bidirectional Supply Recommended Load
12±8mA, 2-wire
2.5±2.5 Vdc, 3-wire
5±5 Vdc, 3-wire
1 0-30 Vdc
1 0-30 Vdc
1 5-30 Vdc
Rc(in K) (Vs-10) / 20
5000 Ohms Min
5000 Ohms Min
Continuing development sometimes necessit ates
specification changes without notice.
Druck is an ISO 9001
registered company
OORRDDEERRIINNGG IINNFFOORRMMAATTIIOONN
(1) Select model number
Code Series Identifier
10 Base Model
Code Output Type
LPX Current output
LPM Volt age output
Code Reference
0 Vented gauge
1 Wet/wet differential
Code Pressure Port
0 10-32 UNF with barbed
fitting
LPX 10 1 0
DIFFERENTIAL
GAUGE
OOPPTTIIOONNSS
(A) Improved accuracy ±0.25% of calibrated range
(B) N.I.S.T. calibration cerificate (5 points)
(2) State pressure range
(3) State output required
(4) Options (if required)